• Title/Summary/Keyword: Effective power

Search Result 5,413, Processing Time 0.033 seconds

A Design of Power-saving PC System Using the IP Address Restriction (IP 주소 제한을 이용한 PC 절전 시스템의 설계)

  • Kim, Hong Yoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.2
    • /
    • pp.89-97
    • /
    • 2013
  • The green IT technology is being introduced in diverse sectors, especially in the data center and green computer sectors. Rack-type PCs, which have been developed by improving the computer hardware, are effective for data centers and large businesses, but they are not usually introduced in small organizations such as small and medium businesses and schools because they require high initial costs. Power-saving PC software enables the inexpensive power control, but the installation of the power-saving software in all computers in the organization is not an easy task. Computer users in the organization are usually not cooperative as they do not think the power-saving cost is directly related to themselves. In this paper, a technique wherein the server has a restriction in providing the IP address to the computers that has no power-saving software is proposed, so that users will cooperate in the PC power-saving system to avoid inconvenience. In order to provide restricted IP address periodically, the server makes a request of power-saving software installation check for user's PC. Proposed technique is more effective ways to save computer energy, because it does not depend on specific systems or organizations.

An Experimental Study to Determine the Effective Prestress force of PSC Beam (PSC 부재의 유효 프리스트레스력 평가를 위한 실험적 연구)

  • Chung, Chul-Hun;Park, Jae-Gyun;Kim, Kwang-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.21-29
    • /
    • 2008
  • To evaluate the structural integrity of the NPP containment building more rigorously, the effective prestress, which is one of the most affecting elements, needs to be estimated exactly. This paper presents the results of an experimental study to determine the effective prestress force in prestressed concrete beams. It is possible to improve the effective prestress measuring method by test beam, which is being applied for the investigation of the nuclear power plant in operation. If experimentally evaluated Lift-Off method in this study can be coupled with test beam test currently being used in in-service nuclear power plant, it is possible to measure prestress loss of the tendon and the level of the effective prestress load.

The Current Status and the Prospects of Wind Energy (풍력발전기술의 현황과 전망)

  • Jang, Moon-Seok;Bang, Hyung-Joon
    • Journal of Environmental Science International
    • /
    • v.18 no.8
    • /
    • pp.933-940
    • /
    • 2009
  • Recently, wind power generation is an emerging industry expanding its market rapidly thanks to the increasing need to solve the scarcity of fossil fuels and the risk of potential global warming. Wind power generation has shown to be an effective response plan to global warming, showing the most price competitiveness among the renewable energy sources by its higher efficiency. Therefore wind energy has attracted considerable attention as the industrial growth drive for the next generation. Considering Korea's high dependence of overseas energy resources, the importance of wind power is growing as the most effective alternative energy source to ensure energy security as well as becoming a key strategic industry for exports. In this study, the social and economic effects of the wind power industry is discussed and the current status and the future prospects of the wind energy market is also examined.

Development of a 3-D Visualization Application for Management of Substation Equipment

  • Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.3
    • /
    • pp.38-44
    • /
    • 2009
  • This paper presents a new windows application based on 3-D graphics and Text-To-Speech (TTS) for effective management of substation equipment. When problems in a power system occur, inexperienced power system operators may have difficulty in understanding the situation as well as finding suitable countermeasures quickly. This paper addresses an effective scheme to visualizing power system equipment under normal and abnormal conditions using 3-D graphics and animations. In addition, the state variations and the order of maintenance priority of substation equipment are represented by TTS and intuitive methods. The proposed system can help power system operators to more quickly understand the state of power system equipment, and it can provide operators with the suitable countermeasures for minimizing damage caused by equipment problems.

Sensitivity-Based Method for the Effective Location of SSSC

  • Eghtedarpour, Navid;Seifi, Ali Reza
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.90-96
    • /
    • 2011
  • Congestion management is one of the most challenging aspects in the recently deregulated electricity markets. FACTS devices have been shown to be an efficient alternative to control the flow of power in lines, resulting in increased loadability, lower system loss and a reduced cost of production. In this paper, the application of a static series synchronous compensator (SSSC) for the purpose of congestion management of power systems has been studied. A sensitivity-based analysis method is utilized for effective determination of the SSSC location in an electricity market. The method is topology based and it is independent of the system operation point. A power injection p-model is developed for the SSSC in this study. Numerical results based on the modified IEEE 14 bus system with/without the SSSC demonstrate the feasibility as well as the effectiveness of the SSSC for congestion management in a network. The results obtained when using the SSSC to improve system transfer capability and congestion management is encouraging.

A Study of Thermal Radiation from The Alumina Particle Cloud in The Plume Using View Factor Method (형상 계수를 이용한 알루미나 입자구름의 열복사 예측 기법 연구)

  • Ko, Ju-Yong;Kim, In-Sun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2044-2049
    • /
    • 2007
  • In order to predict the thermal radiation induced from alumina particle cloud in the plume of solid propellant motor, view factor method is applied to space shuttle SRB and the result is compared with that of monte carlo method. For this purpose, radiative characteristics, such as particle cloud temperature distribution, effective emissivity or emissive power of particle cloud are studied. In the case of effective emissivity, inverse wavelength method is applied and plume reduction characteristic length is used for emissive power distribution. As a result, thermal radiation using view factor method gives more conservative results than that using monte carlo method. So it can be used for preliminary design of thermal protection system.

  • PDF

A Study of an Effective Database Design Method for Power System Protection (효율적인 계통보호 데이터베이스 디자인 방법에 관한 연구)

  • Ahn, Y.T.;Choi, M.S.;Lee, S.J.;Kang, S.H.;Kim, H.P.;Choi, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.905-907
    • /
    • 1998
  • The setting of protective relays, which is critical to the system security, requires a huge volume of data and a lot of repetitive calculations. Since an effective design of a database is essential. The relay setting database must accommodate a variety of protective devices. Also its information can be viewed and updated with easy by humans and by computer programs. This paper describes several existing database designs for power system protection, their advantages and disadvantages. Also this paper develops an effective database for power system protection with their advantages.

  • PDF

Characteristics of Drag Reduction Additives in the Application of District Cooling System (지역냉방시스템에의 적용을 위한 마찰저항감소 첨가물 특성 연구)

  • 윤석만;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.251-257
    • /
    • 2000
  • District heating and cooling systems offer highly efficient energy utilization and maintenance by centralizing heat management. More pumping power, however, is required because the water has to travel long distance from heat source to the users. In the present study, a trace of drag reduction additives is added to the District Cooling system to achieve a significant drag reduction and save pumping power. Water-soluble polymers, surfactants, and environment-friendly degradable polymers are used as effective drag reducing additives. Time dependent percent drag reductions are compared for various additive solutions at 100 wppm concentration for different water velocity. Without as an anionic surfactant, copolymer was most effective in percent drag reduction. It is found that there exists an optimal condition when copolymer is mixed with SDS. An environment-friendly degradable polymer, xanthan gum, is found to be a significant drag reduction additive. Ice slurry systems, can give less pressure drops compared with chilled water system for certain condtions. Drag reduction additives were also effective for the ice slurry system.

  • PDF

The Configuration of Power Demand Control System (전력수요 제어 시스템 구성 방안)

  • 송언빈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.107-110
    • /
    • 1993
  • This paper presents the technical requirements and configuration of power demand control system in office building Generally, the peak power demand is occurred in cooling period. For power demand control in existing building, the most effective control points are the motors for air handling units.

  • PDF

A New Support Vector Machine Model Based on Improved Imperialist Competitive Algorithm for Fault Diagnosis of Oil-immersed Transformers

  • Zhang, Yiyi;Wei, Hua;Liao, Ruijin;Wang, Youyuan;Yang, Lijun;Yan, Chunyu
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.830-839
    • /
    • 2017
  • Support vector machine (SVM) is introduced as an effective fault diagnosis technique based on dissolved gases analysis (DGA) for oil-immersed transformers with maximum generalization ability; however, the applicability of the SVM is highly affected due to the difficulty of selecting the SVM parameters appropriately. Therefore, a novel approach combing SVM with improved imperialist competitive algorithm (IICA) for fault diagnosis of oil-immersed transformers was proposed in the paper. The improved ICA, which is proved to be an effective optimization approach, is employed to optimize the parameters of SVM. Cross validation and normalizations were applied in the training processes of SVM and the trained SVM model with the optimized parameters was established for fault diagnosis of oil-immersed transformers. Three classification benchmark sets were studied based on particle swarm optimization SVM (PSOSVM) and IICASVM with four multiple classification schemes to select the best scheme for transformer fault diagnosis. The results show that the proposed model can obtain higher diagnosis accuracy than other methods. The comparisons confirm that the proposed model is an effective approach for classification problems.