• 제목/요약/키워드: Effective charge number

검색결과 66건 처리시간 0.023초

SnPb와 무연 플립칩 솔더의 유효전하수와 임계전류밀도 (Effective Charge Number and Critical Current Density in Eutetic SnPb and Pb Free Flip Chip Solder Bumps)

  • 채광표
    • Journal of Welding and Joining
    • /
    • 제23권5호
    • /
    • pp.49-54
    • /
    • 2005
  • The effective charge number and the critical current density of electromigration in eutetic SnPb and Pb Free $(SnAg_{3.8}Cu_{0.7)$ flip chip solder bumps are studied. The effective charge number of electromigration in eutectic SnPb solder is obtained as 34 and the critical current density is $j=0.169{\times}({\delta}_{\sigma}/{\delta}_x})\;A/cm^2,\;where\;({\delta}_{\sigma}/{\delta}_x})$ is the electromigration-induced compressive stress gradient along the length of the line. While the effect of electromigration in Pb free solder is much smaller than that in eutectic SnPb, the product of diffusivity and effective charge number $DZ^{\ast}$ has been assumed as $6.62{\times}10^{-11}$. The critical length for electromigration are also discussed.

LPG-DME 성층혼합 압축착화 엔진 (LPG-DME Stratified Charge Compression Ignition Engine)

  • 배충식;염기태
    • 대한기계학회논문집B
    • /
    • 제31권8호
    • /
    • pp.672-679
    • /
    • 2007
  • The combustion characteristics of a liquefied petroleum gas-di-methyl ether (LPG-DME) compression ignition engine was investigated under homogeneous charge and stratified charge conditions. LPG was used as the main fuel and injected into the combustion chamber directly. DME was used as an ignition promoter and injected into the intake port. Different LPG injection timings were tested to verify the combustion characteristics of the LPG-DME compression ignition engine. The combustion was divided into three region which are homogeneous charge, stratified charge, and diffusion flame region according to the injection timing of LPG. The hydrocarbon emission of stratified charge combustion was lower than that of homogeneous charge combustion. However, the carbon monoxide and nitrogen oxide emission of stratified charge combustion were slightly higher than those of the homogeneous charge region. The indicated mean effective pressure was reduced at stratified charge region, while it was almost same level as the homogeneous charge combustion region at diffusion combustion region. The start of combustion timing of the stratified charge combustion and diffusion combustion region were advanced compared to the homogeneous charge combustion. It attributed to the higher cetane number and mixture temperature distribution which locally stratified. However, the knock intensity was varied as the homogeneity of charge was increased.

Kraft Bagasse Pulp Delignification with Dimethyldioxirane

  • Yousef, Hussein-Abou
    • 펄프종이기술
    • /
    • 제33권5호
    • /
    • pp.25-29
    • /
    • 2001
  • Dimethyldioxirane (DMD), which is a source of active oxygen, is effective agent that can be used in chemical pulp bleaching. In this study, delignification of kraft bagasse pulp has been carried out by using DMD. The effect of the applied charge of DMD (as active oxygen) and pH of the delignification medium were studied. The optimum conditions of the applied DMD charge and pH of the delignification reaction were achieved at pH range from 8~9, 2% of DMD (as active oxygen) and the rest of delignification reaction conditions were $25^{\circ}C$, 60 min, and 12% pulp consistency. The development of brightness per unit kappa number removal (ΔBrightness/ Δ Kappa number) has highest value at the optimum condition. The study showed that the reactivity of kraft bagasse pulp be enhanced to wards alkaline hydrogen peroxide bleaching by pulp treatment with DMD.

  • PDF

신마산 345kV 전력소 모선하의 3차원 불평등 전계분포 해석 (Three-Dimensional Electric Field Calculation around the 345kV Sinmasan Substation Busbars)

  • 명성호;이병윤;한인수;박종근;민석원;김응식;이기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1804-1806
    • /
    • 1996
  • For the rather complicated and time-consuming three-dimensional electric field calculation in the vicinity of substations, this paper proposes a numerical calculation method based on charge simulation method(CSM). In order to represent non-uniform charge distribution on an electrode better, it is subdivided into small segments with linear charge density. Non-uniform arrangement of subdivided segments makes it possible to obtain high accuracy with a small number of variables. As for the arrangement of subdivided segments, effective formulars were derived from multiple regression analysis of many simulations. These formulars make the arrangement of segments fast and effective. The proposed method is applied to the electric field calculation around the 345kV Sinmasan Substation busbars and the distribution of calculated electric fields is compared with that of the measured electric fields.

  • PDF

An Analysis of Actual States of the Nursing Grade of Medical Institutions

  • Park, Hyun-Suk
    • 한국임상보건과학회지
    • /
    • 제2권3호
    • /
    • pp.158-166
    • /
    • 2014
  • Purpose. This study pursued the way for the effective application of the differentiated charge (Nursing grading system) by the nursing manpower which is performed for the nursing service quality improvement to the in-patients in Korea and the minimum employment problem solution of nurses. Methods. For this matter, the status of the nursing grade for 1,452 hospitals (44 high class general hospitals, 259 general hospitals, 265 hospitals, 59 oriental medicine hospitals and 825 recuperation hospitals) was identified which were registered in the Health Insurance Review and Assessment Service in March 2011 status quo. Results. In the most nursing grade by the kind of medical institutions, 70.5% of the nurses were third-graded in upper general hospitals, 38.1% were sixth graded in general hospitals, 62.7% were seventh-graded in oriental medicine hospitals and 40.4% were first-graded in recuperation hospitals. In the nursing grade by the scale of hospitals (in terms of the number of beds), there was a significant difference in general hospitals, but there was no significant difference between oriental medicine hospitals and recuperation hospitals. In the nursing grade by the location of hospitals and the foundation type of hospitals, there was a significant difference between general hospitals and recuperation hospitals. Conclusion. For the effectiveness of applying differentiated nursing fees by the number of nurses, it seems necessary to consider adjusting the present differentiated inpatient-charge system for the better so that small and medium-sized hospitals may induce more nurses.

Survey of Status for Ageing Population, Charge Organizations and Polices in UK

  • Kee, Dohyung
    • 대한인간공학회지
    • /
    • 제33권5호
    • /
    • pp.387-394
    • /
    • 2014
  • Objective: The purpose of this study is to survey trend and the real state of ageing population in UK, and its charge organizations, relevant policies and studies. Background: As in other countries, UK population is ageing and people aged 65 or over account for about 17% of population in UK. Considering this ageing population, there are varying basic studies and policies for older people in UK. Method: First, the author consulted ageing and its policies in UK with some faculties in an UK university. Next, based on the results of consultation, wide literature survey was conducted, which includes papers in relevant academic journals, publications and website surfing. Results: A number of basic studies for surveying status and characteristics of older people as well as simple population trend for them have been conducted in UK. Healthcare services are free for all UK residents, and varying social care services including equipment, home and residential cares, financial support, etc., are provided by local governments. Cost of social cares is means-tested and is not free for everyone. There are a number of governmental or non-profit organizations dedicated to help older people access social care services or to financially fund research projects older people. Conclusion: There are more basic studies, and healthcare and social care services for older people in UK, compared to Korea. Application: It would be useful as basic data for establishing effective polices for old people in Korea.

수중 방전과 공간전하제어에 의한 효과적인 산화성물질 발생특성 (Effective Oxidant Generation and Ion Precipitation Characteristics of Electrolyzing Cell by Discharge and Space Charge Control)

  • 김진규;이대희;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.9-12
    • /
    • 2000
  • A new type electrolyzing cell with slits on parallel plate electrodes and wire-to-cylinder type electrode system has been proposed instead of the conventional parallel plate type. An investigation was carried out on the effect of the number and size of slits on ion precipitation and oxidant generation characteristics, evidenced by eliminated space charge limiting action and by elevated electric fields in active interelectrode spacing. And it is also studied on the effect of the diameter of wire electrode to ion precipitation and oxidant generation characteristics. With electrode with 48 slits, very oxidants generation water of 3.1 [ppmm] and 19.0 [ppmm] in positive electrode side were obtained with tap water and 0.1 [wt%] NaCl dissolved tap waterfed. In addition, with wire-to-cylinder type electrode system, it is found that oxidant contained water of 0.48 [ppmm] and 5.46 [ppmm] in positive electrode side were obtained with tap water and 0.1 [wt%] NaCl dissolved tap water fed for the case of discharge electrode diameter of 0.5 [$mm{\phi}$]. Consequently, very high ion precipitation and dense oxidant generation characteristics can be realized by having slits on the electrodes of conventional cell as these slits increase the electric fields and decrease the space charge limiting actions in interelectrode spacing.

  • PDF

765 kV 교류 2회선 송전선 하의 인체 및 자동차에 유도되는 전압, 전류 계산 (Calculation of the induced voltage and current for a human and a car close to 765 kV AC double circuit transmission line)

  • 민석원;김응식;명성호;이병윤;박종근
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.301-309
    • /
    • 1996
  • This paper estimates the electric field effect near 765[kV] AC double transmission line with numerical data. The induced voltage and current of a human and car under who kinds of phase arrangement are calculated when each of two objects is insulated or grounded. When the calculated results of the low-reactance and superposition phase arrangement are compared, it is proved that the induced voltage and current of the former are about 30 [%] smaller than that of the latter. The induced current of a human and car are less than 0.5[mA] which is about 10[%] less than that of the American National Standard Code. Also the induced voltage and current of dead lines by other live lines are calculated. Finally the effective number and position of shield wires to reduce the field in ground level are considered. charge simulation method and surface charge method are used to simulate the 2 or 3 dimensional transmission line model respectively.

  • PDF

직렬 커패시터 D/A 변환기를 갖는 저전력 축차 비교형 A/D 변환기 (Low Power SAR ADC with Series Capacitor DAC)

  • 이정현;진유린;조성익
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.90-97
    • /
    • 2019
  • The charge redistribution digital-to-analog converter(CR-DAC) is often used for successive approximation register analog-to-digital converter(SAR ADC) that requiring low power consumption and small circuit area. However, CR-DAC is required 2 to the power of N unit capacitors to generate reference voltage for successive approximation of the N-bit SAR ADC, and many unit capacitors occupy large circuit area and consume more power. In order to improve this problem, this paper proposes SAR ADC using series capacitor DAC. The series capacitor DAC is required 2(1+N) unit capacitors to generate reference voltage for successive approximation and charges only two capacitors of the reference generation block. Because of these structural characteristics, the SAR ADC using series capacitor DAC can reduce the power consumption and circuit area. Proposed SAR ADC was designed in CMOS 180nm process, and at 1.8V supply voltage and 500kS/s sampling rate, proposed 6-bit SAR ADC have signal-to-noise and distortion ratio(SNDR) of 36.49dB, effective number of bits(ENOB) of 5.77-bit, power consumption of 294uW.

A New Photovoltaic System Architecture of Module-Integrated Converter with a Single-sourced Asymmetric Multilevel Inverter Using a Cost-effective Single-ended Pre-regulator

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.222-231
    • /
    • 2017
  • In this paper, a new architecture for a cost-effective power conditioning systems (PCS) using a single-sourced asymmetric cascaded H-bridge multilevel inverter (MLI) for photovoltaic (PV) applications is proposed. The asymmetric MLI topology has a reduced number of parts compared to the symmetrical type for the same number of voltage level. However, the modulation index threshold related to the drop in the number of levels of the inverter output is higher than that of the symmetrical MLI. This problem results in a modulation index limitation which is relatively higher than that of the symmetrical MLI. Hence, an extra voltage pre-regulator becomes a necessary component in the PCS under a wide operating bias variation. In addition to pre-stage voltage regulation for the constant MLI dc-links, another auxiliary pre-regulator should provide isolation and voltage balance among the multiple H-bridge cells in the asymmetrical MLI as well as the symmetrical ones. The proposed PCS uses a single-ended DC-DC converter topology with a coupled inductor and charge-pump circuit to satisfy all of the aforementioned requirements. Since the proposed integrated-type voltage pre-regulator circuit uses only a single MOSFET switch and a single magnetic component, the size and cost of the PCS is an optimal trade-off. In addition, the voltage balance between the separate H-bridge cells is automatically maintained by the number of turns in the coupled inductor transformer regardless of the duty cycle, which eliminates the need for an extra voltage regulator for the auxiliary H-bridge in MLIs. The voltage balance is also maintained under the discontinuous conduction mode (DCM). Thus, the PCS is also operational during light load conditions. The proposed architecture can apply the module-integrated converter (MIC) concept to perform distributed MPPT. The proposed architecture is analyzed and verified for a 7-level asymmetric MLI, using simulation results and a hardware implementation.