• Title/Summary/Keyword: Economical Analysis

Search Result 1,906, Processing Time 0.032 seconds

Techno-Economic Analysis of Reversible Solid Oxide Fuel Cell System Couple with Waste Steam (폐스팀을 이용한 가역 고체산화물 연료전지의 기술적 경제적 해석)

  • GIAP, VAN-TIEN;LEE, YOUNG DUK;KIM, YOUNG SANG;AHN, KOOK YOUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.1
    • /
    • pp.21-28
    • /
    • 2019
  • Reversible solid oxide fuel cell (ReSOC) system was integrated with waste steam for electrical energy storage in distributed energy storage application. Waste steam was utilized as external heat in SOEC mode for higher hydrogen production efficiency. Three system configurations were analyzed to evaluate techno-economic performance. The first system is a simple configuration to minimize the cost of balance of plant. The second system is the more complicated configuration with heat recovery steam generator (HRSG). The third system is featured with HRSG and fuel recirculation by blower. Lumped models were used for system performance analyses. The ReSOC stack was characterized by applying area specific resistance value at fixed operating pressure and temperature. In economical assessment, the levelized costs of energy storage (LCOS) were calculated for three system configurations based on capital investment. The system lifetime was assumed 20 years with ReSOC stack replaced every 5 years, inflation rate of 2%, and capacity factor of 80%. The results showed that the exergy round-trip efficiency of system 1, 2, 3 were 47.9%, 48.8%, and 52.8% respectively. The high round-trip efficiency of third system compared to others is attributed to the remarkable reduction in steam requirement and hydrogen compression power owning to fuel recirculation. The result from economic calculation showed that the LCOS values of system 1, 2, 3 were 3.46 ¢/kWh, 3.43 ¢/kWh, and 3.14 ¢/kWh, respectively. Even though the systems 2 and 3 have expensive HRSG, they showed higher round-trip efficiencies and significant reduction in boiler and hydrogen compressor cost.

A Study on the Multi-dimensional Greening Preferential Factors for Securing Green Spaces in Cities (도시 녹지 공간 확보를 위한 건물의 입체녹화 선호요인에 관한 연구)

  • CHOI, Jae-Hyun;LEE, Myeong-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.521-530
    • /
    • 2019
  • With a view to respond to urban climate change issues and improve the urban environment in a qualitative manner, the strategy of multi-dimensional greening of the traditional markets in the City of Seoul to secure the multi-dimensional green spaces can result in a significant effect in terms of landscaping, environment, and spatial aspect. The purpose of this study is to examine the elements of multi-dimensional greening for the multi-dimensional greening of buildings in order to enhance the greening function within urban phenomena and, with this, establish the criteria for success introduction of multi-dimensional greening and its qualitative expansion. For this, a total of 569 consumers of traditional markets have been interviewed, and the data from their questionnaires were analyzed through SPSS and AMOS software. The result of the analysis showed that the elements of the multi-dimensional greening of traditional markets, such as the economical, physical, functional, visual, and facility aspects all affected the consumer expectation in a positive manner. Also, depending on the gender of the customers of traditional markets, the ecological aspect among the elements of multi-dimensional greening had a significant difference. And, by the age, the functional, physical, and visual aspects of the elements of multi-dimensional greening showed a significant different. And, the expectation on the multidimensional greening of traditional markets also showed a statistically significant difference. By the level of education, there were significant differences in terms of the physical and visual aspects of the multi-dimensional greening elements. And, the level of expectation on the multidimensional greening also differed significantly.

The Influence of Discrimination Experience on Life Satisfaction of the Employed Hearing-Impaired - Focusing on the Mediating Effects of Self-Esteem - (취업한 청각장애인의 차별경험이 생활만족도에 미치는 영향 -자아존중감의 매개효과-)

  • Lee, Jun Sang;Park, Ae sun
    • 재활복지
    • /
    • v.21 no.1
    • /
    • pp.97-119
    • /
    • 2017
  • The objective of this study is to understand the influence of discrimination experience on life satisfaction of the employed hearing-impaired, and also to verify the mediating effects of self-esteem on relations between discrimination experience and life satisfaction. To achieve this objective, the data of the 8th Panel Survey of Employment for the Disabled was used, and then the extracted data of 234 employed hearing-impaired persons was used for analysis. The results of this study are like below. First, discrimination experience showed negative(-) relations with self-esteem and life satisfaction while self-esteem showed positive(+) relations with life satisfaction. Second, when the perception of discrimination experience was low, the life satisfaction was high. Third, the mediating effects of self-esteem were verified on relations between discrimination experience and life satisfaction. Marital status, health, social-economical position has effected on life satisfaction. Based on such results of the study, suggestions were made to increase life satisfaction of the hearing-impaired.

Power-efficiency Analysis of the MIMO-VLC System considering Dimming Control (조광제어를 고려한 MIMO-VLC 시스템의 전력 효율 분석)

  • Kim, Yong-Won;Lee, Byung-Jin;Lee, Byung-Hoon;Lee, Min-Jung;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.169-180
    • /
    • 2018
  • White light-emitting diodes (LEDs) are more economical than fluorescent lights, and provide high brightness, a high lifetime expectancy, and greater durability. As LEDs are closely connected with people's daily lives, dimming control of LED is an important component in providing energy savings and improving quality of life. In visible light communications systems using these LEDs, multiple input multiple output (MIMO) technology has attracted a lot of attention, in that it can attain the channel capacity in proportion to the number of antennas. This paper analyzes the power performance of three kinds of modulation in visible light communications (VLC) systems applied space-time block code (STBC) techniques. The modulation schemes are return-to-zero on-off keying (RZ-OOK), variable pulse position modulation (VPPM), and overlapping pulse position modulation (OPPM), and dimming control was applied. The power requirements and power consumption were used as metrics to compare the power efficiency in $2{\times}2$ STBC-VLC environments under the three kinds of modulation. We confirm that dimming control affects the communications performance of each modulation scheme. VPPM showed greater consumption among the three modulations, and OPPM showed energy savings comparable to VPPM.

Investigation for the deformation behavior of the precast arch structure in the open-cut tunnel (개착식 터널 프리캐스트 아치 구조물의 변형 거동 연구)

  • Kim, Hak Joon;Lee, Gyu-Phil;Lim, Chul Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.93-113
    • /
    • 2019
  • The behavior of the 3 hinged precast arch structure was investigated by comparing field measurements with numerical analyses performed for precast lining arch structures, which are widely used for the open-cut tunnel. According to the field measurements, the maximum vertical displacement occurred at the crown with upward displacements during the backfilling up to the crown of the arch and downward displacements at the backfill height above the crown. The final crown displacement was 19 mm upward from the original position. The horizontal displacement at the sidewall, which had a maximum horizontal displacement, occurred inward of the arch when compacting the backfill up to the crown and returned to the original position after completing the backfill construction. According to the analysis of displacement measurements, economical design is expected to be possible for precast arch structures compared to rigid concrete structures due to ground-structure interactions. Duncan model gave good results for the estimation of displacements and deformed shape of the tunnel according to the numerical analyses comparing with field measurements. The earth pressure coefficients calculated from the numerical analyses were 0.4 and 0.7 for the left and the right side of the tunnel respectively, which are agreed well with the eccentric load acting on the tunnel due to topographical condition and actual field measurements.

Analysis and cause of defects in reinforced cement concrete lining on NATM tunnel based on the Precise Inspection for Safety and Diagnosis - Part I (정밀안전진단 결과를 활용한 NATM (철근)의 라이닝 결함 종류별 발생원인 및 분석 - Part I)

  • Choo, Jinho;Lee, Inmo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.1-29
    • /
    • 2019
  • Related to the previous paper on the typical crack pattern of tunnel lining with NATM, the characteristic defects in reinforced cement concrete lining of NATM tunnel have analyzed with the precise inspection with safety and diagnosis (PISD) by KISTEC. Depending on the reinforcing materials, steel rebar, steel fiber, and glass fiber have been implemented to reinforcing lining in various NATM tunnel constructions. Reinforcing lining with rebar are prevailed on NATM tunnel to countermeasure the weak geological circumstances, to pursuit the economical tunnel sections, and to resist the risk of tunnel deterioration. By the special act on the safety control of public facilities, the reinforced NATM tunnels for more than 1 km length are scrutinized closely to characterize defects; crack, reinforcement exposure, and lack of lining. Crack resistance by reinforcing is shown in comparison with the normalized crack to the length of tunnel. Typical exposed reinforcements in lining have exemplified with various sections. The lack of lining due to the mal-construction, spalling, fire, earthquake and leaching has been analyzed. The cause and mechanism with the field inspections and other studies has also been verified. Detailed cases are selected by the above concerns as well as the basic information from FMS (Facilities Management System). Likewise the previous paper, this study provides specialized defects in reinforced lining of NATM and it can be widely used in spreading the essential technics and reporting skills. Furthermore, it would be advised and amended for the detail guideline of Safety Diagnosis and PISD (tunnel).

Study on the LNG Vaporization Characteristics of Open Rack Vaporizer(ORV) with Two-way Seawater Supplying System (해수 2단 공급에 따른 해수식 기화기(ORV)의 LNG 기화 특성 연구)

  • Kim, Nam-Kug;Yun, Sang-Kook
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.41-46
    • /
    • 2019
  • LNG is supplying to consumers as gas phase vaporized by major seawater vaporizer, i.e.. open rack vaporizers. But as soon as the temperature of seawater drops below $5^{\circ}C$ in winter, the submerged evaporators should be operated and cause a lot of energy consumption because of their natural gas combustion. In order to reduce the consumption amount, in this study new two-way supplying method of seawater instead of the present one-way supplying system is introduced and analysed the technical possibilities and economical savings. The results showed that in case of the temperature of seawater becomes below $2.5^{\circ}C$, LNG can be evaporated using ORV without operating S MV. If this system is applied in Incheon LNG terminal, the energy saving reaches 11,770 Ton of LNG as 11,760 million won. By the analysis, the two-way supplying system of seawater in ORV can be the most effective method to be able to save huge amount of energy every year.

Preparation of Recombinant Human Epidermal Growth Factor by Hydroxylamine Cleavage (하이드록실아민 절단을 이용한 재조합 인간 상피세포 성장인자의 제조)

  • Kim, Sun-Ho;Lee, Woo-Yiel
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.542-549
    • /
    • 2021
  • The purpose of this study was to provide an economical and easy preparation method for recombinant human epidermal growth factor (rhEGF) without the need for an expensive enzyme to cleave the fusion part. However, the N-terminal fusion part is still useful for affinity chromatography. The hEGF is an important hormone in cell growth and proliferation in humans, and many studies on the expression and purification of this protein have been reported. In the present study, the hEGF gene was designed to be optimized with the E. coli codon usage preference and to contain Asn-Gly at the N-terminus of the protein. The gene was inserted into pRSET_A, an E. coli expression vector, and transformed into E. coli BL21 (DE3). The recombinant fusion protein was successfully co-expressed with pG-Tf2, a chaperone vector, in E. coli and purified by Ni-NTA column chromatography. The rhEGF was then released by hydroxylamine treatment and confirmed by SDS-PAGE. ELISA analysis showed that the activity of the free rhEGF was more than 92% similar to that of commercial EGF. The biological activity of the rhEGF was confirmed by a cell proliferation test with human skin fibroblasts.

An Analysis of the Composite Discharge Capacity Effect with GCP Method (GCP공법의 복합통수능 효과 분석)

  • Park, Minchul;Kwon, Hyukchan;Shin, Hyohee;Jang, Gisoo;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.37-46
    • /
    • 2011
  • An application frequency of vertical drainage method is increasing as an effective consolidation acceleration method. PBD method is most frequently used as a consolidation acceleration method in vertical drainage methods. PBD is economical and easy to operate but has some problems those are an environmental pollution and a decrease of a discharge capacity caused by bending of drainage materials when it is used in great depth. SCP method was frequently used because it's discharge capacity was good but now it is rarely used because of an increase of the material price because of an order imbalance. As the way to solve these problems, GCP method has been to the fore. For analyzing the effect of GCP method on the discharge capacity, three types of composite discharge capacity tests are done by using GCP, SCP and PBD respectively with the circle case, ${\phi}38{\times}h70cm$. On the contrary to this, GCP shows the worst discharge capacity for a decrease of the void ratio and the clogging phenomenon caused by increasing load. Also to figure out the clogging range of GCP, the clogging of GCP is checked in each load stage with a large case($1.0m{\times}0.5m{\times}1.1m$) which has clear acrylic front face. The diameter of GCP was 35cm and a clogging phenomenon occurred in 10% approximately. The result shows that the discharge capacity of GCP was given the lowest value for a decrease of the void ratio and the clogging phenomenon causing by increasing load. And the clogging phenomenon mostly occurred within 10% of GCP's diameter range.

Analysis of Climate and Topographical Factors of Economical Forests in Korea to Select the Restoration Safe Site of 5 Dominant Oak Species (참나무 5종의 생태 복원 적지 추정을 위한 경제림 육성단지의 기후와 입지 요인 분석)

  • Lee, Seung-Yeon;Kim, Eui-Joo;Lee, Eung-Pill;Cho, Kyu-Tae;Park, Jae-Hoon;Lee, Young-Keun;Chung, Sang-Hoon;Hong, Yong-Sik;Park, Jin-Hee;Choi, Seung-Se;Kim, Hae-Ran;You, Young-Han
    • Korean Journal of Ecology and Environment
    • /
    • v.53 no.4
    • /
    • pp.427-435
    • /
    • 2020
  • The most important thing to successfully restore an oak forest is finding suitable climatic conditions and topographic factors for the oak species to be introduced. In this study, in order to find suitable environmental conditions for the five dominant oak trees on the Korean Peninsula, we carried out analysing the information on the location of forest vegetation on the Korean Peninsula. The range of annual mean temperature of the five oak trees was narrow in the order of Q. mongolica (7.7~14.3℃), Q. variabilis (9.2~13.8℃), Q. acutissima (10.5~14.3℃), Q. serrata (11.4~13.7℃), Q. aliena (11.0~12.9℃). The range of annual precipitation of oaks was narrow in order of Q. mongolica (1072.7~1780.9 mm), Q. variablis (1066.6~1554.9 mm), Q. acustissima (1036.5~1504.8 mm), Q. serrata (1062.6~1504.7 mm). The range of altitude was in order of Q. mongolica (147~1388m), Q. serrata (93~950m), Q. variabilis(90~913m), Q. acustissima (60~516m), Q. aliena (55~465 m). The range of slope was in the order of Q. mongolica (8~56°), Q. variabilis(5~52°), Q. serrata (11~45°), Q. aliena (15~38°), Q. acustissima (16~37°). These results are considered to be very useful in the case of ecological restoration using deciduous oak trees on the Korean Peninsula.