• 제목/요약/키워드: Effective

검색결과 87,227건 처리시간 0.077초

가솔린자동차의 유효방전에너지와 배기가스와의 상관관계 연구 (A Study on Correlation of Effective Discharge Energy and Exhaust Emission of Gasoline Vehicle)

  • 유종식;김철수
    • 한국자동차공학회논문집
    • /
    • 제22권7호
    • /
    • pp.70-75
    • /
    • 2014
  • The experiment was done on traveling at the speed of 20km/h, 60km/h and 100km/h using the performance testing mode for chassis dynamometer. The experimental method were employed to measure the waveform of secondary ignition coil and exhaust emission. In this experiment, the correlation between the secondary waveform coming from ignition coil and exhaust emission were measured in decrepit vehicle. The secondary waveform characterized by the value of effective discharge energy. The following results are obtained by analyzing the data relativity between the effective discharge energy and exhaust emission. The variation rate of effective discharge energy was largest 60km/h, 20km/h, 100km/h velocity in the ordered named. As the vehicle velocity increases, the average variation rate of CO and $NO_X$ decreases and that of HC and $CO_2$ decrease. The value of effective discharge energy, CO, $NO_X$ and fuel consumption is measured badly in case of car with failures in MAP, spark plug and good in case of car with before and after maintenance regardless of vehicle velocities. The value of effective discharge energy is to be nearly parabolic shape as vehicle velocity increases. As the value of effective discharge energy increases, the value of $NO_X$, HC and $CO_2$ decrease, the value of CO increase. The most sensible factors of exhaust emission were CO, $NO_X$, and the small variation factors were HC, $CO_2$.

선량 환산 관례를 이용한 생애유효선량 및 라돈피폭 위험도 예측: 대학 강의실 라돈농도 중심으로 (Prediction for the Lifetime Effective Dose and Radon Exposure Risk by using Dose Conversion Convention: Base on the Indoor Radon Concentration of Lecture Room in a University)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권6호
    • /
    • pp.243-249
    • /
    • 2018
  • The indoor radon concentration was measured in the lecture room of the university and the radon concentration was converted to the amount related to the radon exposure using the dose conversion convention and compared with the reference levels for the radon concentration control. The effect of indoor radon inhalation was evaluated by estimating the life effective dose and the risk of exposure. To measure the radon concentration, measurements were made with a radon meter and a dedicated analysis Capture Ver. 5.5 program in a university lecture room from January to February 2018. The radon concentration measurement was carried out for 5 consecutive hours for 24 hours after keeping the airtight condition for 12 hours before the measurement. Radon exposure risk was calculated using the radon dose and dose conversion factor. Indoor radon concentration, radon exposure risk, and annual effective dose were found within the 95% confidence interval as the minimum and maximum boundary ranges. The radon concentration in the lecture room was $43.1-79.1Bq/m^3$, and the maximum boundary range within the 95% confidence interval was $77.7Bq/m^3$. The annual effective dose was estimated to be 0.20-0.36 mSv/y (mean 0.28 mSv/y). The life-time effective dose was estimated to be 0.66-1.18 mSv (mean $0.93{\pm}0.08mSv$). Life effective doses were estimated to be 0.88-0.99 mSv and radon exposure risk was estimated to be 12.4 out of 10.9 per 100,000. Radon concentration was measured, dose effective dose was evaluated using dose conversion convention, and degree of health hazard by indoor radon exposure was evaluated by predicting radon exposure risk using nominal hazard coefficient. It was concluded that indoor living environment could be applied to other specific exposure situations.

Effect of packing structure on anisotropic effective thermal conductivity of thin ceramic pebble bed

  • Wang, Shuang;Wang, Shuai;Wu, Bowen;Lu, Yuelin;Zhang, Kefan;Chen, Hongli
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2174-2183
    • /
    • 2021
  • Helium cooled solid breeder blanket as an important blanket candidate of the Tokamak fusion reactor uses ceramic pebble bed for tritium breeding. Considering the poor effective thermal conductivity of the ceramic breeder pebble bed, thin structure of tritium breeder pebble bed is usually adopted in the blanket design. The container wall has a great influence on the thin pebble bed packing structure, especially for the assembly of mono-sized particles, and thin pebble bed will appear anisotropic effective thermal conductivity phenomenon. In this paper, thin ceramic pebble beds composed of 1 mm diameter Li4SiO4 particles are generated by the EDEM 2.7. The effective thermal conductivity of different thickness pebble beds in the three-dimensional directions are analyzed by three-dimensional thermal network method. It is observed that thin Li4SiO4 pebble bed showing anisotropic effective thermal conductivity under the practical design size. Normally, the effective thermal conductivity along the bed vertical direction is higher than the horizontal direction due to the gravity effect. As the thickness increases from 10 mm to 40 mm, the effective thermal conductivity of the pebble bed gradually increases.

원자력 발전소 안전체감에 관한 연구: 안전체감지수 개발과 안전체감 수준 (Developing the Nuclear Effective Safety Index)

  • 최인철 ;김범준
    • 한국심리학회지 : 문화 및 사회문제
    • /
    • 제13권3호
    • /
    • pp.1-21
    • /
    • 2007
  • 본 연구에서는 1) 원자력 발전소 지역 주민들의 안전체감을 구성하고 있는 하위요인들을 규명하고, 2) 그 구성요소들의 측정을 통해 주민들의 안전체감지수를 산출하며, 3) 주민들이 체감하는 안전의 정도와 발전소 직원들이 추측하는 주민들의 안전 체감 정도를 비교하였다. 이를 위해 원자력 발전소 지역주민 800명을 대상으로 연구 1과 발전소 직원 187명을 대상으로 연구 2가 수행되었다. 연구 결과에 따르면, 안전체감은 커뮤니케이션, 신뢰, 발전소 위험대응역량, 그리고 응급대응역량의 4가지 요소로 구성되어 있는 것으로 밝혀졌다. 개발된 안전체감 지수에 따르면 발전소 지역 주민들의 안전체감 수준은 매우 낮았으며(100점 만점에 38.22점), 이 점수는 발전소 지역에 따라 다른 것으로 나타났다. 또한 원자력 발전소의 직원들은 주민들이 실제로 체감하고 있는 것보다 주민들이 발전소를 훨씬 더 안전하게 지각하고 있을 것이라고 착각하고 있는 것으로 나타났다. 이 결과의 시사점 및 후속 연구에 대해 논의하였다.

  • PDF

입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터 (General Radiography Imaging Usage and Effective Dose of Inpatients: Based on Data from Inpatients in 2018)

  • 길종원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권2호
    • /
    • pp.107-116
    • /
    • 2024
  • In this study, we analyzed the use of general radiography imaging and effective dose in inpatients. Our aim is to help reduce national medical radiation exposure doses and develop rational health-care financial policies. The effective dose for each general radiography was calculated using the ALARA-GR program for 53 types (total: 260 codes) general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2018 inpatient patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was analyzed. 89.00% of inpatients undergo general radiography imaging at least once, with an average of 12.63 scans per person and an effective dose of 1.00 mSv. Those who received support from Medical Aid showed a higher value compared to those who were insured by National Health Insurance, with 17.39 cases and 1.43 mSv (p<.001). Chest had the highest usage rate at 23.12% for general radiography imaging, while L-spine had the highest effective dose at 24.53%. It is estimated that 420 inpatients patients undergo 121 to 820 general radiography imaging procedures per year, and 233 inpatients are estimated to have an annual effective dose of >20.00~58.25 mSv. Rational use of health-care finances and the practice of medical radiation safety management are essential for the well-being of individuals, the enhancement of quality of life, and the improvement of health-care quality.

Short and Effective Reset Method for AC PDPs

  • Kim, Joon-Yub;Lee, In-Moo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.241-245
    • /
    • 2006
  • Reset is necessary for effective addressing in AC PDPs, but reset takes considerable time and produces background luminance. A reset method that takes less time but is effective for addressing is presented. Furthermore, this reset method produces almost negligible background luminance.

  • PDF

Effective Maritime Search and Rescue

  • Redfern, A.
    • 해양환경안전학회지
    • /
    • 제2권1호
    • /
    • pp.121-123
    • /
    • 1996
  • Technical developments, particularly in communications, increase the potential for effective maritime search and rescue(SAR). The paper identifies some of the questions those seeking to proveid effective SAR service should ask, and outlines possible answers.

  • PDF

고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정 (Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy)

  • 윤재식;이재곤;이기현;임광석;최학기;이상미
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.98-103
    • /
    • 2014
  • 갑상선 분화암 환자의 방사선 치료에서 I-131의 유효반감기는 환자에게 투여하는 양의 계산뿐만 아니라 환자의 격리 입원기간의 결정, 환자로부터 가족들이 받게 되는 선량을 계산하는데 유용한 값이다. 하지만 이 값은 물리적반감기와는 달리 실측을 해야만 얻을 수 있어 입원 격리중인 환자에게 계측하기가 기술적으로 어려운 문제가 있다. Dual time I-131 whole body scan의 초기촬영과 지연촬영 사이의 체내잔류방사능량을 이용하여 전신과 갑상선에 유효반감기를 추정해 보았다. 또한 혈중 크레아티닌 농도, GFR, 투여량이 유효반감기와 상관관계가 있는지 알아보았다. 유효반감기 측정을 위해 전신에 체내잔류방사능량과 갑상선의 잔류방사능량을 측정하기 위해 환자의 전신을 흥미영역으로 설정한 후 배후방사능을 보정하여 전신의 체내잔류방사능량을 획득하였고, 갑상선 부위에 ROI를 설정한 후 배후 방사능을 보정하여 갑상선의 잔류방사능량을 획득하였다. 초기영상과 지연영상의 측정값 사이의 비율을 계산하여 전신과 갑상선의 유효반감기를 구하였다. 또한 유효반감기와 GFR, 혈중크레아티닌 농도, I-131 투여량과의 상관관계를 분석하였다. 전신의 체내잔류방사능량을 측정한 값의 유효반감기는 $17.06{\pm}5.50$시간으로 나타났고 갑상선의 잔류방사능량을 측정한 값의 유효반감기는 $17.22{\pm}5.41$시간으로 나타났으며 두 유효반감기는 유의한 차이를 보이지 않았다(P=0.887). GFR 값이 올라갈수록 전신의 유효반감기(r=-0.407, P=0.003)와 갑상선 유효반감기(r=-0.473, P=0.001) 모두 유의하게 감소하였으며 혈중크레아티닌 농도가 올라갈수록 전신의 유효반감기(r=0.309, P=0.029)와 갑상선 유효반감기(r=0.371, P=0.008) 모두 유의하게 증가하였다. 투여량은 두유효반감기와 상관관계를 보이지 않았다. 본 연구를 통해 고용량 방사성요오드 치료환자 입원기간의 최적화 연구와 기존 유효반감기를 구하기 위해 종사자의 피폭 및 복잡성을 보완하여 간편하게 측정을 할 수 있을 것이라 생각한다. 또한 분석된 갑상선의 유효반감기를 적용한 MIRD schema의 내부피폭선량 평가 연구에도 활용할 수 있을 것으로 사료된다.

  • PDF

효과적인 수학 교수를 위한 교사 지식 기반 영역과 수학적 지식 구조 (Teachers' Knowledge Base and The Structure of Mathematical Knowledge for Effective Mathematics Teaching)

  • 김영옥
    • 한국학교수학회논문집
    • /
    • 제11권4호
    • /
    • pp.595-608
    • /
    • 2008
  • 본 연구는 효과적인 수한 괴수(teaching)를 위해 괴사들이 갖추어야 할 지식 기반영역들을 소개하고, 지식 기반 영역 중에서도 가장 핵심 영역인 수학적 지식에 대한 다양한 정의와 구조에 관한 모델을 소개하고자 한다. 이를 통해, 본 연구는 교사지식 영역에 대한 전반적인 이해를 제공 할 뿐만 아니라, 수학적 지식에 대한 구체적이고 이론적인 틀을 제공하고자 한다.

  • PDF

Statistical Model of Effective Impact Speed based on Vehicle Damages in Case of Rear-End Collisions

  • Kang, Sung-Mo;Kim, Joo-Hwan
    • Journal of the Korean Data and Information Science Society
    • /
    • 제19권2호
    • /
    • pp.463-473
    • /
    • 2008
  • In this study, we measure damage depth and calculate effective impact speed in case of rear-end collision using real car insurance data. We study the relationship between demage depth and effective impact speed, and present statistical model for these two variables. In our real data study, 3-degree polynomial equation model is better fit to effective impact speed and demage depth than the simple linear model that are estimated in previous other studies. Damage depth is a major factor to see the extent of impact in a car collision, and by using this equation, it is possible to evaluate the severity of driver's injury.

  • PDF