• 제목/요약/키워드: Efficiency temperature coefficient

검색결과 274건 처리시간 0.03초

대형 LPG 엔진 피스톤의 온도 분포 해석을 위한 열전도 역문제에 관한 연구 (Research on the Inverse Heat Conduction Problem for Thermal Analysis of a Large LPG Engine Piston)

  • 이부윤;박철우;최경호
    • 한국정밀공학회지
    • /
    • 제19권11호
    • /
    • pp.146-159
    • /
    • 2002
  • An efficient method to predict the convection heat transfer coefficients on the top surface of the engine piston is proposed. The method is based on the inverse method of the thermal conduction problem and uses a numerical optimization technique. In the method, the heat transfer coefficients are numerically obtained so that the difference between analyzed temperatures from the finite element method and measured temperatures is minimized. The method can be effectively used to analyze the temperature distribution of engine pistons in case when application of prescribed-temperature boundary condition is not reasonable because of insufficient number of measured temperatures. A hollow sphere problem with an analytic solution is taken as a simple example and accuracy and efficiency is demonstrated. The method is applied to a practical large liquid petroleum gas(LPG) engine piston and the heat transfer coefficients on the top surface of the piston is successfully calculated. Resulting analyzed temperature favorably coincides with measured temperature.

고온 생산용 열펌프 사이클 설계 (Study on Design Technology of Heat Pump Cycle for High Temperature Performance)

  • 김종률;김석영;김용민;이공훈;김욱중;이성철;정치영;김종열
    • 에너지공학
    • /
    • 제19권4호
    • /
    • pp.228-233
    • /
    • 2010
  • 기존의 열풍건조기의 효율은 약 30% ~ 50%인 반면, 최적 설계된 열풍-열펌프 건조기 효율은 약 60% ~ 80% 수준이므로 에너지 효율향상과 에너지 절약을 이룰 수 있다. 외국의 여러 사례에서는 기존 대비 약 60% ~ 80%의 에너지를 절약할 수 있으며, 밀폐형 순환방법을 사용하여 건조공기에 포함될 수 있는 환경오염물질의 외부로의 유출을 최소화 할 수 있어 기존의 건조기에 비해서 환경문제에 적극적으로 대응할 수 있을 것을 판단된다. 본 논문에서는 이와 같은 특성을 가진 건조기에 적용하기 위한 고온 생산이 가능한 열펌프를 얻기 위하여 시스템의 사이클을 설계하고 시스템을 구축하여 목표 성능을 만족하는지 여부를 확인하였다. 본 연구에서는 열펌프 복합건조기 적용을 위한 고온용 열펌프 시스템을 설계하고 제작한 후, 성능평가를 수행하여 다음의 결론을 얻었다. (1) 고온생산을 위한 시스템 설계는 2사이클이 가장 우수한 것으로 나타났다. (2) 2사이클 시스템은 저단이 R134a를, 고단이 R124를 냉매로 사용할 경우 가장 적합한 것으로 나타났다. (3) 사이클 운전을 통하여 상용압력으로 간주되는 범위에서 R134a시스템은 $75^{\circ}C$, R124시스템은 $95^{\circ}C$ 생산이 가능한 것으로 나타났다. (4) 수냉식 2사이클 시스템의 성능 시험을 수행한 결과 목표성능을 상회하는 결과를 얻어 고온 생산이 가능한 열펌프 시스템의 설계 및 제작이 가능한 것으로 나타났다.

Raman Lidar for the Measurement of Temperature, Water Vapor, and Aerosol in Beijing in the Winter of 2014

  • Tan, Min;Shang, Zhen;Xie, Chenbo;Ma, Hui;Deng, Qian;Tian, Xiaomin;Zhuang, Peng;Zhang, Zhanye;Wang, Yingjian
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.15-22
    • /
    • 2018
  • To measure atmospheric temperature, water vapor, and aerosol simultaneously, an efficient multi-function Raman lidar using an ultraviolet-wavelength laser has been developed. A high-performance spectroscopic box that utilizes multicavity interference filters, mounted sequentially at small angles of incidence, is used to separate the lidar return signals at different wavelengths, and to extract the signals with high efficiency. The external experiments are carried out for simultaneous detection of atmospheric temperature, water vapor, and aerosol extinction coefficient in Beijing, under clear and hazy weather conditions. The vertical profiles of temperature, water vapor, and aerosol extinction coefficient are analyzed. The results show that for an integration time of 5 min and laser energy of 200 mJ, the mean deviation between measurements obtained by lidar and radiosonde is small, and the overall trend is similar. The statistical temperature error for nighttime is below 1 K up to a height of 6.2 km under clear weather conditions, and up to a height of 2.5 km under slightly hazy weather conditions, with 5 min of observation time. An effective range for simultaneous detection of temperature and water vapor of up to 10 km is achieved. The temperature-inversion layer is found in the low troposphere. Continuous observations verify the reliability of Raman lidar to achieve real-time measurement of atmospheric parameters in the troposphere.

Use of Capparis decidua Extract as a Green Inhibitor for Pure Aluminum Corrosion in Acidic Media

  • Al-Bataineh, Nezar;Al-Qudah, Mahmoud A.;Abu-Orabi, Sultan;Bataineh, Tareq;Hamaideh, Rasha S.;Al-Momani, Idrees F.;Hijazi, Ahmed K.
    • Corrosion Science and Technology
    • /
    • 제21권1호
    • /
    • pp.9-20
    • /
    • 2022
  • The aim of this paper is to study corrosion inhibition of Aluminum with Capparis decidua extract. The study was performed in a 1.0 M solution of hydrochloric acid (HCl) and was monitored both by measuring mass loss and by using electrochemical and polarization methods. A scanning electron microscopy (SEM) technique was also applied for surface morphology analysis. The results revealed high inhibition efficiency of Capparis decidua extract. Our data also determined that efficiency is governed by temperature and concentration of extract. Optimum (88.2%) inhibitor efficiency was found with maximum extract concentration at 45 o C. The results also showed a slight diminution of aluminum dissolution when the temperature is low. Based on the Langmuir adsorption model, Capparis decidua adsorption on the aluminum surface shows a high regression coefficient value. From the results, the activation enthalpy (∆H#) and activation entropy (∆S#) were estimated and discussed. In conclusion, the study clearly shows that Capparis decidua extract acted against aluminum corrosion in acidic media by forming a protective film on top of the aluminum surface.

농업용수 활용을 위한 비피압지하수관정 수온의 시계열 변동특성 (Time Series Change Characteristics of Unconfined Groundwater Wells Temperatures for Agricultural Water Use)

  • 박승기;정남수
    • 농촌계획
    • /
    • 제22권1호
    • /
    • pp.13-23
    • /
    • 2016
  • There is a need to analyze unconfined groundwater behavior since the demand of groundwater use has been increasing. While unconfined groundwater temperature is tend to be affected by air temperature, it is hard to find an empirical study in South Korea. In this research, we try to determine the relationship between daily average air temperature and daily average groundwater temperature by time-sequential analysis of groundwater monitoring wells in Galshin basin in Yesan-Gun, Chungcheongnam-Do. In addition, models to estimate groundwater temperature from air temperature were developed. In this research 101-day moving average method with measured air temperature is used to estimate groundwater temperature. To verify the developed model, estimated values of average groundwater temperature with 101 moving average are compared to the measured data from September 10 2007 to September 9 2008. And, Nash-Stucliff Efficiency and Coefficient of Determination were 0.970 and 0.976, therefore it was concluded that the model allowing groundwater temperature estimation from air temperature is with reasonable applicability.

파이롯트 규모의 BNR 공법에 의한 도시하수의 질소 및 인 제거 (Removal of Nitrogen and Phosphorus from Municipal Wastewater by a Pilot-scale BNR Process)

  • 김영철
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.589-599
    • /
    • 2007
  • This study was conducted to investigated the removal efficiency of BOD and nutrient for the treatment of low strength municipal wastewater by a biological nutrient removal system. In this experiment, the effect of operating parameter including HRT of 7.0hr, BOD/TN ratios of 2.62~4.08, internal recycle of 50~300%, and return sludge of 50~100%, were studied during winter season. Efficiencies of organic matter and T-P removal and denitrification were not significantly affected by the change of temperature in winter season. However, the specific nitrification rate and nitrification efficiency decreased at low temperature. Besides, denitrification efficiencies increased with increasing BOD/TN ratios. It was also found that the internal recycle and return sludge ratio below 50% is required for the effective denitrification of low strength municipal wastewater. With operating mode 4 of the optimum, the effluent BOD, T-N and T-P concentration were obtained to average 5.8, 14.6, and 0.84 mg/L, respectively. The temperature-activity coefficient (${\theta}$) of specific nitrification rate, specific denitrification rate and specific phosphorus uptake rate were obtained 1.044, 1.017, 1.028, respectively.

Response surface analysis of removal of a textile dye by a Turkish coal powder

  • Khataee, Alireza;Alidokht, Leila;Hassani, Aydin;Karaca, Semra
    • Advances in environmental research
    • /
    • 제2권4호
    • /
    • pp.291-308
    • /
    • 2013
  • In the present study, an experimental design methodology was used to optimize the adsorptive removal of Basic Yellow 13 (BY13) using Turkish coal powder. A central composite design (CCD) consisting of 31 experiments was employed to evaluate the simple and combined effects of the four independent variables, initial dye concentration (mg/L), adsorbent dosage (g/L), temperature ($^{\circ}C$) and contact time (min) on the color removal (CR) efficiency (%) and optimizing the process response. Analysis of variance (ANOVA) showed a high coefficient of determination value ($R^2=0.947$) and satisfactory prediction of the polynomial regression model was derived. Results indicated that the CR efficiency was not significantly affected by temperature in the range of $12-60^{\circ}C$. While all other variables significantly influenced response. The highest CR (95.14%), estimated by multivariate experimental design, was found at the optimal experimental conditions of initial dye concentration 30 mg/L, adsorbent dosage 1.5 g/L, temperature $25^{\circ}C$ and contact time 10 min.

다중 물 분사 노즐이 장착된 감온밸브의 해석 연구 (An Analysis Study on Desuperheater valve attachment on Multi Water Spray Nozzles)

  • 이덕구;조행훈;조남철;이채문
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.74-79
    • /
    • 2009
  • The generation of electric power and plant facilities have been attempting to improve energy efficiency with many efforts as those being basis of our country's economy. In particular, the CHP(Combined Heat Power plant) system, is producing the electricity and process steam, has generally been using for the cogeneration plants. When CHP system operates, the steam has to maintain the high temperature and high pressure in order to have high efficiency of electric power production as much as possible. In addition, the exhausted steam from the turbine has to reform proper temperature to use the needed process. The major purpose of desuperheater is that the superheated steam changes into the saturated steam because it is more efficient and suitable for using the process, furthermore, it is more convenient and stable regarding the process temperature control. The design of the desuperheater obtained through the experiment and preceding analysis. This paper is verified by analysis that water spray nozzle(${\Phi}$=28mm) shows the best ability under the real power plant condition.

  • PDF

Homogeneous 에미터와 Selective 에미터 결정질 실리콘 태양전지의 온도에 따른 전류-전압 특성 변화 측정 및 분석 (Measurement and Analysis of Temperature Dependence for Current-Voltage Characteristics of Homogeneous Emitter and Selective Emitter Crystalline Silicon Solar Cells)

  • 남윤정;박효민;이지은;김수민;김영도;박성은;강윤묵;이해석;김동환
    • 한국재료학회지
    • /
    • 제24권7호
    • /
    • pp.375-380
    • /
    • 2014
  • Solar cells exhibit different power outputs in different climates. In this study, the temperature dependence of open-circuit voltage(V-oc), short-circuit current(I-sc), fill factor(FF) and the efficiency of screen-printed single-crystal silicon solar cells were studied. One group was fabricated with homogeneously-doped emitters and another group was fabricated with selectively-doped emitters. While varying the temperature (25, 40, 60 and $80^{\circ}C$), the current-voltage characteristics of the cells were measured and the leakage currents extracted from the current-voltage curve. As the temperature increased, both the homogeneously-doped and selectively-doped emitters showed a slight increase in I-sc and a rapid degradation of V-oc. The FF and efficiency also decreased as temperature increased in both groups. The temperature coefficient for each factor was calculated. From the current-voltage curve, we found that the main cause of V-oc degradation was an increase in the intrinsic carrier concentration. The temperature coefficients of the two groups were compared, leading to the idea that structural effects could also affect the temperature dependence of current-voltage characteristics.

실험실 수준의 반응조 온도가 양돈폐수중 질소, 인의 처리에 미치는 영향 (Effect of Temperature on Treatment of Nitrogen and Phosphorus of Pig Wastewater in Bench Scale Reactor)

  • 박석환
    • 한국환경보건학회지
    • /
    • 제21권1호
    • /
    • pp.86-92
    • /
    • 1995
  • This study was performed to evaluate the effect of temperature on operating parameters for reactor in pig wastewater treatment using sequencing batch reactor method which is one of the biological treatment methods. Study was accomplished by experimental apparatus of bench scale, and the degradation rate coefficient and temperature correction factor were derived. The followings are the conclusions that were derived from this study. 1. In the characteristics of pig wastewater, concentrations of TKN and T-P were very high as 590 mg/l and 40 mg/l, respectively. 2. Removal efficiency of BOD and $COD_{Mn}$ as organic compound indicators were the highest mark as 97% at 25$\circ$C. 3. When temperature was incresed from 10$\circ$C to 25$\circ$C, removal efficiencies of TKN and T-P were proportionally increased. Especially, the former was greatly effected by temperature of reactor. 4. In experiment of bench scale, the degradation rate coefficients were increased as temperature increased, but decreased at the temperature range of 25~35$\circ$C. Temperature adjustment coefficients for $COD_{Mn}$, BOD, TKN and T-P were 1.1460, 1.1356, 1.1140 and 1.0565, respectively.

  • PDF