• Title/Summary/Keyword: Efficiencies

Search Result 3,644, Processing Time 0.03 seconds

Evaluation Efficiency of University libraries though Data Envelopment Analysis (DEA를 이용한 대학도서관의 효율성 평가 -프랑스의 대학도서관을 대상으로-)

  • Kim, Sun-Ae
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.38 no.2
    • /
    • pp.137-160
    • /
    • 2004
  • In order to appreciate the varied activities of university libraries, this study assesses their efficiencies in the process of production and utilization of their services for two consecutive years, 1999 and 2000. Using a Data Envelopment Analysis with exogenously fixed factors, this study analyses separately efficiencies identified. The results show that efficiencies of libraries appear differently according to the year of evaluation, the dimension of evaluation as well as the difference of statute. The specialized libraries as CADIST are definitely higher in terms of use of services. In addition, inefficiency is mainly due to deficits of production of outputs rather than excesses of utilisation of inputs. For example, time devoted to user's training constitutes the most significant potentiality of increase in the production of services.

Effects of Co-current and Cross Flows on Circular Enhanced Gravity Plate Separator Efficiencies

  • Ngu, Lock Hei;Law, Puong Ling;Wong, Kien Kuok
    • Environmental Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.151-155
    • /
    • 2014
  • This study compares the effects of flow on oil and suspended solids removal efficiencies in circular enhanced gravity plate separator equipped with coalescence medium. Coalescence medium acts to capture rising oil droplets and settling solid particles and assist in the coalescence of oil and coagulation of solid. The circular separator uses an upflow center-feed perforated-pipe distributor as the inlet. The co-current flow is achieved using 4 increasing sizes of frustum, whereas cross flow uses inclined coalescence plates running along the radius of the separator. The different arrangement gave the cross flow separator a higher coalescence plan area per operational volume, minimal and constant travelling distance for the oil droplets and particles, lower retention time, and higher operational flowrate. The cross flow separator exhibited 6.04% and 13.16% higher oil and total suspended solids removal efficiencies as compared to co-current flow.

Assessment of Irrigation Efficiencies using Smarter Water Management (농촌수자원 스마트 물관리를 활용한 농업용수의 관개효율 평가)

  • Nam, Won Ho;Choi, Jin Yong;Hong, Eun Mi;Kim, Jin Taek
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.4
    • /
    • pp.45-53
    • /
    • 2013
  • Efficient water operation and management of an irrigation system plays an important element in the sustainability of irrigated agriculture. An agricultural water is delivered in many open canals of irrigation delivery system by reservoirs. The poor water distribution and management in an irrigation system is a major factor leading to low water efficiency. It is necessary to compare the estimated irrigation demands with the actual water supplies for decision making to maintain the water supply according to demand strategy. Smarter water management, new technologies and improvement of water management system, is essential to solve the problem of water efficiency and availability. In this paper, the irrigation efficiencies according to water delivery performance indicator were measured with automatic water gauge at irrigation canals, and calculated from spatial and temporal distribution of water supply for the lack of planning in water delivery. The analysis of results are obtain an insight into possible improvement methods to develop canal water management policies that enable irrigation planners to optimally manage scarce available water resources.

Vertical axis wind turbine types, efficiencies, and structural stability - A Review

  • Rehman, Shafiqur;Rafique, Muhammad M.;Alam, Md. Mahbub;Alhems, Luai M.
    • Wind and Structures
    • /
    • v.29 no.1
    • /
    • pp.15-32
    • /
    • 2019
  • Much advancement has been made in wind power due to modern technological developments. The wind energy technology is the world's fastest-growing energy option. More power can be generated from wind energy by the use of new design and techniques of wind energy machines. The geographical areas with suitable wind speed are more favorable and preferred for wind power deployment over other sources of energy generation. Today's wind turbines are mainly the horizontal axis wind turbines (HAWTs) and vertical axis wind turbines (VAWTs). HAWTs are commercially available in various sizes starting from a few kilowatts to multi-megawatts and are suitable for almost all applications, including both onshore and offshore deployment. On the other hand, VAWTs finds their places in small and residential wind applications. The objective of the present work is to review the technological development, available sizes, efficiencies, structural types, and structural stability of VAWTs. Structural stability and efficiencies of the VAWTS are found to be dependent on the structural shape and size.

Measuring the efficiency and determinants of rice production in Myanmar: a translog stochastic frontier approach

  • Wai, Khine Zar;Hong, Seungjee
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.1
    • /
    • pp.59-71
    • /
    • 2021
  • This study investigated the extent to which rice producers from the Ayeyarwaddy Region of Myanmar could improve their productivity if inputs were used efficiently in rice cultivation. To achieve this objective, simple random sampling was used to collect data from 300 rice growers in the study area. Data were analyzed with the translog stochastic frontier approach to understand the production efficiencies. The study further estimated the influencing factors that affect the efficiency levels of rice farmers. The empirical result reveals that the average technical, allocative, and economic efficiencies were at 76.11, 47.85, and 34.15%, respectively. This suggests that there is considerable room for improving rice production by better utilization of the available resources at the current level of technology. This study suggests that strenthening agricultural training programs and adoption of improved rice varieties may reduce overall inefficiencies among rice farmers in Myanmar. Factors like age, household size, education, farming experience, farm size, rice variety, training, and off-farm income have a significant impact on increasing/decreasing farmer's efficiency. Efficiency can be improved by establishing farmer field school programs to increase the scale of operations. The government should encourage young educated people to participate in paddy production and also intervene to reduce input prices and control the quality of seeds.

Evaluation of promising oyster mushrooms (Pleurotus spp.) for production in tropical regions

  • Javier Alejandro Trujillo, Rugamas;Kyong Jin, Min;Hye Sung, Park;Tai Moon, Ha;Eun Ji, Lee
    • Journal of Mushroom
    • /
    • v.20 no.4
    • /
    • pp.193-198
    • /
    • 2022
  • The biological efficiencies of promising Pleurotus spp. were evaluated. Pleurotus ostreatus, Pleurotus tuberregium,and Pleurotus sajor-cajuwere investigated at temperatures of 22℃, 20℃, and 18℃ to determine their ability to adapt to temperatures that are likely to be found in subtropical regions. The experiment was conducted using a substrate comprising Popular sawdust 60% + cotton seed 20% + beet pulp 20% under a relative humidity of 65%. The results indicated that there were significant differences in terms of biological efficiency between the species: P. tuber regium 128.84% at 22℃, P. ostreatus 108.41% at 22℃, and P. sajor-caju is 80% at 20℃. The common temperatures at which all species showed the highest biological efficiencies were 22℃ and 20℃. Therefore, the production of the evaluated species was equal to or surpassed biological efficiencies reported in tropical environments, thereby demonstrating a potential opportunity to adapt to tropical environments without compromising quality standards.

Comparison of Exhaust Gas Recirculation and Excess Air Strategies for Improving Thermal Efficiency and Reducing Nitrogen Oxides emissions in Hydrogen Spark-ignition Engines at Low-load Operation (수소 스파크점화 엔진의 저부하 운전에서 열효율 및 질소산화물 배출 개선을 위한 배기가스재순환과 과잉공기 전략 비교)

  • Hyunwook Park;Junsun Lee;Seungmook Oh;Yonggyu Lee;Changup Kim
    • Journal of ILASS-Korea
    • /
    • v.29 no.2
    • /
    • pp.60-67
    • /
    • 2024
  • This study compared exhaust gas recirculation (EGR) and excess air strategies for improving thermal efficiency and emissions of hydrogen combustion engines at low-load operation. The experimental investigation was conducted in a single-cylinder, heavy-duty engine under throttling and wide-open throttle (WOT) conditions. Although both EGR and excess air strategies reduced peak heat release rates and increased combustion durations, the net indicated thermal efficiencies were improved by reducing the pumping losses. Under the constraint of similar nitrogen oxides emissions, the EGR strategy had higher net indicated thermal efficiencies compared to the excess air strategy in throttling operation. However, the difference between their thermal efficiencies was reduced under WOT condition. The trend of reducing nitrogen oxides emissions according to the two strategies was similar.

Sewage Treatment using Membrane Bioreactor(MBR) and Reverse Osmosis(RO) Process (Membrane bioreactor(MBR)과 Reverse osmosis(RO) 공정을 이용한 하수처리)

  • Oh, Seungwook;Jung, Jongtae;Lee, Jinwoo;Kim, Jongoh
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.6
    • /
    • pp.21-28
    • /
    • 2007
  • The objective of this study was to investigate the effect of hydraulic retention time (HRT) on removal efficiencies of organic matter, nitrogen and phosphorus in MBR-RO process for treating synthetic sewage. In MBR process, turbidity was less than average 2 NTU and average removal efficiency showed more than 99% during the operation period(MBR 105 day). As a result of HRT variation, average removal efficiencies of $COD_{Cr}$ on HRT 6, 12, 18 and 24hour were about 72.4, 84, 88.6 and 92.5%, respectively. The $NH_4{^+}-N$ removal efficiency was about 60.2 85.5, 91.3 and 92.2%, respectively. T-N and T-P removal efficiencies increased from 53.7 and 56.8 to 82.5 and 86.4%, respectively as the HRT increased from 6 hour to 24 hour. In RO process, average removal efficiencies of color and $COD_{Cr}$ in RO permeate were about 99.9% and 96.8%, respectively. Also, removal efficiencies of T-N, $NH_4{^+}-N$, $NO_3{^-}-N$ and T-P were all above average 90%.

  • PDF

Effects of temperature and relative humidity on the sampling efficiencies of mixed organic vapors measured by diffusion monitors (확산 포집기로 공기중 혼합유기용제 포집시 온도와 상대습도가 포집효율에 미치는 영향)

  • Han, Jin gu;Roh, Young Man;Kim, Hyun Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.200-211
    • /
    • 1995
  • This study was designed to evaluate the effects of temperature and humidity on the sampling efficiency of mixed organic vapors of l,2-DCE, benzene, and MIBK by 3 different types of diffusion monitors. Independent variables used for the study were temperatures ($25^{\circ}C$, $35^{\circ}C$), humidities (30%, 80%), and vapor concentrations (low, medium, and high). In addition, vapor concentrations measured by the traditional charcoal tube method were used as reference values and were compared with those of by diffusion monitors. The results were as follows: 1. The desorption efficiencies(DE) of 1,2-DCE and benzene from charcoal tubes and from diffusion monitors ranged from 98% to 105%. In contrast, the DEs of MIBK from charcoal tubes and diffusion monitors except DM1 ranged from 71% to 85%. The DE of MIBK from DM1 was 98%. 2. No statistically significant differences of 1,2-DCE concentrations and the sampling efficiencies regardless of temperatures and humidities studied between charcoal tube and 3 diffusion monitors were found. 3. At 80% humidity, increasing frequencies of 1,2-DCE breakthrough at higher temperature and higher vapor concentration measured by charcoal tubes were observed. 4. No statistically significant difference of benzene concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly lower at all experimental conditions except the $35^{\circ}C$ and 30% humidity condition. 5. No statistically significant difference of MIBK concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly higher at higher humidity conditions regardless of temperature. Although statistically not significant, sampling efficiency of MIBK showed positive correlation with humidity while negative correlation with concentration was observed. 6. For sampling 1,2-DCE and benzene, no significant variations of concentrations among three diffusion monitors regardless of temperature and humidity conditions were found. For MIBK sampling, however, wide variations with increasing humidity among diffusion monitors were obtained. In conclusion, this study suggests that diffusion monitors will be a reasonables substitute for the traditional charcoal tubes for sampling non-polar organic vapors at temperature and humidity conditions studied. For polar organic vapors, use of an alternative desorption solution other than CS2 is recommended because of its low desorption efficiency. In addition, since variable among diffusion monitors for polar organic vapors particularly at higher humidity conditions were observed, further study is recommended of the effects of humidity on the performance of diffusion monitors.

  • PDF

Evaluation of Removal Efficiencies of Micropollutants in Wastewater Treatment Plants (산업폐수처리장에서의 미량유해물질 제거율 평가)

  • Lee, In-Seok;Sim, Won-Jin;Oh, Jeong-Eun;Kim, Chang-Won;Chang, Yoon-Seok;Yoon, Young-Sam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.2
    • /
    • pp.214-219
    • /
    • 2007
  • 66 micropollutants analyses in 9 wastewater treatment plants(WWTPs) along Nak-dong river were implemented to identify the concentrations and removal efficiencies before and after treatment processes. As a result of study, the concentration levels discharged from WWTP effluents to water system were below the water quality criteria and the levels of other studies. The removal efficiencies were 84.6%(DAF/CCR) and 81.6%(AC) for 1,4-dioxane. Phenol, Clphs and PAHs were removed 94.6%, 66.4% and 80.6% respectively by the activated sludge(AS) process. The removal efficiencies of Clbzs were 45.3% for the activated sludge(AS) process and 60.6% for the activated carbon(AC) process. However, other processes besides AS and AC, the removal efficiencies of Clbzs were very low(<20%). The sand filtration(SF) process that could remove particle matters showed the best efficiency for PCDDs / Fs removal$(\geq99%)$. However, in case of relatively low PCDDs/Fs concentration level in influent, the removal efficiency was not so high$(\leq50%)$.