Design and Experiment of V-LTSA with Microstrip-to-Coplanar Strip Line Feed (Microstrip-to-Coplanar Strip Line 급전구조를 갖는 V-LTSA 의 설계 및 실험)

  • 김혜리;김남현박노준강영진
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.395-398
    • /
    • 1998
  • In this paper, the design, fabrication, and experiments of linearly tapered slot antenna(LTSA) with uniplanar microstrip-to-coplanar strip(CPS) line transitions are presented. The effect of reducing and increasing with taper width G teper longth 1, and opening angle are also mesured at 10 GHz.

  • PDF

New FE On-line Model (실시간 압연하중 및 압연동력 예측 모델의 개선)

  • 김영환
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.04a
    • /
    • pp.52-55
    • /
    • 2000
  • Investigated via a series of finite element process simulation is the effect of diverse process variables on some selected non-dimensional parameters characterizing the strip in hot strip rolling. Then on the basis of these parameters an on-line model is derived for the precise prediction of roll and roll power. The prediction accuracy of the proposed model is examined through comparison with predictions from a finite element process model.

  • PDF

Stress Evaluation by the Measurement of Acoustoelastic Effect Using a Line-Foucus Acoustic Microscope (선 집속 초음파 현미경을 이용한 음탄성효과 측정에 의한 응력 평가)

  • Kim, J.O.;Lee, Y.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.119-126
    • /
    • 1997
  • The relationship between the applied stresses and the change of elastic wave velocity has been established based on the acoustoelasticity theory. The non-uniform stress field in a loaded specimen has been evaluated from the surface acoustic wave velocity measured by the line-focus acoustic microscopy with the acoustoelastic constants obtained form a calibration test. The evaluated stresses are in good agreement with the results calculated by finite element method.

  • PDF

Salinity Determination Using Temperature Compensated On-Line Refractometer (온도보상형 온라인 굴절계를 이용한 해수의 염도 측정)

  • 최한욱;김영한
    • Journal of Korean Port Research
    • /
    • v.15 no.1
    • /
    • pp.99-105
    • /
    • 2001
  • An on-line refractrometer made of easily obtainable materials is built to determine the salinity and temperature of sea water, and its performance is examined by applying the refractometer to known salt solution. Since refractive index and temperature are measured simultaneously, it is possible to compensate the effect of temperature for accurate measurement. The outcome of salinity measurement for the different concentrations of salt solution indicates that the device is suitable for the salinity measurement by yielding stable and reproducible reading.

  • PDF

A study of the harmonics evaluation in the test track of Korea High Speed Rail (경부고속철도 시험선구 고조파 예측에 관한 연구)

  • 김길상;오광해;권삼영;이태형
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.241-248
    • /
    • 1998
  • The purpose of this study is to evaluate the harmonics generated from Korea High Speed Rail's trainset and to analyze the effect on the KEPCO power system. This study focuses on the test track of the high speed rail and analyzes 154㎸ transmission line, scott transformer, autotransformer and 27,5㎸ line. The trainset is modeled as a harmonic source attached to the catenary line of the test track. Then, harmonic distortion is calculated. This distortion is compared with the KEPCO's regulations in relation to harmonic.

  • PDF

Noise Reduction of a Small D/C Motor Using 6 Sigma Process (6 시그마 프로세스를 이용한 소형 직류 모터의 소음 절감)

  • 차원준;최연선
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.7
    • /
    • pp.532-538
    • /
    • 2003
  • This paper studies on the noise reduction for a small automobile DC Motor (a window motor) using the 6 sigma process. The application of 6 sigma process suggested reliable and valuable statistical data for the quality of the DC motor at the production line. In the measurement step in 6 sigma process. the FMEA(failure mode effect analysis) were used for the detection of noise sources. The application of 6 sigma Process gave not only the improving method for the quality of the DC motor but also the confidence of improvement Itself since it was done on the basis of the test results for a number of DC motors at the production line. Consequently the 6 sigma process was proved very effective for the noise reduction at the production line.

A Study on the Effect of a Stabilization Error of the Line-Of-Sight Stabilization System according to the Isolation Properties (방진성능에 따른 시선 안정화 장치의 안정화오차 영향성 검토)

  • Park, Jae-Hoon;Park, Jong-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.186-190
    • /
    • 2011
  • The Line-Of-Sight stabilization system is designed to minimize the error of Line-Of-Sight under the disturbing circumstances. In order to control this system more accurately and reduce the level of the disturbance, adding an isolator is mostly considered. However, it is difficult to predict the exact the behavior of the isolator and the effect of a stabilization Error. Therefore, the simulation model of the control system using co-simulation with Adams and matlab simulink is presented and the effects of the isolation properties are reviewed.

  • PDF

Analysis of Lightning Overvoltage on the Combined Power Transmission Line and Actuation of Arrester (혼합송전계통에서 뇌과전압해석 및 피뢰기 동작특성 검토)

  • Kim, Nam-Yoel;Kim, Kyoung-Ho;Lee, Jong-Beom;Cho, Han-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.491-493
    • /
    • 2001
  • This paper describes the effect of lightning current on combination transmission line. In the paper, an lightning current which can generate 2/80[${\mu}s$]. 20[kA] - 40[kA] waveform is modeled in ATPDraw. The lightning current invaded to the overhead power transmission line propagates to the underground power cable. The simulation was performed to analyze the effect of arrester location and overvoltage occurred in power cable.

  • PDF

Design of Crosstalk Compensation Circuit in TFT-LCDs (박막트랜지스터 액정표시소자의 화소간섭 보상회로설계)

  • 정윤철;박종철;김이섭
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.11
    • /
    • pp.1374-1382
    • /
    • 1995
  • In TFT-LCDs, as the display size area becomes larger, and the resolution higher, we have to consider the image degradation effects due to the incorporation of the TFT-LCD parameters such as the data-line resistance, the common electrode resistance, the data-line to common parasitic capacitance, and the output characteristics of driver ICs. One of the degradation effects is crosstalk resulting from the coupling between the source bus-line and common electrode. Since a source signal which represents a large number of display data is supposed to vary frequently, the common signal level is affected through the coupling effect, resulting in the degradation of nearby pixel drive signals. Therefore, we proposed a method to compensate for this source-common electrode coupling effect, we also designed and experimented the feasibility of our crosstalk compensation circuit in the actual TFT-LCD. We saw that the newly designed compensation circuit greatly reduced the crosstalk in display pattern image.

  • PDF

Fault Location Algorithms for the Line to Ground Fault of Parallel-Circuit Line in Power Systems (전력계통 송배전선로 2회선 1선지락사고 고장거리 검출 알고리즘)

  • 최면송;이승재;강상희;이한웅
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.1
    • /
    • pp.29-35
    • /
    • 2003
  • This paper presents a fault location algorithm when there are parallel circuits in power system networks. In transmission networks, a fault location method using the distribution factor of fault currents is introduced and in distribution networks a method using direct 3-phase circuit analysis is developed, because the distribution networks are unbalanced. The effect of parallel circuits in fault location is studied in this paper. The effect is important for the range of protecting zones of distance relay in transmission networks and fault location in distribution networks. The result of developed fault location algorithm shows high accuracy in the simulation that using the EMTP.