• Title/Summary/Keyword: Effect zone

Search Result 2,548, Processing Time 0.033 seconds

Characteristics for Effects of Co2 Addition to Oxygen-Enriched Combustion (산소부화연소에서 Co2 첨가에 대한 연소 특성)

  • Kim, Han-Seok;Kim, Ho-Keun;Ahn, Kook-Young;Kim, Yong-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.1
    • /
    • pp.9-15
    • /
    • 2004
  • $CO_2$ is a well-known green house gas as well as the major source of global warming. Many researchers have studied to reduce $CO_2$ emission in combustion processes. Among the method for reducing $CO_2$ emission, oxygen-enriched combustion has been proposed. Because its adiabatic flame temperature is relatively too high, existing facilities must be changed or the flame temperature in the combustion zone should be reduced. The combustion characteristics, composition in the flame zone, temperature profile and emission gases were investigated experimentally for the various oxygen-enriched ratios(OER) by the addition of $CO_2$, under constant $O_2$ flow rate. Results showed that the reaction zone was quenched and broadened as the addition of $CO_2$ was increased. The emission of NOx in flue gas was decreased as decreasing temperature in reaction zone. It was also shown that the reaction was delayed by the cooling effect. As the addition of $CO_2$ was increased, the composition of CO in the flame zone was increased due to the increase of reaction rate by increasing mixing effect of oxidant/fuel at OER=0%, but the composition of CO was decreased by quenching effect at OER=50% and 100%.

Effect of Humidity on the Hydrogen Embrittlement of STS 444 Weld Zone for Boiler (보일러용 STS 444재 용접부의 수소취성에 미치는습기의 영향)

  • LIM, Uh-Joh;Choe, Byung-il;Yun, Byoung-Du
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.18 no.1
    • /
    • pp.58-64
    • /
    • 2006
  • In order to examine the effect of humidity on hydrogen embrittlement of STS 444 weld zone for boiler with dry and wet welding conditions, this paper was carried out the accelerated hydrogen osmosis test and the electrochemical Tafel polarization test. In 0.5M $H_2SO_4$ + 0.01M $As_20_3$ solution, this test is added to load of $1400kg/cm^2$ together with hydrogen osmosis by current of $50 {mA/cm^2}$ for 60 min.. The electrochemical Tafel polarization test was carried out in 0.5M $H_2SO_4$ + 0.01M $As_20_3$ solution. Therefore, the effect of humidity on hydrogen embrittlement of STS 444 was considered. The main results are as following: On the basis of hydrogen embrittlement mechanism, that is, integrated electrochemical polarization characteristics with the established mechanism of hydrogen embrittlement, the reduction rate of corrosion current density of weld zone in the wet weld condition is larger than in the dry condition. We can nondestructively predict the degree of hydrogen embrittlement of STS 444 weld zone for boiler through the reduction rate of electrochemical corrosion current density.

Comparative Study Before and After Washing Face with CCIS CP Soap (율피 저온숙성비누의 세안전·후 비교연구)

  • Koo, Jin Suk
    • The Korea Journal of Herbology
    • /
    • v.37 no.6
    • /
    • pp.53-59
    • /
    • 2022
  • Objectives : Cleanser is the most basic tools used in daily skin care. I made a cold process soap using Castanea crenata inner shell (CCIS). I'd like to study the effect of face wash using CCIS cold process (CP) soap on the skin. Methods : The same water and towel were used at the same place in order to examine the skin change state immediately before and after washing face. The skin test was performed before and after 10 minutes washing the face in order to remove these external environmental factors, such as lifestyle, alcohol, tobacco, and stress etc. As a control group, the cases of washing with water and foam cleanser (F/C), which is a popular commercial product, were set. Three cases were compared and analyzed. Results : In the case of water washing, there was a significant decrease in oil (U-zone) but that was not good effect. In the case of F/C and CCIS washing, there were significant decrease in oil (T-zone), pores and pigmentation, but the significance was bigger in CCIS washing. In the case of pores, there was a significant decrease in all three cases. Conclusion : In the case of F/C and CCIS washing, it showed the effect of reducing T-zone oil, pores and pigmentation. But the significance was greater in CCIS case than in F/C case. CCIS cp soap is considered as a form of face wash that is suitable for skin care.

The Experimental Studies on Anti-bacterial Effect of Tangpo-san on Three species of causative bacteria of Keratitis (탕포산(湯泡散)이 삼종(三種)의 각막염(角膜炎) 유발균들에 미치는 영향)

  • Kang, Sung-Goo;Yoo, Jin-Gon;Choi, Kwan-Ho;Seo, Hyung-Sik
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • This experimental study was performed to investigate the effect of herbal eye drops, Tangpo-san and Coptidis rhizoma on Staphylococcus aureus, Staphylococcus epidermidis and Pseudomonas aeruginosa keratitis. The following results were obtained by using Minimum inhibition Concentration(MIC) and inhibition Zone. 1. MIC on Staphylococcus aureus in Tangpo-san was 100%, in Coptidis rhizoma was 100% and in Cravit was 0.1% 2. MIC on Staphylococcus epidermidis in Tangpo-san was 100%, in Coptidis rhizoma was 10% and in Cravit was 0.1%. 3. MIC on Pseudomonas aeruginosa in Tangpo-san, Coptidis rhizoma was not showing and in Cravit was 0.1%. 4. The size of inhibition zone on Staphylococcus aureus for Tangpo-san was 13.3mm in $50{\mu}{\ell}$, for Coptidis rhizoma was 26mm in $50{\mu}{\ell}$ and for Cravit was 31mm in $50{\mu}{\ell}$, showing the highest antibacterial effect. 5. The size of inhibition zone on Staphylococcus epidermidis for Tangpo-san was 16mm in $50{\mu}{\ell}$, for Coptidis rhizoma was 25mm in $40{\mu}{\ell}$ and for Cravit was 34mm in $50{\mu}{\ell}$, showing the highest antibacterial effect. 6. The size of inhibition zone on Pseudomonas aeruginosa for Tangpo-san, Coptidis rhizoma was not and for Cravit was 24.7mm in $50{\mu}l$, showing the antibacterial effect. In addition, the results shows that the herbal eye drops, Tangpo-san and Coptidis rhizoma can be used to cure Staphylococcus aureus, Staphylococcus epidermidis keratitis and if further study is performed, the use of herbal eye drops will be valuable and beneficial in the clinical medicines.

  • PDF

Characteristics Comparison of Prepared Films According to Influence of Adsorption Inhibitor in the Condition of Deposition (PVD증착용 흡착인히비터의 영향에 따른 제작막의 특성 비교)

  • 이찬식;윤용섭;권식철;김기준;이명훈
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.67-67
    • /
    • 2001
  • The structure zone model has been used to provide an overview of the relationship between the microstructure of the films deposited by PVD and the most prominent deposition condition.s. B.AMovchan and AV.Demchishin have proposed it firstls such model. They concluded that the general features of the resulting structures could be correlated into three zones depending on $T/T_m$. Here T m is the melting point of the coating material and T is the substrate temperature in kelvines. Zone 1 ($T/Tm_) is dominated by tapered macrograins with domed tops, zone 2 ($O.3) by columnar grains with denser boundaries and zone 3 ($T/T_m>O.5$) by equiaxed grains formed by recrystallization. J.AThomton has extended this model to include the effect of the sputtering gas pressure and found a fourth zone termed zone T(transition zone) consisting of a dense array of poorly defined fibrous grains. R.Messier found that the zone I-T boundary (fourth zone of Thorton) varies in a fashion similar to the film bias potential as a function of gas pressure. However, there has not nearly enough model for explaining the change in morphology with crystal orientation of the films. The structure zone model only provide an information about the morphology of the deposited film. In general, the nucleation and growth mechanism for granular and fine structure of the deposited films are very complex in an PVD technique because the morphology and orientation depend not only on the substrate temperature but also on the energy of deposition of the atoms or ions, the kinetic mechanism between metal atoms and argon or nitrogen gas, and even on the presence of impurities. In order to clarify these relationship, AI and Mg thin films were prepared on SPCC steel substrates by PVD techniques. The influence of gas pressures and bias voltages on their crystal orientation and morphology of the prepared films were investigated by SEM and XRD, respectively. And the effect of crystal orientation and morphology of the prepared films on corrosion resistance was estimated by measuring polarization curves in 3% NaCI solution.

  • PDF

Variation of Notch Shape on the Delamination Zone Behavior in Al/AFRP Laminates (노치형태 변화에 따른 Al/AFRP 적층재의 층간분리거동)

  • Song, Sam-Hong;Kim, Cheol-Woong
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.278-285
    • /
    • 2001
  • Aluminum/Aramid Fiber Reinforced Plastic(Al/AFRP) laminates are applied to the fuselage-wing intersection. The main objective of this study was to evaluate the delamination zone behavior of Al/AFRP with a saw-cut and circular hole using average stress criterion and the effect of notch geometry. Mechanical tests were carried out to determine the cyclic-bending moment and delamination zone observed ultrasonic C-scan pictures. In case of Al/AFRP containing saw-cut specimen, the shape and size of the delamination zone formed along the fatigue crack. However, in case of Al/AFRP containing circular hole specimen, the shape and size of delamination zone formed two types. first type, delamination zone formed along the fatigue crack. Second type, not observed fatigue crack. Therefore, delamination zone was formed dependently of the circular hole shape.

  • PDF

Effect of spatial characteristics of a weak zone on tunnel deformation behavior

  • Yoo, Chungsik
    • Geomechanics and Engineering
    • /
    • v.11 no.1
    • /
    • pp.41-58
    • /
    • 2016
  • This paper focuses on the deformation behavior of tunnels crossing a weak zone in conventional tunneling. A three-dimensional finite element model was adopted that allows realistic modeling of the tunnel excavation and the support installation. Using the 3D FE model, a parametric study was conducted on a number of tunneling cases with emphasis on the spatial characteristics of the weak zone such as the strike and dip angle, and on the initial stress state. The results of the analyses were thoroughly examined so that the three-dimensional tunnel displacements at the tunnel crown and the sidewalls can be related to the spatial characteristic of the weak zone as well as the initial stress state. The results indicate that the effectiveness of the absolute displacement monitoring data as early warning indicators depends strongly on the spatial characteristics of the weak zone. It is also shown that proper interpretation of the absolute monitoring data can provide not only early warning for a weak zone outside the excavation area but also information on the orientation and the extent of the weak zone. Practical implications of the findings are discussed.

EFFECT OF TOP END CONDITION OF FUEL BED CONTAINER ON DOWNWARD SMOLDER SPREAD

  • Sato, Kenji;Sakai, Yasuhiro
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.146-153
    • /
    • 1997
  • An experimental study was performed of natural-convection downward smolder spread across a sawdust bed peripherally enclosed with an insulating container, to examine the effect of the open- ing condition at the top end on downward smolder spread. Experiments were conducted by using relatively coarse sawdust and 25-cm-long cylindrical container The variations of temperature profiles along the bed axis with time were determined far different opening conditions and were com-pared with those in smolder spread from open top to open bottom. It was shown that the smolder zone initiated from open top toward closed bottom penetrates the bed with keeping high peak temperature like the case of open top to open bottom spread, although mean spread rate is smaller. This indicates that the downward smolder zone can be sustained stably if sufficient air or oxygen Is supplied from the back of it by natural convection even if upward draft entering from the bottom of the bed is absent. When the top end was partially closed by mounting a cover after stable smolder spread had begun from open top toward open bottom, the temperature at the peak decreased more than 200 K and the smolder zone became to spread with thickening residue. In this case, the shape of temperature profiles continuously changed or decayed until end-effect at the open bottom end enhanced the reaction. The temperature at the shrunk peak, free from the end-effect, was almost identical with the temperature at the exothermic oxidative-degradation zone in smolder spread from open top to open bottom. from these results, it can be inferred for natural-convection downward smolder spread that the oxidation reaction of the char is very sensitive to the oxygen supply by natural convection in the space above the smolder zone, and that the top end opening condition strongly alters the completeness of reactions, structure, and behavior of the smolder zone.

  • PDF