• Title/Summary/Keyword: Effective Thickness

Search Result 1,967, Processing Time 0.039 seconds

Effect of Non-invasive Transcutaneous Electrical Stimulation in Women With Stress Urinary Incontinence: A Prospective Study

  • Ji-hyun Kim;Hye-seon Jeon;Oh-yun Kwon;Ui-jae Hwang;Eun Young Park;Su-jin Kim
    • Physical Therapy Korea
    • /
    • v.31 no.2
    • /
    • pp.167-173
    • /
    • 2024
  • Background: Stress urinary incontinence (SUI) impacts the social, physical, and psychological well-being and quality of life of the patient. Several techniques exist for its management, including transcutaneous electrical stimulation (TES). Objects: We aimed to demonstrate the effects of TES on ultrasonographic variables and quality of life in women with SUI. Methods: This prospective study recruited 21 women who had been diagnosed with grade 1 or 2 SUI between July 2018 and March 2019. The exclusion criteria were pregnancy and a history of urogenital surgery. All participants were assessed at baseline and 8 weeks after intervention initiation. The bladder neck position (BNP), length of the urethra (LU), funneling index (FI), and rhabdosphincter thickness (RT) were measured. The Incontinence-Quality of Life (I-QOL) was used to assess incontinence-specific quality of life. Statistical significance level was set at p < 0.05. Results: Twenty-one patients with SUI used TES for 8 weeks. BNP and FI significantly decreased after intervention (p < 0.05). LU, anterior and posterior RT (indicators of external sphincter hypertrophy) significantly increased post-intervention (p < 0.05). The total I-QOL score increased from 64.81 to 71.86 after the intervention (p < 0.05). Conclusion: This intervention improved BNP, LU, FI, RT, and subjective indicators such as quality of life in women with SUI. Therefore, TES can be an effective non-surgical treatment method for improving SUI symptoms and quality of life in these patients.

Comparative Flexural Performance of Concrete Panels Reinforced with Ring-Type Steel Fibers and with Hooked-End Straight Steel Fibers (링 형태 강섬유와 양단갈고리 선형 강섬유 보강 콘크리트 패널의 휨성능 비교)

  • Lee, Chadon;Cho, Won-Tack
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.169-178
    • /
    • 2009
  • Ring-type steel fibers (RSFs) of the closed circular shape, have different resistance mechanisms other than straight steel fibers. RSFs also maintain the same value of the orientation factor for the plane enclosed by the fiber ring perimeter. In this research, comparative studies were performed for the panels reinforced with RSFs and with straight steel fibers of $15kg/m^3$ and $30kg/m^3$, respectively. Resisting mechanisms of RSFs were identified and higher toughness indices were experimentally observed for the concrete panels reinforced with RSFs than with straight steel fibers. Orientation factor for the RSF was suggested. It was found that RSFs were more effective in increasing toughness for the panel specimens with relatively thinner thickness than beam specimens.

Comparative Effects of Phytase Derived from Escherichia coli and Aspergillus niger in Sixty Eight-week-old Laying Hens Fed Corn-soy Diet

  • Yan, L.;Zhou, T.X.;Jang, H.D.;Hyun, Y.;Kim, H.S.;Kim, I.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.10
    • /
    • pp.1391-1399
    • /
    • 2009
  • Two hundred and sixteen 68-week-old Hy-Line brown laying hens were used in a 6-week feeding trial to compare the efficacy of phytases Optiphos (OPT) and Natuphos (NAT), which were isolated from Escherichia coli and Aspergillus niger, respectively. Hens were randomly allotted into six treatments with six replications (six layers in three adjacent cages) per treatment according to their initial BW. The hens were then subjected to one of the following dietary treatments: i) Positive Control (PC; available phosphorus (AP) 0.4%); ii) Negative control (NC; AP 0.2%); iii) NAT1 (NC+250 FTU/kg NAT); iv) NAT2 (NC+500 FTU/kg NAT); v) OPT1 (NC+250 FTU/kg OPT); vi) OPT2 (NC+500 FTU/kg OPT). Feed intake, egg production, egg quality, apparent nutrient digestibility and serum P and Ca concentration were evaluated to compare the effect of the two phytases. Feed intake and eggshell thickness were not affected by the treatments. Superior effects (p<0.05) of OPT were only observed in egg production and egg weight compared with NAT. Characteristics such as eggshell breaking strength, apparent digestibility of N, Ca and P and serum P concentration were equally increased with the supplementation of both phytases (p<0.05), where no significant difference was observed in those characteristics between PC and phytase supplementation at 500 FTU/kg. Equally effective improvements (p<0.05) were also observed in egg production and DM digestibility, where no improvements were observed (p<0.05) between the PC group and the groups with phytase supplementation at 500 FTU/kg. Equal increases in the serum Ca level were observed when the groups with phytase supplementation were compared to the PC group. Overall, the results of this study suggest that NAT and OPT are equally effective at liberating phytate-bound complexes when included in 0.2% available phosphorus diets for 68-week laying hens; either source of phytase can be fed to commercial 68-week laying hens at 500 FTU/kg to correct the negative effects associated with a 0.2% available phosphorus diet. In conclusion, either source of phytase can be fed to commercial first cycle laying hens at 500 FTU/kg to effectively replace inorganic phosphorus when economically justified.

A Study on Influences of Waterproofing Admixtures for Concrete on Self-Healing Properties of Hardened Cement Paste (시멘트페이스트 경화체의 Self-Healing 특성에 미치는 구체방수재의 영향)

  • Kim, Jae-Young;Byun, Seung-Ho;Ma, Sang-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.109-116
    • /
    • 2008
  • This study was performed to get information of self-healing mechanism in cement system and the influence of waterproofing admixtures for concrete on self-healing property. For testing, cement paste specimens cured for 7, 14 and 28 days were prepared and crushed into plate-shape pieces. Screened specimens with thickness not more than 1mm were covered with wet rags and cured in a plastic container for 7 and 28 days. After stopping hydration process of the specimens by treatment with acetone, the surfaces of specimens have been contacted with wet rags were analyzed by XRD, DSC, SEM and EDX. The analysis results showed that cement paste has self-healing property and this property is mainly affected by water. Self-healing in cement system is more effective and faster at an early stage of hydration as there is enough content of unreacted cement to make an additional hydration in this period. The results of this study also showed that waterproofing admixtures for concrete have a considerable effect on self-healing of cement pastes; i.e., they improved self-healing effect of cement and, especially, the specimen using admixture C has shown a lot of needle-like or fibrous hydration products which are estimated as ettringite. It is supposed that these ettringite products are effective to enhance self-healing in cement system.

Effects of skin temperature change, cold pain and muscle activity by Cold Air Application type on the induced delayed onset muscle soreness (지연성 근육통 유발 후 냉기 적용 방법이 피부온도의 변화, 냉각 통과 근육 기능에 미치는 효과)

  • Choi, Yoorim;Jung, Bongjae;Hwang, Byeongjun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.99-106
    • /
    • 2013
  • The purpose of this study was to after induced delayed onset muscle soreness, the purpose of this study is to present the effective way on skin temperature changes and cold pain for 14 subjects during to applied with only Cold-jet stream and Cold-jet stream with infra red. 14 healthy men and women who delayed onset muscle soreness eccentric contractions induced by exercise and then the biceps alone was applied to the Cold-jet stream. We measured the time that skin temperature fall from room temperature to $10^{\circ}C$(first period), the time rewarmed from $10^{\circ}C$ to $20^{\circ}C$(second period), the time fall again to $10^{\circ}C$(third period) and the time rewarmed again to $20^{\circ}C$(fourth period). Cold-jet stream with infrared combination therapy was performed with the same method. Results of this study were 1st and 2nd experimental cooling experiments in the to fall to $10^{\circ}C$ Cold-jet stream with infrared combination therapy than in the Cold-jet stream was longer(p<.05). At second period, It took longer in Cold-jet stream with infrared rewarmed than Cold-jet stream to rewarm skin(p<.05). Cold-jet stream with infrared combination therapy than Cold-jet stream had less incidence of cold pain(p<.05). Thickness of biceps brachii were found significant difference related measurment each group was consistent. In this study, Cold-jet stream with infrared combination therapy more effective than Cold-jet stream in reduced cold pain and lowering skin temperature. This work was supported by education capacity building project fund of Taegu Science University, 2012.

The design of a single layer antireflection coating on the facet of buried channel waveguide devices using the angular spectrum method and field profiles obtained by the variational method (Variational 방법으로 구한 필드 분포와 Angular Spectrum 방법을 사용한 Buried채널 도파로 소자 단면의 단층 무반사 코팅 설계)

  • 김상택;김형주;김부균
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.51-57
    • /
    • 2002
  • We have calculated the optimum refractive index and normalized thickness of a single layer antireflection coating on the facet of buried channel waveguides as a function of waveguide width for several waveguide depths using the angular spectrum method and field profiles obtained by the effective index method (EIM) and the variational method (VM), respectively, and discussed the results. In the area of large waveguide width, the optimum parameters of a single layer antireflection coating obtained by both methods are almost the same. However, as waveguide width decreases, the parameters obtained by the VM approach those of a single layer antireflection coating between cladding layer and air, while those obtained by the EIM do not approach those, and the difference between the two parameters is large. The tolerance maps of the quasi-TE and quasi-TM modes obtained by the VM for square waveguides are located in almost the same area regardless of refractive index contrast, while those obtained by the free space radiation mode (FSRM) method for refractive index contrast of 10% are located in the different area. Thus, we think that the tolerance maps obtained by the VM are more exact than those obtained by the FSRM method.

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE STRESS DISTRIBUTION ACCORDING TO THE THREAD DESIGNS AND THE MARGINAL BONE LOSS OF THE IMPLANTS (임프란트 나사형태와 치조골 흡수에 따른 응력분산의 3차원 유한요소법적 분석)

  • Kim, Il-Kyu;Son, Choong-Yul;Jang, Keum-Soo;Cho, Hyun-Young;Baek, Min-Kyu;Park, Sheung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.60-71
    • /
    • 2008
  • The objective of this study is to evaluate the stress distribution according to the thread design and the marginal bone loss of a single unit dental implant under the axial and offset-axial loading by three dimensional finite element analysis. The implants used had the diameter of 5mm and 4mm with 13mm in length and prosthesis with a conical type which is 6mm in height and 12mm in diameter. The thread designs were triangular, square and buttress. In the three dimensional finite element model with $15\times15\times20mm$ hexahedron and 2mm cortical thickness, implants were placed with crown to root ratio 7:12, 10:9, 13:6 and 16:3. And additionally the axial force of 100N were applied into 0mm, 2mm and 4mm away from the center of the implants. The results were as follows 1. The maximum von-Mises stress in cortical bone was concentrated to cervical area of implant, and in cancellous bone, apical portion. 2. Comparing the von-Mises stresses in cortical bone of 2mm and 4mm offset loading with central axial loading, it were increased to 3 and 5 times in diameter 4mm implant, and 2 and 4 times, in diameter 5mm implant. 3. The square threads were more effective than the triangular and butress as the longer diameter, the offset loading, and the worse crown to root ratio. 4. The von-Mises stresses were relatively stable until crown to root ratio 13:6, but it was suddenly increased at 16:3. From the results of this study, minimum requirement of crown to root ratio of implant is 2:1, and in the respect of crown to root ratio, diameter and offset loading, square threads are more effective than triangular and buttress threads.

EFFECT OF CONTAMINANTS ON THE PUTTY-WASH BOND STRENGTH IN TWO-STEP RELINE TECHNIQUE USING VINYL POLYSILOXANE IMPRESSION MATERIALS (Vinyl Polysiloxane 인상재를 이용한 이회 인상법에서 contaminants가 putty-wash 결합력에 미치는 영향)

  • Kim, Mu-Hyon;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.266-276
    • /
    • 1996
  • Numerous factors are known to affect the accuracy of elastomeric impression materials. Factor often overlooked is the quality of the bond between putty and wash during corrective reline impression technique. The putty-wash bond strength must be strong enough to over-come the local stress at putty-wash interface. It is not always possible to avoid saliva contamination in making corrective wash impres-sion. And putty preliminary impression material con be used as a template for provisional restoration. Human saliva and the residual monomer of autopolymerizing acrylic resin are thought to affect the bond strength and the failure type. This study examined the effect of contaminants like human saliva, and residual resin monomer on the putty-wash bond strength and the effectiveness of treatment. 1. Of the tested three brands of Vinyl Polysiloxane impession meterial, Express Exhibited the greatest bond strength followed by Eamix and Perfect showed the lowest putty-wah bond strength. 2. Coating the putty substrates with human saliva did not produce decreased failure load in all the breands of Vinyl Polysiloxane impression meterail. 3. Of the three brands of VPS impression material that were exposed to methhylmethacry-late resin(Jet), only the putty-wash bond strength of the Perfect group diminished signifi-cantly. Moreover, all the specimens from group C of Perfect exhibited adhesive failure. 4. Exposing the substrates to ethylmethacrylate resin(SNAP. diminished the putty-wash bond strength significantly. With Perfect and Examix, failure occurred cohesively through the light-body, whereas with Express, failure occurred adhesive-cohesively. 5. Removing approximately 1mm thickness of the contaminated putty interface was the most effective treatment in countering the undesirable effect caused by residual resin monomer. The putty-wash bond strength of the groups that were treated with 1mm even putty reduction was not significantly different from those of control groups. With Perfect and Examix, cleaning the specimens with gauze soaked in 70% isopropyl alcohol increased the putty-wash bond strength, but was not as effective as 1mm even reduction of contaminated putty substrates. With Express, 70% isoproryl alcohol treatment exhibi0ted comparable putty-wash bond strength to that of control group.

  • PDF

High Efficient Inductive Power Supply System Implemented for On Line Electric Vehicles

  • Huh, Jin;Park, Eun-Ha;Jung, Gu-Ho;Rim, Chun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.105-110
    • /
    • 2009
  • The On Line Electric Vehicles(OLEV) that can pick up inductive power from underground coils on driving with high efficiency have been developed this year, and is now proposed in this paper. The IPS(Inductive Power Supply) system consists of power supply inverters, power supply rails, pick up modules, and a regulator. There are 3 generations of IPS have been developed so far, and the $4^{th}$ generation IPS is being developed. The $1^{st}$ generation has been demonstrated this Feb. 27, which is equipped with mechanically auto tracking pick-up module with 1cm air gap, and showed 80% power efficiency. The $2^{nd}$ generation IPS applied to an 120kW (average)/240kW(peak) motor powered electric bus has 17cm air gap with 72% power efficiency. For the $2^{nd}$ generation IPS, the Power supply inverter has 440V, 3phase input and 200A @ 20kHz output. The test power supply rail of 240m long is segmented by 60m each, where newly developed core structure and power cable are constructed under the road covered with asphalt of 5cm thickness. The pick-up modules which consist of core, winding wire, and rectifiers are fixed to the bottom of the bus which can carry more than 40 passengers and can pick up max. 60kW. To remove parasitic component and to transfer maximum power between them resonant circuit topology is applied to the primary and secondary sides. The EMF level is below 62.5mG at 1.75m from the center of the road to meet the regulation. Several effective ways of reducing EMF levels have been developed. In addition, effective ways to solve problems related high frequency power cables buried in ground and it's proof from soil have been studied also. This development shows that the IPS system is capable of supplying enough power to the pick-up of OLEV and can reduce battery size, weight and cost, which means the IPS with OLEV is one of the best candidate for EV.

  • PDF

Robust 1D inversion of large towed geo-electric array datasets used for hydrogeological studies (수리지질학 연구에 이용되는 대규모 끄는 방식 전기비저항 배열 자료의 1 차원 강력한 역산)

  • Allen, David;Merrick, Noel
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.50-59
    • /
    • 2007
  • The advent of towed geo-electrical array surveying on water and land has resulted in datasets of magnitude approaching that of airborne electromagnetic surveying and most suited to 1D inversion. Robustness and complete automation is essential if processing and reliable interpretation of such data is to be viable. Sharp boundaries such as river beds and the top of saline aquifers must be resolved so use of smoothness constraints must be minimised. Suitable inversion algorithms must intelligently handle low signal-to-noise ratio data if conductive basement, that attenuates signal, is not to be misrepresented. A noise-level aware inversion algorithm that operates with one elastic thickness layer per electrode configuration has been coded. The noise-level aware inversion identifies if conductive basement has attenuated signal levels so that they are below noise level, and models conductive basement where appropriate. Layers in the initial models are distributed to span the effective depths of each of the geo-electric array quadrupoles. The algorithm works optimally on data collected using geo-electric arrays with an approximately exponential distribution of quadrupole effective depths. Inversion of data from arrays with linear electrodes, used to reduce contact resistance, and capacitive-line antennae is plausible. This paper demonstrates the effectiveness of the algorithm using theoretical examples and an example from a salt interception scheme on the Murray River, Australia.