• Title/Summary/Keyword: Electric Field strength

Search Result 468, Processing Time 0.024 seconds

Optical Properties of Plasmons in a GaAs/AlxGa1-xAs Multiple Quantum Well Under Electric and Magnetic Fields (전기장과 자기장하의 GaAs/AlxGa1-xAs 다중 양자 우물 내 플라즈몬의 광학적 속성)

  • Ahn, Hyung Soo;Lee, Sang Chil;Kim, Suck Whan
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1183-1191
    • /
    • 2018
  • The plasmon behaviors in a superlattice of $GaAs/Al_xGa_{1-x}As$ multiple quantum wells with a half-parabolic confining potential due to different dielectric interfaces are studied under magnetic and electric fields perpendicular and parallel to the superlattice axis by using a previously published theoretical framework. From the density-density correlation functions by considering the intrasubband and the inter-subband transitions under the random phase approximation, we calculate the dispersion energies of the surface and the bulk states as functions of the composition of the multiple quantum well structure and of the magnetic field strength and the average electric field strength over the quantum well. The Raman intensities for various magnetic field strengths and average electric field strengths over the quantum well are also obtained as a function of the energy of the incoming light for these states.

Poling Field Effect on Absorption and Luminescence of Disperse Red-19 and TiO2 Composites

  • Kim, Byoung-Ju;Hwang, Un-Jei;Jo, Dong-Hyun;Lim, Sae-Han;Kang, Kwang-Sun
    • Current Photovoltaic Research
    • /
    • v.3 no.1
    • /
    • pp.5-9
    • /
    • 2015
  • Absorption and luminescence characteristics of disperse red-19 (DR-19) and $TiO_2$ composite have been investigated with various poling electric field strengths. Two step synthetic processes were employed to employ the DR-19 to the $TiO_2$ sol-gel. Firstly, urethane bond formation between DR-19 (-OH) and 3-isocyanatopropyl triethoxysilane (ICPTES, -N=C=O) performed (ICPDR) prior incorporation to the $TiO_2$ sol-gel. Secondary, the hydrolysis of the ethoxy group from the ICPTES and condensation reaction between silanol groups from ICPTES and $TiO_2$ sol-gel were performed. The ICPDR and $TiO_2$ sol-gel ($DRTiO_2$) were mixed and stirred for several days. The composite was coated to the ITO coated glass substrate. Corona poling were performed before drying the composite with various electric field strengths. The absorption intensity decreased with the increase of the poling field strength, which resulted in the increase of poling efficiency. The photoluminescence also decreased as the poling field strength increased. There is long luminescence tail for the poled $DRTiO_2$ film compared with unpoled $DRTiO_2$ film. The luminescence long tail indicates that the self-trapped excitons and polarons were generated when the $DRTiO_2$ film was poled with electric field.

Reliability Improvement of Titania Ceramics with Surface Flaw Through High Voltage Screening

  • Tanaka, Tomohiro;Kishimoto, Akira
    • The Korean Journal of Ceramics
    • /
    • v.5 no.4
    • /
    • pp.386-389
    • /
    • 1999
  • Effect of high voltage screening was examined on mechanical strength of titania ceramics with two different surface roughness. Roughly finished sample showed degraded mechanical strength meaning that the introduced flaw played the role of starting point of mechanical fracture. On such sample, electrically weak parts were eliminated by applying a screening field. Mechanical strength measurement on survived parts revealed that after screening the Weibull plots bended to become a convex curve while plots at high strength region were almost the same. This result means that relatively low mechanical strength parts were eliminated by the electrical method. As a result the Weibull modulus calculated from all the data increased, demonstrating the effect of high voltage screening on titania ceramics containing fracture controlling surface flaws. Roles of the surface flaw such as a common weak spot for both failures are disscussed in relation to the electric field concentration similar to that of mechanical stress.

  • PDF

Durability Evaluation of ER Fluids in Hydraulic Control Systems (유압제어시스템 적용을 위한 ER 밸브의 내구성 평가)

  • Kim, Do-Tae;Jang, Sung-Cheol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.100-105
    • /
    • 2007
  • Electro-rheological(ER) fluid and valve are fabricated and evaluated experimentally in its durability to utilize the hydraulic control systems for long term operation. The two-ports ER valve used in the experiment consist of twelve parallel multi-layer electrodes and provide a restriction to the passage of ER fluid because of the viscous pressure drop and a component induced by the electric field. The durability test of ER valve are performed by measuring the surface roughness of electrodes with variation of an electric field strength and test time(1000 or 1800min.). Also, the shear stress and shear rate are measured to evaluate the durability of ER fluid as function of time. After durability test, ER shear stress increases approximately proportional to the shear rate with applied electric field intensity, In the ER valve, the center line average height roughness(Ra) of copper electrode increases about 1.56 times and ten-point median height roughness(Rz) increases about 2.2 times after the durability test. An understanding of these durability is essential to predicting the service life of ER fluid and valves.

3-Axial Isotropic Electric-Field Probe Design with Resistor-Loaded Short Dipole (저항 부하된 소형 다이폴을 이용한 3축 등방성 전기장 프로브 설계)

  • Moon, Sung-Won;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.3
    • /
    • pp.246-249
    • /
    • 2017
  • In this paper, we designed the 3-axis isotropic electric-field measurement probe using resistor-loaded short dipole with lumped chip resistors. The designed probe shows good isotropic characteristics as well as wideband and low sensitivity. The isotropic characteristics of ${\pm}0.39dB$ from 100 kHz to the 3 GHz band were derived and the reception sensitivity was 0.1 V/m. The frequency response is within 3 dB of the whole section, especially ${\pm}1.3dB$ from 150 kHz to 3 GHz, which is superior to the conventional electric field probe with short dipoles.

Design and Fabrication of a Dual Cylindrical Microwave and Ohmic Combination Heater for Processing of Particulate Foods

  • Lee, Seung Hyun;Choi, Won;Park, Sung Hee;Jun, Soojin
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.250-260
    • /
    • 2015
  • Purpose: Dual cylindrical microwave chambers equipped with an ohmic heating tube were designed and fabricated to maximize the electric field strength for expeditious heat treatment of particulate foods. Methods: The efficacy of the combination heater was investigated by simulating the electric field distribution by using COMSOL Multiphysics software. Results: All components of the designed microwave heating unit were suitable for transmitting maximal microwave power to the load. The simulated electric field distribution implied that single-mode microwave heating would be sufficient for the steady generation of a highly localized heating zone in the cavity. During impedance matching, the calculated reflection coefficient ($S_{11}$) was small, possibly implying minimal power loss and wave reflection in the designed microwave heating chamber. Conclusions: This study demonstrates the possibility of concentrating the microwave power at the centerline for a single-frequency microwave, for thermal treatment of multiphase foods without attenuating the microwave power.

Electric Field Distribution Simulation of the Cable Joint Materials (케이블 접속재료의 전계분포 시뮬레이션)

  • Kim, Hyung-Joo;Byun, Doo-Gyoon;Shin, Jong-Yeol;Lee, Duk-Jin;Lee, Chung-Ho;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.601-604
    • /
    • 2001
  • The insulation materials of cables used for underground power transmission requires a higher insulating capability. and the most popular method to examine the cable is partial discharge test due to applying variation voltage. In the thesis. air void. silicone oil. of which may possibly exist real cables. are simulated by Electra 2D program. Also the relations between calculated field strength and the void defect type in the cable joint materails. In the modeling. electic field inner to the cable joint material composed by XLPE and EPDM is modeling simulated. We obtained the electric field distribution in void due to two conditions.

  • PDF

Experimental Study on the Effects of AC Electric Fields on Flame Spreading over Polyethylene-insulated Electric-Wire (폴리에틸렌으로 피복된 전선화염의 전파에 교류전기장이 미치는 영향에 관한 실험적 연구)

  • Jin, Young-Kyu;Kim, Min-Kuk;Park, Jeong;Chung, Suk-Ho;Kim, Tae-Hyung;Park, Jong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1015-1025
    • /
    • 2010
  • In this present study, we experimentally investigated the effects of electric fields on the characteristics of flames spreading over electric-wires with AC fields. The dependence of the rate at which a flame spreads over polyethylene-insulated wires on the frequency and amplitude of the applied AC electric field was examined. The spreading of the flame can be categorized into linear spreading and non-linearly accelerated spreading of flame. This categorization is based on the axial distribution of the field strength of the applied electric field. The rate at which the flame spreads is highly dependent on the inclined direction of the wire fire. It could be possible to explain the spreading of the flame on the basis of thermal balance.

Evaluation of Insulating Reliability in Epoxy Composites

  • Park, No-Bong;Yang, Dong-Bok;Lim, Jung-Kwan;Park, Yong-Pil;Lee, Hee-Kab;Kim, Gui-Yeul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1200-1203
    • /
    • 2003
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were applied to Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased, the stronger breakdown strength became at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher. Finally, according to Weibull distribution analysis, reducing breakdown probability of equipment insulation lower than 0.1% level requires the allowable field allowable field intensity values to be kept under 21.5 MV/cm.

  • PDF

Electromagnetic Wave and EMF Attenuation by Shielding Materials in home appliances (가전제품 전자파 현황 및 차폐재에 의한 감쇄 효과)

  • Cho, Jae-Cheol;Park, Jae-Hwan
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.711-718
    • /
    • 2019
  • Spectrum analyzer and electromagnetic field meter were used to investigate the EM generation behaviour in different types of home electrical appliances. During microwave oven operation, the EM power measured at a point 30cm apart was measured in the range of 8~11mW/㎡, the strength of the low frequency magnetic field was 60~80mG and the electric field strength was measured at 150~160V/m. For smart phone wireless charging pad, it was measured at an electromagnetic power of 0.4mW/㎡, an electric field of 160 V/m and a magnetic field of 1mG at a point 10cm away. For microwave oven and wireless charging pad, if used within 10cm, the size of the electric field has been measured at a large value that exceeds the human body protection standard and may be hazardous to humans. On the other hand, home appliances such as TVs, hairdryers and refrigerators all showed very low levels of electromagnetic waves, electric fields and magnetic fields, with no harmful effects seen. For electromagnetic shielding, the metal Cu fabric and metal foil had a high level of EM shielding, while polymer films had a low EM shielding characteristic.