• 제목/요약/키워드: Efficient seismic analysis technique

검색결과 20건 처리시간 0.026초

An efficient seismic analysis technique for PCSG assembly using sub-structuring method and homogenization method

  • Gyogeun Youn;Wanjae Jang;Gyu Mahn Lee;Kwanghyun Ahn;Seongmin Chang
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2120-2130
    • /
    • 2024
  • This study significantly reduced the seismic analysis time of PCSG assembly by introducing a reduced model using homogenization and sub-structuring methods. The homogenization method was applied to the primary and secondary micro-channel sheets, and the sub-structuring method was applied to the PCSG module sets. Modal analysis and frequency response analysis were then performed to validate the accuracy of the reduced model. The analysis results were compared with the full model and it was confirmed that the reduced model provided almost the same analysis results as the full model. To verify the computational efficiency of the reduced model, the computational time was then compared with the full model, and it was confirmed that the modal analysis time was reduced by 3.42 times and the frequency response analysis time was reduced by 4.59 times.

Simulation based improved seismic fragility analysis of structures

  • Ghosh, Shyamal;Chakraborty, Subrata
    • Earthquakes and Structures
    • /
    • 제12권5호
    • /
    • pp.569-581
    • /
    • 2017
  • The Monte Carlo Simulation (MCS) based seismic fragility analysis (SFA) approach allows defining more realistic relationship between failure probability and seismic intensity. However, the approach requires simulating large number of nonlinear dynamic analyses of structure for reliable estimate of fragility. It makes the approach computationally challenging. The response surface method (RSM) based metamodeling approach which replaces computationally involve complex mechanical model of a structure is found to be a viable alternative in this regard. An adaptive moving least squares method (MLSM) based RSM in the MCS framework is explored in the present study for efficient SFA of existing structures. In doing so, the repetition of seismic intensity for complete generation of fragility curve is avoided by including this as one of the predictors in the response estimate model. The proposed procedure is elucidated by considering a non-linear SDOF system and an existing reinforced concrete frame considered to be located in the Guwahati City of the Northeast region of India. The fragility results are obtained by the usual least squares based and the proposed MLSM based RSM and compared with that of obtained by the direct MCS technique to study the effectiveness of the proposed approach.

1:12축소 10층 철근콘크리트 골조-벽식 구조의 비선형 거동에 대한 실험과 해석의 상관성 (Correlation of Experimental and Analytical Inelastic Responses of A 1:12 Scale 10-Story Reinforced Concrete Frame-Wall Structure)

  • 이한선;김상호
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.119-126
    • /
    • 2000
  • Reinforced concrete structural walls are widely known to provide an efficient lateral load resistance and drift control. However, many reported researches on them are mostly limited to the RC structural walls reinforced according to seismic details. When the pushover analysis technique is used for the prediction of inelastic behavior of frame-wall structures for the seismic evaluation of existing buildings having non-seismic details, the reliability of this analysis method should be checked by the test results. The objective of this study is to verify the correlation between the experimental and analytical responses of a high-rise reinforced concrete frame-wall structure having non-seismic details by using DRAIN-2DX program[11] and the test results performed previously[1]. It is concluded that the behavior of the frame-wall model is mainly affected by the fixed-end rotation(uplift at base) and bending deformation of the wall and that the analysis with the LINKS model[10] in DRAIN-2DX describes them with good reliability.

슬림형 바닥시스템을 이용한 고층 복합구조의 내진성능에 관한 해석적 연구 (Analysis of Seismic Performance of Slim Flat Plate System in High-rise Hybrid Structural System)

  • 하기주;박효선;박중현;최경렬;김대중;정재광
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.77-80
    • /
    • 2005
  • Recently the construction of high-rise hybrid type building is progressively increased as the social demands. It is significantly important factors such as economy, the safety of structure, and the flexibility of internal space. Therefore new hybrid structural system, using slim flat plate system, is also required to be attained the reduction of story height, the flexibility and efficient use of space. The most suitable structural system is ,with the economy and flexibility, flat plate system in high-rise hybrid type building. But it was focused in the seismic performance for high performance flat plate system in high-rise hybrid type building. Therefore, in the study, to develop the new flat-plate system with high ductile, durable, good performance for the applications. It was evaluated the seismic performance in the critical region of slab-column connection. And then high performance flat plate system, designed by the economy and safety, was developed as a new technique in the application of high-rise hybrid type building.

  • PDF

주상 복합 구조물에 적용된 중간층 면진 시스템의 성능 검토 (Control Performance Evaluation of Mid-Story Isolation System for Residence-Commerce Complex Building)

  • 박광섭;김윤태;김현수
    • 한국공간구조학회논문집
    • /
    • 제19권3호
    • /
    • pp.33-40
    • /
    • 2019
  • A seismic isolation system is one of the most effective control devices used for mitigating the structural responses due to earthquake loads. This system is generally used as a type of base isolation system for low- and mid-rise building structures. If the base isolation technique is applied to high-rise buildings, a lot of problems may be induced such as the movement of isolation bearings during severe wind loads, the stability problem of bearings under large compression forces. Therefore, a mid-story isolation system was proposed for seismic protection of high-rise buildings. Residence-commerce complex buildings in Korea have vertical irregularity because shear wall type and frame type structures are vertically connected. This problem can be also solved by the mid-story isolation system. An effective analytical method using super elements and substructures was proposed in this study. This method was used to investigate control performance of mid-story isolation system for residence-commerce complex buildings subjected to seismic loads. Based on numerical analyses, it was shown that the mid-story isolation system can effectively reduce seismic responses of residence-commerce complex tall buildings.

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

On the progressive collapse resistant optimal seismic design of steel frames

  • Hadidi, Ali;Jasour, Ramin;Rafiee, Amin
    • Structural Engineering and Mechanics
    • /
    • 제60권5호
    • /
    • pp.761-779
    • /
    • 2016
  • Design of safe structures with resistance to progressive collapse is of paramount importance in structural engineering. In this paper, an efficient optimization technique is used for optimal design of steel moment frames subjected to progressive collapse. Seismic design specifications of AISC-LRFD code together with progressive collapse provisions of UFC are considered as the optimization constraints. Linear static, nonlinear static and nonlinear dynamic analysis procedures of alternate path method of UFC are considered in design process. Three design examples are solved and the results are discussed. Results show that frames, which are designed solely considering the AISC-LRFD limitations, cannot resist progressive collapse, in terms of UFC requirements. Moreover, although the linear static analysis procedure needs the least computational cost with compared to the other two procedures, is the most conservative one and results in heaviest frame designs against progressive collapse. By comparing the results of this work with those reported in literature, it is also shown that the optimization technique used in this paper significantly reduces the required computational effort for design. In addition, the effect of the use of connections with high plastic rotational capacity is investigated, whose results show that lighter designs with resistance to progressive collapse can be obtained by using Side Plate connections in steel frames.

지반가속도의 시뮬레이션과 강기반상(剛基盤上)에 설치된 회전측-베어링계의 지진해석 (Simulation of Seismic Ground Accelerations and Seismic Analysis of Flexible Rotor-Bearing System Housed on the Rigid Base)

  • 김기봉
    • 대한토목학회논문집
    • /
    • 제9권4호
    • /
    • pp.51-61
    • /
    • 1989
  • 비선형 거동을 일으키는 구조물의 불규칙 진동해석이나 운동방정식이 매개여기와 비제차 여기를 포함하는 능동장비의 동적해석에는 불규칙 진동분야에서 보편적으로 사용되는 스펙트럼해법의 적용이 불가능하다. 만약 불규칙 입력하중을 인공적으로 시뮬레이션 할 수 있다면 이러한 문제들은 운동방정식에 직접적분법을 적용하여 동적응답을 얻을 수 있다. 본 논문에서는 FFT기법을 이용하여 비정상 불규칙 지반가속도를 시뮬레이션하는 효과적이고 실제적인 방법을 제시하며, 이렇게 얻은 인공지진을 응용하는 문제로서 지진하충을 받는 회전축-베어링계의 동적응답을 시뮬레이션하였다. 또한 시뮬레이션기법의 적용성 및 실용성을 검토하기 위한 민감도에 대한 연구도 제시하였다.

  • PDF

동특성 민감도 해석을 이용한 전단형 철골구조물의 다목적 다단계 최적설계 (Multi-Objective and Multi-Level Optimization for Steel Frames Using Sensitivity Analysis of Dynamic Properties)

  • Cho, Hyo-Nam;Chung, Jee-Seung;Min, Dae-Hong;Kim, Hyun-Woo
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.333-342
    • /
    • 1999
  • An improved optimization algorithm for multi-objective and multi-level (MO/ML) optimum design of steel frames is proposed in this paper. In order to optimize the steel frames under seismic load, two main objective functions need to be considered for minimizing the structural weight and maximizing the strain energy. For the efficiency of the proposed method, well known multi-level optimization techniques using decomposition method that separately utilizes both system-level and element-level optimizations and an artificial constraint deletion technique are incorporated in the algorithm. And also dynamic analysis is executed to evaluate the implicit function of structural strain energy at each iteration step. To save the numerical efforts, an efficient reanalysis technique through sensitivity analysis of dynamic properties is unposed in the paper. The efficiency and robustness of the improved MOML algorithm, compared with a plain MOML algorithm, is successfully demonstrated in the numerical examples.

  • PDF

굴절파 GRM 해석방법을 응용한 고경사 단층 인지(Ⅰ) - 컴퓨터 모델링 연구 - (Identification of high-dip faults utilizing the GRM technique of seismic refraction method(Ⅰ) - Computer modeling -)

  • 김기영
    • 지구물리
    • /
    • 제2권1호
    • /
    • pp.57-64
    • /
    • 1999
  • 지표 부근의 수직변위 단층을 굴절파 자료로부터 신속하게 인지하기 위한 효과적 방법을 모색하기 위하여, 컴퓨터 모델링을 통하여 GRM 해석법의 특성을 분석하였다. 속도분석 함수가 수진점 사이 거리인 XY값에 따라 단층 부근에서 형태가 변하는 특성을 이용하여, XY값이 적정값보다 큰 경우와 작은 경우의 속도분석 함수값의 차이를 수평 1차 미분하여 구한 함수를 구하였으며 ''구배변화 지시자''로 명명하였다. 굴절면 경사가 작을수록, XY값의 차이가 클수록 구배변화 지시자의 최대치 진폭이 증가하고 진동거리가 짧아져 단층의 위치를 정확하게 지시하는 것으로 분석된다. 이러한 특성을 갖는 구배변화 지시자는 굴절법으로 얻어진 탄성파 자료를 이용하여 지표 근처의 고경사 단층 위치 및 분포 상태를 파악하는데 효과적으로 사용될 수 있을 것으로 기대된다.

  • PDF