• 제목/요약/키워드: Ejection

검색결과 706건 처리시간 0.03초

갑상선기능항진증(甲狀線機能亢進症)에서 좌심실용적(左心室容積) 및 기능변화(機能變化)에 관한 연구(硏究) (Effects of Thyroid Hormone on Left Ventricular Volume and Function in Hyperthyroidism)

  • 이명철;고창순
    • 대한핵의학회지
    • /
    • 제17권2호
    • /
    • pp.1-17
    • /
    • 1983
  • The purpose of this study is to investigate the effects of thyroid hormone on the left ventricular(LV) volume arid function in man with untreated hyperthyroidism and to determine the effects of successful therapy for thyrotoxicosis on the ventricular pathophysiology. In the present study, equilibrium radionuclide cardiac angiography was performed and LV volume index, ejection phase indexes of LV performance, serum thyroid hormone levels and other hemodynamic parameters were measured in 28 normal subjects and 39 patients with hyperthyroidism before treatment and again every 4 weeks for the first 2 months after the initiation of effective therapy. The results obtained were as follows; 1) In the untreated hyperthyroid state heart rate, blood volume, cardiac index and stroke volume index($97{\pm}14$ beats/min, $73.5{\pm}11.8ml/kg,\;6.9{\pm}1.4\;l/min/m^2$ and $77.6{\pm}13.8ml/m^2$, respectively) were increased significantly compared to those in normal control($74{\pm}12beats/min$, $66.6{\pm}14.8ml/kg,\;3.8{\pm}1.2\;l/min/m^2$ and $56.6{\pm}13.2ml/m^2$ respectively). $(Mean{\pm}SD)$ 2) There was a significant increase in LV end-diastolic volume index in patients with hyperthyroidism ($30.5{\pm}7.5$ for hyperthyroid group compared to a normal control of $22.2{\pm}6.5$; p<0.001), whereas end-systolic volume index remained unchanged $9.6{\pm}3.6\;and\;8.8{\pm}3.3$ respectively).3) In patients with hyperthyroidism, LV ejection fraction was $70.0{\pm}5.6%$, fractional shortening $32.9{\pm}5.1%$, mean velocity of circumferential fiber shortening(mean Vcf) $1.34{\pm}0.31$ circ/sec and maximum ejection rate $3.47{\pm}0.80$. All the ejection phase indexes were significantly greater than those in normal control($65.2{\pm}5.7%,\;28.8{\pm}3.2%,\;0.88{\pm}0.37$ circ/see and $2.27{\pm}0.50$, respectively; p<0.001). 4) Effective therapy produced significant decrease in all the values of serum thyroid hormone concentrations(p<0.00l), hemodynamic parameters(p<0.001), end-diastolic volume index(p<0.01) and ejection phase indexes of LV contractility in patients with hyperthyroidism and after one to two months, when the patients were euthyroid, these measurements were in the range of normal. 5) A significant linear correlation between mean Vcf and serum thyroxine level(r=0.63, p<0.001) as well as between mean Vcf and serum triiodothyronine level(r=0.62, p<0.001) was found. The lesser degree of correlation was also noted between other ejection phase indexes and serum thyroid hormone concentrations. The results indicate that the major effects of excess thyroid hormone on the LV in human beings with hyperthyroidism are an enhancement of LV function and an increase in LV enddiastolic volume and that these effects cause predictable reversible cardiac alteration which are changed dramatically and immediately after effective therapy.

  • PDF

공기분사가 모돈과 포유자돈의 압사 관련 행동에 미치는 영향 (Effect of Air Ejection on the Behaviors of Sows and their Piglets Related to the Crushing of Piglets by Sows)

  • 전중환;연성찬;장홍희
    • Journal of Animal Science and Technology
    • /
    • 제47권4호
    • /
    • pp.691-696
    • /
    • 2005
  • 본 연구는 모돈이 서있거나 앉아 있을 때 모돈의 배 밑에 공기를 분사하는 것이 모돈과 포유자돈의 압사 관련 행동에 미치는 영향을 규명하고자 수행되었으며, 공시동물로는 경산돈 16복과 포유자돈 179두가 분만 후 4일까지 이용되었다. 모돈의 행동을 관찰한 결과, 서있는 행동과 앉아있는 행동에 있어서 대조구와 공기분사구간에 차이가 없는 것으로 나타나 공기분사가 모돈의 행동에 영향을 미치지 않는 것으로 분석되었다. 반면에 압사와 밀접하게 관련 있는 4가지 포유자돈의 행동을 관찰한 결과 모돈의 뒤로 지나가는 행동, 모돈의 뒤에 서있는 행동, 모돈의 배 밑으로 지나가는 행동, 모돈의 배 밑에 서있는 행동 모두가 대조구에 비해 공기분사구에서 현저히 낮게 나타났다. 따라서, 모돈이 서있거나 앉아있을 때 모돈의 배 밑에 공기분사를 함으로써 모돈의 행동과 포유자돈의 건강에 영향을 미치지 않고 포유자돈의 압사 관련 행동을 억제하여 포유자돈의 압사를 효과적으로 방지할 수 있을 것으로 예상된다.

만성폐쇄성폐질환 환자의 호흡곤란 평가에서 우심실 박출계수의 의의 (Right Ventricle Ejection Fraction Contributes Severity of Dyspnea in Chronic Obstructive Pulmonary Disease (COPD))

  • 이정은;민보람;박재석;박훈표;전미정;원경숙;최원일
    • Tuberculosis and Respiratory Diseases
    • /
    • 제60권6호
    • /
    • pp.631-637
    • /
    • 2006
  • 배 경: 만성폐쇄성폐질환 환자의 호흡곤란은 일반적으로 폐활량에 반비례하나 유사한 폐기능에서도 서로 다른 호흡곤란을 호소한다. 본 연구는 만성폐쇄성폐질환 환자에서 우심실박출계수와 호흡곤란의 정도와 연관관계가 있는지를 알아보고자 한다. 방 법: 호흡곤란의 정도는 Medical Research Council (MRC) 호흡곤란척도로 분석하였고, MRC 4/5도인 중증군 24명과, MRC 2/3도인 중등증군 16명을 비교 분석하였다. 심전도게이트 일회통과법을 이용한 방사성동위원소 심조영술을 이용하여 우심실 박출계수를 구했으며, 안정시 동맥가스분석 및 폐기능검사를 시행하였다. 결 과: 기저 폐기능에서 잔기량의 예측치 평균이 (%) 중증군에서($210{\pm}87$) 중등증군($160{\pm}27$)에 비해 유의하게 증가되었으나(P < 0.03), 폐활량 및 확산계수 등에서는 유의한 차이가 관찰되지 않았다. 우심실 박출계수(%)는 중증군에서($25{\pm}8$) 중등증군($35{\pm}6$)에 비해 유의하게 감소되었으나(P < 0.001), 동맥혈가스는 두 군 사이에 유의한 차이가 관찰되지 않았다. 다중회귀분석을 통해 우심실 박출계수가 독립적으로 호흡곤란에 영향을 미치는 인자로 밝혀졌다. 결 론: 만성폐쇄성폐질환에서 우심실 박출계수가 호흡곤란의 정도에 영향을 미치는 것으로 보인다.

디지탈 혈관 조영상에서의 좌심실 경계 자동검출을 이용한 심박출 계수의 측정 (A Measurement of Heart Ejection Fraction using Automatic Detection of Left Ventricular Boundary in Digital Angiocardiogram)

  • 구본호;이태수
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권2호
    • /
    • pp.177-188
    • /
    • 1987
  • Detection of left ventricular boundary for the functional analysis of LV(left ventricle) is obtained using automatic boundary detection algorithm based on dynamic program ming method. This scheme reduces the edge searching time and ensures connective edge detection, since it does not require general edge operator, edge thresholding and linking process of other edge detection methods. The left ventricular diastolic volume and systolic volume were computed after this automatic boundary detection, and these volume data were applied to analyze LV ejection fraction.

  • PDF

사출성형용 금형의 기능 및 구조에 대한 고찰 (Introduction to Plastic Injection Molds)

  • 허영무
    • 소성∙가공
    • /
    • 제11권8호
    • /
    • pp.641-650
    • /
    • 2002
  • For the production of complicated plastic parts in a cycle, a mold is needed.. The basic tasks of a mold are accommodation and distribution of the resin, shaping and cooling the melt and ejection of the molding. To achieve these goal a mold has several important parts and we classified types of molds. The 6 different major functions of a mold are explained and several types of molds are shown in her. I hope these explanation will help to understand injection molds for a design engineer.

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.

사출성능 개선을 위한 사출용 가스발생기 연구 (Research on the Ejection Gas Generator to Improve Ejecting Performance)

  • 오석진;장승교;차홍석
    • 한국항공우주학회지
    • /
    • 제41권5호
    • /
    • pp.383-390
    • /
    • 2013
  • 유도탄의 사출성능 중 탄에 충격으로 작용하는 최대가속도의 감소는 유도탄의 비정상작동 방지와 내부 부품들의 크기 및 비용 감소 측면에서 매우 중요하다. 본 연구에서는 사출용 가스발생기의 작동에 의해 탄에 가해지는 최대가속도가 사출초기에 발생됨을 착안하여 사출초기에 영향을 미치는 설계인자를 조사하였다. 가스발생기 설계인자로 점화기 및 노즐마개를 선정하고, 설계인자 변경을 통해 가스발생기에 의해 발생되는 최대가속도를 실험적으로 조사하였다. 최종적으로 최대가속도 감소효과를 정량적으로 비교하기 위해 가스발생기 지상연소시험을 실시하였다. 그 결과 설계인자의 최적값들이 적용된 개선모델의 경우 기준모델에 비해 최대가속도를 약 68% 줄일 수 있음을 확인하였다.

심전도와 심탄도의 무구속적 동시 측정을 위한 의자 등받이 개발 (Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG)

  • 임용규
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.104-109
    • /
    • 2018
  • 심전도와 심탄도를 무구속적으로 동시에 측정하는 시스템을 개발하였다. 제안된 시스템은 의자의 보조 등받이에 설치되어 맥파전달시간(PAT), Pre-ejection period (PEP) 등의 심혈관계 역학 정보를 일상생활에서 무구속적으로 측정하는 것을 목적으로 개발되었다. 본 연구에서는, 의자의 등받이에 부착된 용량성 능동전극과 용량성 접지를 이용한 간접접촉 심전도 (IDC-ECG) 측정 방법에 의해 무구속적으로 심전도를 측정하였으며, 등받이에 부착된 EMFi 압력 센서를 사용하여 무구속적으로 심탄도(ballistocardiogram)를 측정하였다. 제안된 시스템으로 심전도와 심탄도가 무구속적으로 동시에 측정됨을 확인하였으며, 측정된 심탄도는 피검자 사이에서 일정한 패턴을 보이는 것을 알 수 있었다. 또한 심전도의 Q파와 심탄도의 첫 번째 첨두간의 시간차가 pre-ejection period와 높은 상관관계를 보이는 것도 확인할 수 있었다. 이 연구에서 개발된 시스템은 심혈관계의 다양한 지표(심전도, 심박수, PAT, PEP 등)를 무구속적으로 일상생활에서 측정할 수 있음을 보였다.

코발트계 극박형 비정질합금의 형성과 자기적 성질 (Fabrication and Magnetic Properties of Ultrathin Co-based Amorphous Alloy)

  • 노태환
    • 한국자기학회지
    • /
    • 제8권5호
    • /
    • pp.255-260
    • /
    • 1998
  • 두께 10$\mu\textrm{m}$ 이하의 코발트계 극박형 비정질합금의 진공중 용탕급냉방법에 의한 제조조건과 자기적 특성에 대해 연구되었다. 구리 냉각롤의 회전 선속도를 55 m/s로 하였을 때, 0.05 kgf/cm2 이하의 용탕분사압 조건에서 극박형 리본이 얻어졌다. 합금 두께는 용탕분사 가스압력의 감소에 비례하여 직선적으로 감소하였으며, 이와 동시에 폭의 감소도 함께 일어났다. 이는 극박형 합금을 만들기 위해 용탕분사압을 극단적으로 감소시키면 노즐구의 양단부에서 용융금속과 노즐 사이의 마찰효과가 크게 나타나 유효분사압이 현저히 감소하는 데에 기인하는 것으로 해석되었다. 저주파(1 kHz) 실효투자율은 대략 2차 함수의 관계로 리본 두께의 감소에 따라 저하되었다. 반면 보자력은 두께의 감소에 반비례하여 증가하였는데, 이들 현상은 거의 전적으로 표면효과의 증대에 의한 자벽이동의 억제에 그 원인이 있는 것으로 판단되었다. 그러나 고주파(1 MHz) 실효투자율은 두께의 감소에 따라 증가하였는바 이는 와전류 발생이 억제되어 자기장 방향으로의 자화회전이 보다 용이해지기 때문으로 생각되었으며, 결과적으로 극박화에 의해 MHz 대역에서 우수한 저손실 성질을 나타내는 자심 특성의 실현이 가능하였다.

  • PDF

냉각제의 분사조건 및 상변화가 혼합가스 사출시스템의 성능에 미치는 영향 (Effect of Heat Transfer and Phase Change of Coolant on the Performance of Mixed-gas Ejection System)

  • 김현묵;김정수
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.84-93
    • /
    • 2018
  • 냉각제 분사조건이 변화할 때 혼합가스 사출시스템 (또는 가스-스팀 발사체계) 냉각효율 및 발사체 사출성능의 변화를 확인하기 위해 3차원 수치모사를 수행하였다. 선행연구를 참조하여 구축한 1차원 모델을 통해 3차원 단상(single-phase) 계산모델을 검증한 후, Discrete Phase Model을 활용하여 고온의 기체에 냉각제 분사를 모사한 이상(two-phase) 유동 계산을 수행하였다. 냉각제 유량과 분사구 개수를 각각 변화시키면서 계산을 수행한 결과, 분사구 개수를 증가시켰을 경우 냉각효율이 보다 개선되었다. 또한 분사조건에 따라 냉각제 액적 서로간의 coalescence 발생 빈도 및 공간분포 변화가 발생하여 액적의 직경이 달라졌고, 이는 냉각제 증발률에 영향을 미쳤다. 냉각제의 증발은 breech 내부의 온도를 감소시키는 반면에 압력감소를 억제하여 사출시스템 최적화 설계에 있어 중요한 요소임을 확인하였다.