• Title/Summary/Keyword: Elbow arthroscopy

Search Result 162, Processing Time 0.022 seconds

Study for the Usefulness of Arthroscopic Repair with UU MA SB Stitch for the Full Thickness Rotator Cuff Tear (preliminary report) (회전근개 파열에서 관절경 감시하의 봉합술 - UU MA Suture Bridge를 이용한 봉합의 유효성(예비보고) -)

  • Ko, Sang-Hun;Lee, Seon-Ho;Rhee, Young-Girl;Lee, Chae-Chil
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • Purpose: To evaluate the clinical results of arthroscopic repair with Ulsan University - Mason Allen - Suture Bridge (UU MA SB) stitch for the full thickness rotator cuff tear. Materials and Methods: Fifteen patients with full thickness rotator cuff tear underwent arthroscopic repair with UU MA SB stitch between September 2010 and December 2010. Clinical and functional evaluations were made according to Korean shoulder score (KSS), American shoulder and elbow surgeon (ASES), University of California, Los Angeles (UCLA), visual anabgue scale (VAS) and the range of motion. Results: The mean KSS improved from 51.4 preoperatively to 92.0 at final follow-up (p<0.05). The mean UCLA score improved from 15.07 preoperatively to 31.93 postoperatively, the mean VAS of pain during the motion was 7.2 before treatment and 0.93 at final follow-up (p<0.001). At last follow-up, the mean range of motion was improved but they had not shown statistical significance (p>0.05). Conclusion: The arthroscopic repair with UU MA SB stitch may be an effective procedure in the full thickness rotator cuff tear for pain relief and improvement of the range of motion.

  • PDF

Impingement Syndrome & Rotator Cuff Tear: Etiology (견관절 충돌 증후군 및 회전근 개 파열의 병인)

  • Cho, Nam Su;Lee, Sang Hoon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.72-78
    • /
    • 2012
  • The rotator cuff is situated in a potential tight subacromial space and undergoes senescent structural changes commonly observed in other joints of the body. When the cuff fails, spontaneous healing of the torn tendon is not expected to occur, and multiple factors may be responsible. Its fibers are under tension and typically retract on tearing. The subacromial bursal inflammation and alterations in normal glenohumeral kinematics have been considered in the development of symptoms. Controversy continues to exist concerning the pathogenesis of rotator cuff disease. The heterogeneity of the disorder, as well as the notion that rotator cuff disease may not actually represent a continuum of the same process, but rather, is a compilation of independent disorders, may partly explain the differing viewpoints on its origin. Two contrasting pathogenetic mechanisms have been extensively described and include vascular, or intrinsic, causes and impingement, or extrinsic, factors. Other etiologies have also been reported that include trauma, congenital or developmental factors, and instability. For successful treatment of the rotator cuff diseases, it is essential to understand the structure and function of rotator cuff and to clarify the pathogenesis and natural history of its disorder.

  • PDF

What's New in Rotator Cuff Repair (회전근 개 파열 봉합술에서의 최신 지견)

  • Hwang, Jung-Taek;Kho, Duk-Hwan;Park, Jin-Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.98-103
    • /
    • 2012
  • The repair technique of rotator cuff tear has been markedly developed in recent years. When the natural history of rotator cuff tear was followed, the size of rotator cuff tear increased with time. The fatty infiltration which would come at the later period of rotator cuff tear and the rotator cuff tear arthropathy which would be occurred after massive rotator cuff tear may be the important factors in predicting the prognosis of rotator cuff tear or determining the timing of surgery. Because moderate supraspinatus fatty infiltration appeared an average of 3 years after onset of symptoms, the repair of rotator cuff tear was recommended to be performed before that. And if there was massive rotator cuff tear with cuff tear arthropathy, it was recommended that the rotator cuff repair should be performed before the occurrence of the narrowing of acromiohumeral interval. The techniques of arthroscopic rotator cuff repair were mainly the single row repair and the double row repair. The former is good in view of time consuming and cost, but the latter is superior in view of biomechanics. To maintain the benefit in biomechanics of double row technique and reduce the time of surgery, the suture-bridge technique was invented and widely used recently. There are several modified techniques in arthroscopic suture-bridge technique according to the characteristics of rotator cuff tear.

  • PDF

Arthroscopic Technique of Bone Defect in Anterior Shoulder Instability (골 결손이 동반된 전방 견관절 불안정성에서 관절경적인 수술 술기)

  • Ko, Sang-Hun;Park, Ki-Bong
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.102-108
    • /
    • 2009
  • Purpose: The bone defects that are associated with shoulder anterior instability may be the causes of failure of arthroscopic surgery. For the treatment of traumatic shoulder instability, we tried to determine the arthroscopic techniques that can be used for the bone defect of the glenoid and the humeral head. The purpose of this study is to assess the surgical techniques for the arthroscopic reconstruction of the shoulder with anterior instability and bone defects. Materials and Methods: We analyzed the articles that have been recently published on anterior shoulder instability and we assessed the arthroscopic surgical techniques. We compared the articles and the methods of arthroscopic surgical techniques for treating bone defects of the anteroinferior glenoid and the posterolateral humeral head, which were considered as the causes of recurrence of shoulder instability. Results: There are the anteroinferior bone defects of the glenoid and Hill-Sachs lesions in the bone defects that appear in patients with anterior shoulder instability. These bone defects are currently the causes of failure of arthroscopic surgery. Conclusion: Open shoulder surgery may be the treatment of the choice for a shoulder with instability and significant bone defects of the glenoid and the humeral head. But efforts are being made to overcome the weaknesses of open surgery by the use of arthroscopy.

Relationship Between Insertion Torque, and Pullout Strength Depending on the Size of the Pilot Hole and Biodegradable Suture Anchor in Osteoporotic Humeral Head (골다공증이 있는 상완골 골두의 파일럿 홀 (Pilot Hole)과 흡수성 나사못의 크기에 따른 토크 (Torque)와 뽑힘 강도 (Pullout Strength) 간의 관계)

  • Chun, Yong-Min;Lee, Young-Han;Kim, Sung-Hwan;Park, Yoo-Jung;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.8-15
    • /
    • 2012
  • Purpose: The object of this study was to investigate the difference in torque and pullout strength between the standard anchor insertion (5.0 mm) with a small awl (3.7 mm) and larger anchor insertion (6.5 mm), with a standard awl (5.0 mm) in osteoporotic humeral head. Materials and Methods: The embalmed 24 paired cadaveric shoulders were assigned to either Group A or B. After measuring the bone mineral density (BMD) of the ROI (region of interest) in the humeral head, 5.0 mm suture anchors were inserted using a 3.7 mm awl in Group A1, and the same 5.0 mm anchors were inserted using a 5.0 mm awl in Group A2. The 5.0 mm anchors were inserted using a 5.0 mm awl in Group B1, and 6.5 mm anchors were inserted using a 5.0 mm awl in Group B2. We measured the torques at the time of the anchor insertion and pullout strengths. Results: There was no significant difference in the BMD between the groups. The torque of A1 (20.6 $cN{\cdot}m$) was significantly higher than that of A2 (13.2 $cN{\cdot}m$), and the torque of B2 (20.8 $cN{\cdot}m$) was significantly higher than that of B1(12.1 $cN{\cdot}m$). However, the difference in the increased torque between group A and B was not significant. The pullout strength of A1 (204.2 N) was significantly higher than that of A2 (152.9 N), and the pullout strength of B2 (210.9 N) was significantly higher than that of B1 (149.5 N). However, the difference in the increased pullout strength between Group A and B was not significant. Conclusion: In severe osteoporosis, the use of a larger suture anchor with a standard awl increased the torque and pullout strength significantly, in comparison to the use of the same sized suture anchor and awl. If there is an inadequate interval between the anchors on the greater tuberosity, the use of a 3.7 mm awl and 5.0 mm anchor will be beneficial compared to that of a 5.0 mm awl and 6.5 mm anchor, considering that an increase in the pullout strength does not depend on the awl size.

Minimal Medial-row Tie with Suture-bridge Technique for Medium to Large Rotator Cuff Tears

  • Lee, Hyun Il;Ryu, Ho Young;Shim, Sang-Jun;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.4
    • /
    • pp.197-205
    • /
    • 2015
  • Background: The purpose of this study was to evaluate the postoperative magnetic resonance imaging (MRI) results of minimal-tying (one medial-row tie among 4 medial-row sutures) on the medial-row in double-row suture-bridge configuration ($2{\times}2$ anchor with $4{\times}4$ suture stands). Methods: From 2011 March to 2012 July, 79 patients underwent arthroscopic rotator cuff repair using $2{\times}2$ anchor double-row configuration. The mean age was 61.3 years (range, 31-81 years). Two double-loaded suture anchors were used for medial-row. Four medial-row stitches were made with only one medial-row knot-tying (the most anterior suture). Lateral-row was secured using the conventional suture-bridge anchor technique; all 4 strands were used for each anchor. Repair integrity was evaluated with MRI at mean 6.2 months postoperatively. Retear and the pattern of retear, change of fatty infiltration, and muscle atrophy of supraspinatus were evaluated using pre- and postoperative MRI. Results: Repaired tendon integrity was 38 for type I, 30 for type II, 6 for type III, 4 for type IV, and 1 for type V, according to Sugaya classification. Considering type IV/V as retear, the rate was 6.3% (5 out of 79 patients). Medial cuff failure was observed in 4 patients. Fatty atrophy of supraspinatus was significantly improved postoperatively according to Goutallier grading (p=0.01). The level of muscle atrophy of supraspinatus was not changed significantly after surgery. Conclusions: Minimal tying technique with suture configuration of four-by-four strand double-row suture-bridge yielded a lower retear rate (6.3%) in medium to large rotator cuff tears.

Arthroscopic Treatment in Calcific Tendinitis of the Shoulder (견관절 석회성 건염의 관절경적 치료)

  • Rhee Yong Girl;Kim Young Hwan;Park Moo Song
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.2
    • /
    • pp.68-74
    • /
    • 2000
  • The purpose of this study is to evaluate the final outcome after arthroscopic calcific removal in the calcific tendinitis of the shoulder joint and to analyze the influencing factors to affect the surgical treatment on the final results. From September, 1993 to March, 2000, arthroscopic removal of the calcific deposit in the shoulder joint was performed in 34 consecutive patients who had had typical symptoms and failed with the conservative treatment and 21 cases of 20 patients could be followed up at least 2 years. Fourteen cases(67%) were located in the supraspinatus, 5 cases(24%) in the infraspinatus and 2 cases(9%) in the subscapularis. Preoperative severity of symptoms was correlated with higher postoperative score. Pain was relieved from 7.6 to 0.9(Visual Analogue Scale:VAS) and UCLA score improved from 13.9 preoperatively to 32.0 postoperatively, but there was no statiscally significant difference in according to the deposit size(P=0.386). Pain and UCLA score improved from 7.9 to 0.4 and from 12.7 to 33.0 respectively when a calcific deposit was located in the supraspinatus, from 7.6 to 1.0 and from 14.8 to 33.4 in the infraspinatus but pain relieved from 6.5 to 4.0 and UCLA score improved from 20.0 to 22.5 in the subscapularis and these outcomes were shown a statiscal significance(P=0.001). Completeness of removal did not affect the final results(P>0,05). Excellent was 23.8% in 5 cases, good 66.7% in 14 cases, fair 4.8% in 1 and poor 4.8% in 1, and patients were satisfied with their final results in 81 %.

  • PDF

Beach-chair lateral traction position using a lateral decubitus distracter in shoulder arthroscopy

  • Kim, Kyung-Cheon;Rhee, Kwang-Jin;Shin, Hyun-Dae;Byun, Ki-Yong
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.164-164
    • /
    • 2008
  • The beach-chair traction position is designed to allow the use of traction while allowing the surgeon to orient the shoulder in an upright position and convert to an open procedure, if necessary. The patient is placed in the beach-chair position under general anesthesia. A three-point shoulder holder (Arthrex, Naples, Florida) is attached to the rail of the operating table on the same side as the surgeon, whereas it is placed on the side opposite the surgeon in the lateral decubitus position. A shoulder traction and rotation sleeve (Arthrex) are affixed to the arm following the manufacturer's instructions. Positioning the thumb toward the closed side of the sleeve ensures a field for the anterior portion of the rotator cuff and prevents the tendency of the suspension apparatus to place the arm in internal rotation. The arm is maintained in 30 to 40 degree abduction and 30 to 40 degree flexion by controlling the length and height of the bar and the location of the universal clamp. The universal clamp allows multiple planes of adjustment to control abduction and forward movement of the arm. The sleeve is attached to the longitudinal traction cable using a sterile hook, and a lateral strap is secured around the proximal portion of the sleeve to the overhead traction cable to ensure a field for glenohumeral reconstruction. The use of a lateral strap permits ideal shoulder positioning for improved access to the anterior and inferior glenohumeral joint. The lateral strap can be released or removed to widen the subacromial space during subacromial decompression or rotator cuff repair. A 10-lb weight is attached to the longitudinal traction cable for an average-sized person.

  • PDF

Advantages of Scorpion Suture Passer and 70 Degrees Arthroscope in Arthroscopic Bankart Repair: Usefulness for Inferior Labral Repair

  • Hyun, Yoon-Suk;Shin, Woo-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.201-207
    • /
    • 2017
  • Background: The blunted tip of a reusable with multiple uses can cause problems with the passing procedure in arthroscopic Bankart repair. This study assessed the advantage of Scorpion with a $70^{\circ}$ arthroscope in arthroscopic Bankart repair compared to hook typed suture passer. Methods: Scorpion in 19 patients, the hook type suture passer (conventional group) in 18 patients were used. All patients underwent the same procedure except for the type of suture passer used. Another different point of the procedure were telescopes and the number of portals used; three arthroscopic portals (posterior, anterorsuperiorlateral, and mid-anterior) and a $30^{\circ}$ arthroscope in the conventional group, but two portals and a $70^{\circ}$ arthroscope as well as the $30^{\circ}$ one in the Scorpion group. The surgery time and the surgical complications including an iatrogenic axillary nerve injury were recorded. Results: The Scorpion group showed a significant decrease in surgery time compared to the conventional group. In contrast to the conventional group, Scorpion provided an easy estimation of the exit of suture passing, no iatrogenic labral injury during the passing procedure with straight movement and the sharp tip of the knife installed. Iatrogenic supraspinatus injuries could be avoided when making an accessory anteosuperiorlateral portal due to the $70^{\circ}$ arthroscope. Conclusions: In arthroscopic Bankart repair, the use of the Scorpion suture passer and a $70^{\circ}$ arthroscope can reduce the surgery time, avoid unnecessary supraspinatus injury, and avoid iatrogenic axillary nerve damage through the relatively easy and precise suture passing and saving of the anterosuperior portal.

Use of Massive Cuff Stitch in Arthroscopic Repair of Rotator Cuff Tears (관절경 하 회전근 개 파열의 봉합에서 광범위 근개 봉합법의 이용)

  • Ko, Sang-Hun;Cho, Sung-Do;Gwak, Chang-Youl;Eo, Jin;Yoo, Chang-Hyun;Choe, Seung-Wan
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.181-188
    • /
    • 2006
  • Purpose: To evaluate the integrity of repair & technical tip in use of Massive Cuff Stitch at arthroscopic repair of rotator cuff tear. Materials and Methods: Twenthy-nine cases of arthroscopically repaired full thickness tear of rotator cuffs which are medium sized were evaluated. Between December 2004 to September 2005 we have studied, the average age 53($42{\sim}69$) years old, mean follow-up was 15($12{\sim}21$) months. We analyzed the results statistically by paired t-test. The integrity of repair were verified by follow up MRI which were checked 11 cases and ultrasound which were checked 10 cases. Results: VAS of pain improved preoperative average 7.1 to postoperative 0.9, ADL improved 11.2 to 25.6 respectively, UCLA improved 13.7 to 32.9(all, P<0.05). 89.7% showed excellent & good results at the final follow-up. The satisfied rate was 93.1%(27 cases). There was re-rupture of the repaired rotator cuff in one case out of 11 cases which were checked by MRI, and in one case out of 10 cases which were checked by ultrasound, and there was one case of thinning of cuff which were checked by ultrasound. Conclusion: The use of Massive Cuff Stitch in arthroscopic repair of rotator cuff tear have been reduced technical failure. It will be good surgical technique which maintain the integrity of repairs.