• Title/Summary/Keyword: Efficiency Standards

Search Result 995, Processing Time 0.029 seconds

Characteristics of Magnetostrictive Sensor for Detecting the Flaws in Pipe (배관결함 검출을 위한 자왜형 초음파 센서의 특성)

  • Ahn, Bong-Young;Kim, Young-Joo;Kim, Young-Gil;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.46-53
    • /
    • 2000
  • Magnetostrictive sensors which can be used effectively to detect flaws in pipe were fabricated. The optimal conditions to obtain the maximum generation efficiency of the ultrasonic wave were established. In case of the used steel pipe the optimal magnetic field was $250{\sim}350Oe$ and the coil width of 15mm showed the best efficiency for generating a wave with the frequency of 180 kHz. In the best condition, the wave can propagate further than 50m without serious attenuation. The amplitude of the ultrasonic wave reflected from artificial flaw had a good linear relationship to the cross-sectional area of the flaw.

  • PDF

A Study on the Target Values Fixing of Green Vehicle Emissions in Consideration of In-use Deterioration (운행차 열화특성을 고려한 제작차 배출가스 목표치 설정에 관한 연구)

  • 김현우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.104-110
    • /
    • 2003
  • As exhaust emission standards are more stringent, higher conversion efficiency of automotive catalytic converter is required. In addition, catalytic converter is deteriorated during mileage accumulation of vehicle. Therefore the specification of catalytic converter should be decided in consideration of emission standards and deterioration. Because the decision of the specification of catalytic converter is required at the beginning of vehicle development procedure, it is important and necessary to fix the target values of green vehicle exhaust emissions. To do this, a linear regression analysis was done with in-use exhaust emissions data of 5 different kinds of vehicle that received US94 emission standards certification, and data handling methods including some statistical estimation were proposed. As a result, the fixed target values of NMHC, CO, NOx of green vehicle against US94 emission standards were 0.079, 0.83, 0.116, respectively. And expected in-use deterioration factor of NMHC, CO, NOx were 1.75, 2.02, 1.38, respectively. And also it was blown that even if failure rate is 30% after 80,000km driven, it might be sufficiently safe from emission failure confirmatory test of Korea. It is hopeful to make a database of in-use emissions to increase the confidence in correctness of the calculated target values.

A Study on the Improvement of Defense Standardization Information Management (국방표준화 정보관리 개선방안 연구)

  • Jang, Pil-Hoon;Choi, Seok-Cheol
    • Journal of the military operations research society of Korea
    • /
    • v.34 no.1
    • /
    • pp.13-30
    • /
    • 2008
  • In this study, the establishment strategies of Military Standardization Information System and Integrated Database(DB) based on standardization information are provided. The establishment strategies introduced here are based on the appliable common(commercial and military) classification of specifications/standards. The common(commercial and military) classification of specifications/standards adapted in this study can be constructed through mapping by 'grouping' between the MS(Military Specification/Standards) and KS(Korean industry Standards) to increase efficiency. In detail, the establishment of Integrated Database(DB) based on standardization information provides the various channel of interactive communication among specifications/standards. Additionally, standardization information systems provide the basis of the integrated specifications/standards converged between the commercial and military sector.

An Analysis on the Improvement Plan of energy efficiency standard for household refrigerator and air conditioner (냉장고와 에어컨의 에너지 효율 기준 개선 방안 분석)

  • Oh, Min-Hyuk;Baek, Jung-Myoung;Lee, Byung-Ha;Kim, Jung-Hoon;Hwang, Sung-Wook;Won, Jong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.216-218
    • /
    • 2006
  • Economy of world has grown rapidly. This growth has increased the ownership of household electrical appliances including room air conditioners. The number of users of air conditioners is predicted to grow dramatically in the future. This paper discusses the present status of residential appliance energy efficiency standards around the world. The study found that the energy efficiency standards for room all conditioners would mitigate a significant amount of emissions in Korea.

  • PDF

A Study on High Efficiency Certification Standards of Metal-Halide Lamps and Reflectors using HID Lamps (메탈할라이드 램프 및 HID용 고조도 반사갓의 고효율에너지기자재 인증기술기준 연구)

  • Jeong, Hak-Geun;Lee, Sun-Keun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.160-162
    • /
    • 2004
  • The aim of this study is to make the technical standards for certificating a high efficiency metal-halide lamps and reflectors using the high intensity discharge lamps, to accomplish the practical energy saving effect. Metal-halide lamps are certificated by stabilzed and restarting time, lamp voltage, current, power and light output efficiency. The high illumination reflectors using HID lamps are certificated by testing reflective index, fading, the melting point, glare and install spacing factor.

  • PDF

A Study on Establishing Infrastructure Plans to Introduce an Energy Efficiency Resource Standards - Based on the Energy Demand Side Management and Energy Efficiency Potential - (에너지효율향상의무화제도의 국내 도입을 위한 기반구축 연구 - 에너지수요관리제도 및 절감률 산정 중심으로 -)

  • Hong, Sung-Jun;Choi, Bong-Ha;Lee, Deok-Ki;Park, Soo-Uk;Won, Jong-Ryul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.3
    • /
    • pp.241-247
    • /
    • 2010
  • An Energy Efficiency Resource Standards (EERS) is a simple, market-based mechanism to encourage more efficient generation, transmission, and use of electricity, natural gas and heat. An EERS consists of electric, gas and/or heating energy savings targets for utilities, often with flexibility to achieve the target through a market-based trading system. In this paper, we make persons acquainted with EERS programs of foreign countries in these days. And we analyze domestic energy demand side management (DSM) programs in order to introduce an EERS program into the country successfully. Energy efficiency potential calculated in 2007 is one of the important factors for establishing an EERS program domestically. This study may provide basic data to set the amount of energy saving when an EERS program would be phased in.

A Study on the Measurement of the Winding Resistance Influences the Efficiency Evaluation of 3phase Induction Motors (삼상유도전동기 권선저항 측정이 효율 산출에 미치는 영향에 관한 연구)

  • Kang, Byung-Guk;Kim, Kwang-Min;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.73-78
    • /
    • 2016
  • 3phase induction motor consumes 40% of national electric power. so It is one of the most important electric device for the national power policy. The efficiency measurement is carried out by IEC standards. After the temperature rise test, It's difficult to measure the winding resistance immediately. because of inertia and power cut-off time. Therefore, IEC standards suggest the measurement time. But during the measurement time, the winding temperature cools down. It causes the value of winding resistance is variable. Several conditions which possibly occurred by the measurement time of IEC 60034-1 are suggested. and The efficiency evaluation of 3phase induction motors is carried out by IEC 60034-2-1 with the several conditions. As the results, we find out the winding resistance rapidly goes down within 15 sec. so It proves that the winding resistance should be measured within 15 sec. for the efficiency evaluating of 3phase induction motor.

A Study on Collection Efficiency And Economy of Total Hydrocarbons in Accordance with Time Changes at Activated Carbon Collection Facility (활성탄집진시설의 시간변화에 따른 총탄화수소의 집진효율성 및 경제성에 관한 연구)

  • Kim, Seong Jung;Han, Dae Hee;Woo, In Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.231-236
    • /
    • 2014
  • In this study, the changes in collection efficiencies due to the time changes of activated carbons were ascertained, and in order to identify the magnitude of adsorption, the before-use and after-use iodine adsorption values were analyzed. In addition, as a result of examining the characteristics of continuous process and non-continuous process and as a result of investigating whether the emission standards would be maintained, the continuous process and printing facilities were seen as not being able to maintain the emission standards. Also were found, in the case of non-continuous process,-taking into consideration the special nature of the job -for 4${\o}$ palletized charcoal, a collection efficiency near 50% was shown even after 96 hours. Also, when the inlet concentration was about 300ppm, it is thought that the emission standards would be maintained if the activated carbons are replaced within at least 96 hours in the case of 4${\o}$ palletized charcoal and the use was deemed pointless in the case of carbon. The results of this study are expected to provide assistance in selecting replacement periods for activated carbons and in selecting absorbents at the project sites, and are expected to be of significant help in the selection of precipitators that can collect total hydrocarbons for compliance of the emission standards.

A Chronological Study on the Transformation and the Spatial Characteristics of Inpatient Care Facilities in the United States (미국의료시설 병동부의 시대적 변천과 공간적 특성에 관한 연구)

  • Lee, Sukyung;Choi, Yoonkyung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.3
    • /
    • pp.57-69
    • /
    • 2017
  • Purpose: This study aims to emphasize interrelation between healthcare policies, design standards and hospital architecture of the United States since 1950s; to examine spatial characteristics of inpatient care facilities through case studies; and to consider the social implication of these spatial changes. Methods: In this study, reviewing the overall healthcare system, design standards and inpatient care facilities of the United States since 1950s, a total of five inpatient care facilities, one for each period, were selected in order to analyze the spatial characteristics. The spatial maps of Space Syntax were employed for analyzing five case studies. Results: The distance between the nursing station, the support service, and inpatient room were getting closer. The spatial structure of inpatient care facilities is transformed from tree structures to annular tree structures. This result shows that the efficiency between patient, staff and support service is higher and the depth of the spaces is getting deeper, which indicates that efficiency for improving healthcare quality affect the spatial structure of inpatient care facilities. Implications: In the future, if Korea's health policy is changed to a demand-oriented health care policy, this conclusion predicts medical planning of hospital will be focused on the efficiency.