• 제목/요약/키워드: Effective Impedance

검색결과 366건 처리시간 0.031초

누설전류로 인한 전기화재 및 감전사고 예방기법 (Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current)

  • 김동우;임용배;이상익;김재현;강대철
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks

  • Jaipradidtham, Chamni
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1637-1640
    • /
    • 2005
  • This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground conductivity influences both the electric field as well as the coupling mechanism and hence the magnitude and wave shape of the induced voltage. The technique can be used to analyzed the corona voltage effect, the effective of stroke to the span tower, the surge impedance of transmission lines. The maximum voltage from flashovers effects in the lines. The model is compatible with general electromagnetic transients programs such as the ATP-EMTP. The simulation results show that this study analyses for time-domain with those produced by a cascade multi-section model, the surge impedance of a full-sized tower hit directly by a lightning stroke is discussed.

  • PDF

촉매량 변화에 따른 직접 메탄올 연료전지의 성능 특성에 관한 연구 (A Study on the Performance Characteristics of Direct Methanol Fuel Cell with Changing of Catalyst Loading)

  • 서상헌;이창식
    • 한국수소및신에너지학회논문집
    • /
    • 제19권6호
    • /
    • pp.467-473
    • /
    • 2008
  • This study is to investigate the influence of catalyst loading quantity on the direct methanol fuel cell (DMFC) performance. In this paper, Pt-Ru and Pt-black loading as the catalyst were varied from 1 to $4mg/cm^2$ at the anode and cathode, respectively. The experiment was conducted with single fuel cell consisted of $5cm^2$ effective electrode area, serpentine type flow pattern and Nafion 117 membrane. Also, AC impedance and methanol crossover current were measured to investigate the performance loss precisely. As a result, the performance of fuel cell was significantly increased with the increase of cathode catalyst loading. However, the performance did not increase further above a certain Pt-Ru catalyst loading as the increase of anode catalyst loading.

금속섬유 복합재료의 부하저항에 따른 분산특성 (The Effect of the Load Resistance on Dispersion Characteristics of Metal-Fiber Composites)

  • 서동욱
    • 전자공학회논문지SC
    • /
    • 제49권3호
    • /
    • pp.75-81
    • /
    • 2012
  • 최근에 소개된 능동 FSS(active frequency selective surface) 또는 ESS(electromagnetic smart screen)는 2차원 금속섬유 복합재료에서 금속섬유의 부하저항을 변화시킴으로써 복합재료의 분산특성을 변경시키는 기술이다. 본 논문에서는 부하저항의 변화에 따른 ESS의 분산특성을 효율적으로 계산하기 위해 GEC(generalized equivalent conductor) 기법을 기반으로 수정하여 적용한다. 부하저항에 따른 ESS의 투과계수와 유효유전율을 1~40 GHz의 범위에서 시뮬레이션 한다. 또한, 부하저항을 변경함으로써 공진주파수와 대역폭을 변경할 수 있음을 보인다.

드릴쉽 디젤엔진 발전기의 진동에 관한 연구 (Study on the Vibration of Diesel Engine Generator of Drill Ship)

  • 진봉만;박형식;공영모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권4호
    • /
    • pp.502-508
    • /
    • 2009
  • To obtain high power, diesel engines continuously increase combustion pressure and mean effective pressure each cylinder, and the excitation sources and noisy sources are increased, too. Moreover, to reduce the costs, shipyards make hull structures weaker than before. As above reasons, it is more difficult to control the vibration phenomenon nowadays. In this study, it was investigated why diesel generator sets reached the vibration allowable limits during the FAT and heavy vibration phenomenon of diesel generator sets using ODS test during onboard tests. Also, it is found out the stiffness of deck and common bed using the test result of their structural impedance. To find out the vibratory characteristics of diesel generator sets, model tests were carried out. From the sensitivity analysis after above tests, it was selected points to be reinforced and studied troubleshooting to solve heavy vibration phenomenon of diesel generator sets.

임펄스 전류에 대한 메쉬접지계의 과도임피던스 특성 (Transient Impedance Characteristics of Mesh Grounding System under Impulse Current)

  • 이복희;박종순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.361-363
    • /
    • 1997
  • Electronic devices are very weak against lightning surges injected from grounding systems and can be damaged. The malfunction and damage of electronic circuits bring about several disadvantages such as low operation performances, a lot of economical losses, and etc. In order to obtain the effective protection measure of electronic devices from overvoltages and lightning surges, the analysis of the transient grounding impedances is very important. The aim of this work is to evaluate the behaviors of transient grounding impedances under impulse currents and to investigate the effect of grounding lead wire. Z-t, Z-i and V-i curves of transient grounding impedance under impulse current waveforms have been measured and analyzed.

  • PDF

전력용 변전소에 설치된 메쉬 접지망의 고주파 임피던스 계산 (High Frequency Impedance Calculation of Grounding Meshes Installed at Power Substations)

  • 한풍;최창혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1578-1582
    • /
    • 1998
  • The ground potential rise generated by the switching surge or lightning stroke may be dangerous to personnel and cause damage to electronic control parts. For a first step to the transient performance analysis. high frequency impedances of grounding grids have been calculated and discussed. Grounding grids include 7 square grids from $10m{\times}10m$ to $80m{\times}80m$. The high frequency current was injected into the center and a corner of the grounding grid. The calculation results indicate that the impedance of the grounding grid is significantly influenced by frequency and the point of injection of the current. and the effective radius of a large grounding grid may be represented in $15{\sim}20m$.

  • PDF

X-Band Phased Array Antenna Using Ferroelectric $(Ba,Sr)TiO_3$ Coplanar Waveguide Phase Shifter

  • Moon, Seung-Eon;Ryu, Han-Cheol;Kwak, Min-Hwan;Kim, Young-Tae;Lee, Su-Jae;Kang, Kwang-Yong
    • ETRI Journal
    • /
    • 제27권6호
    • /
    • pp.677-684
    • /
    • 2005
  • A phased array antenna was fabricated using four-element ferroelectric phase shifters with a coplanar waveguide (CPW) transmission line structure based on a $Ba_{0.6}Sr_{0.4}TiO_3(BST)/MgO$ structure. Epitaxial BST films were deposited on MgO (001) substrates by pulsed laser deposition. To attain the large differential phase shift and small losses for a ferroelectric CPW phase shifter, an impedance-matching-part adding technique between the effective transmission line and connecting cable was used. The return loss and insertion loss for this techniqueadapted BST CPW device were improved with respect to those for a normal BST CPW device. For an X-band phased array antenna system consisting of ferroelectric BST CPW phase shifters, power divider, dc block, patch antenna, and programmed dc power, the steering beam could be tilted by $15^{\circ}$ in either direction.

  • PDF

정보화 건측물을 위한 접지감시시스템 개발 (Development of the grounding monitoring system for intelligent buildings)

  • 조성철;이태형;엄주홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.196-197
    • /
    • 2006
  • An effective method is described for monitoring the ground impedance of intelligent building and power system. Most of grounding system of buildings are interconnected to extensive grounding network of power line, signal and control line, telecommunication line, and etc. Therefore, the residual voltages of power frequency and its harmonics may have an significant influence on the accurate measurement of ground impedance. For eliminating the influence of residual voltage, we developed a test power source for generating the 110[Hz] square wave and used digital filtering method in this research.

  • PDF

측정선의 상호유도작용이 접지임피던스의 측정에 미치는 영향 (Effect of Mutual Coupling Between Test Leads on Ground Impedance Measurement)

  • 이복희;엄주홍;조성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.71-74
    • /
    • 2003
  • Fall-of-potential method is used usually to measure the ground impedance of large scale grounding system exactly. Because the interlinked magnetic flux between closed loops to inject test current and to measure potential rise is existed in E-P-C straight line arrangement, mutual(or inductive) coupling influences greatly on the measurement correctness. Measurement errors produced from inductive coupling could be reduced by the arrangement methods of auxiliary electrodes. Right angle or P-E-C order arrangement methods were effective to reduce the inductive coupling and the decrease degree of measurement error was analysed as quantitative through an experiment.

  • PDF