• Title/Summary/Keyword: Effective discharge

Search Result 1,002, Processing Time 0.027 seconds

A study on the dominant discharge in small and medium-sized stream (Yo-Stream) (중소하천(요천)에서 지배유량 연구)

  • Rim, Chang-Soo;Lee, Joon-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.2
    • /
    • pp.309-314
    • /
    • 2011
  • The purpose of this study is to select the dominant discharge which mostly affects the formation of the channel shape in Yo-Stream. So far, three different discharge conditions such as bankfull discharge, discharge of a specific recurrence interval, and effective discharge have been considered as an indicator of dominant discharge. Therefore, three different discharge conditions were studied and based on the study results, dominant discharge was selected for Yo-Stream. When comparing bankfull discharge and effective discharge at Beonam stream gaging station, it has turned out that effective discharge was 10 $m^3$/sec, which is 6 times greater than bankfull discharge of 58.83 $m^3$/sec. Furthermore, when comparing bankfull discharge and discharge of a specific recurrence interval, bankfull discharge was quite similar to discharge with recurrence interval of 1.52 years. Previous study results also indicate that dominant discharge occurs with recurrence interval of similar duration. Therefore, discharge of 58.83 $m^3$/sec was considered as a dominant discharge, which corresponds to discharge with recurrence interval of 1.52 years.

A Study on Correlation of Effective Discharge Energy and Exhaust Emission of Gasoline Vehicle (가솔린자동차의 유효방전에너지와 배기가스와의 상관관계 연구)

  • Yoo, Jongsik;Kim, Chulsoo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.7
    • /
    • pp.70-75
    • /
    • 2014
  • The experiment was done on traveling at the speed of 20km/h, 60km/h and 100km/h using the performance testing mode for chassis dynamometer. The experimental method were employed to measure the waveform of secondary ignition coil and exhaust emission. In this experiment, the correlation between the secondary waveform coming from ignition coil and exhaust emission were measured in decrepit vehicle. The secondary waveform characterized by the value of effective discharge energy. The following results are obtained by analyzing the data relativity between the effective discharge energy and exhaust emission. The variation rate of effective discharge energy was largest 60km/h, 20km/h, 100km/h velocity in the ordered named. As the vehicle velocity increases, the average variation rate of CO and $NO_X$ decreases and that of HC and $CO_2$ decrease. The value of effective discharge energy, CO, $NO_X$ and fuel consumption is measured badly in case of car with failures in MAP, spark plug and good in case of car with before and after maintenance regardless of vehicle velocities. The value of effective discharge energy is to be nearly parabolic shape as vehicle velocity increases. As the value of effective discharge energy increases, the value of $NO_X$, HC and $CO_2$ decrease, the value of CO increase. The most sensible factors of exhaust emission were CO, $NO_X$, and the small variation factors were HC, $CO_2$.

Evaluation of Channel-forming Discharge for the Abandoned Channel Restoration Design of Cheongmi Stream (청미천 구하도 복원 설계를 위한 하도형성유량 산정)

  • Ji, Un;Kang, Jun-Gu;Yeo, Woon-Kwang;Han, Seung-Won
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.12
    • /
    • pp.1113-1124
    • /
    • 2009
  • The abandoned channel restoration is one of methods to enhance the environmental function and ecological habitat as well as the functions of water-utilization and flood control. The channel-forming or dominant discharge must be evaluated and defined to design the cross-sectional and plane geometries of the stable and equilibrium channel for the abandoned channel restoration project. In general, bankfull discharge, specified recurrence interval discharge, and effective discharge have been used to decide the channel-forming discharge. In this study, bankfull discharge, specified recurrence interval discharge, and effective discharge were calculated and compared for the abandoned channel restoration site of Cheongmi Stream and their relations to historical bed changes were analyzed. The bankfull discharge, 488 $m^3/s$, of the abandoned channel restoration site of Cheongmi Stream was calculated using HEC-RAS data and ranged between 1.5-year and 2-year recurrence discharges. Also, the effective discharge evaluated with the sediment rating curve and mean daily discharge data is greater than the bankfull discharge. According to the survey data of 1994 and 2008, the bed elevation of the study reach was decreased over time. It is indicated that the channel bed is changing to the stable condition to allow the effective discharge.

A Study of Effective Discharge Method for Sedimentation Sludge (침전슬러지의 효율적인 배출방안에 관한 연구)

  • Oh, Sueg-Young;Byun, Doo-Gyoon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.2 s.29
    • /
    • pp.16-22
    • /
    • 2005
  • This research inspects the discharge state for inside of sedimentation basin, and, through the aboard literature and data, examine sedimentation sludge about discharge plan of effective sedimentation sludge that can discharge in state of high concentration. In this study, we are going to attempt an economy with improvement efficiency for discharge of sedimentation sludge in a water treatment plant.

A Study on effective Discharge Equipment for Sedimentation Basin (효율적인 침전슬러지 배출설비에 관한 연구)

  • Park, Jae-Kyeoung;Oh, Sueg-Young;Lee, Nam-Young;Oh, Jeong-Jin
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.259-264
    • /
    • 2003
  • This research inspects discharge state of inside of sedimentation basin, md, through the aboard literature and data, examine sedimentation sludge about discharge plan of effective sedimentation sludge that can discharge in state of high concentration.

  • PDF

Channel-forming Discharge Evaluation for Rivers with High Coefficients of River Regime (하상계수가 큰 하천의 하도형성유량 산정)

  • Ji, Un;Jang, Eun Kyung;Yeo, Woon Kwang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4B
    • /
    • pp.361-367
    • /
    • 2011
  • The channel-forming discharge, which is a standard and single flow for the river maintenance and restoration project, should be estimated necessarily in the stable channel design. It is difficult to produce the specific pattern for the channel-forming discharge in the domestic rivers due to the insufficient researches and case studies. Also, it is improper to adopt the foreign cases for the domestic rivers and streams which have the high coefficients of river regime. Therefore, the channel-forming discharge possible to use for rivers with high coefficients of river regime is suggested in this study through analyzing the bankfull, specified recurrence interval, and effective discharges of Mangyeong River, Cheongmi Stream, and Hampyeong Stream for the abandoned channel restoration project. The bankfull discharge was calculated with geometric data using the HEC-RAS modeling and the flow, bed materials, and sediment data for the study reaches were used to estimate the specified recurrence interval and effective discharges. As a result for calculating the channel-forming discharge, the effective discharge was greater than the bankfull discharge in the river with high coefficient of river regime and the effective discharge was greater than the bankfull and there was no correlation between the coefficient of river regime and the characteristics of the specified recurrence interval discharges.

Effective Ozone Generation Utilizing a Slit Barrier (틈새 장벽을 이용한 효과적인 오존 발생)

  • Moon, Jae-Duk;Jung, Jae-Seung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.323-327
    • /
    • 2006
  • In this paper a new wire-wire discharge system with a slit dielectric harrier has been proposed, and, its corona discharge and ozone generation characteristics have been investigated experimentally. When the slit mica barrier is installed between corona wires, instead of the grounded plate electrode, a significant increase in the generation of ozone, about 2.2 times higher than that of the conventional ones without the slit harrier, could be obtained. Photographs show that this type of discharge system with a slit barrier was found to produce a corona discharge twice, once from the upper and bottom corona wires, and. again from both sides of surfaces and slits of the slit barrier. As a result, the proposed discharge system has the potential to increase significantly ozone production and it may be useful as an effective means for removing pollutant gases.

The effects of discharge gases in the voltage transfer curve of ac-PDP (ac-PDP의 전압전달특성에 미치는 방전가스의 영향)

  • Son, J.B.;Lee, S.H.;Kim, D.H.;Kim, Y.D.;Cho, J.S.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2233-2235
    • /
    • 1999
  • The ac plasma display panel(PDP) is a flat light-emitting gas discharge device. Discharge gases directly take effects to the discharge phenomena of ac PDP. Therefore it is necessary to understand the characteristics of the discharge gases. In this paper, we have studied the effects of discharge gases by voltage transfer curves which show the discharge characteristics of ac PDP and the change of the effective wall capacitance during a discharge which depends on lateral spreading of charge distribution and the strength of discharge. As gas pressure increases, memory margins increases. and the firing voltage of a mixed gas is lower than that of a single gas such as He gas. The minimum sustain voltage and the maximum sustain voltage or firing voltage increases with decrease in the frequency. The effective wall capacitance increases as the discharge strength that is, the gap voltage between discharge electrodes increases.

  • PDF

A Study on the Channel forming Discharge Estimation and the Hydraulic Geometry Characteristics of the Alluvial Stream (충적하천의 하도형성유량 산정과 수리기하특성에 관한 연구)

  • Lee, Hee-Chul;Lee, Eun-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.5
    • /
    • pp.823-838
    • /
    • 2003
  • For many rivers and streams, it has been observed that a single representative discharge may be used to determine the hydraulic geometry of a stable channel. This representative channel forming discharge has been given several names by different researchers, including bankfull, specified recurrence interval, and effective discharge. Therefore, The purpose of this study is to estimate channel forming discharge for study areas using the hydrological characteristic parameters and recording data, and to determine the hydraulic geometry relationships for the relating bankfull dimensions to bankfull discharge. In the Munmak and Seomyun gauging stations, the estimated bankfull discharges are found to have a return period of 1.8 and 1.5 years on the maximum annual series, respectively. The estimated effective discharges at those stations are largely different from bankfull discharges. The hydraulic geometry relationships between bankfull discharge and bankfull width, bankfull depth, velocity, bed slope are established. But the statistical parameters, such as R2, are calculated lower.

Effective Method of determining the Water Discharge of a Pondage I considering Operating Constraint (수력기 운전제약을 고려한 저수지식댐의 효과적인 사용수량 결정에 관한 연구)

  • Jeon, Dong-Hoon;Nam, Jae-Hyun;Park, Si-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.784-786
    • /
    • 1997
  • In this Paper, the effective method of determining the water discharge of a pondage hydro-unit for hydro dispatch is proposed. The water discharge of a pondage hydro-unit can be determined subtracting the spillage discharge from summation of the inflow and the pondage according to variation of the water level of the reservoir. Proposed method calculates the inflow using the duration curve, the water level from initial level on January 1, and the spillage discharge from the water discharge.

  • PDF