• 제목/요약/키워드: Effective Thickness

검색결과 1,955건 처리시간 0.032초

Muscle Fiber, Connective Tissue and Meat Quality Characteristics of Pork from Low Birth Weight Pigs as Affected by Diet-Induced Increased Fat Absorption and Preferential Muscle Marbling

  • Bimol C. Roy;Patience Coleman;Meghan Markowsky;Kun Wang;Yongbo She;Caroline Richard;Spencer D. Proctor;Heather L. Bruce
    • 한국축산식품학회지
    • /
    • 제44권1호
    • /
    • pp.51-73
    • /
    • 2024
  • This study investigated how birth weight differences in piglets affected carcass and muscle fiber properties as well as meat quality at slaughter. Within litters, piglets were grouped according to their birth weight as either normal (NBW; 1.62-1.73 kg) or low (LBW; 1.18-1.29 kg). At 5 weeks of age, NBW piglets were randomly transitioned to control (C) or isocaloric high fat diets derived from non-dairy (HF), while LBW piglets were randomly transitioned to high fat diets derived from non-dairy (HF) or dairy sources (HFHD). Piglets were reared in individual pens under standardized housing and feeding conditions. Live weight was recorded weekly, and pigs were slaughtered at 12 weeks of age. Hot carcass weights, dressing percentages, lean meat yield, and primal cut proportions were determined. The m. longissimus thoracis was collected from the right side of the carcass for measurement of physical and chemical properties of meat and muscle fiber characteristics. Results indicated that LBW pigs compensated for their live weight compared to NBW pigs at 6 weeks of age. The mean muscle fiber diameter of LBW-HFHD group is significantly higher than NBW-C and NBW-HF group, and the type I muscle fiber diameter is significantly higher than NBW-C group. Dairy fat inclusion in LBW pig diet reduced carcass back fat thickness. This increased the calculated lean meat yield to be comparable to that of NBW pigs fed a commercial diet. Incorporating dairy-sourced high-fat into LBW pigs' diets appears to be an effective strategy for producing carcasses equivalent to NBW pigs.

초고강도(130MPa) 콘크리트의 현장적용성 평가에 관한 실험 (Field Applicability Evaluation Experiment for Ultra-high Strength (130MPa) Concrete)

  • 조춘환
    • 한국재난정보학회 논문집
    • /
    • 제20권1호
    • /
    • pp.20-31
    • /
    • 2024
  • 연구목적: 고강도 콘크리트 연구개발은 건축물의 고층화를 가능케 하고, 단면 축소로 구조물 자중이 경감되어 보와 슬래브 두께를 얇게 함으로 보다 많은 층수를 축조할 수 있었으며, 넓은 유효공간이 확보되고, 기초 저면 지정에 사용된 자재 및 철근과 콘크리트 양을 절감하는 효과를 가져올 수 있다. 연구방법: 현장시공 및 품질측면에서는 낮은 물결합재비 배합를 연구하므로 건조수축 발생 저감 효과를 확인할 수 있고, 콘크리트 표면의 블리딩 최소화 연구를 통하여 그 효과를 검증할 수 있다. 연구결과:고성능감수제 사용에 의한 유동성 증진으로 자체 충전성이 높아 현장 시공 용이성을 확인하고, 콘크리트의 조기 강도 발현으로 거푸집 탈형 시간을 단축시킬 수 있는 장점을 확인하였다. 이러한 실험결과 자료는 초고층 건축물에서는 설계기준강도 100MPa급 이상의 초고강도콘크리트의 현장 적용이 확대될 수 있다. 본 연구를 통하여 국내에서도 120층 이상의 초고층 건축물 현장 적용성이 고려된 130MPa급 이상의 초고강도 콘크리트를 현장에서 실제 적용 가능성 여부를 실험, 평가하였다. 결론:본 연구에서는 초고강도의 현장적용 가능성을 확인하기 위하여 여러 가지 방법의 실내기초 실험으로 연구되어진 최적의 배합비를 찾아서 모의부재 예비 실험 후 실물크기와 유사한 모의부재에 130MPa 초고강도콘크리트를 레미콘 공장에서 생산하여 현장 펌프 압송 타설하고, 콘크리트의 유동성 및 강도 발현과 수화열에 관하여 현장 적용성을 실험한 연구다.

충격 반향 신호 모니터링을 통한 철근 부식 진전에 따른 콘크리트 상태 평가 (Progressive Evaluation of Concrete Deterioration Caused by Chloride-Induced Steel Corrosion Using Impact-Echo Testing)

  • 피타젱 리즈키;줄피크산 아흐마드 무크티;기성훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권3호
    • /
    • pp.37-46
    • /
    • 2024
  • 본 연구에서는 충격반향법(IE)을 활용하여 철근 부식 진전에 따른 콘크리트 손상 상태를 모니터링하였다. 길이 1500 mm, 폭 400 mm, 두께 200 mm를 갖는 세 개의 철근 콘크리트 시험체를 제작하였다. 각 시험체는 보통 포틀랜드 시멘트, 고로 슬래그 미분말, 플라이 애쉬를 혼합한 세 가지 콘크리트 배합을 활용하여 제작하여, 결합재 특성에 따른 손상특성을 관찰하였다. 콘크리트 내 철근 부식은 3% NaCl 용액에서 35일 주기의 습윤 및 건조 포화 과정을 거친 후 0.5 A 전류를 인가하여 가속화되었다. 전류인가 전 습윤-건조반복(철근부식 환경조성 또는 잠재기)단계에서 수집된 초기 IE 데이터는 건조상태가 IE 신호에 미치는 영향이 크기 않음을 보여주었다. 전류를 인가한 후에는 인가 시간 증가에 따라 IE 탁월주파수와 콘크리트 P파속도의 점진적인 감소 특성을 관찰할 수 있었다. 이러한 실험결과는 IE 데이터 모니터링으로 철근 부식으로 인한 콘크리트의 점진적 손상의 주요 특성(내부 손상 개시 및 전파 속도 등)을 포착할 수 있음을 보여준다. 따라서, 철근 부식에 따른 콘크리트의 점진적 손상의 평가 및 예측에 IE 모니터링이 효과적으로 활용될 수 있을 것으로 기대한다.

De-icing 횟수에 따른 폴리우레탄 탑코트의 손상 조사 (Investigation of Damage to Polyurethane Topcoat Based on De-icing Cycles)

  • 이동현;박종만;임형미;권동준
    • Composites Research
    • /
    • 제37권3호
    • /
    • pp.204-208
    • /
    • 2024
  • 제/방빙액은 항공기 결빙 제거에 필수적으로 사용된다. 제/방빙액은 유기용제를 희석시켜 제조되고, 화학적으로 결빙을 제거할 때 탑코트 표면에서 손상이 발생된다. 본 연구에서는 글리콜 계열의 제/방빙액을 사용하여 결빙을 제거하였고, 결빙 제거과정에서 발생된 탑코트의 손상에 대하여 관찰하였다. USB 현미경을 이용하여 결빙의 생성 및 성장과정을 관찰하였고, 공초점 현미경으로 제/방빙액 처리에 따른 표면 형상을 관찰하였다. 또한 코팅 두께 측정과 푸리에 변환 적외선 분광분석을 통하여 표면의 물리적 및 화학적 변화를 조사하였다. 제/방빙액의 반복적인 처리는 결빙의 생성 속도 감소시키고, 결빙의 성장 속도 증가시키는 효과를 보였다. 제/방빙액 처리 과정에서 가압 공정 시 발생되는 손상과 에틸렌 글리콜에 의하여 폴리우레탄 탑코트의 표면 손상이 발견되었다. 탑코트의 손상에 대한 변화를 분석한 결과 화학적 변화는 확인되지 않았지만, 표면의 균일성은 감소하고, 표면에 균열이나 굴곡이 형성되는 물리적 손상이 관찰되었다. 제/방빙액은 결빙 제거에 효과적이나 표면 손상을 일으키는 것을 확인하였다.

Theoretical analysis of erosion degradation and safety assessment of submarine shield tunnel segment based on ion erosion

  • Xiaohan Zhou;Yangyang Yang;Zhongping Yang;Sijin Liu;Hao Wang;Weifeng Zhou
    • Geomechanics and Engineering
    • /
    • 제37권6호
    • /
    • pp.599-614
    • /
    • 2024
  • To evaluate the safety status of deteriorated segments in a submarine shield tunnel during its service life, a seepage model was established based on a cross-sea shield tunnel project. This model was used to study the migration patterns of erosive ions within the shield segments. Based on these laws, the degree of deterioration of the segments was determined. Using the derived analytical solution, the internal forces within the segments were calculated. Lastly, by applying the formula for calculating safety factors, the variation trends in the safety factors of segments with different degrees of deterioration were obtained. The findings demonstrate that corrosive seawater presents the evolution characteristics of continuous seepage from the outside to the inside of the tunnel. The nearby seepage field shows locally concentrated characteristics when there is leakage at the joint, which causes the seepage field's depth and scope to significantly increase. The chlorine ion content decreases gradually with the increase of the distance from the outer surface of the tunnel. The penetration of erosion ions in the segment is facilitated by the presence of water pressure. The ion content of the entire ring segment lining structure is related in the following order: vault < haunch < springing. The difference in the segment's rate of increase in chlorine ion content decreases as service time increases. Based on the analytical solution calculation, the segment's safety factor drops more when the joint leaks than when its intact, and the change rate between the two states exhibits a general downward trend. The safety factor shows a similar change rule at different water depths and continuously decreases at the same segment position as the water depth increases. The three phases of "sudden drop-rise-stability" are represented by a "spoon-shaped" change rule on the safety factor's change curve. The issue of the poor applicability of indicators in earlier studies is resolved by the analytical solution, which only requires determining the loss degree of the segment lining's effective bearing thickness to calculate the safety factor of any cross-section of the shield tunnel. The analytical solution's computation results, however, have some safety margins and are cautious. The process of establishing the evaluation model indicates that the secondary lining made of molded concrete can also have its safety status assessed using the analytical solution. It is very important for the safe operation of the tunnel and the safety of people's property and has a wide range of applications.

흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용 (Clinical Application of Stent-graft in Thoracic Aortic Diseases)

  • 김경환;이철;장지민;정진욱;안혁;박재형
    • Journal of Chest Surgery
    • /
    • 제34권9호
    • /
    • pp.698-703
    • /
    • 2001
  • 배경: 하행 흉부대동맥류를 포함한 대동맥 질환을 가진 환자들에서 히생한 대동맥내 스텐트-그라프트 삽입술의 치료효과와 추적성적 및, 대상 환자들의 임상적 특징을 통해 치료방법으로서의 적응과 역할을 알아보았다. 대상 및 방법: 1995년 이후 모두 8명의 환자에서 진단방사선과와 협진으로 스텐트-그라프트 삽입술을 시행하였으며, 시술 전 진단으로는 외상성 대동맥 파열이 3례, 동맥경화증성 대동맥류 3례, 흉부가성대동맥류 파열 1례, 매독성 대동맥염에 의한 흉복무대동맥류가 1례였다. 시술은 혈관조영실에서 혈관조영을 하면서 시행하였고, 전신마취가 3례, 국소마취가 3례였고, 2례에서 경막외 마취하에 시술하였으며, 사용한 스텐트-그라프트는 0.35mm 굵기의 스테인레스 강철사를 지그재그 형태로 구부려 만든 스텐트를 서로 연결하고 인조혈과(Dacton)을 입힌 후 봉합한 것으로 제조회사에 의뢰하여 자체제작 하였다. 결과: 시술받은 환자의 전례에서 스텐트-그라프트 삽입시 기술적 어려움은 없었으며, 스텐트-그라프트 삽입후 4일에서 7일 사이에 시행했던 추적검사(4례)에서 스텐트-그라프트 주위부 누출이나 당초 목표했던 위이에서의 이탈은 없었다. 1례의 외사성 대동맥 파열이 었었던 환자가 시술 후 13일째 급성호흡곤란증후군 및 다장기부전으로 사망하였고, 매독성 대동맥염이 있었던 흉복부 대동맥류 환자가 시술 후 6일째 상행대동맥 및 대동맥궁에 대한 수술을 시행받고 술후 22일째 문합부위 파열로 사망하였다. 결론: 대동맥내 스텐트-그라프트를 이용한 흉복부 대동맥 질환의 치료는 수술에 따른 이환률 및 사망률을 고려할 때 특히 다장기부전으로 수술이 어려운 경우 또는 수술 후 합병증의 발생이 강력히 우려되는 경우에 안전하게 시행할 수 있는 치료의 한 방편으로서 의미를 가진다고 사료된다.행성 이하선염과 파라인플루엔자 바이러스는 외피가 있는 170-180nm 이었다.TEX>$\pm$0.10(100분), 0.46$\pm$0.11(120분), 0.52$\pm$0.15(심폐기 재가동 30분), 0.62$\pm$0.15(60분), 0.76$\pm$0.17(심폐기이탈 30분), 0.81$\pm$0.20(60분), 0.84$\pm$0.23(90분) and 0.94$\pm$0.33(120분)를 보였고 이는 역행성 뇌관류 전에 비해 유의하게 증가된 소견이었다(p<0.05). 뇌신피질, 기저핵, 해마에서 전자현미경 조직 소견을 관찰하였으며 마이토콘드리아의 부종을 관찰할 수 있었다. 결론 : 역행성 뇌관류 120분 후에 S100 베타 단백의 유의한 증가를 관찰할 수 있었으며 뇌조직 손상과의 관련성은 좀 더 연구되어야 할 부분으로 생각된다. 장기 생존 모델을 통한 재평가가 필요하다고 사료되며 심폐바이패스 시행 등의 교란 인자도 고려해야 할 것이다.비해 Progenitor II의 형질전환 효율이 현저히 떨어졌다. L. acidophilus HY7008과 HY7001은 두 기기 모두 형질전환이 이루어졌으나, L. acidophilus WEISBY와 NCFM은 Progeni-tor II에서 전이가 일어나지 않았으며, Gene Pulser에서 전이균주를 얻어 두 electroporator간에 형질전환 효율의 차이를 보였다. 11. L. casei 102S에 pLZ12를 electroporation시 낮은 전압에서 형질전환 효율이 비교적 좋았으며, 배양 시기를 달리하여 전이시켰을 때 대수생장 말기의 세포가 형질전환 효율이 좋았다. 12.

  • PDF

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2000년도 추계학술발표회 초록집
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

저농도 액비처리에 따른 밤나무 생장 및 결실특성과 과실품질 (Growth and Fruiting Characteristics, and Nut Qualities of Castanea crenata by Low-Concentrated Liquid Fertilizer)

  • 이욱;황석인;김만조;김지혜
    • 한국산림과학회지
    • /
    • 제100권3호
    • /
    • pp.432-440
    • /
    • 2011
  • 밤나무의 수고와 근원경은 액비처리구와 화학비료처리구에서 가장 많은 생장량을 나타냈으며 수관폭 생장량은 동-서방향과 남-북방향에서 각각 액비처리구와 화학비료처리구에서 우수하였다. 결과지의 총 길이와 착구부~정단부의 길이생장은 액비처리구에서 가장 우수하였으며 기부~착구부의 길이는 액비처리구와 화학비료처리구에서 동일하게 가장 길게 생장하였다. 결과지의 기부직경과 착구부의 상하부직경은 모두 액비처리구에서 가장 두껍게 생장하였다. 본 연구의 5개의 생장지수(결과지발생지수, 길이생장지수, 착구부상하직경비율, 직경생장지수, 굵기지수)에서 길이생장지수만이 액비처리구에서 가장 높고 나머지 모든 지수는 화학비료처리구에서 가장 높았다. 결과모지당 가지발생수와 소약지 개수는 무처리구와 액비처리구에서 많았으며 처리간 유사한 경향을 보였다. 결과모지당 결과지수는 화학비료처리구와 유기질비료처리구에서 많았으며, 결과지당 착구수는 유기질비료처리구와 액비처리구에서 많았다. 과실의 중량과 수량을 기준으로 한 상품화 비율은 무처리구(87.5%)와 화학비료처리구(84.6%)에서 높았으나 액비처리구의 상품화 비율은 각각 84.3%와 82.7%로 평균 수준이었다. 평균입중과 총착구수는 각각 액비처리구와 화학비료처리구로 가장 우수하였다. 함과수는 처리 간 차이는 없었으며 본당수확량은 화학비료처리구(8.2 kg)와 액비처리구(8.0 kg)에서 다수확성을 보였으나 처리간 통계적으로 유의한 차이는 없었다. 과실의 중량과 수량을 기준으로 등급을 구분한 결과, 액비처리구에서 대립 이상의 비율이 각각 43.5%와 34.3%로 가장 높아 액비처리에서 고부가가치의 고품질 밤이 가장 많이 생산되었다.

유방전절제술 후 방사선치료를 위한 조직보상체 개발 및 3차원 치료계획을 통한 유용성 분석 (The Benefit of Individualized Custom Bolus in the Postmastectomy Radiation Therapy : Numerical Analysis with 3-D Treatment Planning)

  • 조재호;조광환;금기창;한영이;김용배;추성실;서창옥
    • Radiation Oncology Journal
    • /
    • 제21권1호
    • /
    • pp.82-93
    • /
    • 2003
  • 목적 : 유방암의 수술 후 방사선조사 시 폐나 심장 등 정상 증기에 대한 합병증을 줄이고자 흉벽에 대한 전자선 치료 시 조사야 내 전체 흉벽 두께를 균일하도록 보상할 수 있는 개별화된 조직보상체를 제작하였으며, 3차원 입체조형치료계획을 통하여 유용성을 평가하고자 하였다. 대상 및 방법 :유방전절제술 후 방사선치료를 받는 10명의 환자를 대상으로 하였다 우측 유방암 환자가 3명, 좌측유방암 환자가 7명이었다. 모든 환자는 조사야를 결정하기 위한 모의치료를 시행한 후 치료계획용 컴퓨터단층촬영을 하였으며, 이를 바탕으로 1 cm$^{2}$ 간격으로 흉벽 두께를 세밀히 측정하였다. 이후 주로 내유방림프절 근방인 가장 두꺼운 흉벽 부위를 기준으로 그 곳의 전방 흉막면에 80% 선량이 조사될 수 있는 방사선에너지를 설정하고, 이 부위를 기준으로 보다 얇은 흉벽을 보상하기 위한 개별화된 조직보상체를 제작하였으며, 제작된 조직보상체를 적용하여 다시 치료계획용 컴퓨터단층촬영을 시행하였다. 이후 각 환자의 영상자료를 이용하여 3차원 치료계획용 프로그램으로 설계하였다. 매 환자에서 조직보상체 적용 전후로 등선량곡선 분포 및 선량체적히스토그램을 비교하였고, 정상조직합병증발생률(normal tissue complication probability, NTCP)의 변화 및 기타 선량통계값도 분석 비교하였다. 결과 : 조직보상체를 적용하였을 때 모든 예에서 처방선량의 80% 등선량곡선의 깊이가 흉벽 두께와 거의 일치하였다. 조직보상체를 사용하지 않았을 때는 90% 이상의 등선량 곡선이 전방 흉막면을 지나 폐 실질 부위에 깊이 걸쳐 있는 경우가 많았으며, 특히 좌측 유방암의 경우에는 심장에도 불필요하게 높은 선량이 조사됨을 관찰할 수 있었다. 선량체적히스토그램을 조직보상체 적용 전후로 동측 폐, 반대측 폐 및 심장에 대하여 각각 비교하였는데 모든 예에서 조직보상체를 사용하였을 때 동측 폐의 선량체적히스토그램이 크게 향상된 소견을 보였으만 심장의 경우 좌측 유방암 환자에서 특히 두드러진 향상을 보였다. 동측 페의 경우 조직보상체를 적용하지 않았을 때 평균NTCP 값이 80.2${\pm}$3.43%이고, 조직보상체를 사용한 경우에는 평균 NTCP 값이 47.7${\pm}$4.61%로 개별화된 조직보상체의 사용으로 24.5~40.5%의 정상조직합병증발생률을 줄일 수 있었다. 동측 폐와 심장에 대해서 평균 선량, V$_{50}$ (처방선량 50% 이상의 선량이 조사되는 체적의 백분율), V$_{95}$ (처방선량 95% 이상의 선량이 조사되는 체적의 백분율), 최대 선량, 최소 선량 등을 구하여 보았을 때 평균 선량, V$_{50}$, V$_{95}$은 조직보상체 적용 전후에 두드러진 변화를 보였으나 최대선량 및 최소 선량값은 별다른 차이를 보이지 않았다. 결론 : 조직보상체를 적용하였을 때 적용하지 않은 경우에 비해 등선량곡선분포, 선량체적히스토그램, Lymankutcher 모델에 의한 정상조직합병증발생률 및 기타 선량통계값 등 모든 면에 있어서 우월성을 확인할 수 있었다. 향후 이러한 결과가 임상에서 실질적인 합병증 발생률 감소와 잘 연계되는지 계속적인 추적관찰 및 연구가 필요할것으로 생각된다.

고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐 (Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy)

  • 추성실;서창옥;김귀언
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2002
  • 의료용 선형가속기에서 발생되는 고 에너지 광자선은 콜리메이터에 의하여 누출되며 치료두부(head), 콜리메이터, 환자를 포함한 치료실내의 모든 벽과 구성 물질들에 의하여 많은 산란선이 발생된다. 방사선치료는 종양에 따라서 최소한 40 Gy에서 80 Gy까지 조사되기 때문에 주위건강조직 특히 생식가능한 사람에 대한 생식선의 피폭선량을 평가하여야하며 종양치료에 영향을 주지 않은 범위에서 가능한 방법을 동원하여 피폭선량을 줄여야한다. 방사선 안전관리등의 기술기준에 관한 규칙(과학기술부령 제17호) 제3절 의료분야의 특별기준, 제44조(진료환자의 방사선 피폭)에 의하면 진료를 위한 환자 피폭선량을 합리적으로 달성 가능한 최소의 수준으로 유지하기 위한 절차를 구비하여야 하며 과학기술부 장관은 이에 준하는 의료시설 및 장비취급의 기술기준을 정하고 고시하여야한다고 명시 되어있다. 고 에너지방사선은 악성종양환자들의 치료성과를 향상시키는 동시에 치료후 방사선에 의한 만성효과가 발생 될 수 있기 때문에 주선속의 다양한 산란선과 누출선의 선질변화와 선량을 측정하고 생식선과 같은 주요장기를 산란선으로부터 차폐할 수 있는 기구를 제작 사용함으로서 방사선 피폭선량을 최대한으로 감소시킬 수 있었다. 고 에너지 방사선은 의료용 선형가속기(CLINAC 2100C/D. 2100C. 600C)에서 발생시킨 4, 6, 10 MV x-ray와 코발트원격치료장치(ALCYON II)의 코발트선원에서 방출되는 1.25 MV의 감마선을 이용하였다. 선량측정은 폴리스틸렌과 인체팬텀(Rando)사용하였으며 측정기는 이온함, TLD 및 필름을 사용하였다. 고 에너지 방사선에 의한 산란선은 장치의 콜리메이터 뿐만 아니라 치료실 벽 인체내부등 모든 방향에서 방사됨으로 납 벽돌에 의한 차폐율측정은 많은 변수를 가졌으며 고환인 경우에는 3면이 모두 차폐되도록 항아리모양으로 제작하였다. 태아인 경우 태아가 위치하고 있는 골반위에 육교모양의 선반을 만들고 그 위에 납 벽돌을 장치하도록 고안하였다. Co-60 감마선, 4 MV x-선, 10 MV x-선에서 발생되는 누출선량과 산란선량에 의한 평균 피폭선량은 조사면 중심으로부터 10, 30, 60cm 거리에서 조사면내 최대선량에 대하여 각각 $10^{-2},\;10^{-3},\;10^{-4}$의 비율로 측정되었으며 거리에 따라 지수함수로 줄어들었다. 흉부에 국한된 종양을 10 MV x-ray, $12{\times}12 cm^2$ 조사면으로 치료하였을 때 자궁에 받는 피폭선량은 0.9 mGy/Gy이며 고환이 받는 피폭선량은 0.6 mGy/Gy 이었으며 체장과 신장은 각각 4.8 mGy/Gy 와 2.5 mGy/Gy이다 10 MV x-선, $14{\times}14cm^2$ 조사면 경계로부터 10 cm 밖에서 납벽돌의 반가층 두께는 약 9.0 mm 이였고 20cm 밖에서는 반가층 두께가 약 6.5 mm로 측정되었다. 복부에 위치한 악성종양을 60 Gy 조사하였을 경우 태아가 위치하고 있는 자궁의 피폭선량은 약 370 mGy이고 이곳을 10 mGy이하가 되도록 차폐하려면 약 6.2 cm두께의 납 벽돌을 자궁위에 장착하여야 하며 골반치료시 고환에 10 mGy이하가 되도록 차폐하려면 약 5 cm 두께의 납 항아리가 요구된다. 고 에너지 고 준위 방사선치료시 고환은 3면을 항아리모양으로 차폐할 수 있어 피폭선량을 상당히 줄일 수 있으며 자궁인 경우 체내에서 산란된 선량의 차폐는 불가능하였다.