• Title/Summary/Keyword: Effluent concentration

Search Result 795, Processing Time 0.025 seconds

Characteristics of Pollutant Concentration from Livestock Wastewater Effluent Combined with Stormwater Runoff (강우시 및 건기시 축산지역에서 배출되는 오염물질의 유출특성 비교)

  • Tobio, Jevelyn Ann S.;Maniquiz-Redillas, Marla C.;Lee, Yuwha;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.896-901
    • /
    • 2012
  • In this research, the levels of concentrations from the junction of effluent from wastewater treatment plant during dry days and combined with runoff from the surrounding 11 ha livestock catchment area during wet days were determined to investigate the relationships of the concentration of various pollutants such as particulates, nutrients and organics originating from point and nonpoint sources. Manual sampling was conducted from October 2008 to December 2011 during dry and wet days. Based on the results, the flow rates and concentrations of most pollutant parameters were increased during wet days. It was found out that the effluent wastewater combined with stormwater runoff has low BOD to TN/TP ratio and high TN/TP to BOD ratio. Therefore, it is needed to employ other treatment methods to effectively manage the wastewater and reduce the pollutant discharge to receiving water bodies.

Spatial Characterization of Water Pollution in the Urban Stream Watershed (Gap Stream), Korea (도시하천(갑천) 유역에서 수질오염의 공간적 특성)

  • Lee, Heung-Soo;Hur, Jin;Jeong, Seon-A;Hwang, Soon-Jin;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.943-951
    • /
    • 2006
  • Spatial distribution of water pollution in the Gap Stream was investigated from October to November, 2005. Sampling was conducted three times including effluents discharged from a wastewater treatment plant (WWTP) and a dam reservoir during the low-flow period. As a typical urban stream, total nitrogen and inorganic nitrogen concentrations increased toward downstream. Ammonia concentration was the highest in the treated water of the wastewater treatment plant and the lowest nitrate concentration was found in the effluent of the dam reservoir. A part of soluble reactive phosphorous (SRP) in total phosphorous was 22~54% in the upstream reach of WWTP in the Gap Stream whereas 68~73% in the downstream reach. Mean chlorophyll-a concentration ranged from 1.6 to $11.0{\mu}g/L$ and it tends to increase toward downstream except for WWTP effluent. As expected, untreated wastewater and WWTP effluent were suggested as the major sources of water pollution in the Gap Stream. In this study, the water pollution of the Gap Stream is a significant undergoing typical eutrophication, caused by excessive phosphorus and nitrogen nutrients from WWTP located in the watershed. As a result, the critical factor for the water pollution was evaluated to dissolved inorganic nitrogen and phosphorus nutrients. Particularly, SRP is a most important for the eutrophication. It suggest that may occur in the most urban streams of Korean peninsula. Therefore, because the necessity of water pollution management in the urban stream, inorganic N and P nutrients should be included as an essential component of water quality criteria in the advanced water quality project of Korean Government by enforcing of water quality assessment and total maximum daily loads (TMDLs).

Development of Alternative External Carbon Source from Wasting Carbonaceous Organic Resource and Full Scale Application (유기폐자원을 이용한 고도하수처리 대체탄소원 개발 및 실플랜트 적용)

  • Jung In Chul;Kim Ho Young;Kang Dong Hyo;Jung Joung Soon;Lee Sang Won;Lim Keun Taek;Kim Chang Won
    • Journal of Environmental Science International
    • /
    • v.13 no.10
    • /
    • pp.911-919
    • /
    • 2004
  • The purpose of this research was evaluated economical effect to apply alternative external carbon source. Conventional activated sludge process in municipal wastewater treatment plant was adapted and introduced to Biological nutrient removal processes to meet the newly enforced effluent quality standard for nutrient removal in Korea. Low $COD/NH_4^+-N$ ratio and higher nutrient concentration of influent characteristics force to inject external carbon source for denitrifying recycled nitrate. In the most case, methanol was used as external carbon source. But Methanol is expensive and very dangerous in handling. So we could find cheaper and safer external carbon source substituted methanol in last study. This alternative external carbon source is named RCS(recoverd carbon source) and a by-product of fine chemical product at chemical plant. When RCS was applied real municipal wastewater treatment plant, average $55\~65\%$ of T-N removal efficiency, 8.8mg/l of effluent T-N concentration, 11.3mg/l of effleunt COD concentration were obtained without effluent COD increase as against used methanol. To apply RCS in municipal wastewater treatment plant obtain approximately $\74.5%$ expenditure cost reduction in comparison with methanol dosage cost.

Changes in BOD, COD, Chlorophyll-a and Solids in Aquaculture Effluent with Various Chemical Treatments

  • Park, Jeonghwan;Daniels, Harry V.
    • Journal of Marine Life Science
    • /
    • v.2 no.2
    • /
    • pp.49-55
    • /
    • 2017
  • Four chemical treatments with hydrogen peroxide (H2O2), copper sulfate (CuSO4), potassium permanganate (KMnO4) and chlorine (Cl2) were applied to the effluent pond water of a hybrid striped bass saltwater recirculating aquaculture system to compare their oxidation power. Four chemicals were applied at concentrations of 0 (control), 1, 5, 10 and 20 mg/l. An additional concentration of 40 mg/l was included in the chlorine treatment. Water samples from four hybrid striped bass ponds were tested with KMnO4 and Cl2. H2O2 did not reduce any of BOD, COD and chlorophyll-a, and copper sulfate was only effective on chlorophyll-a for the effluent pond. Removal efficiencies for chlorophyll-a by copper sulfate were 19.2%, 37.5%, 54.2% and 74.1% dose-dependently. Potassium permanganate effectively removed the BOD, COD and chlorophyll-a. The COD removal rates in four fish ponds varied from 15.9% to 31.6% at the concentration of 10 mg/l. Interestingly, Cl2 did not reduce the BOD and COD at all, but the BOD and COD instead increased drastically with increasing the Cl2 concentration. The pond water with the highest initial BOD and COD values among the fish ponds tested increased by 350% in the BOD and 150% in the COD at 20 mg/l. Furthermore, Cl2 did not significantly reduce any types of solid matter in this study, while KMnO4 seemed to reduce some extent volatile dissolved solid in the fish pond.

Optimal Operation Condition of Livestock Wastewater Treatment Using Shortcut Biological Nitrogen Removal Process (단축질소제거 공정을 이용한 가축분뇨의 적정 처리조건 연구)

  • Jin-Young Kang;Young-Ho Jang;Byeong-Hwan Jeong;Yeon-Jin Kim;Yong-Ho Kim
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.5
    • /
    • pp.390-395
    • /
    • 2023
  • The feasibility of applying the shortcut nitrogen removal process to treat livestock wastewater on individual farms was examined, and appropriate operating parameters were established. As a result,, it was determined that the nitrification reaction was carried out under 550 mg/L of ammonium nitrogen concentration, but it was less effective under conditions of high ammonia concentration. Consequently, it was confirmed that a partial injection of inflow water was necessary to minimize the effects of ammonia toxicity. Following the sequential batch reactor (SBR) operation results, it was difficult to achieve the effluent quality standard without an external carbon source. Also, selection of the appropriate hydraulic retention time was critical for the optimal SBR operation. Following the livestock farm application, with external carbon source injecting, the total nitrogen concentration in the effluent was 85.1 mg/L. This result revealed that the standard could be accomplished through a single treatment on individual livestock farms. The ratio of nitrite nitrogen to ammonia nitrogen in the effluent was verified to be suitable for implementing the anammox process with a 10 days of hydraulic retention time. This study demonstrated the potential applicability of process in the future. However, in order to apply to livestock farms, managing variations in wastewater load across individual farms and addressing reduced nitrogen oxidation efficiency during the winter season are crucial.

Ecotoxicity Assessment of 1,4-Dioxane and Dichloromethane in Industrial Effluent Using Daphnia magna (물벼룩을 이용한 산업방류수 중 1,4-다이옥산 및 디클로로메탄의 생태독성평가)

  • Choi, Jae Won;Lee, Sun Hee;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.466-471
    • /
    • 2019
  • 1,4-dioxane and dichloromethane are classified as carcinogenic groups in the International Agency for Research on Cancer (IARC). They are frequently released at high concentrations in an industrial wastewater effluent. The acute toxicity (24 h) of Daphnia magna for 7.53 mg/L of 1,4-dioxane in the industrial effluent was evaluated as 1.1 TU (toxic unit) and showed TU close to the effluent quality standard. Mixed substances of 1,4-dioxane and dichloromethane in the industrial effluent showed relatively high TU as compared to that of a single substance. Half maximal effective concentration (24 h $EC_{50}$) values of 1,4-dioxane and dichloromethane for the synthetic wastewater prepared in laboratory were 1,744 (0.06 TU) and 170 mg/L (0.6 TU), respectively and the toxicity was low. Nevertheless the toxicological evaluation of the mixture showed that TU values increased to 0.02, 0.04 and 0.10, respectively as 1, 5 and 10 ppm of dichloromethane was added to 100 ppm of 1,4-dioxane. And the synergistic effect was observed between two substances. But the TU value of synthetic wastewater was below 5%, lower than that of industrial effluent at the similar concentration.

Control of Wastewater Treatment Removing Phosphate Based on ASM No. 2 Simplified Model and Investigation of Luxury Uptake Limitation (ASM No. 2 간략화 모델에 기초한 인산염의 제어 및 인섭취 제한현상에 대한 고찰)

  • Kim, Shin-Geol;Choi, In-Su;Koo, Ja-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.181-189
    • /
    • 2008
  • Phosphate is the limiting factor leading to the eutrophication in nature and has been usually removed by the luxury uptake of PAOs(Phosphate accumulating organisms). The purpose of this study was the control of wastewater treatment removing phosphorus. The control of wastewater treatment process was performed by optimal and adaptive control. They were performed as followings. Firstly the inflow phosphate concentration was measured and the optimal aeration time was calculated by simplified ASM No. 2 for the phosphate to be 1.0 mg/L in effluent. It was optimal control. But when the phosphate concentration in effluent was not 1.0 mg/L, adaptive control was necessary to coincide the objective of control with real value. Then it was performed as the objective phosphate concentration in effluent was changed according to calculation of errors and it was adaptive control. The wastewater treatment process had been controlled by them for about one month. The range of phosphate concentration in effluent 0.2$\sim$3.2 mg/L and the average of it was 1.0 mg/L. The limitation of luxury uptake occurred two times while wastewater treatment process was running. After the analysis of laboratory tests, we knew the reasons were the shortage of ammonia nitrogen and the excessive aeration.

A Study on the Applicability of PDA Technique in the P-CAP System for T-P Removal of STP Effluent (하수처리장 방류수의 총인 제거를 위한 P-CAP 시스템에서 PDA 기법의 활용가능성에 대한 연구)

  • Choi, Choongho;Maeng, Sungkyu;Sim, Jaehwi;Choi, Jinho;Song, Kyungguen;Lee, Byungha;Cha, Hoyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.729-742
    • /
    • 2012
  • Recently, to using chemical coagulation process for T-P removal in STP effluent as tertiary treatment process is generalized in the country. The importance of analysis technique to save the treatment & maintenance cost during coagulation process is becoming more increased each day. Thus, it is necessary for the analysis technique during coagulation process to be presented well the characteristic of coagulation in field apply. There are a few analysis techniques such as Jar Test, zeta potential analysis and streaming current detecting techniques. But there are difficult to apply in field immediately due to long test time and difficult analysis techniques. And using PDA technique, it is reviewed applicability of the techniques as field index on pilot plant of P-CAP system The P-CAP system is composed of an in-line static mixer, a Flocculation Tank and the CAP reactor with 2 stage weir for effluent. Pre-test is performed to fix the mixing velocity in the Flocculation Tank using the PDA equipment and it fixed with 30RPM. Also, Jar Test is performed to select optimum dose of each coagulant for each T-P concentration level of influent. Result of continuous test on pilot plant of P-CAP system, the FSI in the Flocculation Tank is increased consistently by increasing each dosing concentration of coagulant such as LAS and PAC in the low level influent T-P concentration comparatively. It is considered that formed Al-hydroxide complexes for dosed coagulant are caused FSI variation. Furthermore, it seems that FSI value in the high level influent T-P concentration appeared lower than the opposite influent condition relatively because it is formed simultaneously Al-hydroxide complexes as solid type and Al-phosphorus complexes as soluble type. Thus, relation of FSI by PDA technique and T-P removal of final effluent on pilot plant of P-CAP system are very limited for the kind of coagulant and the characteristics of influent. And it though that FSI value by PDA technique with analyzing of turbidity in Flocculation Tank will be used restrictedly on field as the relative field-index.

Basic Study for Development of Denitrogenation Process by ion Exchange(II) (이온교환법에 의한 탈질소 공정개발의 기초연구(II))

  • 이민규;주창식
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.89-95
    • /
    • 1998
  • Ion exchange performance to remove nitrate in water was studied using commercially available strong base anion exchange resin of Cl- type in the batch and continuous column reactors. The performance was tested using the effluent concentration histories for continuous column or equilibrium conquilibrium between resin and solution. Anion exchange resin used in this study was more effective than activated carbon or zeolite for nitrate removal. With large resin amount or low initial concentration, nitrate removal characteristics for a typical gel-type resin was Increased. On considering the relation between the breakthrough capacity and nitrate concentration of the influent, the use of anion exchange resin were suitable for the hi선or order water treatment. The nitrate removal of above 90% could be possible until the effluent of above 650 BV was passed to the column. Thus, the commercially available strong base anion exchange resin of $Cl^-$ type used in thins study could be effectively used as economic material for treatment of the groundwater. The breakthrough curves showed the sequence of resin selectivity as $SO_4^{2-}$ > $NO_3$ > $NO^{2-}$ > $HCO_3^-$. The results of this study could be scaled up and used as a design tool for the water purification system of the real groundwater and surface water treatment processes.

  • PDF

Stoichiometric Study for Nitrogen Removal in Anoxic-oxic Process (무산소-산소 공정에서 양론적 질소제거 연구)

  • Lee, Byung-Dae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1222-1227
    • /
    • 2005
  • Optimal sludge recycling ratio for maximum total nitrogen(TN) removal efficiency was calculated stoichiometrically using nitrification and denitrification reaction with given influent water qualities in anoxic-oxic process which was one of the popular nitrogen removal system. The water quality items for stoichiometric calculation were ammonia, nitrite, nitrate, alkalinity, COD, and dissolved oxygen which could affect nitrification and denitrification. Optimal sludge recycling ratio for maximum TN removal efficiency was expressed by those five influent water qualities. TN concentration calculated stoichiometrically had kept good relationship with reported TN concentration in each tank and final effluent. In addition, it was possible to expect the TN concentration in final effluent by stoichiometric calculation within ${\pm}5.0\;mg/L$.