• Title/Summary/Keyword: EcoDesign

Search Result 1,160, Processing Time 0.029 seconds

Durability Evaluation of the Korean Gauge - Adjustable Wheelset System (궤간가변 윤축시스템의 내구성 평가)

  • Ahn, Seung-Ho;Chung, Kwang-Woo;Jang, Seung-Ho;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5669-5675
    • /
    • 2012
  • To reduce the cost and the time of transport in Eurasian railroad networks such as TKR(Trans-Korea Railway), TCR(Trans-China Railway) and TSR(Trans-Siberia Railway) owing to the problem of different track gauges (narrow/standard/broad gauge), it is important to develop the gauge-adjustable wheelset(GAW) system to adapt easily to these gauges. The Korean GAW system is developing and will be adapting to the brand new freight trains' to improve the conventional overseas GAW system. In this study, structural and durability analyses are performed from the viewpoint of the safe-life design. The core parts of the system might be safe in range of $1{\times}10^7$ cycles from the result of durability analysis. Moreover, to examine the safety of the system while running on a track, rig fatigue test was performed according to UIC code. The safety of the Korean GAW system is demonstrated through testing that all safety-relevant conditions are satisfied.

Design of smart mobility status notification system (스마트 모빌리티 상태 알림 시스템 설계)

  • Park, Se-il;Jang, Jong-wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.11
    • /
    • pp.2128-2132
    • /
    • 2017
  • Smart mobility is rapidly emerging as a next-generation eco-friendly transportation system, and the market is booming every year. However, due to the characteristics of the devices that use electricity as the power source, the motor and the battery are different from the performance and actual performance indicated by the manufacturer depending on the user's weight and driving environment. Therefore, The frequency of the overload is increased and the failure and damage of the device are increasing. In this paper, we propose an application that provides personalized recommended driving guidance and overloaded driving situation notification at the actual driving separately from the recommended driving provided by the manufacturer after measuring the driving environment of the user, so as to prevent malfunction and damage of the smart mobility device, To ensure safety.

The Simplified Pre-Estimation Model Development of a BIPV Generation Rate by the District Division (지역 구분을 통한 약식 BIPV 발전량 예측 모델 개발)

  • Choi, Won-Ki;Oh, Min-Seok;Shin, Woo-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.19-29
    • /
    • 2016
  • Whilst there are growing interests in pursuing energy efficiency and zero-energy buildings in built environment, it is widely recognised that Building-Integrated Photovoltaic (BIPV) is one of the most promising and required technologies to achieve these goals in recent years. Although BIPV is a broadly utilized technique in variety of fields in built environments, it is required that generation of BIVP should be analysed and calculated by external specialists. The aim of this research is to focus on developing a new diagram for prediction of the pre-estimation model in early design stage to harness solar radiation data, PV types, slopes, azimuth and so forth. The results of this study show as follows: 1) We analysed 162 districts in a national level and the examined areas were categorised into five zones. The standard deviation of the results was 2.9 per cent; 2) The increased value of solar radiation on a vertical plane in five categorised zones was 42kWh/m3, and the result was similar to the average value of 43.8kWh/m3; and 3) The pre-estimation of diagram was developed based on the categorisation of zones and azimuth as well as the results of the developed diagram showed little difference compared to the previously utilised method. The suggested diagram in this paper will contribute to estimate BIPV without any external contribution to calculate the value. Even though the result of this study shows little difference, it is required to investigate a number of different variables such as BIPV types, modules, slope angle and so forth in order to develop an integrated pre-estimation diagram.

Design for Wastewater Neutralization Network in Yeosu Petrochemical Complex by Multi-Criteria Decision Making Strategy (다중척도 의사결정 전략을 이용한 여수 석유화학단지의 폐수 중화망 설계)

  • Lee, Tai-Yong
    • Clean Technology
    • /
    • v.17 no.2
    • /
    • pp.175-180
    • /
    • 2011
  • A novel multi-criteria decision making strategy is developed for the construction of industrial symbiosis network in eco-industrial park and the strategy is applied to the construction of acid/alkali wastewater neutralization network in Yeosu industrial complex. Acid (or alkali) wastewater is commonly generated in chemical industries, and it can be used as neutralizing agent for alkali (or acid) wastewater generated from another source. As a consequence, a large-scale industrial symbiosis network for wastewater neutralization can be constructed in petrochemical complexes where a large amount of acid/alkali wastewater is generated. In this study, substance flow model is constructed which describes the wastewater neutralization network and multi-criteria decision making strategy is applied to find a few candidate for industrial symbiosis network.

The Development of Maintenance Process in Long-Life Housing (장수명 공동주택 유지관리를 위한 프로세스 구축에 대한 연구)

  • Ji, Jang-Hun;Kim, Soo-Am;Yoon, Sang-Cho
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.115-124
    • /
    • 2010
  • The environment which has been destroyed for the national growth since 1960's would seem to offer infinite resources to human, but now, the existence of human being is threatened by the development thoughtless for the environment. The World Powers have concentrated on green growth with eco-friendly resource since the end of 20th century. Korea suggested that the vision was the low carbon for green growth in 2008. It is necessary to supply Long-Life Housing in the green technology in terms of the sustainable housing development based on various life style, life cycle of the residences, the restrain remodeling and redevelopment in construction. This study is aim to establish the development of maintenance process to make continuous inhabitation of Long-Life Housing that has the separated SI for maintenance, durability, variability and remodeling. The maintenance for Long-Life Housing is very important to have more than 50~70 years the long term of life cycle in comparison with Housing. Also, the roles of manager and user are important parts in Long-Life Housing. The present maintenance for Housing is shift and repair works by the routine maintenance and demage. However, The maintenance for Long-Life Housing should consider movement and flexibility. In addition, Long-Life Housing requires the proper process of maintenance because it is different from Housing in housing concept, design and constructions stage. Therefore this study shows the efficient maintenance process for Long-Life Housing.

Implementation of Successive Approximate Register typed A/D Converter for a Monitored Battery Voltage Conversion (모니터링된 배터리 전압 변환을 위한 SAR typed A/D 컨버터의 제작)

  • Kim, Seong-Kweon;Lee, Kyung-Ryang;Yeo, Sung-Dae;Hong, Justin S.Y.;Park, Yong-Eun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.256-261
    • /
    • 2011
  • In this paper, a design and an implementation of an Analog to Digital (A/D) converter are introduced for the conversion of monitored battery cell voltage in the cell voltage monitoring(CVM) system in battery management system(BMS), which is one of the key devices of ECO hybrid cars. The A/D converter in CVM system required a middle conversion speed and a high resolution, therefore, a successive approximate register(SAR) typed A/D converter with 10 bits resolution has been designed and implemented using Magna 0.6um 40V process. The measurement result which kept ${\pm}1$ LSB accuracy in the full scale range(FSR) of 5V, showed the usefulness of the SAR typed A/D converter in realizing a CVM system.

Analysis of Water Quality Components and Antibiotics in the Final Effluent of Wastewater Treatment Facilities in the Nakdong River Basin (낙동강 유역에 위치한 폐수처리시설 최종방류수의 수질과 항생물질 분석)

  • Park, Kyeong-deok;Kang, Dong-hwan;Jo, Won Gi;Yu, Hun Sun;Yoon, Yeon Su;Kim, Byung-Woo
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.857-870
    • /
    • 2020
  • In this study, the antibiotic components in the final effluent from the 12 wastewater treatment facilities located in the Nakdong River basin were investigated, and the correlation between organic matters, nutrients and antibiotics was analyzed. In the final effluent of the wastewater treatment facilities, three sulfonamides antibiotics (sulfamethazine, sulfathiazole, sulfachlorpyridazine) and tetracyclines antibiotics (oxytetracycline, doxycycline) were detected. Sulfamethazine were detected at all points and ranged from 10.398 to 278.784 ng/L. Sulfathiazole were detected at 6 points (Andong, Gumi, Hapcheon, Miryang, Uiryeong, Haman), and ranged from 23.773 to 144.468 ng/L. The correlation coefficients between sulfathiazole and TSS, COD, TOC, NH3-N, NO2-N, and T-N components were high in the range of 0.73 to 0.92. The correlation coefficient between sulfamethazine and T-N was 0.48, and the correlation with the rest of the water quality components was low. The correlation coefficient between sulfamethazine and sulfathiazole was 0.78. Through this study, it was confirmed that the concentration of sulfonamides antibiotics was higher than the concentration of tetracyclines antibiotics in the final effluent of 12 wastewater treatment facilities in the Nakdong River basin, and the concentration of sulfathiazole increased with organic matters and nutrients.

Analysis of significant factors for successful BIM technology application to Korean traditional house projects (한옥 건설 프로젝트에서의 BIM 도입 활성화를 위한 주요 요인 분석)

  • Jang, Ha-Ra;Lee, Joo-Sung;Seo, Hee-Chang;Oh, Jung-Keun;Kim, Jae-June
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.1
    • /
    • pp.71-81
    • /
    • 2013
  • Recently, Korean Traditional House is being reconsidered as a alternative and eco-friendly residential housing. With these flows, government and industry actively studies the modernization and industrialization of Korean Traditional House. Apply for BIM as a way of modernization and industrialization of Korean Traditional House, research has been actively conducted. Korean Traditional House is building that is assembled by individual Component Therefore it is very useful for modernization of the Korean Traditional House to design Korean Traditional House With BIM. Which is the management technology that produces and distributes information of the architecture. But compared with the effect, the use of BIM is sluggish in the construction. Therefore, In this study after surveying about lowly using BIM on point of AEC(Architect-Engineer-Contract), the result is analyzed with AHP(Analytic Hierarchy Process). So the aim of this study is to offer the base to find the solution of the Affecting factors about lowly using BIM.

Container Transportation Models in Industrial Estate Area (산업단지내 효율적 컨테이너 운송을 위한 수송 모형)

  • Shin, Jae Young;Kim, Woong-Sub
    • Journal of Navigation and Port Research
    • /
    • v.38 no.2
    • /
    • pp.171-176
    • /
    • 2014
  • Companies are facing challenges to have high competitiveness because of continuous oil price rising and CO2 emissions regulations. Thus, companies are trying hard to construct effective logistics and operation system to achieve high customer service quality and saving cost. Also the ec-friendly idustrial complex is needed. Busan is in process to construct GILC(Global Industry Logistics City) in west Busan province to achieve high competitiveness and support lack of industrial complex. To construct this kind of logistics industrial complex, it needs logistics system through proper policy and freight transportation co-operation. Especially, efficient management through logistics hierarchy construction in industrial complex is very important for low cost and eco-friendly point of view. Therefore, this paper aims to analyze logistics system and suggest operation model to present logistics complex construction base data.

Analysis of Energy Saving Rate of Office Buildings According to the Items of an EPI Machine Part (에너지 성능지표 기계부문 항목에 따른 업무용 건물의 에너지 절감율 분석)

  • Lee, Ho Jin;Kim, Seo Hoon;Jung, Jae Uk;Jang, Cheol Yong;Song, Kyoo Dong
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.49-54
    • /
    • 2013
  • released by IEA, 2010, indicated that Korea's GDP, of 8 countries surveyed-Korea, Frans, Germany, Italy, Japan, the UK, the USA, and Australia-was the lowest, but the electric consumption per head was third, following America and Australia. Thus, our government has been striving to reduce energy usage and especially to lessen the energy used in buildings, proposing a variety of road maps such as 'building energy efficiency rating' and 'energy saving design standards of buildings'. Accordingly, this study investigated the effect of the items of machine part among EPI items on the energy saving rate. I measured energy usage by ECO2 program, for simulation program, that is used for the building energy efficiency rating. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Therefore, I think that grades assigned to items in energy performance index need to be corrected.