• 제목/요약/키워드: Eddy Current Diagnosis

검색결과 19건 처리시간 0.024초

와전류 기법을 이용한 가공전력선 열화 진단 (Degradation Diagnosis of Overhead Power Lines Using Eddy Current Technology)

  • 김충혁;김탁용;오용철;최운식;조춘남
    • 한국전기전자재료학회논문지
    • /
    • 제27권5호
    • /
    • pp.322-327
    • /
    • 2014
  • Internal corrosion of the distribution line can be detected in order to develop techniques of non-destructive inspection methods that operate only on the metal track eddy current diagnosis is possible by applying the technique investigated. Sensor for the production of a finite element method modeled by using an eddy current sensor, a distribution line by using an accelerated aging samples of sodium hydroxide was prepared. Sheathed cables for internal corrosion studies detected using an eddy current sensor is considered to be possible.

전선 부식에 따른 와전류특성 조사 (A Study of Eddy Current Characteristics which Follows in the Corrosion of Power line)

  • 오용철;정한석;이재봉;임주혁;손기정;김진사;김충혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.77-77
    • /
    • 2010
  • We used eddy current sensor for diagnosis of power line. The power line according to the cross section has 6~18 element wires. The corrosion of power line was made by sodium hydroxide. The corrosion time of power line was from 18 hours to 27 hours. We obtained physical characteristics from tensile and torsion tests of power line. The eddy current Characteristics of power line according to the corrosion appeared change of amplitude 200 ~ 800 mV.

  • PDF

Comparison of ECT Probes in Diagnosis of Defects

  • Mun, Ho-Young;Kim, Chang-Eob
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.190-196
    • /
    • 2014
  • In this paper, the characteristics of a defective elliptical aluminum plate are analyzed by three different eddy current testing probes; T/R, T/T, and Impedance probes. The analysis was done by 3D finite element method, and the impedance change of real and imaginary voltage values were analyzed.

와전류 탐상시험을 이용한 전력선의 절연상태 진단 (A Diagnosis of Insulated State using Eddy Current Testing in Power Line)

  • 박건호
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2018년도 제58차 하계학술대회논문집 26권2호
    • /
    • pp.177-178
    • /
    • 2018
  • 본 논문에서는 와전류 탐상시험을 이용하여 전력선의 절연상태 진단을 수행하였다. 전력선은 6~18 가닥의 선으로 이루어져 있는데 절연상태 변화를 위해 수산화나트륨으로 전력선의 부식을 유도하였으며, 18~27 시간으로 부식시간을 설정하여 시편을 구분하였다. 전력선의 인장력시험, 뒤틀림시험, 전자주사현미경 등을 통하여 물리적 특성을 검토하였으며, 또한 200~800[mV]의 전압에서 부식에 따른 와전류 특성을 조사하였다.

  • PDF

22.9kV 배전선로 절연전선의 부식 검출 시스템 개발에 대한 연구 (A Study on the Development of Corrosion Detecting System for 22.9 kV Distribution Power Line Insulation Cable)

  • 김용준;오용철;이건영
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1410-1416
    • /
    • 2011
  • A corrosion detecting system for 22.9 kV distribution power line insulation cable, which can travel autonomously along the live line, is proposed. Eddy current test method is employed to detect the corrosion, and the system developed here is capable of detecting internal corrosion of a ACSR-OC. Somewhat details of the electrical and mechanical mechanism of the system and traveling algorithm are introduced. Experimental results applied to the sample cables having artificial corrosion and the operating distribution lines are provided. From the result, we confirmed that the system is useful for detecting internal corrosion of a ACSR, and is expected to be a new non-destructive testing equipment in the area of diagnosis for the distribution power line.

자동차용 볼트의 검사를 위한 시뮬레이션에 기반한 ECT 센서 설계 및 실험적특성 (Experimental Approach and Simulation-Based Design of Eddy Current Sensors for Inspection of Vehicular Bolts)

  • 임광희;이슬기;김학준;송성진;우용득;나승우;이형호
    • 한국생산제조학회지
    • /
    • 제24권3호
    • /
    • pp.294-301
    • /
    • 2015
  • Oil filters for vehicular parts are used under high and low temperatures as the engine is cooled, and defects can be generated with repeated changes in the operating environment and with changes in the shape, such as very high internal losses for the bolts. Visually checking for defects inside a bolt is impossible. Nondestructive evaluation methods such as eddy current testing (ECT) are recommended as a more effective way to examine inside a bolt and detect surface defects in a short amount of time. In this study, the fit bobbin coil eddy current probe was applied to checking the bolts. The bolt parameters were calculated by using a COMSOL analysis program to obtain parameters for professional interior design and fault diagnosis.

전자기 수치해석을 이용한 표준보정시험편의 배열형 와전류 탐촉자 신호 특성 해석 (Characteristic Analysis of Eddy Current Array Probe Signal in Combo Calibration Standard Tube Using Electromagnetic Numerical Analysis)

  • 김지호;이향범
    • 비파괴검사학회지
    • /
    • 제30권4호
    • /
    • pp.330-337
    • /
    • 2010
  • 본 논문은 원전 증기발생기(SG, steam generator) 세관의 정밀 진단을 위한 차세대 탐촉자인 배열형 와전류 탐촉자의 특성 해석에 대한 3차원 전자기 수치해석을 수행하였다. 다양한 결함 해석을 위해 ASME(American Society of Mechanical Engineers) 표준시험편과 X-probe combo 표준보정시험편(inline EXP/spiral groove combo standard)을 선정하여 탐상신호를 획득하고, 실제 실험 신호와 비교하여 결과의 타당성을 검증하였다. 표준 보정 시험편의 해석 결과를 바탕으로 원전 SG 세관에서 주로 발생하고 있는 pitting, SCC(stress corrosion cracking), multiple SCC, wear 결함에 대하여 탐상신호를 획득하였다. 해석 대상으로는 원자력발전소 SG 세관으로 사용하고 있는 Inconel 600 도체관을 사용하였고, 이때의 시험주파수는 300 kHz이다. 본 논문을 통하여 각각의 결함에 대한 신호 특성을 파악하여 배열형 와전류 탐촉자의 결함의 종류에 따른 신호 특성을 확인할 수 있었다. 본 논문의 결과는 배열형 와전류 탐촉자의 와전류 탐상 신호 평가시 도움이 될 것이다.

가공 배전선로 진단시스템을 위한 최적 센서 개발 (Development of Optimal Sensor for Diagnostic System in Overhead Distribution Power Lines)

  • 이경섭
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.670-675
    • /
    • 2015
  • Degradation diagnosis of cable is one of major issues for operation and maintenance in overhead distribution power lines. The diagnostic system for overhead power lines is composed of three parts in functional aspect - a travelling unit, a sensing unit and a communication unit. Among them, sensor detects the defects such as corrosion and disconnecting of power lines. Performance of sensor is very important, and besides, the size and structure of sensor is restricted for installation to small and lightweight diagnostic system. This paper suggests an optimal eddy current sensor best suit for small and lightweight diagnostic system in consideration of detecting performance, size and ease of installation and so on. Proposed sensor has been designed by Drum core structure and can be applied to the all domestic overhead power lines regardless of the cross-sectional areas. Also, it is showed that results of mock environmental test are satisfied.

와전류 센서를 이용한 케이블용 내부 열화 검출 방법 (Detecting Method of Internal Degradation for Cable using Finite Element Method)

  • 박건호
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2015년도 제51차 동계학술대회논문집 23권1호
    • /
    • pp.291-292
    • /
    • 2015
  • 와전류 탐상 기법을 이용하여 배전선로의 내부 열화를 검출하는 시스템을 개발할 수 있는데, 본 연구에서는 이를 위하여 유한요소법을 통한 시뮬레이션으로 와전류 센서의 기초 모델링을 구상한 후 실제 와전류 센서를 제작하여 가속 열화에 의한 센서 특성을 조사하였다.

  • PDF

22.9kV 배전선로 절연전선 검출용 와류탐상 센서 특성 연구 (A Study of Properties Eddy Current Sensor for 22.9kv Distribution Insulation Cable)

  • 오용철;김탁용;이경섭;정한석;유재식;양정권;이재봉;이건행;김종현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2140_2141
    • /
    • 2009
  • We used the eddy current sensor for a 22.9kV distribution power line insulation cable diagnosis. The insulation cable which is used in the 22.9kV distribution power line is having element wire from 6 to 18. Consequently, currently to ECT applications it has a limit in the distribution power line. We about under producing to apply in pick-up coil forms and the differential total coil form where becomes sum of zero in order to have. From measurement result, partial broken cable was confirmed 500 mV~980 mV changes from normal state.

  • PDF