• 제목/요약/키워드: Effects Measurements

검색결과 2,810건 처리시간 0.032초

스큐를 고려한 다극 영구자석 발전기의 전자기 특성해석/제어정수 도출을 통한 발전특성 예측 및 실험적 검증 (Experimental Verification and Prediction of Generating Performance of PMG with Multi-Pole Rotor based on Electromagnetic Analysis and Parameter Estimation considering Skew Effects)

  • 장석명;최장영;고경진;박지훈;이성호;김일중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.752-753
    • /
    • 2008
  • The analytical expressions for magnetic field distributions considering slotting effects, cogging torque and back-emf considering skew effects are established. On the basis of magnetic field solutions, electrical parameters such as back-emf constant and winding inductance are obtained. The predicted results are validated extensively by non-linear finite element (FE) analyses. In particular, test results such as back-emf, cogging torque, inductance and resistance measurements are given to confirm the analyses. Finally, generating performances are investigated by applying estimated parameters to equivalent circuit (EC) of the permanent magnet generator (PMG) and validated extensively by FE calculations and measurements.

  • PDF

나노인덴테이션을 이용한 인체 피질골 골층판의 물성연구 (Mechanical properties on nanoindentation measurements of osteonic lamellae in a human cortical bone)

  • 최환석;송정일;주원경
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.527-528
    • /
    • 2006
  • In the proposed research plan, the effects of anisotropic and time-dependent mechanical properties on nanoindentation measurements of osteonic lamellae in a human cortical bone are investigated. The most popular method(Oliver-Pharr method) in nanoindentation data analysis is based on the assumption of elastic isotropy. Since cortical bone has exhibited anisotropy, it is necessary to consider the effects of anisotropy on nanoindentation measurement for cortical bone. By comparison with the contact area obtained from monitoring the contact profile in FEA simulations, the Oliver-Pharr method was found to underpredict or overpredict the contact area due to effects of anisotropy. The mount of error depended on the indentation orientation. The indentation modulus results and were also similar to moduli calculated from mathematical model. The Oliver-Pharr method has been shown to be useful for providing first order approximations in analysis of anisotropic mechanical properties of cortical bone, although the indentation modulus is influenced by anisotropy.

  • PDF

The Ion Effect on Dewaterability of Alumina-Metal EDTA System

  • Kim, Jeung-Bea
    • 한국환경과학회지
    • /
    • 제12권5호
    • /
    • pp.559-564
    • /
    • 2003
  • The specific ion effects are observed in the alumina-metal EDTA(Ethylene Diamine Tetraacetic Acid) system. These effects seem to be associated with the fluidity of the metal ion in the complex. A consideration of the order of adsorption of the complexes on alumina indicates that a specific ion effect also affects the stability of the system. It is clear that EDTA and its heavy metal complexes have a significant effect on the dewaterability of alumina. These effects are not well represented by zeta potential measurements, especially for EDTA alone. With the nonspeciating complexes, though, the maximum permeability is predicted by the pH$\_$zpc/ from zeta potential measurements. At other pH value, the refiltration rate is better predicted by the state of coagulation as measured by log W.

뇌 확산강조 자기공명영상에 대한 정량적, 성적 평가: 1.5 T와 3.0 T 기기 비교 (Quantitative and Qualitative Evaluation of Brain Diffusion Weighted Magnetic Resonance Imaging: Comparision with 1.5 T and 3.0 T Units)

  • 구은회;동경래
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.227-230
    • /
    • 2016
  • DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging. In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5T and 3.0T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5T.

초음파기기를 통한 장부형상 및 호르몬검사로 확인한 조기난소부전 환자 치험 2례 (Two Cases of Oriental Medicine on Premature Ovarian Failure by Checking Ultrasonography and Serum Hormone Assay)

  • 고지은;유명숙
    • 대한한방부인과학회지
    • /
    • 제29권1호
    • /
    • pp.116-126
    • /
    • 2016
  • Objectives: The purpose of these cases is to report the effects of oriental medicine on two patients with premature ovarian failure. Methods: Two patients who had amenorrhea and hot flashes caused by premature ovarian failure were treated by oriental medicine such as herb medication. We estimated the effects of treatments by follow-up measurements of serum hormone level, menstrual cycle and symptoms. Besides, follicle and endometrium were checked by ultrasonography for academic research.Results After treatments, their symptoms of premature ovarian failure were improved and the menstrual cycle resumed. And the level of serum Follicle Stimulating Hormone decreased and the level of serum E2 increased.Conclusions Two cases shows that oriental medicine has effects on patients with premature ovarian failure by follow-up measurements of serum hormone level, menstrual cycle and symptoms.

선형 LSE 알고리즘을 이용한 신호원 위치 추정 성능 (Performance of LOB-based Emitter Localization Using Linear LSE Algorithms)

  • 이준호;김민철;조성우;김상원
    • 한국군사과학기술학회지
    • /
    • 제13권1호
    • /
    • pp.36-40
    • /
    • 2010
  • In this paper, the well-known LOB-based emitter localization using linear LSE algorithm is numerically implemented and the heuristic guidelines for the parameter values to achieve 1% RMS error are presented. In the simulation, we changed the total observation durations for LOB measurements, time interval between successive LOB measurements and sensor trajectories. The effects of the time interval of LOB measurements, the time duration of the LOB measurements and the angle of flight path arc on the performance are illustrated. The dependence of the performance on the various parameters is investigated and rule-of-thumbs for the parameter values corresponding to 1% RMS error are presented for each simulation condition.

Millimeter-wave diffraction-loss model based on over-rooftop propagation measurements

  • Kim, Kyung-Won;Kim, Myung-Don;Lee, Juyul;Park, Jae-Joon;Yoon, Young Keun;Chong, Young Jun
    • ETRI Journal
    • /
    • 제42권6호
    • /
    • pp.827-836
    • /
    • 2020
  • Measuring the diffraction loss for high frequencies, long distances, and large diffraction angles is difficult because of the high path loss. Securing a well-controlled environment to avoid reflected waves also makes long-range diffraction measurements challenging. Thus, the prediction of diffraction loss at millimeter-wave frequency bands relies on theoretical models, such as the knife-edge diffraction (KED) and geometrical theory of diffraction (GTD) models; however, these models produce different diffraction losses even under the same environment. Our observations revealed that the KED model underestimated the diffraction loss in a large Fresnel-Kirchhoff diffraction parameter environment. We collected power-delay profiles when millimeter waves propagated over a building rooftop at millimeter-wave frequency bands and calculated the diffraction losses from the measurements while eliminating the multipath effects. Comparisons between the measurements and the KED and GTD diffraction-loss models are shown. Based on the measurements, an approximation model is also proposed that provides a simple method for calculating the diffraction loss using geometrical parameters.

Wind load estimation of super-tall buildings based on response data

  • Zhi, Lun-hai;Chen, Bo;Fang, Ming-xin
    • Structural Engineering and Mechanics
    • /
    • 제56권4호
    • /
    • pp.625-648
    • /
    • 2015
  • Modern super-tall buildings are more sensitive to strong winds. The evaluation of wind loads for the design of these buildings is of primary importance. A direct monitoring of wind forces acting on super-tall structures is quite difficult to be realized. Indirect measurements interpreted by inverse techniques are therefore favourable since dynamic response measurements are easier to be carried out. To this end, a Kalman filtering based inverse approach is developed in this study so as to estimate the wind loads on super-tall buildings based on limited structural responses. The optimum solution of Kalman filter gain by solving the Riccati equation is used to update the identification accuracy of external loads. The feasibility of the developed estimation method is investigated through the wind tunnel test of a typical super-tall building by using a Synchronous Multi-Pressure Scanning System. The effects of crucial factors such as the type of wind-induced response, the covariance matrix of noise, errors of structural modal parameters and levels of noise involved in the measurements on the wind load estimations are examined through detailed parametric study. The effects of the number of vibration modes on the identification quality are studied and discussed in detail. The made observations indicate that the proposed inverse approach is an effective tool for predicting the wind loads on super-tall buildings.

혈당측정을 위한 폴리우레탄 진단막의 제조(6) : 헤마토크릿이 글루코우즈의 농도 측정에 미치는 영향 (Preparation of Polyurethane Diagnostic Membranes for Blood Glucose Measurements (6) : Effects of Hematocrit on Measurements of Glucose Concentration)

  • 권석기
    • 멤브레인
    • /
    • 제20권3호
    • /
    • pp.197-202
    • /
    • 2010
  • 당뇨병 환자의 혈당치 측정을 위하여 폴리우레탄으로 만들어진 진단막을 제조하였다. 혈액 속의 글루코우즈의 농도를 변화시켜가며 폴리우레탄 진단막을 가지고 680 nm에서의 최종흡광도를 측정하였다. 시간에 따른 흡광도 변화량(K/S)의 최종 결과치가 글루코우즈의 농도가 증가함에 따라 직선적으로 증가하였다. 헤마토크릿이 글루코우즈의 농도 측정에 미치는 영향을 조사하였다. 낮은 헤마토크릿에서는 글루코우즈의 농도와 K/S와의 기울기 값(Dose-Response Slope : DRS)이 플라즈마와 비교해 큰 차이를 보이지 않았다. 그러나 높은 헤마토크릿(40% 이상)에서는 상당히 감소함을 알 수 있었다.