• 제목/요약/키워드: Economic load dispatch

검색결과 71건 처리시간 0.038초

부하의 동특성을 고려한 화력발전기의 경제부하배분 앨고리즘에 관한 연구 (A study on the Algorithm for the Economic Dispatch of Thermal Units Considering Dynamic Characteristics of Load)

  • 송길영;박경수;최재석;박현신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.92-94
    • /
    • 1988
  • One of the recurring problems facing energy control center dispatchers each day is how to operate the system during the periods of high load pick up and fluctuation. This method reduces the problem to a forward - revised by backward - sequence of dispatch problem, with the generator Limits being carefully adjusted between each time interval in the total intervals to be optimized. It is applied to system of 31 units. It is observed that the method presented here achieves that generation fellows the load changes without any mismatch.

  • PDF

An Approach to Optimal Dispatch Scheduling Incorporating Transmission Security Constraints

  • Chung, Koo-Hyung;Kang, Dong-Joo;Kim, Balho H.;Kim, Tai-Hoon;Oh, Tae-Kyoo
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.199-206
    • /
    • 2008
  • The introduction of competition in electricity markets emphasizes the importance of sufficient transmission capacities to guarantee effective power transactions. Therefore, for the economic and stable electric power system operation, transmission security constrains should be incorporated into the dispatch scheduling problem. With the intent to solve this problem, we decompose a dispatch scheduling problem into a master problem(MP) and several subproblems(SPs) using Benders decomposition. The MP solves a general optimal power flow(OPF) problem while the SPs inspect the feasibility of OPF solution under respective transmission line contingencies. If a dispatch scheduling solution given by the MP violates transmission security constraints, then additional constraints corresponding to the violations are imposed to the MP. Through this iterative process between the MP and SPs, we derive an optimal dispatch schedule incorporating the post-contingency corrective rescheduling. In addition, we consider interruptible loads as active control variables since the interruptible loads can participate as generators in competitive electricity markets. Numerical examples demonstrate the efficiency of the proposed algorithm.

대기환경오염물질의 배출량을 고려한 경제부하배분 (Economic Load Dispatch Considering Atmospheric Emission in Power System)

  • 송길영;정민화;김용하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.574-577
    • /
    • 1995
  • The proposed method is described for scheduling their output of thermal power units so as to comply with total emission constraint, area emission constraint and the both of those constraints. Also, by using a trade-off curve, representing all dispatch alternatives and conflict between the emission and the fuel cost, the sensitivity analysis of the emission and the fuel cost is applied to this algorithm. By the way, this proposed method is analyzed how dispatch changes as a function of the total environmental cost, and as a function of the relative weighting of individual environmental insults, e.g, NOx and $SO_{2}$. By applying the proposed method to the system, the usefulness of this method is verified.

  • PDF

연계 계통에서의 환경적 배출량과 손실을 고려한 최적 경제급전 (Multi-Area Economic Dispatch Considering Environmental Emission and Transmission Losses)

  • 최승조;이상봉;김규호;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.341-343
    • /
    • 2000
  • Traditionally electric power system are operated in such a way that the total fuel cost is minimized regardless of accounting for tie-lines transmission constraint and emissions produced. But tie-lines transmission and emissions constraint are very important issues in the operation and planning of electric power system. This paper presents the Two-Phase Neural Network(TPNN) to solve the Economic Load Dispatch (ELD) problem with tie-lines transmission and emissions constraint considering transmission losses. The transmission losses are obtained from the B-coefficient which approximate the system losses as s quadratic function of the real power generation. By applying the proposed algorithm to the test system, the usefulness of this algorithm is verified.

  • PDF

비선형계획법에 의한 자동경제급전 알고리즘의 개발에 관한 연구 (Algorithm for Economic Load Dispatch by the Nonlinear Programming Method)

  • 박영문;김건중
    • 전기의세계
    • /
    • 제26권1호
    • /
    • pp.77-81
    • /
    • 1977
  • This paper aims to develope a new algorithm to overcome the disadvantages of the conventional E.L.D system based on the B-Constants and Penalty-Factors scheme. The main features of this paper are that the Variabiable Decoupled Method usually employed in the Load-Flow studies is introduced to the E.L.D. algorithm developed by Sasson, using the Powell's Nonlinear Programming Scheme. Besides this, other minor refinements are made to reduce memory spaces and computing time. Case studies show that the method suggested here has the remarkable advantages of computing efficiency and memory requirements over Sasson's.

  • PDF

CHP의 열거래 매커니즘 개발 (Development of CHP Heat Exchange Mechanism)

  • 김용하;이범;신형철;연준희;박정호;임현성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.125-126
    • /
    • 2007
  • This paper presents a CHP Heat Exchange Mechanism considering Economic Load Dispatch with Dynamic Programming. It calculates CHP heat generation cost and Heat load pattern. Also It presents CHP optimal operation through appliance of Heat Exchange Mechanism and investigates CHP optimal operation effects about connected two regions.

  • PDF

부하역률 제약을 고려한 최적 급전 알고리즘 (The optimal power flow algorithm considering load power factor limits)

  • 김광욱;조종만;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.98-100
    • /
    • 2003
  • This paper presents the method for computing the power economic dispatch with an optimal power flow (OPF) computation algorithm, considering the power factor limits constraint. Efficient reactive power planning enhances economic operation as well as system security. Accordingly, an adequate level of power factor limits for the load buses should be evaluated for economic operation. The power factor limits are included and described into the OPF's objective function. The proposed method is applied to IEEE 26 buses system.

  • PDF

정유공장 전력계통 동특성을 고려한 부하차단 적용 사례연구 (Load shedding case study of the refinery plant power system considering dynamic characteristic)

  • 이강완;임주일;김형태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.61-65
    • /
    • 2000
  • This paper presents the load shedding case studies and recommendations of load shedding scheme For improving the reliability to suit the requirements of LG-Caltex refinery plant power sγstem. It is recommended for LG-Caltex to decrease the total generation for the economic dispatch. When the LG-Caltex refinery is isolated from KEPCO utility system, the proper load shedding scheme should be implemented since total generation in LG-Caltex refinery plant is less than the load demand. According to the studies carried out the logic-based load shedding is recommended as the main protection scheme, with the combination of the under-frequency relay load shedding.

  • PDF

확률적 부하감소법을 이용한 민자발전소의 회피비용 계산 방법론 연구 (A Study on the Avioded Generation Costs of Indepndent Power Producers Using Probabilistic Load Decrement Method)

  • 박종배;원종률;박영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1340-1343
    • /
    • 1999
  • This Paper Presents a new analytic load decrement method for the evaluation of avoided generation costs of independent power producers (IPPs), named as probabilistic load decrement method. Unlike conventional load decrement methods, the proposed method exactly consider the random outage characteristic of a generating unit, economic dispatch order, and the resulting loss of load probability. Therefore, we can Provide the exact generation avoided costs of an IPP by applying the developed method. In the case studies, we have shown the correctness and effectiveness of the method, and compared with conventional load decrement methods.

  • PDF