• Title/Summary/Keyword: Effective protection methods

Search Result 349, Processing Time 0.027 seconds

A Review on the Sihocheonggan-tang & Sihocheonggan-san for the treatablity of Atopic Dermatitis (국내 논문 검색을 통한 시호청간탕(柴胡淸肝湯)과 시호청간산(柴胡淸肝散)의 아토피 피부염 치료 가능성에 관한 고찰)

  • An, Jae-Hyun;Hwang, Mi-Lee;Yoon, Hwa-Jung;Jung, Hyun-A
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.30 no.1
    • /
    • pp.10-16
    • /
    • 2017
  • Objectives : Atopic Dermatitis is a recurrent, chronic, allergic eczema with severe itching sensation. This study designed to research Sihocheonggan-tang & Sihocheonggan-san to find out treatability for atopic dermatitis. Methods : We got 14 search results with searching word '시호청간탕', '시호청간산' in 'OASIS', 'NDSL', 'RISS'. We classified these studies according to the type of study, diseases, treatment methods and treatment outcomes. Results : In the analysis of the diseases, Sihocheonggan-tang & Sihocheonggan-san was given for Eczema nummulare, Ermatitis seborrheica, Erythema multiforme, Eczema and Atopic dermatitis. In the analysis of the treatment methodes, the dosage form of Sihocheonggan-tang & Sihocheonggan-san was herbal medication, pill, granules and herbal medication & pill. In the analysis of the treatment outcomes, the symptoms of all patients were improved. In the experimental researches, it was proved that Sihocheonggan-tang & Sihocheonggan-san has effects that affect anti-inflammatory, skin protection and recovery of keratinocyte. Conclusions : For this study, we can consider Sihocheonggan-tang & Sihocheonggan-san is effective for atopic deramatitis. So, it is necessary to carry out clinical trial for Sihocheonggan-tang & Sihocheonggan-san in atopic dermatitis to evaluate safety and efficacy.

Development of a Simultaneous Analytical Method for Diquat, Paraquat and Chlormequat in Animal Products Using UPLC-MS/MS

  • Cho, Il Kyu;Rahman, Md. Musfiqur;Seol, Jae Ung;Noh, Hyun Ho;Jo, Hyeong-Wook;Moon, Joon-Kwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.4
    • /
    • pp.368-374
    • /
    • 2020
  • BACKGROUND: The residual analysis of polar pesticides has remained a challenge. It is even more difficult to simultaneously analyze multiple polar pesticides. Diquat, paraquat, and chlormequat are typical examples of highly polar pesticides. The existing methods for the analysis of diquat, paraquat and chlormequat are complex and time consuming. Therefore, a simple, quick and effective method was developed in the represent study for simultaneous analysis of diquat, paraquat and chlormequat in animal products, meat and fat using UPLC-MS/MS. METHODS AND RESULTS: Sample extraction was carried out using acidified acetonitrile and water and re- extracted with acidified acetonitrile and combine the extracts followed by centrifugation. The extract was then cleaned up with a HLB cartridge after reconstitution with acidic acetonitrile and water. The method was validated in quintuplicate at three different concentrations. The limits of detection (LOD) and quantification (LOQ) were 0.0015 and 0.005 mg/L, respectively. Matrix suppression effect was observed for all of the analytes. A seven point matrix matched calibration curve was constructed for each of the compound resulted excellent linearity with determination coefficients (R2) ≥ 0.991. Accuracy and precision of the method was calculated from the recovery and repeatability and ranged from 62.4 to 119.7% with relative standard deviation less than 18.8%. CONCLUSION: The recovery and repeatability of the developed method were in the acceptable range according to the Codex Alimentarius guideline. The developed method can be applied for the routine monitoring of diquat, paraquat, and chlormequat in animal products, meat and fat.

A dose monitoring system for dental radiography

  • Lee, Chena;Lee, Sam-Sun;Kim, Jo-Eun;Symkhampha, Khanthaly;Lee, Woo-Jin;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Yeom, Heon-Young
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. Materials and Methods: An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. Results: The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. Conclusion: A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

Study on elements for effective infection control at dental hospitals (효과적인 치과병원 감염관리의 구성요소에 대한 고찰)

  • Bae, Sung-Suk;Lee, Myung-Sun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.4
    • /
    • pp.557-569
    • /
    • 2011
  • Objectives : Based on the system and control activity for the monitoring system made of components for infection control at dental hospitals and infection rate reporting, and the role of trained infection control staff, this study tried to understand approaches to the effective infection control program by surveying infection control at dental hospitals in Korea. Methods : The survey was conducted from December 14,2010 to January 31,2011 for 121 dental hospitals in Korea. For statistical analysis, PASW Statistic 18 was used. Results : And following conclusions were reached. 1. As for the infection control system at dental hospitals, 54.7% has an infection control committee, 58.7% infection control staff, 78.5% infection control rules, and 39.7% annual infection control plan and record. 2. As for surveillance indexes to report infection rates, 50.4% has the reporting system for staff's exposure to infectious disease and needle pricking. The average number of exposures to infectious disease was $0.28{\pm}2.23$ and that of needle pricking was $1.83{\pm}5.39$. 3. As for infection control indexes, it was reviewed whether infection control rules were implemented according to operation agents, general hospitals were more active in staff infection control, and hospitals annexed to a dental university or special legal entity were more active in microorganism control. As for use of personal protection gear, there was no significant difference among operation agents. More than 71% of operators and their assistants said they did not replace their masks between patients. 4. As for personnel indexes for effective infection control staff, most hospitals designated dental hygienists, which was followed by dental doctors (or doctors). Where their workload was reviewed, the ratio of other work such as treatment was relatively higher than that of infection control (n=71). Conclusions : These results show dental hospitals in Korea have a certain level of infection control system. As infection indexes are managed mainly for staff members, patient monitoring is needed, and trained and effective infection control staff should be designated. This study reviewed surveillance, infection control and personnel indexes. And further studies are needed in the future.

Evaluation of Effective Dose and Exposure Level of Radon in Process Handling NORM (인산석고 취급공정에서의 라돈농도 및 유효선량 수준 평가)

  • Chung, Eun Kyo;Jang, Jae Kil;Kim, Jong Kyu;Kim, Joon Beom;Kwon, Jiwoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.3
    • /
    • pp.283-291
    • /
    • 2018
  • Objectives: To monitor the radon concentration level in plants that handle phosphorus rock and produce gypsum board and cement, and evaluate the effective dose considering the effect of radon exposure on the human body. Methods: Airborne radon concentrations were measured using alpha-track radon detectors (${\alpha}$-track, Rn-tech Co., Korea) and continuous monitors (Radon Sentinel 1030, Sun Nuclear Co., USA). Radon concentrations in the air were converted to radon doses using the following equation to evaluate the human effects due to radon. H (mSv/yr) = Radon gas concentration x Equilibrium factor x Occupancy factor x Dose conversion factor. The International Commission on Radiological Protection (ICRP) used $8nSv/(Bq{\cdot}hr/m^3)$ as the dose conversion factor in 2010, but raised it by a factor of four to $33nSv/(Bq{\cdot}hr/m^3)$ in 2017. Results: Radon concentrations and effective doses in fertilizer manufacturing process averaged $14.3(2.7)Bq/m^3$ ($2.0-551.3Bq/m^3$), 0.11-0.54 m㏜/yr depending on the advisory authority and recommendation year, respectively. Radon concentrations in the gypsum-board manufacturing process averaged $14.9Bq/m^3$ at material storage, $11.4Bq/m^3$ at burnability, $8.1Bq/m^3$ at mixing, $10.0Bq/m^3$ at forming, $8.9Bq/m^3$ at drying, $14.7Bq/m^3$ at cutting, and $10.5Bq/m^3$ at shipment. It was low because it did not use phosphate gypsum. Radon concentrations and effective doses in the cement manufacturing process were $23.2Bq/m^3$ in the stowage area, $20.2Bq/m^3$ in the hopper, $16.8Bq/m^3$ in the feeder and $11.9Bq/m^3$ in the cement mill, marking 0.12-0.63 m㏜/yr, respectively. Conclusions: Workers handling phosphorous gypsum directly or indirectly can be assessed as exposed to an annual average radon dose of 0.16 to 2.04 mSv or 0.010 to 0.102 WLM (Working Level Month).

Marine Environmental Assessment based on the Benthic Macroinfaunal Compositions in the Coastal Area of Inchon, Korea (인천연안역 저서동물의 종조성을 이용한 환경평가)

  • LEE Jae-Hac;KOH Byoung-Seol;PARK Heung-Sik
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.5
    • /
    • pp.771-781
    • /
    • 1997
  • In order to select an effective and appropriate evaluation method for the marine environmental protection and management, it is necessary to evaluate the present status of environmental conditions and to monitor and regulate the harzadous waste continuously. Among the evaluation methods that use benthic fauna, some graphical methods and biological index methods such as species abundance-biomass (SAB), Rank-frequency diagram (RFD), Abundance-Biomass comparison (ABC), log-normal distribution (LND), and Benthic Pollution Index (BPI) modified by Infaunal Trophic Index were used for the assessments of marine environment in the Inchon coastal area. Even though the graphic methods are convenient for easy glimpse of general trend of environmental condition but because they require sufficient ecological data, those methods do not fit for analysis or comparison of regional and detailed environmental condition. On the other hand, when BPI was applied, it was able to compare the spatial benthic conditions. Through considering the functional aspects of benthic fauna which can not be obtained in the cluster analysis, BPI was made it possible to measure or trace down the source of pollution. In the case of the environmental assessment result analyzed in Inchon coastal area, the north eastern part of Yongjongdo was more influenced by the pollution than the outer area of Inchon. The research indicates that especially Inchon harbor has been greatly affected.

  • PDF

Comparison of Fit Factor for Healthcare Workers Before and After Training with the N95 Mask (의료용 N95 마스크 착용방법에 대한 교육 전·후 밀착계수 비교)

  • Kim, Hyunwook;Baek, Jung Eun;Seo, Hye Kyung;Lee, Jong-Eun;Myong, Jun-Pyo;Lee, Seung-Joo;Lee, Jin-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.528-535
    • /
    • 2014
  • Objectives: This study compares the differences of fit factors before and after training on the N95 mask. The results will be utilized to suggest the need of providing effective training on respirator use. Methods: A total of 49 study subjects were tested, comprised of nurses from a general hospital and undergraduate nursing students from a medical school. Anthropometric measurements of face length and face width were compared with the NIOSH(National Institute for Occupational Safety and Health) panel. Fit factors(FF) were measured with TSI Portacount Pro+8038 before and after on-site training regarding the proper use of respirators. The FF pass/fail criterion was set at 100. Results: Two subjects(4.1 %) passed the fit test before training on use of the N95. However, 36(73.5%) of the 49 passed the test after training. Overall the FF(GM(GSD)) was 13.4(3.2) before training, but improved to 106.6(2.1) after training, which was statistically significant. These findings suggest the efficacy of educational intervention, and the performance of the direct on-site training proved to be better than that of the traditional educational methods. Conclusions: This study showed the effect of on-site training of the N95 respirator among health care workers(HCW). Therefore, providing effective training on the use of N95 for HCWs before their work assignments will greatly reduce exposure to harmful agents. It is recommended that fit testing be mandated to check for adequate protection being provided by the given respirators.

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF

Comparison of Runoff Models for Small River Basins (소하천 유역에서의 유출해석모형 비교)

  • 강인식
    • Water for future
    • /
    • v.29 no.4
    • /
    • pp.209-221
    • /
    • 1996
  • It may be difficult to make exact estimates of peak discharge or runoff depth of a flood and to establish the proper measurement for the flood protection since water stages or discharges have been rarely measured at small river basins in Korea. Three small catchments in the Su-Young river basin in Pusan were selected for the study areas. Various runoff parameters for the study areas were determined, and runoff analyses were performed using three different runoff models available in literatures; the storage function method, the discrete, linear, input-output model, and the linear reservoir model. The hydrographs calculated by three different methods showed good agreement with the observed flood hydrographs, indicating that the models selected are all capable of sucessfully modeling the flood events for small watersheds. The storage function method gave the best results in spite of its weakness that it could not be applicable to small floods, while the linear reservoir model was found to provide relatively good results with less parameters. The capabilities of simulating flood hydrographs were also evaluated based on the effective rainfall from the storage function parameters, the $\Phi$-index method, and the constant percentage method. For the On-Cheon stream watershed, the storage function parameters provided better estimates of effective rainfall for regenerating flood hydrographs than any others considered in the study. The $\Phi$-index method, however, resulted in better estimates of effective rainfall for the other two study areas.

  • PDF

Acaricidal Efficacy of Herbal Extracts against Tetranychus urticae (Acarina: Tetranychidae) (점박이응애, Tetranychus urticae (Acarina: Tetranychidae)에 대한 약용식물 추출물의 살비 효과)

  • Lee, Jung-Su;Ham, Eun-hae;Choo, Ho-Yul;Lee, Suk-Jun;Lee, Dong-Woon
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.151-162
    • /
    • 2011
  • Methanol and hexane extracts from 35 species in 27 families of herbal plants were evaluated for their acaricidal activities against two-spotted spider mite, Tetranychus urticae by leaf-dipping and spraying methods in laboratory, pot and field, respectively. Acaricidal activities were different depending on herbal plants. When T. urticae was released on leaves of Phaseolus vulgaris var. humilis that were dipped in the 1,000 ppm hexane extracts from fruits of Torreya nucifer and Daphan genkwa, seeds of Xanthium strumarium and Pharbitis nil at one minute they experienced 56.8, 47.8, 47.7, and 47.7% mortalities, respectively. Dipping time influenced acaricidal activity, that is, one minute dipping was more effective than 30 second dipping of Phaseolus vulgaris var. humilis leaves. However, extracts of X. strumarium and P. nil seeds had comparatively high activities. Concentration of hexane extract of X. strumarium and P. nil seeds revealing LC50 were 1,824 and 1,899 ppm, respectively. Extracts of both plants from hot and cold water were not effective representing <20% mortality at 1,000 ppm. However, hexane extracts of X. strumarium and P. nil seeds were effective against T. urticae on P. vulgaris var. humilis representing 76.3 and 71.3% mortalities in pot, respectively. Control effects of hexane extract of P. nil seed were 50.8 and 35.1% at 2,000 and 1,000 ppm against T. urticae on Chrysanthemum morifolium in greenhouse, respectively.