Illuminating Characteristics of an Incandescent Lamp (전조용 백열등의 조도 특성)

  • 김태한;이경진;이정택
    • Journal of Biosystems Engineering
    • /
    • v.25 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • Motivated by the need for developing the more efficient lighting system for light culture in the greenhouses, this paper aims to predict the illumination of incandescent lamp according to various levels of lighting and various kinds of the lamp. The results obtained in this experiment are summarized as follows. 1. The general equation to predict the illumination according to the kind of incandescent lamp and the installation height was suggested as {{{{y= { a + bx+ cx^2} over { 1+dx+ex^2~ + fx^3} [lx]}}}} , where , a, b, c , d, e and of were arbitrary constants. 2. Maximum illumination of hat-covered lamp of 60 W was 1.2 -1.5 times as many as uncovered lamp. 3. Maximum illumination of yellow color painted lamp of 100 W was 1.3 times as many as unpainted lamp.

  • PDF

Detection of Salmonella typhi by Loop-mediated Isothermal Amplification Assay

  • Jo, Yoon-Kyung;Lee, Chang-Yeoul
    • Biomedical Science Letters
    • /
    • v.14 no.2
    • /
    • pp.115-118
    • /
    • 2008
  • Salmonella typhi is frequent causes of foodborne illness and its detection is important for monitoring disease progression. In this study, by using general PCR and novel LAMP (Loop Mediated Isothermal Amplification) assay, we evaluated the usefulness of LAMP assay for detection of Salmonella typhi. In this LAMP assay, forward inner primer (FIP) and back inner primer (BIP) was specially designed for recognizing target invA gene. Target DNA was amplified and visualized as ladder-like pattern of bands on agarose gel within 60 min under isothermal conditions at $65^{\circ}C$. When the sensitivity and reproducibility of LAMP were compared to general PCR, there was no difference of reproducibility but sensitivity of LAMP assay was more efficient than PCR (the detection limit of LAMP assay was 30 fg, while the PCR assay was 3 pg). These results indicate that the LAMP assay is a potential and valuable means for detection of Salmonella typhi, especially for its rapidity, simplicity and low cost.

  • PDF

Rapid and Efficient Detection of 16SrI Group Areca Palm Yellow Leaf Phytoplasma in China by Loop-Mediated Isothermal Amplification

  • Yu, Shao-shuai;Che, Hai-yan;Wang, Sheng-jie;Lin, Cai-li;Lin, Ming-xing;Song, Wei-wei;Tang, Qing-hua;Yan, Wei;Qin, Wei-quan
    • The Plant Pathology Journal
    • /
    • v.36 no.5
    • /
    • pp.459-467
    • /
    • 2020
  • Areca palm yellow leaf (AYL) disease caused by the 16SrI group phytoplasma is a serious threat to the development of the Areca palm industry in China. The 16S rRNA gene sequence was utilized to establish a rapid and efficient detection system efficient for the 16SrI-B subgroup AYL phytoplasma in China by loop-mediated isothermal amplification (LAMP). The results showed that two sets of LAMP detection primers, 16SrDNA-2 and 16SrDNA-3, were efficient for 16SrI-B subgroup AYL phytoplasma in China, with positive results appearing under reaction conditions of 64℃ for 40 min. The lowest detection limit for the two LAMP detection assays was the same at 200 ag/μl, namely approximately 53 copies/μl of the target fragments. Phytoplasma was detected in all AYL disease samples from Baoting, Tunchang, and Wanning counties in Hainan province using the two sets of LAMP primers 16SrDNA-2 and 16SrDNA-3, whereas no phytoplasma was detected in the negative control. The LAMP method established in this study with comparatively high sensitivity and stability, provides reliable results that could be visually detected, making it suitable for application and research in rapid diagnosis of AYL disease, detection of seedlings with the pathogen and breeding of disease-resistant Areca palm varieties.

Dependence of Round type electrodeless lamp according to Ferrite shape (페라이트 형상에 따른 둥근형 무전극 램프의 의존성)

  • Kim, Nam-Goon;Yang, Jong-Kyung;Lee, Joo-Ho;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.465-466
    • /
    • 2007
  • In electrode-less lamp, The key point in creating an efficient light source based on RF discharge is to minimize the RF power loss in the RF coupler which for Anderson's type of RF lamp is due to losses in the ferrite core. This loss depends on the particular ferrite material, its size, geometry, frequency in this kind of inductive lamp shows that the correct choice of discharge current has a crucial effect on the core loss. In this study, we measured Ferrite temperature in normal state, then analyzed electrical and optical characteristics according to ferrite shape. We were able to know that was ferrite of the antenna had relate closely with temperature and luminous of the lamp. Also we appraised temperature and electrical, optical properties during turn on the lamp.

  • PDF

A Study on the Plant Cultivation by comparing Ultra Constant Discharge (UCD) Lamp lighting and Hi-Pressure Sodium Lamp lighting (초정압방전램프(UCD)와 나트륨램프를 적용한 식물재배에 관한 연구)

  • JEONG, P.G.;KIM, Y.C.;YANG, H.S.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • This study was conducted to research how UCD(Ultra Constant Discharge) lamp lighting affects plant cultivation. To get the results within a short time, lettuce seedling was selected as a plant and nutrient hydroponic beds were used in a dark room for 100% artificial lighting. Two beds were installed for same distance lighting condition with UCD lamp and Hi-pressure Sodium lamp each and another two beds were installed for same light intensity condition with each type of lamp. After 15 days of cultivation, for both conditions, the yields under UCD lamp were weighed more than that under Hi-pressure Sodium lamp. The result can be analyzed that the spectrum of UCD lamp having near sunlight characteristic is much superior to that of Hi-pressure Sodium lamp having a line spectrum characteristic on yellow and red wavelengths for plant cultivation.

Dimming Control of Microcontroller-based Automotive HID Lamp Ballast (마이크로컨트롤러를 이용한 자동차용 고압방전등 안정기의 조광제어)

  • Lee Jae-Hak;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.1
    • /
    • pp.47-52
    • /
    • 2005
  • This paper presents dimming control system for automotive 35W metal halide discharge(MHD) lamp electronic ballast. HID lamp demands a highly efficient ballast and very complex control circuitry that can control complex transient state in applying to automotive. Therefore, in this paper, a microcontroller-based digital control method for the HID lamp ballast is presented for optimal control that can adapt complex transient state, steady state and various environments. In developed dimming system, the system is designed to control the lamp output voltage step by step(continuous) using microcontroller according to CdS sensor. Therefore the designed dimming control system give good driving condition to diver and realize the power control effectively. The results of the proposed system is verified through various experiment results.

Development of Light-Way Lighting Appliance of Specifications for Efficient Construction (효율적 시공을 위한 라이트웨이 조명등기구의 작업지시서 개발)

  • Choi, Chung-Seog;Koh, Jae-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.18-22
    • /
    • 2009
  • In this paper, we are develop specifications light-way lighting appliance for efficient construction. Analyzed wide application and connection regulation. Also, flickering circuit Presented separation, arrangement, mounting instruction. Incandescent lamp occurs much heat. Therefore, establishment of enough electric light interval is required. Voltage of discharge lamp does by below 300v, and provide so that a person is not can may touched.

  • PDF

Optical characteristics on driving method of ballast and shapes of Arc-Tube in the ceramic metal halide lamp (세라믹 메탈 할라이드 램프의 아크 튜브의 구조와 안정기 구동방법에 따른 광학적 특성)

  • Jang, Hyeok-Jin;Kim, Nam-Goon;Lee, Joo-Ho;Yang, Jong-Kyung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1495-1496
    • /
    • 2008
  • The Ceramic Metal Halide lamp is different from optical characteristic on shapes of arc-tube and driving method of ballast. In this paper, we measured optical characteristics of the Ceramic Metal Halide lamp that uses arc tubes which are spherical and cylindrical shapes, and analyzed the Ceramic Metal Halide lamp connecting ballast that is electronic and magnetic types through the lamp measurement system that is given for stabilization period of fifteen minutes. In result, the arc-tube of spherical shape is more improvement in the optical properties than the arc tube of cylindrical shape, moreover, the electronic ballast is more efficient than the optical properties of the magnetic ballast.

  • PDF

The Study Of Sequence Control for LED (LED 조명 발열의 순차 제어시스템 연구)

  • Choi, Hyeung-Sik;Yoon, Jong-Su;Shin, Hee-Young;Lim, Tae-Woo
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.99-100
    • /
    • 2011
  • In this paper, a temperature control for LED(Light Emitting Diode) lamp using a cooling fan is studied. An efficient temperature control scheme for the LED lamp using the fan wind at the lowest sound noise is studied. Also, for minimization study of sound noise and temperature control of an LED lamp, a sequential control algorithm using the cooling fan at the lowest sound noise is presented. For the study, after measurement of the minimum sound noise of the fan and related temperature of the LED lamp through tests, experiments on temperature control of the LED lamp using the fan was performed.

  • PDF

A Single-Stage LED Tube Lamp Driver with Input-Current Shaping for Energy-Efficient Indoor Lighting Applications

  • Cheng, Chun-An;Chang, Chien-Hsuan;Cheng, Hung-Liang;Chung, Tsung-Yuan;Tseng, Ching-Hsien;Tseng, Kuo-Ching
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1288-1297
    • /
    • 2016
  • This study proposes a single-stage light-emitting diode (LED) tube lamp driver with input-current shaping for T8/T10-type fluorescent lamp replacements. The proposed AC-DC LED driver integrates a dual-boost converter with coupled inductors and a half-bridge series-resonant converter with a bridge rectifier into a single-stage power conversion topology. This paper presents the operational principles and design considerations for one T8-type 18 W-rated LED tube lamp with line input voltages ranging from 100 V rms to 120 V rms. Experimental results for the prototype driver show that the highest power factor (PF = 0.988), lowest input current total harmonic distortion (THD = 7.22%), and highest circuit efficiency (η = 92.42%) are obtained at an input voltage of 120 V. Hence, the proposed driver is feasible for use in energy-efficient indoor lighting applications.