• Title/Summary/Keyword: Electric Current Consumption

Search Result 154, Processing Time 0.027 seconds

Effects of Vehicle Electric Components on the Steering Input Torque (차량 전장 부품 특성이 MDPS 조타 토크에 미치는 영향)

  • Cho, Hyunseok;Lee, Byungrim;Chang, Sehyun;Park, Youngdae;Kim, Minjun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.6
    • /
    • pp.113-119
    • /
    • 2014
  • For the robust design of Motor Driven Power Steering (MDPS) systems, it is important to consider energy efficiency from every aspect such as system configuration and current flow, etc. If design optimization is not considered, it has many problems on a vehicle. For example, when evaluating steering test, particularly the Catch-up test which turning the steering wheel left or right quickly, steering effort should be increased rapidly. Also a vehicle might have poor fuel efficiency. In this study, it is calculated energy consumption for each component of the steering system and analyzed factors of energy consumption. As a result, this paper redefines a method to estimate steering input torque using characteristics of vehicle electric components and then conducts an analysis of contribution for the Catch-up.

Development and Performance Test of DC Smart Metering System for the DC Power Measurement of Urban Railway (도시철도 직류 전력량 계측을 위한 직류용 스마트미터링 시스템 개발 및 성능시험)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Jongyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.713-718
    • /
    • 2014
  • DC urban railway power system consists of DC power network and AC power network. The DC power network supplies electric power to railway vehicles and the AC power network supplies electric power to station electric equipment. Recently, because of power consumption reduction and peak load shaving, intelligent measurement of regenerative energy and renewable energy adapted on DC urban railway is required. For this reason, DC smart metering system for DC power network shall be developed. Therefore, in this paper, DC voltage sensor, current sensor, and DC smart meter were developed and evaluated by performance test. DC voltage sensor was developed for measuring standard voltage range of DC urban railway, and DC current sensor was developed as hall effect split core type in order to install in existing system. DC smart meter possesses function of general intelligent electric power meter, such as measuring electricity and wireless communication etc. And, DC voltage sensor showed average 0.17% of measuring error for 2,000V/50mA, and current sensor showed average 0.21% of measuring error for ${\pm}2,000V/{\pm}4V$ in performance test. Also DC smart meter showed maximum 0.92% of measuring error for output of voltage sensor and current sensor. In similar environment for real DC power network, measuring error rate was under 0.5%. In conclusion, accuracy of DC smart metering system was confirmed by performance test, and more detailed performance will be verified by further real operation DC urban railway line test.

A Study on the Electrostatic Precipitation of Auto-Bias Type by Corona Discharge (코로나방전에 의한 AUTO-BIAS형태의 전기집진에 관한 연구)

  • 이주상;김신도;김광영
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.79-88
    • /
    • 1995
  • The electrostatic precipitation of Auto- Bias has the advantages of a little of power consumption by the voltage to apply only at ionizer and the prevention of fire danger by current flow over. As this ionizer wire was used WXN- Pt material of diameter 90$\mu $m, that improved ion efficiency and safety, simplified a existing source of electric power by induced Auto- Bias voltage. Also, the new type collector used electric conductivity- film wag superior a electric safety and dust collection efficiency and was possible to wash it by water. As a experiment result of this Auto- Bias electrostatic collector, the induced Auto- Bias voltage by appling D.C 4.0∼6.0kV at ionizer was 1.3∼2.3kV and then the power consumption by applied voltage was 8- l8W. The pressure loss of collector by the amount of flowing was 6.1 OmmH$_{2}$O in 300m$^{3}$/hr and showed a safe state of the dust collection. The collection efficiency by particle size was 65.1-95.8% in 0.5∼5.0$\mu $m. After corona discharge of ionizer, the remains ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.

  • PDF

Design of 5" True Color FED Driving System (5″ FED True Color 구동시스템 설계)

  • Shin, Hong-Jae;Choi, Chang-Woon;Kim, Jin;Choi, Jeong-Og;Kwon, Oh-Kyong
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.65-68
    • /
    • 2000
  • We design a new driving system of 5" true color FED using current controlled PWM method. Further more, we successfully developed a 5" FED panel, which resolution is 320$\times$240(Color). When we design a 5" FED driving circuit, FED tips are modeled as R-C for circuit simulator of FED driving circuit. In Video data processing, parallel R, G, B input signals is processed independently, so duty ratio increase and no noise, high quality performance is achieved in display of 5" FED. The luminance is about 100cd/$m^2$, the anode power consumption Is 2.1W and total power of the driving system is 21.54W

  • PDF

A Study on the Design Standard of Demand Factor and Diversity Factor (건물의 수요율 및 부등율 기준설정에 관한 연구)

  • 지철근;곽희로;강원구
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.4 no.1
    • /
    • pp.54-62
    • /
    • 1990
  • This paper shows a reasonable design standard of Demand Factor and Diversity Factor for buildings, that was made by the systematic and statistical way considering actual conditions, such as investicated electric equipment capacity, electric power consumption, etc. The saving of electric equipment investment, the decrease of power loss, the improvement of facilities utilization and the decrease of electric power rates, can be contributed by the application of the design standard. The recommended design standard must be applied by the revision of current regulations and laws.

  • PDF

A Study on the Design Standard of Substation Facility Density and Demand Factor in Office Buildings (사무소용건물의 변전시설밀도 및 수용률 기준설정에 관한 연구)

  • 김세동;정동효
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.6
    • /
    • pp.42-48
    • /
    • 1992
  • This paper shows a reasonable design standard of substation facility density and demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, electric power consumption, etc for 121 buildings. The saving of electric equipment investment, the decrease of power loss, the improvement of facilities utilization and the decrease of electric power rates an be contributed by the application of the design standard must be applied by the revision of current regulations and laws.

  • PDF

Hybrid Double Direction Blocking Sub-Module for MMC-HVDC Design and Control

  • Zhang, Jianpo;Cui, Diqiong;Tian, Xincheng;Zhao, Chengyong
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1486-1495
    • /
    • 2019
  • Dealing with the DC link fault poses a technical problem for an HVDC based on a modular multilevel converter. The fault suppressing mechanisms of several sub-module topologies with DC fault current blocking capacity are examined in this paper. An improved half-bridge sub-module topology with double direction control switch is also designed to address the additional power consumption problem, and a sub-module topology called hybrid double direction blocking sub module (HDDBSM) is proposed. The DC fault suppression characteristics and sub-module capacitor voltage balance problem is also analyzed, and a self-startup method is designed according to the number of capacitors. The simulation model in PSCAD/EMTDC is built to verify the self-startup process and the DC link fault suppression features.

COMMON SHRIMP BEHAVIOUR TO PHYSICAL STIMULI AND THE FISHING GEAR DESIGN (II) (물리적 자극에 대한 보리새우의 행동과 어구 설계(II))

  • KO Kwan Soh;KIM Sang-Han
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 1971
  • In order to study the catching efficiency of shrimp trawl equipped with electrodes around the net mouth and stimulant devices attached to the ground rope, an experimental operation was carried out at Oma-Island Shrimp Farm from October 3rd to November 5th, 1970. Many studies have been made on the shrimp trawl with electric stimulant devices, but few can be found for detailed scientific catching methods. Electric power consumption was so excessive that electric stimulant devices could not be developed for commercial purposes. As a first step toward the successive operations of the electric stimulant devices in the field, it is necessary to study fundamental principles, such as electric current, voltage, electric potential, potential difference, electric field and suitable pulse. The behaviour response of the common shrimp, Penaeus japonicus BATE to moving nets and electric stimulant devices were reported in the preceding papers based on the water tank experiments (Ko and Kim, 1970). Through comparative fishing tests the rate of catching efficiency during daylight time was confirmed to be from 89 to 96 per cent of the night catch efficiency, and with 30 V. 1.5 A. electric power was sufficent for practical sea operation.

  • PDF

Energy Saving System using Occupancy Sensors and Smart Plugs (재실감지 센서와 스마트 플러그를 이용한 에너지 절약 시스템)

  • Jung, Kyung Kwon;Seo, Choon Weon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.10
    • /
    • pp.161-167
    • /
    • 2015
  • This paper presented an occupancy-based energy saving system for appliance energy saving in smart house. The developed system is composed of a sensing system and a home gateway system. The sensing system is set of wireless sensor nodes which have pyroelectric infrared (PIR) sensor to detect a motion of human and set of smart plugs which measure the current using CT (current transformer) sensor and send the current to home gateway wirelessly. We measured current consumption of appliances in real time using smart plugs, and checked the occupation of residents using occupancy sensors installed on the door and room. The proposed system saves electric energy to switch off the supply power of unnecessary usages in the unoccupied spaces. Experiments conducted have shown that electric energy usage of appliances can be saved about 34% checked by using occupation.

Development and Application of a Multimedia Title for Misconception Correction on Electric Current (전류에 대한 오개념 교정을 위한 멀티미디어 타이틀 개발 및 적용)

  • Kim, Ki-Ung;Lee, Sung-Keun;Lee, Choong-Il
    • The Journal of Korean Association of Computer Education
    • /
    • v.5 no.3
    • /
    • pp.117-126
    • /
    • 2002
  • Many students have some misconception on electric current, and they are not corrected easily by traditional instruction. In this paper, a multimedia title was developed for misconception correction on electric current, and applied to the students and investigated its effects. The subject of this study consists of 32 students of a middle school. The group is divided into two subgroups. the applied group and the compared group. each of which has 16 students. The achievement is estimated by t-test using SPSS. The result shows that current consumption concept was corrected easily and it had no relation with instruction methods. Educational multimedia title was especially effective in the class to correct the misconception of current distribution concept. It was difficult to correct current independent of resistance concept by the multimedia title.

  • PDF