• Title/Summary/Keyword: Elastic modulus

Search Result 1,985, Processing Time 0.026 seconds

A Study on the Determination of Setting Time of Concrete in the Determination of Slip-up Speed for Slip-Form System (슬립폼 시스템 상승속도 결정에 요구되는 콘크리트에서의 초기경화시간 결정을 위한 연구)

  • Kim, Heeseok;Kim, Young-Jin;Chin, Won-Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4A
    • /
    • pp.295-302
    • /
    • 2011
  • The setting time which is the important element for the determination of slip-up speed of Slip-Form system is the hardening time of early-age concrete when the in place concrete has minimum compressive strength before the concrete appears out of Slip-Form system. But it is very difficult to predict the setting time because it depends on not only the composition ratio of concrete but also various conditions of construction fields. Thus, the technique to estimate accurately and continuously the hardening time of early-age in place concrete during operating Slip-Form system is necessary to guarantee the safety of Slip-Form system and the maintenance of the shape of concrete. Ultrasonic wave-based nondestructive testing methods have the advantages which are accurate and continuous in estimating concrete compressive strength. Of such methods, the method using surface wave which propagates along the surface of material is effective for thick member such as a pylon. Thus, in this paper a study on the determination of slip-up speed for Slip-Form system using surface wave velocity is performed. The relation between the slip-up speed of Slip-Form system and the setting time is formulated, and the surface wave velocity is estimated from continuous wavelet transform of the numerical results for surface wave propagation. Finally, the accuracy of this method according to the distance between the wave source and receivers and the relation between the estimated surface wave velocity and the elastic modulus are investigated.

Compressive Stress Distribution of High Tension Bolted Joints (고장력 볼트 이음부의 내부 압축응력 분포)

  • Kim, Sung Hoon;Lee, Seung Yong;Choi, Jun Hyeok;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.171-179
    • /
    • 1997
  • The high-tension bolted joints are clamped by the axial force which approaches the yielding strength. The introduced axial force is transmitted to the connection members pass through washer. The transferred load in connections is balanced to the compressive stress of plates, axial force in bolts and the external loads. In this mechanism, the compressive stress and slip load we dominated by the effective stiffness of bolted joints and plates. In general the effective stiffness is specified to product to the effective area and elasticity modulus in connections. In this reason, the conic projection formular which is assumed that the axial force in bolts is distributed to the cone shape and that region is related to the elastic deformation mechanism in connections, was proposed. But it conclude what kind of formula is justified. Therefore in this paper, the fatigue tests are performed to the high tension bolted joints and inspected to the phase on the friction face. And using the FEM and numerical method, it is analyzed and approximated to the compressive stress distribution and its region. Moreover, it is estimated to the effective area and to the relation the friction area to the effective compressive distribution region.

  • PDF

A Study on Analysis and Design Improvement of Opening Angle of Duct Cap of Ice Dispenser for Refrigerator (냉장고 얼음 디스펜서 덕트 캡의 개방각도 해석 및 설계개선에 관한 연구)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.672-680
    • /
    • 2018
  • The opening angle of the duct cap assembly during the operation of a refrigerator ice dispenser was evaluated by transient structural analysis, and an improved design to maximize the opening angle was obtained. The opening angle of the existing design was found to be 78% of the upper limit. Several design modifications were proposed and analyzed to examine the effects of the design factors on the opening angle. As a result of the design modifications, the opening angle was improved by changing the lever material to a material with a high elastic modulus, moving the position of the support to the motor side, or increasing the lever shaft diameter. Considering the manufacturing cost of the new design, the design modification changing only the lever material was found to be the best because it does not require a change in the structure of the ice dispenser case. In conclusion, the opening angle can be improved by up to 95% of the upper limit value if the lever material is changed to an aluminum alloy. The methods and results presented in this study were found to be of great help in designing the duct cap assembly structure to facilitate the discharge of ice.

Comparative study on dynamic properties of argillaceous siltstone and its grouting-reinforced body

  • Huang, Ming;Xu, Chao-Shui;Zhan, Jin-Wu;Wang, Jun-Bao
    • Geomechanics and Engineering
    • /
    • v.13 no.2
    • /
    • pp.333-352
    • /
    • 2017
  • A comparison study is made between the dynamic properties of an argillaceous siltstone and its grouting-reinforced body. The purpose is to investigate how grout injection can help repair broken soft rocks. A slightly weathered argillaceous siltstone is selected, and part of the siltstone is mechanically crushed and cemented with Portland cement to simulate the grouting-reinforced body. Core specimens with the size of $50mm{\times}38mm$ are prepared from the original rock and the grouting-reinforced body. Impact tests on these samples are then carried out using a Split Hopkinson Pressure Bar (SHPB) apparatus. Failure patterns are analyzed and geotechnical parameters of the specimens are estimated. Based on the experimental results, for the grouting-reinforced body, its shock resistance is poorer than that of the original rock, and most cracks happen in the cementation boundaries between the cement mortar and the original rock particles. It was observed that the grouting-reinforced body ends up with more fragmented residues, most of them have larger fractal dimensions, and its dynamic strength is generally lower. The mass ratio of broken rocks to cement has a significant effect on its dynamic properties and there is an optimal ratio that the maximum dynamic peak strength can be achieved. The dynamic strain-softening behavior of the grouting-reinforced body is more significant compared with that of the original rock. Both the time dependent damage model and the modified overstress damage model are equally applicable to the original rock, but the former performs much better compared with the latter for the grouting-reinforced body. In addition, it was also shown that water content and impact velocity both have significant effect on dynamic properties of the original rock and its grouting-reinforced body. Higher water content leads to more small broken rock pieces, larger fractal dimensions, lower dynamic peak strength and smaller elastic modulus. However, the water content plays a minor role in fractal dimensions when the impact velocity is beyond a certain value. Higher impact loading rate leads to higher degree of fragmentation and larger fractal dimensions both in argillaceous siltstone and its grouting-reinforced body. These results provide a sound basis for the quantitative evaluation on how cement grouting can contribute to the repair of broken soft rocks.

Numerical analysis of blast-induced anisotropic rock damage (터발파압력에 기인한 이방성 암반손상의 수치해석적 분석)

  • Park, Bong-Ki;Cho, Kook-Hwan;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.4
    • /
    • pp.291-302
    • /
    • 2004
  • Blast-induced anisotropic rock damage around a blast-hole was analyzed by a using numerical method with user-defined subroutine based on continuum damage mechanics. Anisotropic blasting pressure was evaluated by applying anisotropic ruck characteristics to analytical solution which is a function of explosive and rock properties. Anisotropic rock damage was evaluated by applying the proposed anisotropic blasting pressure. Blast-induced isotropic rock damage was also analyzed. User-defined subroutines to solve anisotropic and isotropic damage model were coded. Initial rock damages in natural ruck were considered in anisotropic and isotropic damage models. Blasting pressure and elastic modulus of rock were major influential parameters from parametric analysis results of isotropic rock damage. From the results of anisotropic rock damage analysis, blasting pressure was the most influential parameter. Anisotropic rock damage area in horizontal direction was approximately 34% larger and about 12% smaller in vertical direction comparing with isotropic rock damage area. Isotropic rock damage area under fully coupled charge condition was around 30 times larger than that under decoupled charge condition. Blasting pressure under fully coupled charge condition was estimated to be more than 10 times larger than that of decoupled charge condition.

  • PDF

Evaluating Shear Wave Velocity of Rock Specimen Through Compressional Wave Velocities Obtained from FFRC and Ultrasonic Velocity Methods (양단자유공진주 및 초음파속도법으로 획득한 압축파 속도를 이용한 암석시편의 전단파 속도 도출)

  • Bang, Eun Seok;Park, Sam Gyu;Kim, Dong Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.4
    • /
    • pp.250-256
    • /
    • 2013
  • Using shear wave velocity is more reasonable to estimate strength and integrity of rock compared with using compressional wave. It is often ambiguous to pick the dominant frequency caused by torsional wave when evaluating $V_S$ of rock specimen from FFRC method. It is also sometimes ambiguous to pick the first arrival point of S wave compared with P wave in the signals acquired from ultrasonic velocity method. Otherwise, the procedure of evaluating $V_P$ using ultrasonic velocity method and $V_L$ using FFRC method is relatively stable. Through the relationship between elastic modulus, poisson's ratio and $V_S$ can be obtained from $V_P$, $V_L$. Applicability was checked using model specimens having different material property and length and rock specimens sampled in mine area, and usefulness of proposed procedure was verified.

Effect of Nanocellulose and Aminated Starch on Tensile and Thermal Properties of Plasticized Starch Film (가소화 전분필름의 강도 및 열적 성질에 미치는 나노셀룰로오스 및 아민화전분의 첨가영향)

  • Kim, Bo-Yeon;Han, Song-Yi;Lee, Sung-Yong;Kim, Young-Kyoon;Kim, Nam-Hun;Lee, Seung-Hwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.376-384
    • /
    • 2014
  • This study investigated the effect of nanocellulose, such as microfibrillated cellulose (MFC) and cellulose nanocrystal (CNC), and aminated starch on tensile property and thermal stability of plasticized starch film. Glycerol (23 wt%) was used as a plasticizer and nanocelluloses of 1-30 parts per hundred parts of resin (phr) in the basis of plasticized starch were added. Tensile strength and elastic modulus increased with increasing nanocellulose addition amount, whereas elongation at break decreased. Tensile properties of MFC-reinforced starch film were higher than those of CNC-reinforced film. Optimum addition amount of aminated starch, which is commonly used for paper sizing, to improve tensile property of film, was found to be 5%. And 1% addition of aminated starch showed the best effect in the improvement of tensile property of the film. Thermal stability was improved with the addition of MFC to plasticized starch film with and without aminated starch.

Buckling Analysis using Fictitious Axial Forces and Its Application to Cable-Stayed Bridges with HSB800 Steel (가상축력을 이용한 좌굴해석 및 HSB800 강재를 적용한 사장교에 대한 적용성 분석)

  • Choi, Dong Ho;Yoo, Hoon;Gwon, Sun Gil;Lim, Ji Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.1
    • /
    • pp.13-24
    • /
    • 2017
  • System buckling analysis is usually used to determine the critical buckling load in the buckling design of cable-stayed bridges. However, system buckling analysis may yield unexpectedly large effective lengths of the members subjected to a relatively small axial force. This paper proposes a new method to determine reasonable effective lengths of girder and tower members in steel cable-stayed bridges using fictitious axial forces. An improved inelastic buckling analysis with modified tangent modulus is also presented. The effective lengths of members in example bridges calculated using the proposed method are compared with those obtained using the conventional buckling analysis method. The proposed method provides much more resonable effective lengths of the members. When girder and tower members are built with HSB800 steel instead of conventional steel, the effective lengths of the members under a small axial force slightly decreases in the inelastic buckling analysis without fictitious axial forces, while the proposed method that considers fictitious axial forces provides almost no changes in such lengths.

Measurement of Mechanical Properties of Thin Film Materials for Flexible Displays (플렉서블 디스플레이용 박막 소재 물성 평가)

  • Oh, Seung Jin;Ma, Boo Soo;Kim, Hyeong Jun;Yang, Chanhee;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.3
    • /
    • pp.77-81
    • /
    • 2020
  • Commercialization of flexible OLED displays, such as rollable and foldable displays, has attracted tremendous interest in next-generation display markets. However, during bending deformation, cracking and delamination of thin films in the flexible display panels are the critical bottleneck for the commercialization. Therefore, measuring mechanical properties of the fragile thin films in the flexible display panels is essential to prevent mechanical failures of the devices. In this study, tensile properties of the metal and ceramic nano-thin films were quantitatively measured by using a direct tensile testing method on the water surface. Elastic modulus, tensile strength, and elongation of the sputtered Mo, MoTi thin films, and PECVD deposited SiNx thin films were successfully measured. As a result, the tensile properties were varied depending on the deposition conditions and the film thickness. The measured tensile property values can be applied to stress analysis modeling for mechanically robust flexible displays.

Evaluation on Strain Properties of 60 MPa Class High Strength Concrete according to the Coarse Aggregate Type and Elevated Temperature Condition (60MPa급 고강도 콘크리트의 굵은골재 종류와 고온상태에 따른 변형특성 평가)

  • Yoon, Min-Ho;Choe, Gyeong-Cheol;Lee, Tae-Gyu;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.247-254
    • /
    • 2014
  • Strain properties of concrete member which acts as an important factor in the stability of the concrete structure in the event of fire, significantly affected the characteristics of the coarse aggregate, which accounts for most of the volume. For this reason, there are many studies on concrete using artificial lightweight aggregate which has smaller thermal expansion deformation than granite coarse aggregate. But the research is mostly limited on concrete using clay-based lightweight aggregate. Therefore, in this study, the high temperature compressive strength and elastic modulus, thermal strain and total strain, high temperature creep strain of concrete was evaluated. As a result, remaining rate of high-temperature strength of concrete using lightweight aggregate is higher than concrete with general aggregate and it is determined to be advantageous in terms of structural safety and ensuring high-temperature strength from the result of the total strain by loading and strain of thermal expansion. In addition, in the case of high-temperature creep, concrete shrinkage is increased by rising loading and temperature regardless of the type of aggregate, and concrete using lightweight aggregate shows bigger shrinkage than concrete with a granite-based aggregate. From this result, it is determined to require additional consideration on a high temperature creep strain in case of maintaining high temperature like as duration of a fire although concrete using light weight aggregate is an advantage in reducing the thermal expansion strain of the fire.