• Title/Summary/Keyword: Electric Block

Search Result 248, Processing Time 0.026 seconds

선박에 있어서의 내연기관구동발전기의 속도안정도에 관한 연구

  • 하주식;노창주
    • 전기의세계
    • /
    • v.24 no.4
    • /
    • pp.63-70
    • /
    • 1975
  • The speed characteristics of the diesel engines driving alternators are very important because it is directly concerned to the quality of electric power especially when electric power is supplied by a single alternator. In this paper, the speed characteristics of th diesel engine, equipped with a centrifugal mechanical governor, driving an alternator is dealt when load changes stepwise. The all coefficients included in the block diagram of the speed control system are estimated by actual experiments and the effects of gain change of the governor in the speed characteristics are examined theoretically and experimentally. The obtained result seems to be satisfactory and very useful for the improvement of quality of electric power supplied by a single alternator driven by the diesel engine especially for electric power system of ships.

  • PDF

Stress Analysis Acting on Electric Pole using Strain Gauge from Full Scale Pull-Out Test (실물인장실험시 변형률계를 이용한 전주에 작용하는 응력분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.49-55
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find stresses acting on concrete electric poles. The stresses of concrete poles are relaxed at 600~700[kg] of tensile load, and stresses are concentrated at top of pole, and spread to lower part of pole. In the concrete pole collapse test, tensile load at failure was approximately 1,400[kg], which is twice of design load. As passive zone in the soil increases, the stresses acting on concrete pole are concentrated at lower part of pole based on moment arm earth pressure distribution.

NSE-Sponsored Faculty Workshops on Teaching of Power Electronics and Electric Drives

  • Ned Mohan;Jain, Amit-Kumar
    • Journal of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.231-239
    • /
    • 2002
  • This paper describes the restructuring of power electronics and electric drives courses, sponsored by NSF, EPRI, NASA and the local utilities, which has significantly increased student enthusiasm, and the undergraduate enrollment in these courses at the University of Minnesota has tripled since 1997. The developed leaching approaches have been the subject of NSF-sponsored faculty workshops in 1994, 1997, 1998,2002, and 2003. In power electronics, the power-pole based building-block approach unifies analysis and control aspects of all converters. PSpice-based simulations aid in analysis and design, supported by a hardware laboratory. For electric drives, an integrative approach addressing all three aspects of electric drives - machines, power converters and control is being. used. Space vectors, introduced on a physical basis rather than purely mathematical ions, are used fur analysis of ac machines. This leads to a more physical understanding of machine operation and also makes it easier to address control aspects in the advanced course. The lecture materials are supported by a DSP-based laboratory.

Performance Improvement of Asynchronous Mass Memory Module Using Error Correction Code (에러 보정 코드를 이용한 비동기용 대용량 메모리 모듈의 성능 향상)

  • Ahn, Jae Hyun;Yang, Oh;Yeon, Jun Sang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.3
    • /
    • pp.112-117
    • /
    • 2020
  • NAND flash memory is a non-volatile memory that retains stored data even without power supply. Internal memory used as a data storage device and solid-state drive (SSD) is used in portable devices such as smartphones and digital cameras. However, NAND flash memory carries the risk of electric shock, which can cause errors during read/write operations, so use error correction codes to ensure reliability. It efficiently recovers bad block information, which is a defect in NAND flash memory. BBT (Bad Block Table) is configured to manage data to increase stability, and as a result of experimenting with the error correction code algorithm, the bit error rate per page unit of 4Mbytes memory was on average 0ppm, and 100ppm without error correction code. Through the error correction code algorithm, data stability and reliability can be improved.

A Study on Effect of Coating Stain on the Performance of Electric Cable (도장 오염이 Electric Cable의 성능에 미치는 영향 연구)

  • Cho, Yeon-Ho;Lee, Sang-Hyeok;Son, Young-Shuk
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2009.09a
    • /
    • pp.18-23
    • /
    • 2009
  • After the installation of electric cables at block, PE(pre-erection) and hull stages, the coating stains on the electric cable sheath were unavoidably occurred by additional painting process. According to class rules paint or coating applied on the electric cables shall not adversely affect the mechanical, chemical of fire resistant characteristics of the electric cable sheath. However, there has not been quantitatively studied about the effect of coating stains on properties of sheath materials. In this study, we tried to investigate the effect of coating stains on the performance and deterioration of sheath materials by using FTIR, SEM analysis, flame retardant, high potential voltage and tensile test. The results sowed that coating stains, which were occurred during painting work on site could not adversely affect on the performance and deterioration of sheath materials.

  • PDF

Optimal Block Matching Motion Estimation Using the Minimal Deviation of Motion Compensation Error Between Moving Regions (움직임 영역간 움직임 보상오차의 최소편차를 이용한 최적 블록정합 움직임 추정)

  • Jo, Yeong-Chang;Lee, Tae-Heung
    • The KIPS Transactions:PartB
    • /
    • v.8B no.5
    • /
    • pp.557-564
    • /
    • 2001
  • In general, several moving regions with different motions coexist in a block located on motion boundaries in the block-based motion estimation. In this case the motion compensation error(MCEs) are different with the moving regions. This is inclined to deteriorate the quality of motion compensated images because of the inaccurate motions estimated from the conventional mean absolute error(MAE) based matching function in which the matching error per pixel is accumulate throughout the block. In this paper, we divided a block into the regions according to their motions using the motion information of the spatio-temporally neighboring blocks and calculate the average MCF for each moving mentioned. From the simulation results, we showed the improved performance of the proposed method by comparing the results from other methods such as the full search method and the edge oriented block matching algorithm. Especially, we improved the quality of the motion compensated images of blocks on motion boundaries.

  • PDF

Performance Analysis of Gas Turbine for Large-Scale IGCC Power Plant

  • Joo, Yong-Jin;Kim, Mi-Yeong;Park, Se-Ik;Seo, Dong-Kyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.415-419
    • /
    • 2016
  • As the need for clean coal technology has grown, so has the global research and development efforts into integrated gasification combined cycle (IGCC) plants. An IGCC plant couples a gas turbine to a gasification block. Various technical and economic problems exist in designing such a system. One such problem is the difficulty in realizing economies of scale because the single-train flow capacity of commercial IGCC synthetic gas turbine plants is limited; the capacity does not exceed a net power rating of 300 MW. To address this problem, this study modeled and simulated a synthetic gas turbine with the goal of evaluating the feasibility of a 500 MW or larger IGCC plant. First, a gas turbine with the best output and efficiency was chosen for use with natural gas. The turbine was modeled using GateCycle (a simulation tool), and the integrity of the model validated by comparing the result to the design value. Next, off-design modeling was carried out for a gas turbine with synthetic gas based on its on-design model, and the result was compared with the study result of the gas turbine manufacturer. The simulation confirmed that it is possible to create a large capacity IGCC plant by undertaking the remodeling of a gas turbine designed to use natural gas into one suitable for synthetic gas.

An Authenticated Encryption Scheme without Block Encryption Algorithms (블록 암호 알고리즘을 사용하지 않는 인증 암호화 방법)

  • Lee, Mun-Kyu;Kim, Dong-Kyue;Park, Kunsun
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.29 no.5
    • /
    • pp.284-290
    • /
    • 2002
  • We propose a new authenticated encryption scheme that does not require any block encryption algorithm. Our scheme is based on the Horster-Michels-Petersen authenticated encryption scheme, and it uses a technique in the Bae~Deng signcryption scheme so that the sender's signature can be verified by an arbitrary third party. Since our scheme does not use any block encryption algorithm, we can reduce the code size in its implementation. The computation and communication costs of the proposed scheme are almost the same as those of the Bao-Deng scheme that uses a block encryption algorithm. Our scheme also satisfies all the security properties such as confidentiality, authenticity and nonrepudiation.

Control of Optical Hysteresis in Block Copolymer Photonic Gels: A Step Towards Wet Photonic Memory Films

  • Kim, Eun-Ju;Gang, Chang-Jun;Jang, Yu-Rim;Senthilkumar, S.;Gang, Yeong-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.279-279
    • /
    • 2010
  • Smart gels have recently associated with photonic crystals to form photonic gels. Since these photonic gels are capable of reversibly converting the volume change of gels induced in response to external chemical or electric stimuli into characteristic optical signals, they have been considered not only as a good platform for label-free chemical or biological detection, actuators or optical switches but also as a good model system to investigate gel swelling behaviour. Recently, we reported block copolymer photonic gels self-assembled from polystyrene-b-poly(2-vinyl pyridine) (PS-b-P2VP) block copolymers, and demonstrated that selective swelling of lamellar structure allows extremely large tunability of the photonic stop band from UV region to IR region ($\lambda$ peak=350~1,600 nm). Herein we report block copolymer photonic gels which exhibit strong tunable optical hysteresis and their applications. As nonlinear responses in swelling of hydrogels were often observed, photonic gels exhibit optical hysteresis with change of external pH. We demonstrate such optical hysteresis can be precisely programmed by controlling ion-pairing affinity. We anticipate that photonic gels with carefully tunned optical hysteresis are applicable to optical memory devices.

  • PDF