• Title/Summary/Keyword: Effective Thickness

Search Result 1,967, Processing Time 0.028 seconds

THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms- (선박소음에 관한 연구 -방음실에 의한 소음제어효과실험-)

  • PARK Jung-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 1976
  • In this study, noise arresting effect of the noise control room from the transmission of surrounding noise was tested when the packing noise control rooms were set up in the test room in which the prerecorded noise from an engine room was reradiated at the same level as the original pressure. The inner space of control room A is $3.389m^3(1.19\times1.19\times2.14m)$ having walls furnished with plywood board 9mm in thickness and noise control room door$(60\times45cm) $ and illumination lamp are placed. In case of the control room B, noise absorption board(10mm fiber board which holds the corntype concavity with diameter of 5mm, depth 5mm, space 15mm) is adhered to the internal ceiling and styrol foam boards(20mm) to the walls. The other struction is same as the control room A. Type C is the same as B except wool board(Glass Fiber, 33mm) on the walls. Type D is same as type A except that the thickness of wall is 12mm and wood pyramid type cone$(5\times5\times13cm)$ is adhered to the ceiling ana walls(Fig. 1). When the recorded noise and vibrated noise were controlled in various levels. The noise pressure which passed through the control rooms was measured by sound level meter(Bruel & Kjar 2205, measuring range 37-140dB). In order to calculate the absorption rate in the control rooms the noise pressure was measured at different distances when the recorded noise pressure was radiated. The followings are the results obtained from the experiment. 1. When the noise pressure of the test room was 60dB, transmission rate of type A was $69.7\%$ and increased $3.3\%$ per 10dB. At the same condition, the rate was $53.9\%$ and increased $4.5\%$ per 10dB in type D. Type D was the most effective in noise arresting of the four and the effect was D,C,B and A in order(Fig.2). 2. When the oscillator sound and vessels noise were radiated in 1,000Hz, at one meter distance to the type A and D, the oscillator sound pressure were 77dB and 73dB, while the vessels noise pressure were 73.3dB and 66.2dB respectivley(Fig.3). 3. Refering to the influence of the frequency to the lower oscillator sound(1,000Hz) pressure, both type C and D were almost same at 140cm but type C was 0.3dB lower than type D at 20cm distance(Fig.4).

  • PDF

Size and Retention of Tongue Bulb for Tongue Retaining Device (혀 유지구의 크기와 유지력 평가)

  • Park, Nam-Seon;Lee, Ki-Ho;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.283-292
    • /
    • 2007
  • In several treatment modalities for snoring and obstructive sleep apnea (OSA), oral appliances mainly including mandibular advancement appliance (MAA) and tongue retaining device (TRD) are recognized as a non-invasive, reversible alternative with favorable results. Tongue bulb is a major component of TRD which prevents the tongue from approaching the posterior wall of the pharynx and can be combined with MAA. Determination of tongue bulb size for the patient is important for therapeutic effect, but frequently needs time-consuming work. For effective fabrication and standardization of tongue bulbs, this study aimed to categorize tongue bulb size for healthy young men and to examine its relation with maximum retention force and with physical parameters including tongue-related variables. 36 non-snoring, asymptomatic young men with normal occlusion were voluntarily participated in this study (mean age: $24.47{\pm}2.58$ years). Experimental procedures consisted of prefabrication of tongue bulb set (20 types with a width of 27-36mm and thickness of 8 and 10 mm), determination of tongue bulb size and the maximum retention force for each subject, and measurement of physical parameters including body mass index (BMI), neck circumference and width, thickness and length of tongue. This study showed that there was significant difference of retention force among the bulb size-related groups both in upright and supine position (p<0.05) and that retention force increased with bulb size. Correlation of tongue bulb size with physical parameters was not clearly verified and there was no significant difference in retention force between upright and supine positions. Based on our results, it can be suggested that retention force relates with tongue bulb size, ultimately with tongue volume. A further study needs to be performed in the patients with snoring and OSA.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Magnetoresistive of (NiFe/CoFe)/Cu/CoFe Spin-Valvec ((NiFe/CoFe)/Cu/CoFe Spin-Valve 박막의 자기저항 특성)

  • 오미영;이선영;이정미;김미양;이장로
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.5
    • /
    • pp.265-273
    • /
    • 1997
  • The MR ratios and the exchange biasing field and interlayer coupling field were investigated in $Ni_{91}Fe_{19}/Co_{90}Fe_{10}/Cu/Co_{90}Fe_{10}/NiO$ spin-valve sandwiches grown on antiferromagnetic NiO films as a function of the NiO thickness, the thickness of Cu and pinning layer $Co_{90}Fe_{10}$. The spin-valve sandwiches were deposited on the Corning glass 7059 by means of the 3-gun dc and 1-gun rf magnetron sputtering at a 5 mtorrpartial Ar pressure and room temperature. The deposition field was 50 Oe. The MR curve was measured by the four-terminal method with applied magnetic soft bilayer [NiFe/CoFe] (90$\AA$) decreased dramatically to less than 10 Oe when the NiFe/CoFe bilayer used an NiFe bilayer thicker that 20$\AA$. So NiFe layer improved the softmagnetic properties in the NiFe/CoFe bilayer. The GMR ratio and the magnetic field sensitivity of the spin-valve film $Ni_{91}Fe_{19}(40{\AA})/Co_{90}Fe_{10}(50{\AA}) /Cu(30{\AA})/Co_{90}Fe_{10}(35{\AA})/NiO(800{\AA})$ was 6.3% and about 0.5 (%/Oe), respectively. The MR ratio had 5.3% below an annealing temperature of 20$0^{\circ}C$ which slowly decreased to 3% above 30$0^{\circ}C$. The large blocking temperature of the spin-valve film was taken (as being) due to the good stability of the NiO films. Thus, the spin-valve films with a free NiFe/CoFe layer clearly had a high large GMR output and showed a effective magnetic field sensitivity for a suitable spin-valve head material.

  • PDF

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Preparation of $SrTiO_3$ Thin Film by RF Magnetron Sputtering and Its Dielectric Properties (RF 마그네트론 스퍼터링법에 의한 $SrTiO_3$박막제조와 유전특성)

  • Kim, Byeong-Gu;Son, Bong-Gyun;Choe, Seung-Cheol
    • Korean Journal of Materials Research
    • /
    • v.5 no.6
    • /
    • pp.754-762
    • /
    • 1995
  • Strontium titanate(SrTiO$_3$) thin film was prepared on Si substrates by RF magnetron sputtering for a high capacitance density required for the next generation of LSTs. The optimum deposition conditions for SrTiO$_3$thin film were investigated by controlling the deposition parameters. The crystallinity of films and the interface reactions between SrTO$_3$film and Si substrate were characterized by XRD and AES respectively. High quality films were obtained by using the mixed gas of Ar and $O_2$for sputtering. The films were deposited at various bias voltages to obtain the optimum conditions for a high quality file. The best crystallinity was obtained at film thickness of 300nm with the sputtering gas of Ar+20% $O_2$and the bias voltage of 100V. The barrier layer of Pt(100nm)/Ti(50nm) was very effective in avoiding the formation of SiO$_2$layer at the interface between SrTiO$_3$film and Si substrate. The capacitor with Au/SrTiO$_3$/Pt/Ti/SiO$_2$/Si structure was prepared to measure the electric and the dielectric properties. The highest capacitance and the lowest leakage current density were obtained by annealing at $600^{\circ}C$ for 2hrs. The typical specific capacitance was 6.4fF/$\textrm{cm}^2$, the relative dielectric constant was 217, and the leakage current density was about 2.0$\times$10$^{-8}$ A/$\textrm{cm}^2$ at the SrTiO$_3$film with the thickness of 300nm.

  • PDF

Volumetrical changes of liver associated with breathing and its impact to normal tissue complication probability (호흡에 따른 간장용적의 변화와 정상조직손상확율에 미치는 영향에 관한 연구)

  • Cho Jung Hee;Kim Joo Ho;Lee Suk;Park Je Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.14-22
    • /
    • 2001
  • Purpose: The aim of this study is to investigate geometrical and volumetrical changes of liver due to breathing and its impact to NTCP. In order to attain better treatment results it should be considered deliberately during planning session. Mehtods and Materials : Seven patients were examined in this study who have done TACE for accurate tumor margin drawing. After contrast media injection, C-T scan data were obtained in supine position during breathing free, inhalation and exhalation, respectively. For all patients C-T scan were done with same scanning parameters- 5 mm index, 5 mm thickness and pitch 1. Based on C-T data we have measured differences of each variables between breathing status such as changes of total and remained liver volumes, GTV, beam path length and superior to inferior shift. NTCP were calculated using Lyman's effective volume DVH reduction scheme and for this NTCP calculation, the V50 was computed from DVH and each m, n value were referred from Burmans data. Results : The measured total tilter volume and the remained liver volume changed between inspiration and expiration about $1.2-7.7\%(mean+2.7\%)$ and $2.5-13.23\%(mean=5.8\%)$ respectively, and these results were statistically significant(p>0.1). The GTV difference in each patient varied widely from $1.17\%\;to\;30.69\%$, but this result was not statistically significant. Depending on the breathing status, the beam path length was changed from 0.5 cm to 1.1 cm with the average of 0.7 cm, and it was statistically significant(p=0.006). The measured superior to inferior shifts were ranged from 0.5 cm to 3.74 cm. The NTCPs were changed relatively small in each patient, but the variation was large between the patients. The mean NTCP difference was $10.5\%$, with the variation ranged from $7\%\;to\;23.5\%$. Conclusion : Variations of liver volume and of beam path length were changed significantly depending on the breathing statues and the range of variation itself was very different between the patients. Since this variance could seriously affect the clinical outcomes of radiation treatments, the breathing of patients need to be accounted when a final treatment planning is derided.

  • PDF

A Study on Physical and Chemical Properties of Vegetation Foundation for Rooftop Greening Using Wood Waste (폐목질 자원을 이용한 옥상녹화용 식생기반재의 물리 및 화학적 특성에 관한 연구)

  • Kim, Dae-Young;Kim, Mi Mi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.79-87
    • /
    • 2008
  • Many researchers have studied on rooftop greening that can be installed in abandoned spaces on a building roof. The most important issue in rooftop greening is the soil weight problem. The light greening materials are needed to solve this problem. Therefore, many alternative materials against the soil were investigated for rooftop greening. In this study, the waste wood chips and the waste paper slurry were evaluated as the lightweight vegetation foundation for rooftop greening. It also has a meaning for recycling of waste materials. The mixture ratio of waste wood chips to waste paper slurry for the board (the foundation of greening) was 60 to 40. The wet strength resin and the sizing agent were additionally added with different amount. After the forming of the board, physical and chemical properties were tested with the variation of wet strength resin and sizing agent. As the result of the test, the board with 15% of wet strength resin in the wet condition showed the highest strength. Futhermore, the moisture evaporation loss from the board surface with sizing agent was much lower than that from the board without sizing agent. Therefore, it was clear that the sizing agent was effective for water retention. The change of thickness in the wet condition was less than 1 mm, and it showed that the board is the predominant material on the dimensional stability. The average pH value of the board was ranged from 7.6 to 8.25.

The Effect of Anchorage with Shear Reinforcement in Flat Plate System (플랫 플레이트 구조에서 전단보강체의 정착성능에 따른 전단보강효과)

  • Choi, Chang-Sik;Bae, Baek-Il;Choi, Yun-Cheul;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.667-675
    • /
    • 2012
  • Flat plate are being used more in buildings requiring a high level of technical installations or in buildings needing changeable room arrangements during their life time such as office buildings. The main problem in flat plate is its weak resistance against a punching failure at its slab-column connections. Therefore, in this research, an experimental study on full-scale interior slab-column connection was performed. Three types of shear reinforcements were tested to prevent brittle punching shear failure that could lead to collapse of the structure. A series of four flat plate specimens including a specimen without shear reinforcement and three specimens with shear reinforcements were tested. The slabs were tested up to failure using monotonic vertical shear loading. The presences of the shear reinforcements substantially increased punching shear capacity and ductility of the interior slabcolumn connections. The test results showed that a slab that did not have enough bond length failed before shear reinforcement yielded due to anchorage slip. Also, FEM analyses were performed to study an effect of slab thickness and concrete compressive strength on the flat plate slab. The analytical study results were used to propose a method to calculate performance capacity of shear reinforcement in slab-column connection.

Preparation of Talc-Silica Composites by Controlling Surface Charge Behavior (표면전하 거동 조절을 이용한 탈크-실리카 복합체의 제조)

  • Yun, Ki-Hoon;Park, Min-Gyeong;Moon, Young-Jin;Lee, Dong-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.116-124
    • /
    • 2017
  • A plate-type inorganic pigment complex was manufactured in a manner that treats the surface of the complex by adjusting zeta potential between talc, an inorganic pigment used as a material for color cosmetics, and hydrophobic silica. Talc, which is usually used in the prescription of color cosmetics, is a plate-type, white-colored inorganic substance with good application and spreadability to skin. Furthermore, it features excellent dispersibility and extensibility as well as outstanding heat tolerance, light stability, and chemical resistance. In general, silica contributes to durable makeup and stabilized formulation. This paper covers a process of manufacturing an inorganic pigment complex, where hydrophobic silica was applied to the surface of talc by using differences in zeta potential after the surface charges of talc and hydrophobic silica had been adjusted with cationic and anionic surfactants, respectively. The resulting inorganic pigment complex was composed of talc whose surface is coated hydrophobic silica to the thickness of $1{\mu}m$ or less, which developed an effective hydrophobic property. Zeta potential was measured to analyze the surface charge of an inorganic pigment, and FT-IR, used to check the functional group of a surfactant, was applied to treat the surface of the pigment. The surface of the inorganic pigment complex was observed employing SEM, EDS, and FIB, while its structure was confirmed with XRD and FT-IR.