• 제목/요약/키워드: Electric Appliances

검색결과 294건 처리시간 0.027초

국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사 (A survey on the EMF Levels of Study and Electric Appliances in Korea)

  • 장성기;조용성;이석조;유승화;정경미;임준호
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

가정용 전자기기의 잠재 상쇄 공급량 추정 (Estimation of Potential Supply of Offset from Household Electric Appliances)

  • 진현정;김정인;유은영;박서화
    • 자원ㆍ환경경제연구
    • /
    • 제24권3호
    • /
    • pp.463-488
    • /
    • 2015
  • 본 연구에서는 2015년부터 시행된 온실가스 배출권 거래제도에 맞추어 상쇄(offset)제도의 구체적인 설계가 필요한 시점에서, 가정부문의 고효율 전자기기의 보급을 통해 확보할 수 있는 잠재 상쇄 공급량을 추정하였다. 분석대상 품목은 TV, 세탁기, 선풍기, 냉장고, 에어컨 등 다섯 가지 가전기기이며, 자기회귀시차분포모형(ARDL)을 통해 2016년부터 2022년까지의 고효율 가전기기의 보급대수를 추정하고, 효율 개선을 통한 전기 절감량과 이에 따른 탄소 환산율을 통해 최종적으로 잠재 상쇄 공급량을 도출하였다. 고효율 가전기기의 에너지 절감률을 각각 10%와 20%로 가정했을 때 2022년에 누적된 탄소 저감량은 $361,899CO_2t$$723,797CO_2t$으로 나타났으며, 에너지 절감량이 큰 순서로는 에어컨, 냉장고, TV, 세탁기, 선풍기 순으로 나타났다. 또한 에너지 소비효율 1등급 가전기기의 에너지 절감률이 20%라고 가정했을 때, 누적 탄소 저감량이 2015년에 비해 2022년에 약 316% 증가하는 것으로 나타났다.

Power Consumption Pattern Analysis of Home Appliances for DC-based Green Smart Home

  • 서갑수;백종복;박철우;배현수;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.240-241
    • /
    • 2010
  • Research on modification and replacement of conventional AC distribution system to DC distribution system has been widely conducted. When DC system is applied, it is possible to improve energy transferring efficiency because most of the home appliances are electric loads which require DC input voltage. Furthermore, compatibility with renewable energy sources and secondary batteries should be improved as they are DC based power sources. To design energy efficient DC system, it is important to understand the load characteristics of the electric devices. In this paper, the electric appliances are classified to 3 types: motor, heating, and electric loads and their typical power consumptions are shown. Load patterns of load which can be used in analyzing the designed system are modeled according the statistics. Feasibility of the developed load patterns are verified by applying it in distribution system design tool.

  • PDF

가정.사무용 기기의 고조파 전류 측정 (The Measurement of the Harmonic Currents in the Household & Office Appliances)

  • 서장철;강용철;김성수;남순열;박종근;명성호;강영식;최효열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.149-151
    • /
    • 1996
  • This paper reports the measurement results of the harmonic currents in the household and office appliances. The harmonic currents of 10 items are measured up to 20th order using the no distortion source. These results can be used as a raw data in determining the harmonic current limit in the household and office appliances.

  • PDF

케이블 TV 전송선로의 특성 개선을 위한 접지방식 (Grounding method for Improving of the Characteristics on Cable TV Transmission Line)

  • 황종선;김영민;연제진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.37-40
    • /
    • 2002
  • Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in cable TV.

  • PDF

유통구조 변화가 소비자 행동에 미치는 영향에 관한연구-신유통업태 출현에 따른 가전제품 구매행동을 중심으로- (A Study of consumer behavior for electric appliance according to emergencing price-off store)

  • 문숙재;조성은;김연정
    • 가정과삶의질연구
    • /
    • 제16권1호
    • /
    • pp.13-26
    • /
    • 1998
  • The purpose of this study of identify the changing trends of consumer behavior to emergencing Price-off store. Therefore this study analyzed contributing factors to consumer market selection behavior focused on electric appliances. for these research the data were collected through the questionnaire and 407 respondents were housewives in Seoul and Gyeongi-do. Their data were analyzed using Frequency Mean and $x^2$-test. The Major findings of this study were as follows. 1) The percentage of purchasing the national brands of electric appliances were majority. In general the frequency prefered shopping store were the general agents department store discount store and wholesale club were in order. 2) When consumer buy the electric appliance in wholsesale club the buying percentage of iron was the highest. And the percentage of selection of foreign goods brands were very high. 3) The most important factors to determine the using Price-off store was the presence of this market around the housing and easing and easiness of parking.

  • PDF

TV 대기모드 효율기준 개발을 위한 대기전력 실태 분석 (Analysis of TV Standby Power for Development of Energy Efficiency Standard)

  • 김익표;노경수
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.18-26
    • /
    • 2012
  • Recently, there have been suggestions that power factor should be considered to increase the efficiency of electric power supply when evaluating the performance of the electric appliances in standby mode and the related studies have been conducted to improve the efficiency standard of standby power. But, they lack the analysis of the standby power characteristics with the changes of power factor. This study is conducted to analyze the standby power characteristics of TV which is a typical home appliance and reaches a conclusion that the apparent power can be a more reasonable index which reflects the efficiency of electric power supply. It is also found that LED TVs show the best performance in standby mode. Moreover, an example to set standby power standards on TVs to be applied in the future is suggested, considering the energy efficiency policies for appliances.

가정용 전력소비형태 분석을 위한 모니터링 프로그램 구현 (Implementation of the Monitoring Program for the Analysis of Electric Consumption Characteristics in Home Appliances)

  • 유원호;권혁대;최재혁;고성훈;전칠환;이성룡
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.547-549
    • /
    • 2008
  • This paper presents a implementation of the monitoring program for the analysis of electric consumption characteristics in home appliances, which uses a Labview program from National Instruments Corporation. It is can provide to be easy for small-scale researcher, development groups or individual researcher to analyze electric power consumption characteristics. Also, this paper apply to actual private home and then, analyze result of monitoring and a database result of power quality etc, like the power consumption form, power factor and harmonic which follow season, and time zone. For this measured the apartment where the family which is four lives in the object.

  • PDF