• Title/Summary/Keyword: Electric Block

Search Result 248, Processing Time 0.025 seconds

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.

Influence of Bioelectric Current on the Acupuncture: A Pilot Study - Focusing on the Effect of PC6 Against Heart Rate - (생체전류가 침 치료에 미치는 영향: 예비연구 - 심박수에 대한 내관(內關) 자침 효과를 중심으로 -)

  • Lee, Bong Hyo;Park, Ji Ha;Kim, Hee Young;Kim, Seong Rok;Park, Yeo Bin;On, Ye Jin;Lee, Seung Su;Lee, Chang Wook;Han, Soo Yeon;Lim, Sung Chul;Kim, Jae Soo;Lee, Yun Kyu;Lee, Hyun Jong;Jung, Tae Young;Lee, Sang Nam
    • Korean Journal of Acupuncture
    • /
    • v.30 no.3
    • /
    • pp.185-192
    • /
    • 2013
  • Objectives : Many studies have investigated the electric specificity of meridian and acupoint. However, the definition about the real substance of 'Ki(Qi)' that flows in the meridian has not been established yet. The authors hypothesized that the 'Ki(Qi)' may be the very 'bioelectricity' of western medicine, from two common features that they are not visible with naked eyes and that they function in the living body only. Methods : 20 healthy adults participated in this study. Heart rate was measured before and after exercise. Acupuncture was performed at PC6 immediately after exercise with counter balance in the first experiment. In the second experiment, acupuncture group was further divided to the three groups, i.e. glove acupuncture group, manual acupuncture group, and NaCl acupuncture group. In the glove group, acupuncturist put on the two folds of latex gloves to block bioelectric currents between the acupuncturist and subject. In the NaCl group, acupuncturist had his fingertips wet with NaCl solution. Results : Exercise increased Heart Rate and acupuncture at PC6 inhibited this increase. In the second experiment, the significant difference compared to the comtrol group was the most in NaCl acupuncture and the least in Glove acupuncture. However, there was no significant difference between three groups. Conclusions : The results of this study seem to be deficient as a conclusive evidence for the hypothesis that the 'Ki(Qi)' of Korean Medicine is the 'bioelectricity' of western medicine.

Effect on the Growth of Pllioblastus pygmaed and Soil Characteristics as Affected by Difference of Soil Thickness and Soil Mixture Ratio in the Shallow-Extensive Green Roof Module System (저관리 옥상녹화 모듈에서 토심, 배합비의 차이가 토양의 특성 및 흰줄무늬사사의 생육에 미치는 영향)

  • Park, Je-Hea;Ju, Jin-Hee;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.871-877
    • /
    • 2010
  • The objectives of this study were to compare growth of Pllioblastus pygmaed and soil characteristics as affected by difference of soil thickness and mixture ratio in shallow-extensive green roof module system, and to identify the level of soil thickness and mixture as suitable growing condition to achieve the desired plants in green roof. Different soil thickness levels were achieved under 15cm and 25cm of shallow-extensive green roof module system that was made by woody materials for $500{\times}500{\times}300mm$. Soil mixture ratio were three types for perlit: peatmoss: leafmold=6:2:2(v/v/v, $P_6P_2L_2$), perlit: peatmoss: leafmold=5:3:2(v/v/v, $P_5P_3L_2$) and perlit: peatmoss: leafmold=4:4:2(v/v/v, $P_4P_4L_2$). On June 2006, Pllioblastus pygmaed were planted directly in a green roof module system in rows. All treatment were arranged in a randomized complete block design with three replication. The results are summarized below. In term of soil characteristics, Soil acidity and electric conductivity was measured in pH 6.0~6.6 and 0.12dS/m~0.19dS/m, respectively. Organic matter and exchangeable cations desorption fell in the order: $P_4P_4L_2$ > $P_5P_3L_2$ > $P_6P_2L_2$. $P_6P_2L_2$ had higher levels of the total solid phase and liquid phase, and $P_4P_4L_2$ had gas phase for three phases of soil in the 15cm and 25cm soil thickness. Although Pllioblastus pygmaed was possibled soil thickness 15cm, there was a trend towards increased soil thickness with increased leaf length, number of leaves and chlorophyll contents in 25cm. The growth response of Pllioblastus pygmaed had fine and sustain condition in order to $P_6P_2L_2$ = $P_5P_3L_2$ > $P_4P_4L_2$. However, The results of this study suggested that plants grown under $P_4P_4L_2$ appear a higher density ground covering than plants grown under $P_6P_2L_2$. Collectively, our data emphasize that soil thickness for growth of Pllioblastus pygmaed were greater than soil mixture ratio in shallow-extensive green roof module system.

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

Comparison of screw-in effect of three NiTi file systems used by undergraduates (학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교)

  • Oh, Seung-Hei;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • The purposes of this study were to compare the apical terminus width of simulated curved root canal prepared with three NiTi file systems used by undergraduates for evaluation the effects of flute angle and pitch or radial land on reducing screw-in effect and to determine more safe NiTi file system for inexperienced operators. Fifty inexperienced undergraduate students prepared 150 simulated curved root canals in resin blocks with three NiTi file systems ; ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$. The electric motor set at a speed of 300 rpm and torque of 30 in a 16 : 1 reduction handpiece was used. The simulated root canal was prepared to ISO #25 sizes with each file system. The scanned images of pre- and post-instrumented canal of resin block were superimposed. To evaluate the screw-in effect of three NiTi file systems, apical terminus width of root canal was measured from superimposed images and statistical analysis was performed. There were significant differences in three NiTi flle systems. ProFile$^{(R)}$ had significantly smaller width than Hero Shaper$^{(R)}$ and K3$^{TM}$"" (P < 0.05), but no significant difference was observed between K3$^{TM}$ and Hero Shaper$^{(R)}$. Under the condition of this study, active file system (Hero SHaper$^{(R)}$, K3$^{TM}$) with variable pitch and helical angle had more screw-in effect than passive file system (ProFile$^{(R)}$) with constant pitch and helical angle. It seems that the radial lands play more important role in reducing screw-in effect.

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Surveying for Pig House Facilities of Pig Farms by Holding Scale (양돈농가의 사육규모별 축사시설 분석)

  • Seo, K.W.;Min, B.R.;Choi, H.C.;Lee, D.W.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.3
    • /
    • pp.231-240
    • /
    • 2009
  • In this research pig house facilities what are 3,029 houses hold over 1000 heads were surveyed by scale and province. Full-time farms hold over 1000 heads breed total 7,229,892 heads. And farms breed 2,386.9 heads averagely. Pig houses were constructed august 1995 averagely. Each of houses have $3,017.2\;m^2$ scale. The construction type of pig house was winch-curtain type 77.2% which was most popular, confined type 51.3%, litter type 7.4% and loft type 4.6%. The winch-curtain type was popular than windowless type in pig farms which have 1,000-1,999 heads. But pig house construction type which have more than over 10,000 heads was windowless type more than winch-curtain type. Manure removing type was slurry 72.3% and scraper 38.5% in farms which have 1,000-1,999 heads. Manure removing type was slurry 83.3% in farms which have over 10,000 heads. Proportion of roof type of pig house was slate 51.2%, panel 46.1%. But in middle or small farms, slate type was only 25.0%. Proportion of wall type of pig house was 41.9%, block 21.9%, concrete 7.6%, winch-curtain 6.3%, and bnck 5.9%. Ventilation type of pig house was natural winch 46.1%, mechanical windowless 69.8% and mixed type 53.1%. So, mechanical windowless type was popular than natural winch type. Especially the farm scale is bigger the mechanical widowless type was more. Utilization period of pig house was 8.1 years about automatic feeder, 8.3 years about waterer, 8.2 years about electric facilities and 9.0 years about floor material. Thus, almost of facilities were used at least 8 years.

  • PDF

Numerical Test for the 2D Q Tomography Inversion Based on the Stochastic Ground-motion Model (추계학적 지진동모델에 기반한 2D Q 토모그래피 수치모델 역산)

  • Yun, Kwan-Hee;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.3
    • /
    • pp.191-202
    • /
    • 2007
  • To identify the detailed attenuation structure in the southern Korean Peninsula, a numerical test was conducted for the Q tomography inversion to be applied to the accumulated dataset until 2005. In particular, the stochastic pointsource ground-motion model (STGM model; Boore, 2003) was adopted for the 2D Q tomography inversion for direct application to simulating the strong ground-motion. Simultaneous inversion of the STGM model parameters with a regional single Q model was performed to evaluate the source and site effects which were necessary to generate an artificial dataset for the numerical test. The artificial dataset consists of simulated Fourier spectra that resemble the real data in the magnitude-distance-frequency-error distribution except replacement of the regional single Q model with a checkerboard type of high and low values of laterally varying Q models. The total number of Q blocks used for the checkerboard test was 75 (grid size of $35{\times}44km^2$ for Q blocks); Q functional form of $Q_0f^{\eta}$ ($Q_0$=100 or 500, 0.0 < ${\eta}$ < 1.0) was assigned to each Q block for the checkerboard test. The checkerboard test has been implemented in three steps. At the first step, the initial values of Q-values for 75 blocks were estimated. At the second step, the site amplification function was estimated by using the initial guess of A(f) which is the mean site amplification functions (Yun and Suh, 2007) for the site class. The last step is to invert the tomographic Q-values of 75 blocks based on the results of the first and second steps. As a result of the checkerboard test, it was demonstrated that Q-values could be robustly estimated by using the 2D Q tomography inversion method even in the presence of perturbed source and site effects from the true input model.