• Title/Summary/Keyword: Electric Capacity

Search Result 1,250, Processing Time 0.039 seconds

Increase of resistive type superconducting fault current limiter capacity (박막 저항형 초전도 한류기의 용량증대를 위한 방안)

  • Cha, Sang-Do;Kim, H.R.;Choi, H.S.;Hyun, O.B.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.790-792
    • /
    • 2002
  • The resistive type superconducting fault current limiter(SFCL) is a current limiter using the Quench mechanism of superconductors. When Quench occurs in superconductors, the resistance of superconductors increases abruptly. In order to increase SFCL capacity, current limiting elements were connected in series. If the Quench current of each element was different, voltage distribution was imbalanced. This imbalance could be removed by arrangement including series and parallel connection of elements. Based on this result, an SFCL of 1.8kV/50A was designed and experimented, expecially, in terms of increasing the voltage rating.

  • PDF

Development of ultra high voltage-large capacity O.F cable (초고압 대용량 O.F 케이블의 개발)

  • Kang, S.H.;Lee, K.J.;Kim, C.S.;Choi, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.265-267
    • /
    • 1991
  • In this paper, we describe the development of 345kv OF cables to contain also the cable employing new insulation paper, PPLP (Poly propylene Laminated paper). The cables all show very excellent properties, especially PPLP cable has less the dielectric loss and better the impulse & A.C strength than the one employing the conventional paper. Therefore, according to use PPLP cable, it seems to be several advantages such as the compact of system, the increasing capacity, and the decreasing energy loss etc.

  • PDF

The improvement in operating rules of Cost Based Pool(CBP) considering the increasing Renewable Energy Capacity (신재생에너지 보급확대에 따른 국내전력시장 운영방안)

  • Lee, Jae-Gul;Nam, Su-Chul;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.580-583
    • /
    • 2008
  • As the construction of renewable energy generators is on the rise and gets bigger in size, researchers pay more and more attention to the impact of such facilities on the power market as well as on the stability of power grid system. In Korea, while studies on the latter, including calculating the marginal capacity of renewable energy generators, is being made, those on the former has not yet been performed. As such, this paper analyses the impact of a big renewable energy generators on the price and transaction cost of domestic power market and proposes ideas to minimize such influence by applying the technology of forecasting renewable energy.

  • PDF

Ultimate Pullout Capacity of Underreamed Anchors Using Electric Discharge in weathered soil (풍화토지반에서 전기방전에 의한 확공앵커의 극한 인발력)

  • Kim, Sung-Kyu;Kim, Nak-Kyung;Kim, Jae-Won;Kang, Byung-Chul;Kim, Tae-Hun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1354-1359
    • /
    • 2009
  • Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The anchor is an underreamed anchor by using high voltage electric discharge energy. In this study, a series of field test were carried out in order to find ultimate load of underreamed anchors in weathered soil at the new apartment construction site located in Inchon, Korea. Data were analyzed in order to define a relation between ultimate load and the number of electric discharge.

  • PDF

A study on the development of management system in electric culvert (지하전력구 감시제어시스템 개발연구)

  • 우희곤;이범석;이복규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.90-95
    • /
    • 1990
  • The long distance electric culvert employing power cable is using and increasing to improve reliability and Capacity of power supply in KEPCO. The purpose of this study in development of management system which used to security, maintenance, operation, and facility protection efficiently in electric culvert.

  • PDF

A Study of the Optimal Condenser Operation in Distribution System (배전선로의 적정 콘덴서 운용 연구)

  • Jeon, Young-Soo;Jang, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1238-1240
    • /
    • 1998
  • For economic operating of distribution system, utility has to minimize the loss in distribution line by controlling reactive power and power factor. This paper presents calculation of reactive power in distribution line, estimation of the condenser capacity according to distance, and computation of optimal location and proper condenser capacity.

  • PDF

Characterization of Potassium Based Dry CO2 Sorbents Developed for the Reduction of Side Reactions (부반응 저감 조성 K계 건식 CO2 흡수제 특성평가)

  • Jang, Young-shin;Kim, Ui-sik;Yoon, Yang-no;Baek, Jeom-In
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.337-341
    • /
    • 2019
  • In this study, the effects of two materials, active alumina and CaO based inorganic binder, which cause the side reaction on the K2CO3-based solid CO2 sorbents was investigated. K2CO3-based solid sorbents called KAM series was prepared by spray drying method and then measured its physical properties and CO2 sorption capacity. Among the KAM series sorbents, KAM(0.5) maintained high CO2 sorption capacity of 7.6 wt% after 3 cycle of sorption/regeneration reaction and showed very low attrition loss as low as 3.1 % which was measured by ASTM D5757-95.

Experimental Study on Combined Ocean Thermal Energy Conversion with Waste Heat of Power Plant

  • Jung, Hoon;Jo, Jongyoung;Chang, Junsung;Lee, Sanghyup
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.215-222
    • /
    • 2019
  • This work is experimental study of 10 kW specialized Combined Ocean Thermal Energy Conversion. We propose a C-OTEC technology that directly uses exhaust thermal energy from power station condensers to heat the working fluid (R134a), and tests the feasibility of such power station by designing, manufacturing, installing, and operating a 10 kW-pilot facility. Power generation status was monitored by using exhaust thermal energy from an existing power plant located on the east coast of the Korean peninsula, heat exchange with 300 kW of heat capacity, and a turbine, which can exceed enthalpy efficiency of 45%. Output of 8.5 kW at efficiency of 3.5% was monitored when the condenser temperature and seawater temperature are $29^{\circ}C$ and $7.5^{\circ}C$, respectively. The evaluation of the impact of large-capacity C-OTEC technology on power station confirmed the increased value of the technology on existing power generating equipment by improving output value and reducing hot waste water. Through the research result, the technical possibility of C-OTEC has been confirmed, and it is being conducted at 200 kW-class to gain economic feasibility. Based on the results, authors present an empirical study result on the 200 kW C-OTEC design and review the impact on power plant.

Thermal Characteristics of Electric Wiring for Halogen Warm Lamp Group and Automatic Waterer Group at Stable (우사(牛舍)에서의 할로겐보온등군(群) 및 자동급수통군에 대한 전기배선의 열적 특성)

  • Kim, Doo-Hyun;Yoo, Sang-Ok;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.48-53
    • /
    • 2014
  • This study is analyzed for electrical fire danger by electric equipments through surveys of stable owners and the field investigation at 64 stable. Also, an experiment is performed to analyze the thermal characteristics of 4 types electric wiring according to the number of operating halogen warm lamp group and automatic waterer group in Beon-young stable in the Cheongwon location. The survey is done to investigate the occurrence of electrical fire, electric equipment, causes and dangerous equipment. As a result, halogen warm lamp group and automatic waterer group are found to have dangerous loads. In the field investigation, the mode of load capacity of the halogen warm lamp group and automatic waterer group was investigated. The mode of load capacity of halogen warm lamp group (over 3 years) is found 17A and that of the auto waterer group (10 years) is 16A. In this experiment, the halogen warm lamp group aged at least 3 years showed $109^{\circ}C$ while that aged less than 1 year appeared $83^{\circ}C$, showing the max gap of $26^{\circ}C$. The automatic waterer group aged 10 years showed $90^{\circ}C$ while that aged less than 1 year appeared $68^{\circ}C$, showing the max gap of $22^{\circ}C$. These findings indicate that the mode of load capacity needs to be considered in selecting and installing wiring for the electric equipment construction of halogen warm lamp group and automatic waterer group in stable.