• 제목/요약/키워드: Electric Pole

검색결과 249건 처리시간 0.026초

건주 시공법에 따른 시공품질 비교 분석 (The Construction Quality Comparison and Analysis by Electric Poles Construction Method)

  • 김점식;권세원;박용범;문성원;조성문;김도영;고지훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.247-249
    • /
    • 2009
  • Electric pole construction of distribution place is mainly operated by excavation work using auger crane and backhoe. Even though construction quality is affected by electric pole construction method and amount of excavation, construction is operated by workers' convenience in most of construction place. Therefore, in this paper, we analyze and compare effectiveness of electric pole quality using auger crane and backhoe when mechanized excavation through displacement experience of electric pole with ground strength.

  • PDF

배전급 주상 변압기용 폴리머 부싱 설계 및 제조기술 (Design and Manufacture Technology of Polymer Bushing for Pole Mount Transformer)

  • 조한구;이운용;천종욱;박영두;강영길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.145-149
    • /
    • 2005
  • Recently, polymer insulator and bushing that are used for high voltage application have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. The pole mount transformer installed in distribution system is acting direct role in supply of electric power and the electric power device should drive safely for long tenn. In this paper, the polymer bushing of pole transformer is designed adaptively to current assembly method, designed bushing is manufactured on basis of that result. The electric field of designed transformer is investigated by FEM program.

  • PDF

전기자동차 압축기용 표면부착형 영구자석 전동기의 극/슬롯수 조합에 따른 특성해석 및 설계 (Design and Analysis of Surface-Mounted PM Motor of Compressor for Electric Vehicles Applications according to Slot/Pole Combinations)

  • 최장영;박형일;장석명;이성호
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1846-1857
    • /
    • 2011
  • This paper deals with design and analysis of surface-mounted PM (SPM) motor for compressor of air-conditioning system for electric vehicle applications according to slot/pole combination. First, required torque-speed curve characteristics are determined from operating conditions of the compressor. Restricted conditions such as motor size limit and current density are also determined. And then, under same rated and restricted conditions, twelve models which have different slot/pole combinations each other are designed for various pole arc/pitch ratio using simple equations and 2-d finite element (FE) analyses. Designed models are analyzed and compared in terms of back-emf THD, cogging torque, torque ripple, power losses, efficiency, etc. On the basis of analysis results, it is found that the motor with a 6-pole PM rotor and a 27-slot stator has most outstanding performances in electromagnetic aspects. Finally, through the mechanical modal analysis and demagnetization analysis, it is concluded that the determined motor is most suitable for the compressor of air-conditioning system for electric vehicles.

NLRE 곡선을 이용한 주상 변압기 월간 사용전력량 추정에 관한 연구 (A Study on Monthly Electric Energy Estimation of Pole-Transformer Using NLRE Curve)

  • 임진순;윤상윤;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.58-60
    • /
    • 2000
  • In this paper we present an estimation method of electric energy[kWh] for load management of pole-transformer. For the electric energy estimation, we use the nonlinear load research based estimation(NLRE) algorithm. The NLRE curve is the normalized annual cumulative energy consumption for a particular day in a year. And, it is used for the coefficient estimation. Estimation method of suggested electric energy of pole-transformer used billing cycle electric energy estimation equation is verified as comparison billing cycle electric energy and estimated electric energy. We can reduce the error of peak load estimation by suggested method than the conventional method in domestic.

  • PDF

전철주 및 문자 인식을 이용한 시설물 절대위치 검지 방법 (Pole Position Detection Method by Using Pole and Character Recognition)

  • 최우용;박종국;이병곤;주용환;한승훈
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.704-710
    • /
    • 2016
  • In this paper, we proposed pole position detection system for providing exact location information to users. The proposed system consists of pole recognition part and pole number recognition part. Above all, exact pole recognition is carried out by PDD(Pole Detection Device). And recognition of pole number is performed by PID(Pole Inspection Device). Acquired image by using line scan camera is judged whether it is free bracket or not through image processing. When it is judged as free bracket, pole number image is acquired by OCR camera and recognized by OCR. By recognizing pole number, exact location information is provided to user.

가공배전선로용 무정전 내장주 완철교체용 활선공구 및 표준활션공법 개발 (Development of Uninterruptible Hotline Tools and Method for Replacement of Strain Pole Crossarm on Overhead Distribution Line)

  • 김점식;송현석;문성원;박용범;조시형;최명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, developed a uninterruptible hotline tools and method for replacement of strain pole crossarm on overhead distribution line. For practical use of developed tools, following direct hot-line methods were proposed: 'Direct hot-lire method for replacement of pin pole crossarm', 'Direct hot-line method for alteration of crossarm' and 'Crossarm replacement method in uninterruptible cable displacement area'. These methods were proposed more simple and safe working on hotline job.

  • PDF

배전변압기의 전등부하 추정을 위한 상관계수 산정 및 신뢰성 검증 (Adjustment of correlation coefficient for Pole transformer's load estimation and its reliability verification.)

  • 박창호;한용희;김준오;조성수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1073-1075
    • /
    • 1999
  • This Paper Presents the process of load management for distribution Pole transformer at KEPCO. The purpose of this process is to establish reasonable peak load forecasting and prevention of Pole transformer damages caused by overload through the investigation of correlation coefficient for recent load characteristics. In this Paper, we newly proposed more reliable correlation coefficient using improved method and verified its reliability in various ways.

  • PDF

영구자석 다극 배치에 의한 가동 코일형 리니어 진도 엑츄에이터의 특성 (Characteristic of Moving Coil type Linear Oscillatory Actuator by Multi-Pole Permancent Magnet Arrangement)

  • 김덕현;강규홍;홍정표;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권6호
    • /
    • pp.273-281
    • /
    • 2001
  • In order to overcome the demerit and to improve the operation characteristics of Moving Coil type Linear Oscillatory Actuator(MC-LOA) with single-pole permanent magnet, this paper presents two models having the balanced magnetic circuit by multi-pole permanent magnet. They are short coil type with two-pole single-sided and two-ple double-sided permanent magnet. The characteristics between single-pole and multi-pole permanent magnet type MC-LOA are compared. As a result, multi-pole type MC-LOA has more merits than single-pole type about operation characteristics improvement and machine volume. The characteristics analysis is performed by their dynamic analysis composed of kinetic and electric equations and Finite Element Method(FEM). The propriety of multi-pole type MC-LOA model is verified with analysis results.

  • PDF

기상현상에 의한 전주 외력의 통계적 분석 (A Statistical Analysis of External Force on Electric Pole due to Meteorological Conditions)

  • 박철영;신창선;조용윤;김영현;박장우
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제6권11호
    • /
    • pp.437-444
    • /
    • 2017
  • 전주(Electric Pole)는 전력 송/배전에 사용되는 지지물로 환경적인 요인의 외력 변화에 민감하다. 전력 설비는 외부 환경변화와 재해로 부터 유지/보수적 관점에서 많은 어려움이 있다. 기상변화는 전주 피해에 주요인으로 작용하며, 경제적으로 미치는 영향이 매우 크다. 가공전선(Aerial Wire)은 온도 영향으로 탄성(Elasticity)변화가 나타나며, 탄성의 변화는 풍속, 풍향 등의 요인에 의해 영향력이 가중된다. 전선에 작용하는 외력은 전주의 피로누적으로 작용된다. 전주의 안전도 평가는 설계 단계에서 이루어지며, 운영중인 전주에 대한 영향도는 고려되지 않는다. 보수/안전성 확보 목적으로 외력의 기상요인 영향도를 분석하는 것은 매우 중요하다. 본 논문에서는 유지/안전성 확보 목적수행을 위해 전주에 설치된 센서노드의 가속도 데이터를 분석하고, 잡음(Noise) 보상 방법으로 칼만필터를 이용했다. 기상 요인별 영향도를 분석하기 위해 고속 푸리에 변환(Fast Fourier Transform)을 수행하고, 주파수 성분별 기상요인 영향도를 분석했다. 영향도 분석 결과 온도, 습도, 일사량, 일조시간, 대기압, 풍향, 풍속의 기상요인 영향이 크게 작용했다. 본 논문에서는 주파수 성분별로 기상요인의 영향도가 다름을 보였으며, 유지보수와 안정성 확보의 목적 달성에 중요한 요소로 작용될 수 있으리라 생각한다.

일반화 가법 모형을 이용한 전주 외력 모델링 (A Model-Fitting Approach of External Force on Electric Pole Using Generalized Additive Model)

  • 박철영;신창선;박명혜;이승배;박장우
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제6권11호
    • /
    • pp.445-452
    • /
    • 2017
  • 전주(Electric Pole)는 전력 송/배전에 사용되는 지지물로 외력 측정을 위해 가속도 센서가 이용된다. 기상현상은 전주의 외력에 다양한 영향을 미친다. 가공전선의 탄성변화가 그중 하나이다. 이러한 이유로 전주에 미치는 기상현상 요인을 모델링 하는 것은 매우 중요하다. 가속도 센서로부터 수신된 데이터는 피치(Pitch)와 롤(Roll) 각도로 변환되어 수신된다. 기상 현상은 변수간 상관관계가 높게 나타나며, 모델링을 위해 유의한 설명변수를 선택하는 것은 과대적합(Over Fitting)의 문제에서 매우 중요한 요소이다. 다중공선성(Multicollinearity)을 고려한 설명력이 높은 모델 구축을 위해 기계학습 방법의 하나인 일반화 가법 모형(Generalized Additive Model)을 사용했다. 모델 구축에 사용된 기상 요인 변수는 온도, 습도, 강수량, 풍속, 풍향, 증기압, 대기압, 노점온도, 일조시간, 일사량, 운량이다. 분산 팽창 요인 검증을 수행한 결과 온도, 강수량, 풍속, 풍향, 대기압, 노점온도, 일조시간, 운량의 변수가 선택됐다. 설명변수중 일조시간, 운량, 대기압의 영향도가 높게 나타났으며, 일반화 가법 모형의 평균 결정계수(R-Squared)는 0.69로 유의한 모델을 구축했다. 구축된 모델은 전주 외력의 영향을 예측하는데 도움이 될 수 있을 것이며, 안전성 확보의 목적에 기여할 수 있을 것이라 생각한다.