• Title/Summary/Keyword: Effective SNR

Search Result 166, Processing Time 0.025 seconds

Analysis and Comparison of MR Signal Strength and SNR Value for Optimal FOV (최적의 FOV를 위한 MR신호강도와 신호 대 잡음비 값의 비교분석)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.109-113
    • /
    • 2018
  • Despite the continuous development of software, it is continuously pursued to enlarge the examination area of FOV in order to reduce the factors of inconsistency in images that appear in continuous examination during wide area examination using contrast agent such as whole body angiography. In this study, we investigated the optimal FOV by comparing the SNR values according to the changes of FOV. The change of the FOV was gradually changed to $270{\times}200$, $300{\times}223$, $330{\times}244$, $360{\times}266$ and $380{\times}281$. SE images at TR 450 msec and TE 10 msec, FSE images at TR 2,000 msec, TE 80 msec, and GE images were scanned at TR 117 msec, and TE 16 msec. SNR values were calculated from the mean values of signal intensities of five phantom images and the signal intensity values of four background standard deviations. As a result of the study, the signal intensity and the SNR value according to the change of the FOV value gradually increased as the FOV was increased, but it was found that the SNR value decreased at a constant size. In conclusion, the results are different from previous studies that the SNR increases as the FOV increases. The cause of these results could not be confirmed. However methods that can be imaged and included within the effective FOV should be considered.

Performance Analysis of Hybrid Concatenated Convolutional Codes over AWGN and Rayleigh/Rician Fading Channels (가산성 백색 가우시안 잡음과 레일레이/라이시안 페이딩 채널에서 하이브리드 연쇄 길쌈부호의 성능 분석)

  • 김세훈;윤원식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1A
    • /
    • pp.43-47
    • /
    • 2000
  • In regions of low signal-to-noise ratio (SNR), performance analysis uses simulations of hybrid concatenated coding systems. However, for higher SNR regions beyond simulation capabilities, average upper bounds to bit error rate (BER) and word error rate (WER) are used. In [1], all weight enumerating functions are needed to obtain average bounds. In this paper, we use RSC as constituent codes, by using effective free distances instead of WEF, we derive average BER and WER bounds of hybrid concatenated convolutional codes (HCCC) and analyze the BER and WER over AWGN and Rayleigh/Rician fading channels.

  • PDF

The Calculation of Target Recognition rate by SNR of a Detection System (탐지시스템의 SNR에 의한 물체인식능력산출)

  • 김도현;신재호;배정이
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.690-698
    • /
    • 1990
  • Among the target identification algorithms presented up to now, the NNR algorithm utilize multifrequency and single observation method. But it is generally known that its implementation is extremely difficult. In this paper a new identification algorithm using the single frequency and cumulative observation method was proposed. The simulation result shows that the proposed algorithm with 31 observation and accumulation is more effective and realizable than the NNR with 3 freqnencies when the noise level n is below 0.3.

  • PDF

A Novel Approach to a Robust A Priori SNR Estimator in Speech Enhancement (음성 향상에서 강인한 새로운 선행 SNR 추정 기법에 관한 연구)

  • Park, Yun-Sik;Chang, Joon-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.8
    • /
    • pp.383-388
    • /
    • 2006
  • This Paper presents a novel approach to single channel microphone speech enhancement in noisy environments. Widely used noise reduction techniques based on the spectral subtraction are generally expressed as a spectral gam depending on the signal-to-noise ratio (SNR). The well-known decision-directed(DD) estimator of Ephraim and Malah efficiently reduces musical noise under the background noise conditions, but generates the delay of the a prioiri SNR because the DD weights the speech spectrum component of the Previous frame in the speech signal. Therefore, the noise suppression gain which is affected by the delay of the a priori SNR, which is estimated by the DD matches the previous frame rather than the current one, so after noise suppression. this degrades the noise reduction performance during speech transient periods. We propose a computationally simple but effective speech enhancement technique based on the sigmoid type function for the weight Parameter of the DD. The proposed approach solves the delay problem about the main parameter, the a priori SNR of the DD while maintaining the benefits of the DD. Performances of the proposed enhancement algorithm are evaluated by ITU-T p.862 Perceptual Evaluation of Speech duality (PESQ). the Mean Opinion Score (MOS) and the speech spectrogram under various noise environments and yields better results compared with the fixed weight parameter of the DD.

Performance Analysis of Asymmetric Turbo Codes Using SOVA Decoding Algorithm (SOVA 복호방법을 이용한 비대칭구조 터보부호의 성능분석)

  • 신한균;강수훈;최회동;노종선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4A
    • /
    • pp.553-557
    • /
    • 2000
  • It is known that turbo codes have an error-floor bound according to the effective free distance at high SNR. But the performance for turbo codes in the water-fall area at low SHR has not been studied yet. In this paper, asymmetric turbo codes that consist of RSC(recursive systematic convolutional) codes with different constraint length are proposed and their performance is analysed for SOVA decoding algorithm.

  • PDF

Evaluation of a signal segregation by FDBM (FDBM의 음원분리 성능평가)

  • Lee, Chai-Bong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.12
    • /
    • pp.1793-1802
    • /
    • 2013
  • Various approaches for sound source segregation have been proposed. Among these approaches, frequency domain binaural model(FDBM) has the advantages of low computational load and effective howling cancellation. A binaural hearing assistance system based on FDBM has been proposed. This system can enhance desired signal based on the directivity information. Although FDBM has been evaluated in terms of signal-to-noise ratio (SNR) and coherence function, the evaluation results do not always agree with the human impressions. These evaluation methods provide physical measures, and do not take account of perceptual aspect of human being. Considering a binaural hearing assistance system as a one of major applications, the quality of segregated sound should keep level enough. In the paper, signal segregation performance by means of FDBM is evaluated by three objective methods, i.e., SNR, coherence and Perceptual Evaluation of Speech Quality(PESQ), to discuss the characteristic of FDBM on the sound source segregation performance. The simulation's evaluation results show that FDBM improves the quality of the left and right channel signals to an equivalent level. And the results suggest the possibility that PESQ provides a more useful measure than SNR and coherence in terms of the segregation performance of FDBM. The evaluation results by PESQ show the effects from segregation parameters and indicate appropriate parameters under the conditions. In the paper, signal segregation performance by means of FDBM is evaluated by three objective methods, i.e., SNR, coherence and PESQ, to discuss the characteristic of FDBM on the sound source segregation performance. The simulation's evaluation results show that FDBM improves the quality of the left and right channel signals to an equivalent level. And the results suggest the possibility that PESQ provides a more useful measure than SNR and coherence in terms of the segregation performance of FDBM. The evaluation results by PESQ show the effects from segregation parameters and indicate appropriate parameters under the conditions.

Image Denoising for Metal MRI Exploiting Sparsity and Low Rank Priors

  • Choi, Sangcheon;Park, Jun-Sik;Kim, Hahnsung;Park, Jaeseok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.215-223
    • /
    • 2016
  • Purpose: The management of metal-induced field inhomogeneities is one of the major concerns of distortion-free magnetic resonance images near metallic implants. The recently proposed method called "Slice Encoding for Metal Artifact Correction (SEMAC)" is an effective spin echo pulse sequence of magnetic resonance imaging (MRI) near metallic implants. However, as SEMAC uses the noisy resolved data elements, SEMAC images can have a major problem for improving the signal-to-noise ratio (SNR) without compromising the correction of metal artifacts. To address that issue, this paper presents a novel reconstruction technique for providing an improvement of the SNR in SEMAC images without sacrificing the correction of metal artifacts. Materials and Methods: Low-rank approximation in each coil image is first performed to suppress the noise in the slice direction, because the signal is highly correlated between SEMAC-encoded slices. Secondly, SEMAC images are reconstructed by the best linear unbiased estimator (BLUE), also known as Gauss-Markov or weighted least squares. Noise levels and correlation in the receiver channels are considered for the sake of SNR optimization. To this end, since distorted excitation profiles are sparse, $l_1$ minimization performs well in recovering the sparse distorted excitation profiles and the sparse modeling of our approach offers excellent correction of metal-induced distortions. Results: Three images reconstructed using SEMAC, SEMAC with the conventional two-step noise reduction, and the proposed image denoising for metal MRI exploiting sparsity and low rank approximation algorithm were compared. The proposed algorithm outperformed two methods and produced 119% SNR better than SEMAC and 89% SNR better than SEMAC with the conventional two-step noise reduction. Conclusion: We successfully demonstrated that the proposed, novel algorithm for SEMAC, if compared with conventional de-noising methods, substantially improves SNR and reduces artifacts.

The Simulation of 747 Curve for Hard Disk Drive System (하드 디스크 드라이브 시스템의 747 곡선 시뮬레이션)

  • 서정교;조순철;김용수;박노열
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.2
    • /
    • pp.97-102
    • /
    • 1997
  • Off-track capability is used to determine the track pitch of hard disk drive system, and the off-track capability as a function of track pitch is called 747 curve. In this paper, 747 curves were simulated with computer. Side reading and recording parameters were obtained by magnetic field analysis using 3-D finite element method. Head read signal and noise voltages for calculation of signal to noise ratio (SNR) were obtained using reciprocity theorem. According to the 747 curves thus obtained, the off-track capability was increased as erase band width increased and as effective signal to noise ration $(SNR_{eff}}$ decreased. A simulated 747 curve and a measured 747 curve (using spin stand) of a planar silicon head with track width of 4.1 um were very similar, which indicated that the simulation was carried out properly.

  • PDF

Analysis of Scatter Ray Distribution Using GEANT4-GATE Simulation and Effectiveness of Silicone Pad in Digital Mammography (디지털유방촬영에서 Geant4-GATE를 이용한 산란선의 영향분석과 감소방안에 관한 연구)

  • Kim, Myeong-soo;Kim, Young-kuen;Jang, Young-Il
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.175-180
    • /
    • 2019
  • In this study, we have researched the effectiveness of silicone pad. A distribution of scatter ray in mammography was evaluated using Monte-Carlo (MC) simulation technique and then a silicone pad was applied to remove the scatter ray for improving image quality. Molybdenum target and Molybdenum filter combination made a difference of 59.8% to a number of photon at 17.5 keV. On the other hand, Tungsten target and Rhodium filter showed a variation of 24.5% at 20 keV. Mean 68 of SNR was increased in Selenia and mean 1.04 of SNR was raised in Senographe. Silicone pad was significantly effective to reduce the scatter ray that was generated by primary X-ray. It can decrease an absorption rate of scatter ray to patient body and whilst it improve the image quality from increasing SNR.

Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography (흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.139-145
    • /
    • 2021
  • This study is to confirm the range of tube voltage for Chest X-ray in DR system by comparing with dose area product (DAP) and effective dose in efficient detector exposure index (DEI) range. GE definium 8000 was used to for the phantom study. The range of tube voltage is 60~130 kVp and of mAs is 2.5~40 mAs. The acquired images were classified into efficient DEI groups, then calculated effective dose with DAP by using a PC-Based Monte Carlo Program 2.0. The signal to noise ratio (SNR) was measured at 4 regions, including the thoracic spine, the lung area with the ribs, the lung area without the ribs, and the liver by using Picture Archiving and Communication System. The significance of the group for each tube voltage was verified by performing the kruskal-wallis test and the mann-whitney test as a post-test. When set to 4 groups dependned on the tube voltage, DAP showed significant differences; 60 kVp and 80 kVp, and 60 kVp and 90 kVp (p= 0.034, 0.021). Effective dose exhibited no statistically significant differences from the all of the group (p>0.05). SNR exhibited statistically significant differences from the all of the group in the liver except compared to 80 kVp and 90 kVp (p<0.05). Therefore, high tube voltages of 100 kVp or more need to be reconsidered in terms of patient dose and imaging in order to represent an appropriate chest X-ray image in a digital system.