• Title/Summary/Keyword: Effective volume

Search Result 2,439, Processing Time 0.028 seconds

Evaluation of Effective Wall Roughness for 3D Computational Analysis of Open Channel Flow (개수로 흐름의 3차원 전산해석을 위한 유효 벽면거칠기 산정)

  • Choi, Junwoo;Baek, Un Il;Lee, Sang Mok;Yoon, Sung Bum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6B
    • /
    • pp.627-634
    • /
    • 2008
  • In a numerical simulation of open channel turbulent flows using RANS (Reynolds averaged Navier-Stokes) equations model equipped with VOF (Volume of Fluid) scheme, the determination of wall roughness for wall function was studied. The roughness constant, based on the law-of-the-wall for flow on rough walls, obtained by experimental works for pipe flows is employed in general wall functions. However, this constant of wall function is the function of Froude number in open channel flows. Thus, the wall roughness should be determined by taking into account the effect of Froude number. In addition, the wall roughness should be corresponding to Manning's roughness coefficient widely used for open channels. In this study, the relation between wall roughness height as an input condition and Manning's roughness coefficient was investigated, and an equation for effective wall roughness height considering the characteristics of numerical models was proposed as a function of Manning's roughness coefficient.

Effectiveness of Electroacupuncture for Managing Urinary Retention Post Lumbar Spine Surgery: a retrospective single-cohort study

  • Phuong Dong Tran;Quoc Dung Nguyen;Thanh Duc Ngo
    • Journal of Pharmacopuncture
    • /
    • v.27 no.2
    • /
    • pp.123-130
    • /
    • 2024
  • Objectives: Post-operative urinary retention (POUR) is a frequent complication following surgical procedures, characterized by an acute inability to void, leading to additional complications and extended hospitalization. Acupuncture has been shown to be effective in facilitating spontaneous urination and alleviating anxiety in patients experiencing poor urination. The present study aims to evaluate the effectiveness of electroacupuncture in the management of POUR in patients who have undergone lumbar spine surgery. Methods: This retrospective study conducted at the National Hospital of Acupuncture in Vietnam and reviewed the medical records of patients over 18 years old who underwent lumbar spine surgery and were diagnosed with POUR between January to December 2019. Electroacupuncture was administered at five specific acupuncture points: Qugu (CV2), Zhongji (CV3), Zhibian (BL54), Pangguanshu (BL28), and Kunlun (BL60). This study monitored key parameters related to the effectiveness of the acupuncture treatment, including the number of acupuncture treatment sessions required until a patient was successfully treated was recorded, with a maximum of three acupuncture treatment sessions per patient, the time elapsed until urination following the treatment (minutes), and urinary bladder volume before and after treatment (mL). Results: The study demonstrated a 93.3% success rate in treating POUR with electroacupuncture. A significant reduction in post-void residual volume was noted, and patients could void within 30 minutes post-treatment. No significant differences in treatment effectiveness were observed across difference genders and age groups. Conclusion: Electroacupuncture proved to be a highly effective treatment for POUR in patients post-lumbar spine surgery, with a rapid response time and substantial reduction in PVR. However, the retrospective nature of the study and single-center focus limit its generalizability. Future research incorporating randomized controlled trials or multi-center observational studies are recommended to validate these findings and explore the potential of acupuncture in POUR management on a broader scale.

Convective Deposition of Silica Nano-Colloidal Particles and Preparation of Anti-Reflective Film by Controlling Refractive Index (콜로이드 실리카 나노입자의 부착에 의한 반사방지막 제조 및 굴절율 조절)

  • Hwang Yeon;Prevo Brian;Velev Orlin
    • Korean Journal of Materials Research
    • /
    • v.15 no.5
    • /
    • pp.285-292
    • /
    • 2005
  • Anti-reflection film was coated by using spherical silica nano colloids. Silica colloid sol was reserved between two inclined slide glasses by capillary force, and particles were convectively stacked to form a film onto the substrate as the water evaporates. As the sliding speed increased, the thickness of the film decreased and the wavelength at the maximum transmittance decreased. The microstructure observed by SEM showed that silica particles were nearly close packed, which enabled the calculation of the effective refractive index of the film. The film thickness was measured by proffer and calculated from the wavelength of maximum transmittance and the effective refractive index. The effective refractive index of the film could be controlled by a subtle controlling of the coating speed and by mixing two different sized silica particles. When the 100 nm and 50 m particles were mixed at 4:1-5:1 volume ratio, the maximum transmittance of $95.2\%$ for one-sided coating was obtained. This is the one that has increased by $3.8\%$ compared to bare glass substrate, and shows that $99.0\%$ of transmittance or $1.0\%$ of reflectance can be achieved by the simple process if both sides of the substrate are coated.

A Study on the Characteristics of the Spraying Nozzle on Paddy Levee (휴반 살포용 노즐의 분무특성에 관한 연구)

  • 최규홍;손낙율
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.2
    • /
    • pp.3758-3762
    • /
    • 1975
  • In order to find out the optimum size of nozzle of the power sprayer in the paddy field, four different sized hole of nozzles were tested on its discharge volume per unit time and its effective covering distance. 1. The discharge rate of each nozzle is proportional to square root of the transmitted internal pressure of liquid, and the discharge coefficient ranges from 0.82 to 0.86 at the pressure of 20 to 30 kg/$\textrm{cm}^2$. 2. The effective covering distance is increased as the size of the hole is larded and also the pressure is increased under under the limited pressure. Generally, the effective covering distance is not greatly increased at the pressure of above 25kg/$\textrm{cm}^2$. The distance from the nozzle to the spot where the largest amount of droplets are dropped is about 14.5m for 3.05mm nozzle and 16m for 4.05mm nozzle in the pressure range from 20 to 25kg/$\textrm{cm}^2$. 3. From the above results it is concluded that the 3mm nozzle with the power sprayers, which are now being supplied to the farmers, can be used for disease and insect control on the paddy field of which block size is 30m${\times}$100m, and operators need not to enter the field for spraying. For the 40m${\times}$100m block, 4mm nozzle should be used with large size of pump which discharge capacity is 60l/min or more.

  • PDF

Kalman Filter Estimation of the Servo Valve Effective Orifice Area for a Auxiliary Power Unit (보조 동력장치용 서보밸브 유효 오리피스 면적의 칼만필터 추정)

  • Zhang, J.F.;Kim, C.T.;Jeong, H.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Flow rate is one of the important variables for precise motion control and detection of the faults and fluid loss in many hydraulic components and systems. But in many cases, it is not easy to measure it directly. The orifice area of a servo valve by which the fluid flows is one of key factors to monitor the flow rate. In this paper, we have constructed an estimation algorithm for the effective orifice area by using the model of a servo valve cylinder control system and Kalman filter algorithm. Without geometry information about the servo valve, it is shown that the effective orifice area can be estimated by using only displacement and pressure data corrupted with noise. And the effect of the biased sensor data and system parameter errors on the estimation results are discussed. The paper reveals that sensor calibration is important in accurate estimation and plausible parameter data such as oil bulk modulus and actuator volume are acceptable for the estimation without any error. The estimation algorithm can be used as an useful tool for detecting leakage, monitoring malfunction and/or degradation of the system performance.

  • PDF

Optimization of Outdoor Cultivation of Spirulina platensis and Control ofContaminant Organisms (Spirulina platensis의 옥외배양 최적화 및 오염생물 구제)

  • Kim, Choong-Jae;Jung, Yun-Ho;Choi, Gang-Guk;Park, Yong-Ha;Ahn, Chi-Yong;Oh, Hee-Mock
    • ALGAE
    • /
    • v.21 no.1
    • /
    • pp.133-139
    • /
    • 2006
  • Outdoor cultivation of cyanobacterium Spirulina platensis was carried out for 40 days in a batch mode. A half concentration of the SOT based on the underground water was used as culture medium. Working volume was 5.7 tons with 0.2 m depth. During cultivation, mean water temperature, DO and light intensity were all in proper conditions for the S. platensis growth. The adjustment of pH to over 10 with Na2CO3 and addition of the 1.5% natural salt were very effective to delete contaminant organisms, Chlamydomonas moewusii and Chlorella minutissima occurred one after the other in the culture. The mean productivity of the biomass based on the dry cell weight from 14 to 25 days, after the contaminants were deleted, was 7.8 g ·m–2· d–1, which was relatively high productivity in that a half concentration of the SOT was used for the culture. Underground water used in the culture minimized contaminants invasion and addition of the 1.5% natural salt was effective to delete contaminants as well as acted as mineral supplement in outdoor cultivation of S. platensis. Harvesting using the floating activity of S. platensis was effective from mass floating in day time after overnight without agitation and illumination.

A Study on Selection of Effective Engineering Design Problem based on LEGO Mindstorm NXT for Basic Design Education (레고 마인드스톰 NXT를 활용한 기초설계 교과목에서의 효과적인 공학설계과제 선정방안 연구)

  • Shin, Youn-Soon;Sohn, Dai-Geun;Lee, Kyung-Ho;Hong, Sung-Ho;Lee, Kangwoo;Jung, Jin-Woo
    • Journal of Engineering Education Research
    • /
    • v.19 no.2
    • /
    • pp.60-69
    • /
    • 2016
  • This paper deals with the selection method of effective engineering design problem based on LEGO Mindstorm NXT for basic design education. By YouTube case study of various LEGO-based engineering designs for olympic sports, performance criteria have been developed including programming complexity, structural complexity, sensor/actuator complexity and variety of game operation. Programming complexity includes range of programming code length and possible program variety. Structural complexity includes variety of structural elements such as length, shape, weight, and volume to overcome design restrictions. Sensor/actuator complexity includes variety of sensor used and number of possible actuator assemblies. Variety of game operation includes game complexity and required creativity to make LEGO robots. Based on these performance criteria, four representative sports were selected as the candidates for effective engineering design problem. Finally, feasibility and attributes of each candidate were verified by real implementation examples.

A Behavior of Embrittlement at the Subsurface Zones of Multiphase Steels Charged with Hydrogen (수소주입시킨 다상조직강의 Subsurface Zone 내 취성화 거동)

  • Kang, Kae-Myung;Park, Jae-Woo;Choi, Jong-Un
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.1
    • /
    • pp.48-53
    • /
    • 2013
  • In the present work, it was investigated a behavior of hydrogen embrittlement at the subsurface zones of 590 DP steels by using the micro-Vickers hardness test. The micro-Vickers hardnessess of DP steels were measured to evaluate the degree of embrittlement as the effective hardening depths of subsurface zones with hydrogen charging conditions. The results showed that the distributions of micro-Vickers hardness in width varied from maximum hardness 239.5 Hv to minimum hardness 174 Hv, while the depth of effective hardening layer at the subsurface zones of DP steels was from $320{\mu}m$ to $460{\mu}m$ with hydrogen charging conditions, respectively. It was proposed that the distribution of microhardness be used as the evaluation index of the degree of embrittlement. But the variations of martensite volume fractions were not affected along depth of hardening at the same changing time, hydrogen charging times were appeared as an effective factor of the degree of embrittlement. Therefore, the micro-Vickers hardness test is an attractive tool for evaluation of hydrogen embrittlement at the subsurface zones of these DP steels.

Changes in quality of cardiopulmonary resuscitation over time on CPR and related rescuer (구조자 특성별 심폐소생술 지속시간에 따른 질 변화)

  • Yoou, Soon-Kyu;Choi, Hea-Kyung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.3
    • /
    • pp.103-115
    • /
    • 2012
  • Purpose : Inadequate chest compression during cardiopulmonary resuscitation(CPR) may result in the insufficient blood flow to preserve critical organ function. The study evaluated changes of quality of cardiopulmonary resuscitation over time in 30:2 CPR by laypersons and analyzed rescuer factors affecting the quality of chest compressions over time. Methods : This study was designed to know quality of CPR changes during 5 minutes. 47 students completed CPR training courses. They were performed 30:2 CPR using a manikin with Skill-Reporter for 5 minutes continuously to get data of depth, rate of chest compression, volume and correct rate of ventilation. Results : Time dependent analysis showed significant ineffective compression depth in females and under weight rescuers. In case of female, we found effective compression depth has maintained up to 2 minutes, but it decreased significantly after 2 minutes. However, underweight rescuers maintained effective compression depth up to a minute but it decreased after 1 minute. Conclusion : Although compression rate maintained over time, chest compression quality declined significantly. It suggested switching compression at an interval of 2 minutes is reasonable for 30:2 CPR by layperson but underweight rescuers may provide effective chest compression by switching shift every one minute.

Rock Crushing and Gel Crushing of Ocean Traffic Facilities Foundation (해양교통시설기초 암반파쇄와 겔파쇄)

  • Lee, Soo-Gwan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.06a
    • /
    • pp.419-424
    • /
    • 2009
  • The ocean rock was crushed mainly by drop hammer and blasting. In recent years, because of farming and harbors extension, the ocean rock crushing method is changing to popular complaint solving type. Effective rock crushing methods of protecting environment are studied under consideration for topography, farming, structures, electronic equipment, environment protection arm near to rock crushing sector. Effective rock crushing methods are compared under consideration for crushing volume, rock quality, distribution, crushing speed. Effective rock crushing methods at once solving popular complaint and protecting ocean environment and building ocean structures, are compared according to the coast development.

  • PDF