• Title/Summary/Keyword: Electric Fire

검색결과 582건 처리시간 0.027초

실내조명환경의 시각적 쾌적성 확보 및 조명부하 저감을 위한 채광제어방법에 관한 연구 (A Study on Daylight Control Method for Securing Visual Comfort and Reducing Lighting Loads on Interior Lighting Environment)

  • 한상필
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.100-105
    • /
    • 2012
  • In previous study, to investigate the impression of the compound lighting based on the AC-Model at the full-size room, the impressions of various compound lighting were completed as compared with that of the uniform lightings through the comparison method (a paired comparison) by Semantic Differential scaling. Also, we examined the effect of the supplementary lighting type increasing the lights at the side of the window and the blind-control lighting type, and they were compared with the existing compound lighting type. In results, pared comparison of the compound lighting and the uniform lighting, indicates that the impression of the compound lighting is generally similar to that of the uniform lighting when there are same ratios of the light from the window. Based on these results, we suggest that the AC-Model might be applied to various conditions. And we also introduce the method for daylighting that it is possible to reduce discomfort glare and to improve visual impressions as the supplementary type and blind-control type on the compound lighting. And it was found that electric power consumption of the compound lighting room was lower than that of the uniform lighting room when as same lighting ratio of the compound lighting and the uniform lighting from the window was provided or there was the lighting distribution simulated to same light ratio from the window. Since the method of the ACModel was described in the experimental condition, additional studies should be performed to determine if this model could be applied to different window configurations, lighting layout and types of a room.

멀티 홉 Wi-Fi Direct 통신 기반 실시간 영상관리 시스템 성능 분석 (Performance Analysis of Real-Time Video Management System Based on Multi-Hop Wi-Fi Direct Communication)

  • 우채율;조미란;권순량
    • 한국통신학회논문지
    • /
    • 제41권11호
    • /
    • pp.1472-1480
    • /
    • 2016
  • 지진, 홍수, 태풍 등의 자연 재해 및 화재, 테러 등 재난 발생시 현장 상황의 영상을 촬영하여 지휘본부에 위치한 서버에 전송하여 현장상황을 한 눈에 파악할 수 있게 하는 영상관리시스템이 요구된다. 본 논문에서는 영상관리시스템 구축에 필요한 성능 요소 정보를 파악하기 위해 와이파이 다이렉트 통신 기반의 애드혹 망 구성 방법을 제시하고 영상관리시스템에 대한 환경 구축을 통해 성능을 평가하였다. 평가한 성능 시험항목은 '영상 압축률 및 영상 크기에 따른 패킷 흐름 시험', '거리에 따른 패킷 흐름 및 트래픽 시험', 'LOS(Line of Sight) 여부에 따른 패킷 흐름 시험', '시나리오 성능 시험'이다.

건설현장의 추락재해 감소방안을 위한 연구 - 2개층 이하 높이 추락재해 감소 방안 (A Study for Decrease Accident from Falls at the Construction Sites - Focused on Under 2nd Floor)

  • 박준기;신승하;이정원;김경환
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2008년도 정기학술발표대회 논문집
    • /
    • pp.918-921
    • /
    • 2008
  • 추락, 감전, 전도, 충돌, 화재, 신체절단 등 건설현장에서 발생하는 재해는 다양하다. 그 중에서 가장 많이 발생하는 재해는 추락이다. 그러므로 건설현장에서 건설재해를 줄이기 위한 첫 번째 단계는 추락재해를 줄이는 것이라고 할 수 있다. 이미 추락재해 감소를 위한 많은 연구가 이루어지고 있지만, 최근 추락재해의 증가 추세를 볼 때 이러한 연구는 구체적이지 못하다고 할 수 있다. 그러므로 본 연구에서는 추락재해 감소방안의 방향을 구체적으로 제시하고자 최근 07년 1월부터 08년 6월까지의 건설현장 추락재해의 원인들을 파악하였다. 이를 바탕으로 추락재해의 핵심요인을 파악하였으며 이러한 접근방법을 통하여 파악된 핵심요인을 집중적으로 관리함으로써 추락재해를 줄일 수 있을 것으로 예상된다. 나아가 전체 건설재해의 감소에 기여할 수 있을 것으로 예상된다.

  • PDF

Evaluation on the Lightning Breakdown Voltages of Palm Oil and Coconut Oil under Non-Uniform Field at Small Gap Distances

  • Thien, Yee Von;Azis, Norhafiz;Jasni, Jasronita;Kadir, Mohd Zainal Abidin Ab;Yunus, Robiah;Ishak, Mohd Taufiq;Yaakub, Zaini
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.184-191
    • /
    • 2016
  • In recent years, there are a number of studies that have been carried out to explore the alternative for Mineral Oil (MO) as dielectric insulating fluid in transformers due to the increasing tight regulation on safety and environment. Vegetable oils have been identified as suitable candidate since it is biodegradable, non-toxic and high flash/fire points which ensure more in-service safety. Among the types of vegetable oils considered for transformers application are Palm Oil (PO) and Coconut Oil (CO). This paper presents an experimental study on the lightning breakdown voltages of PO and CO under non-uniform electric field based on needle-sphere electrodes configuration at 3 small gap distances. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The main focus of this study is to examine the lightning breakdown performance of RBDPO and CO under different test conditions and assess its suitability as dielectric insulating fluid in transformers. The effect of voltage polarities (positive and negative) and testing methods (rising-voltage, up-and-down and multiple-voltage) were investigated. The data obtained from all tests were analysed by Weibull distribution in order to determine the withstand voltages for each type of oils. It was found that the breakdown voltages of RBDPO and CO are comparable with MO under positive lightning impulse. Under negative lightning impulse, the breakdown voltage of MO is slightly higher than RBDPO and CO. There is no significant effect of testing methods and voltage polarities on lightning breakdown voltages of RBDPO and CO. Based on the statistical analysis, it is found that the breakdown voltages of RBDPO and CO at 1% probability are slightly lower than MO.

인위적인 자외선 조사량에 따른 폴리머애자에서의 코로나 방전 특성 (A Study of Corona Discharge in Polymer Insulators by Artificial UV Radiation)

  • 김영석;최명일;김종민;방선배;송길목;곽동순
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.643-648
    • /
    • 2013
  • In this study, degradation was observed by irradiating UV rays to the polymer insulators which have been widely used in outdoor electric power facilities. For an indoor accelerated UV test, 0.55 w/m2 of UV rays were applied using a xenon-arc method. A UV detection system with 65 ${\phi}mm$ in diameter, 100 mm in length and 1.0 of brightness (F/#) has been designed. Even though efflorescence on the surface of polymer insulators wasn't observed according to the accelerated UV test. UV rays were detected at around 50% and 40% of insulation breakdown in EPDM and silicone-type insulators respectively. As degradation continued because of an indoor accelerated UV test, breakdown voltage with which UV rays can be detected in an early stage decreased as well. A silicone polymer insulator would be severer than EPDM polymer insulator in terms of surface degradation because of UV strength against $V_m/V_{BD}$ was high in silicone polymer insulators. UV strength in silicone-type insulators increased at 1,000 $kJ/m^2$ because contact angle at the intial stage sharply decreased to from $113^{\circ}$ to $92.1^{\circ}$.

삼천포화력발전소 3, 4호기 증설에 따르는 정밀발파작업으로 인한 인접가동발전기 및 구조물에 미치는 진동영향조사 (On the vibration influence to the running power plant facilities when the foundation excavated of the cautious blasting works)

  • 허진
    • 기술사
    • /
    • 제24권6호
    • /
    • pp.97-105
    • /
    • 1991
  • The cautious blasting works had been used with emulsion explosion electric M/S delay caps. Drill depth was from 3m to 6m with Crawler Drill ø70mm on the calcalious sand stone (soft-moderate-semi hard Rock). The total numbers of fire blast were 88 round. Scale distance were induces 15.52-60.32. It was applied to propagation Law in blasting vibration as follows. Propagation Law in Blasting Vibration (Equation omitted) where V : Peak partical velocity(cm/sec) D : Distance between explosion and recording sites(m) W : Maximum Charge per delay-period of eighit milliseconds o. more(kg) K : Ground transmission constant, empirically determind on the Rocks, Explosive and drilling pattern ets. b : Charge exponents n : Reduced exponents Where the quantity D / W$^n$ is known as the Scale distance. Above equation is worked by the U.S Bureau of Mines to determine peak particle velocity. The propagation Law can be catagrorized in three graups. Cubic root Scaling charge per delay Square root Scaling of charge per delay Site-specific Scaling of charge per delay Charge and reduction exponents carried out by multiple regressional analysis. It's divided into under loom and over 100m distance because the frequency is verified by the distance from blast site. Empirical equation of cautious blasting vibration is as follows. Over 30 ‥‥‥under 100m ‥‥‥V=41(D/$^3$√W)$\^$-1.41/ ‥‥‥A Over 100 ‥‥‥‥under 100m ‥‥‥V=121(D/$^3$√W)$\^$-1.56/ ‥‥‥B K value on the above equation has to be more specified for furthur understang about the effect of explosives, Rock strength. And Drilling pattern on the vibration levels, it is necessary to carry out more tests.

  • PDF

u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구 (A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module)

  • 박대우;김응식;최종문
    • 한국정보통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous 사회에서 기본 인프라를 구축하는 전력 공급망과 전력기기의 안전은 중요하다. u-City의 재난을 방지하기 위하여 u-IT전력기기의 모듈별 성능평가와 보안은 u-City 안전을 위해 꼭 필요하다. 본 논문에서는 u-IT전력기기의 모듈에 온도센서, 습도센서, 화재센서들을 탑재한 수배전반, 홈 분전반, Home Network Wall-Pad, 차단기, MPNP 블랙박스, 아크 검출기, 아크 안전기, 아울렛의 모듈별 성능평가 방안과 방법 및 보안방법을 연구한다. u-IT전력기기들은 센서의 정보들을 전달 및 분석하여 위험성을 사전 예방하여 안전성을 확보하고, 접근제어, 인증 등 보안대책으로 u-IT 전기안전통합관리시스템의 보안성을 강화시켜, 안전성과 보안성을 갖춘 u-City건설과 운영에 기여하게 될 것이다.

ZigBee통신 기반 ELB 누전전류 제어시스템 구현 (Implementation of ELB Leakage Current Control System based on ZigBee Communication)

  • 주재한
    • 전자공학회논문지 IE
    • /
    • 제49권2호
    • /
    • pp.52-57
    • /
    • 2012
  • 사회발전과 더불어 가전기기의 발전은 누전으로 인한 감전, 화재 등 여러 가지 누전전류의 위험성에 노출되어 있다. 가정 내 배전함에 누전차단기가 설치되어 있지만, 기존의 누전차단기는 배전함에 설치되어 누전시 전원을 차단해주는 기능만을 갖는다. 또한 집안 벽마다 설치된 콘센트에 연결된 가전기기들을 개별적으로 점검하는 일은 쉬운 일이 아니다. 따라서 본 논문에서는 누전차단기회로의 성능 및 회로를 분석하고, ZigBee기반의 센서를 이용하여 가정 내 가전기기들의 누전상태를 모니터링 할 수 있는 방법에 대해 제시하였다. 성능분석 결과, 제안된 ELB 누전전류 제어시스템은 가전기기에 내장된 누전차단기 회로를 응용했기 때문에 각각의 가전기기들의 누전상태를 확인할 수 있어 기존 시스템 보다 누전을 쉽고 편리하게 모니터링 할 수 있을 것이라 기대한다.

운전 중인 고전력 XLPE 케이블의 절연저항과 습도의 측정 시스템 설계 및 방식층 절연저항과 습도의 상관관계 (Design of Measuring System for Insulation Resistance and Humidity in High-Power XLPE Cables in Operation and the Relationship Between Insulation Resistance and Humidity in the Oversheath)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.179-184
    • /
    • 2016
  • 발전소가 생산한 고전압 전력을 전달하기 위해 사용하는 케이블은 주로 6.6 kV XLPE 케이블(또는 CV케이블)이다. 제작 기술, 설치환경 및 사용조건에 다르겠지만, 케이블은 설치하여 동작함과 동시에 열화과정이 진행된다. 접속재의 경우, 제조 결함이나 공사 결함이 있는 경우 대체로 동작 후 약 3 년 내에 고장을 일으키며, 그렇지 않는 경우 수명이 20-30 년을 지속하는 경우가 많다. 케이블 시스템(케이블 자체 및 접속재)의 상태가 나빠지는 경우, 절연 파괴현상으로 인한 사고가 발생한다. 우리는 케이블의 열화 상태를 감시하기 위한 장비를 개발하여 충남 태안의 한국서부발전주식회사(Korean Western Power Co. Ltd.)에 설치하였다. 이 논문에서, 운영 중에 있는 장비의 하드웨어적인 설계를 소개한다. 그 장비를 사용하여 고전력 케이블의 방식층 절연저항과 습도를 측정하였으며, 습도가 방식층의 절연저항에 미치는 영향을 분석한 결과를 제시한다.

마이크로프로세서를 이용한 아크결함 차단기 설계 (Arc Fault Circuit Interrupter Design using Microprocessor)

  • 윤광호;반기종;이효직;박병석;남문현
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.12-18
    • /
    • 2007
  • 본 연구에서 설계한 AFCI는 Arc 고장 차단기로서 종속된 전기 배선상의 노화, 절연 및 배선 파괴, 연결 고장, 절연과 배선에 과도한 기계적 손상으로 인한 아크고장을 검출하여 차단하는 기능을 가지고 있으며 기존 차단기가 가지고 있던 과전류에 의한 바이메탈의 만곡 특성에 의한 동작으로 차단하는 방식은 차단에 긴 시간이 걸리나 설계한 AFCI는 전자방식으로서 과부하, 과전류에 의한 기계적 , 전기적인 스트레스를 검출하여 차단하는 기능을 가진 제품으로 차단시간이 100% 이상 단축되어 전기 화재의 발생률을 낮추도록 하였다.