• 제목/요약/키워드: Electric Power Consumption

검색결과 757건 처리시간 0.034초

중앙 냉방시스템의 전력량 요금절감을 위한 디맨드제어 적용방안 연구 (Demand Control Application Strategies for Saving Electric Power Price of Central Cooling System)

  • 황진원;송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2012
  • In this study, computer simulation for demand control strategies to save the electric energy and power price in the building central cooling system is done. The demand control and outdoor reset control algorithms are applied by consideration the electric energy and power price according to the energy consumption characteristics. The suggested control methods show better responses in the power price and energy consumption in comparison with the conventional one.

A Study for DC 1500V Railroad System Modeling Using EMTDC

  • 이한상;이장무;이한민;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.218-219
    • /
    • 2006
  • This paper is about modeling on 1500V DC electric railroad system. Electric railroad systems have peculiar characteristics against other electric system. The characteristics arc that the railroad systems have electric vehicle loads which are power-varying and location-varying with time. Because of this load characteristic, the electric railroad system modeling which reflects its own characteristics on EMTDC simulation could not be achieved. However, to reflect load characteristic on EMTDC, this paper suggests electric railroad system modeling by using TPS (Train Performance Simulator) that was developed in Korea Railroad Research Institute. A TPS program has various kinds of input data, such as operation condition, vehicle condition, and power system condition. By these data, TPS calculates mechanical power consumption and location, especially it decide electric power consumption on the basis of the fact that consumed electric and mechanical power are equal. Moreover, on this paper, movement of vehicle is reflected on EMTDC simulation as variation of feeder impedance. Also, an electric vehicle load is modeled as time-varying constant power load model.

  • PDF

복합다용도 수용가의 전력소비특성 분석 및 전기요금 산정프로그램 개발 (A Study on the Program for Estimation of Electric Rates and the Analysis for Power Consumption in Complex Consumer)

  • 김세동;유상봉;기유경
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.103-107
    • /
    • 2014
  • Together with housings, general buildings and industrial facilities, multi-purpose complexes are equipped with various and special equipment. They are often used by many unspecified people, which causes an increase in annual electricity consumption. Because of this, a great amount of money has been spent for electric charge, far more in excess of the budget, so a reasonable electricity rate needs to be estimated. In this study, we surveyed the power consumption, average power use, and annual electricity bill of multi-purpose complexes in the past five years. To see the general tendency of the survey, we conducted a statistical analysis with such parameters as average, maximum, and minimum values. Through regression analysis, we could see the trend of the survey in linear way. Based on the survey, we have developed an electric-rate calculation program to estimate the next year's budget on electricity.

반도체 공정장비 Gas Scrubber의 에너지 모니터링 시스템개발 (Development of an Energy MonItorIng System for Gas Scrubber)

  • 김선만;임익태;안강호
    • 반도체디스플레이기술학회지
    • /
    • 제10권2호
    • /
    • pp.13-17
    • /
    • 2011
  • We have developed a new energy-consuming monitoring system that has made it possible to measure the energy consumption of a gas scrubber, one of semiconductor processing equipments, and installed this system to the gas scrubber under operating at a manufacture site. Using this system, we have measured consumptions of electric power and processing gas consumed at standby to operating mode. In case of the gas scrubber, processing gas flows continuously into it at standby and operating mode. Therefore, if the electric power has been supplied, the processing gas can flows into the device for 24 hours. Moreover, at operating of gas scrubber, the amount of electricity consumption is 5 kWh. At Standby of gas scrubber, it spends 3kwh. It is certain that the energy consumption is greater at operating mode than at standby mode. The carbon emission rates from 24 hour gas scrubber operation are 236 $kgCO_2$/day of $N_2$, 57 $kgCO_2$/day of electric power and 0.001 $kgCO_2$/day of cooling water. Most of carbon is emitted from $N_2$ gas and electric power consumption.

업무용 빌딩의 전력소비 특성을 고려한 수용률/부등률의 적용에 관한 연구 (Recommended Practice for Demand Factor/Diversity Factor with respect to Power Consumption Characteristics in Commercial Buildings)

  • 김세동
    • 조명전기설비학회논문지
    • /
    • 제16권6호
    • /
    • pp.74-79
    • /
    • 2002
  • 계속되는 경제 성장과 고도 정보화 사회의 진전으로 전기에너지의 소비는 급격히 증가하고 있다. 특히 업무용 빌딩과 같은 전력다소비 건물에서는 전력의 효율적 이용에 의한 에너지절감은 물론 설계 단계에서의 합리적인 전기설비 설계가 요청되고 있다. 현재 우리나라의 기후 특성과 전력소비 특성을 고려한 합리적인 전기설비 설계를 위한 기초 자료가 매우 미흡한 실정이다. 본 연구는 업무용 빌딩의 전력소비특성을 조사하여 변전시설용량의 합리적 설계를 위한 수용률/부등률 적용 기준을 제시하고, 합리적 전기설비 설계를 유도하고자 한다.

회귀분석을 통한 창원시 중학교 전력소비량 예측에 관한 연구 (A Study on Prediction of Power Consumption Rate of Middle School Building in Changwon City by Regression Analysis)

  • 조형규;박효석;최정민;조성우
    • 교육녹색환경연구
    • /
    • 제12권2호
    • /
    • pp.61-70
    • /
    • 2013
  • As the existing school building power consumption is expressed by total power consumption, in the view of energy saving is disadvantage. The the power consumption of school building is divided as cooling, heating, lighting and others. The cooling power consumption, heating power consumption, lighting power consumption can be calculated using real total power consumption that gained from Korea Electric Power Corporation(KEPCO). The power consumption for cooling and heating can be calculated using heat transmittance, wall area and floor area, and for lighting is calculated by artificial lighting calculation. but this calculation methods is difficult for laymen. This study was carried out in order to establish the regression equation for cooling power consumption, heating power consumption, lighting power consumption and other power consumption in school building. In order to verify the validity of the regression equation, it is compared regression equation results and calculation results based on real power consumption. As the results, difference between regression result and calculation results for cooling and heating power consumption showed 0.6% and 3.6%.

RTGC의 연료절감을 위한 전압 보상 컨버터에 관한 연구 (A Study on the Voltage Compensation Converter to decrease fuel consumption of RTGC)

  • 바이사;류지수;한동화;이영진;이상호;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.280-282
    • /
    • 2011
  • This paper presents a development of voltage compensation dc/dc converter to decrease fuel consumption of RTGC system. We used 3-phase interleaved converter, which has the same structure as the commercially available three-phase inverter, is used. RTGC system is supplied the power from diesel-engine generator. According to power demand, engine speed is varying 20~60Hz, and voltage is varying 210Vac ~ 480Vac. When idle mode or low power operation dc/dc converter operates by constant output voltage control. The perpormance of converter is evaluated through several experiments with a real RTGC. Proposed system can cut down fuel consumption by 36% at idle mode operation.

  • PDF

공동주택 발코니 PV 연계 가정용 BESS의 에너지 절감 효과 분석 (Analysis of Energy Saving Effect of the Residential BESS Connected to the Balcony-PV in Apartment Houses)

  • 김차년;엄지영;김용기
    • 한국태양에너지학회 논문집
    • /
    • 제40권3호
    • /
    • pp.21-31
    • /
    • 2020
  • The government mandates gradually zero energy building and Photovoltaic power generation systems installed in buildings are emerging as the most realistic alternative to increase the independence rate of building energy. In this study, we propose a method to reduce the power consumption of households by increasing the PV capacity of balconies and applying the method used the charged electric power stored in batteries after sunset. In order to evaluate the electric power energy savings of the residential BESS, a balcony PV 1.2 kW and a battery pack 2 kWh were installed for 9 houses in 4 apartments in Seoul and Gyeonggi-do. The BESS is charged when the balcony PV is generated electric power, and when solar power generation is finished, it supplies power to the electric appliances connected to the load. As a result of installing the solar PV module 1.2 kW and 2 kWh class BESS for 3 households located in Seoul and Gyeonggi-do, the average electric power consumption saving rate was 40%. The reduction in electricity consumption in the case of zero generation surplus power by maximizing the utilization rate of BESS has been improved to about 53%. Therefore, in order to increase the self-sufficiency rate of electric energy in apartment houses, it is effective to increase the solar photovoltaic capacity of the balcony and apply the residential BESS. In the future, it is believed that the balcony PV and home BESS will play a key role in achieving mandatory zero-energy housing.

의류건조기의 열적 특성에 관한 실험 (Thermal Characteristics of an Electric Clothes Dryer)

  • 김준호;장석필;최철진;황교식;이호재
    • 대한기계학회논문집B
    • /
    • 제33권8호
    • /
    • pp.629-634
    • /
    • 2009
  • In this paper, drying mechanism is analyzed for improving the energy efficiency of an electric clothes dryer which consumes more electric power than other appliances. For the purpose, characteristic curves of the dryer such as temperature, relative humidity, evaporation rate, mass transfer coefficient, remaining moisture content curves are experimentally obtained. Based on the experimental results and analysis of drying mechanism, the effect of power of a heater and heat loss on the power consumption of an electric clothes dryer are systematically presented. These results demonstrate the feasibility of controlling heat loss at the heater as well as the backduct component to decrease the power consumption of an electric clothes dryer.