Browse > Article
http://dx.doi.org/10.12813/kieae.2013.13.4.049

Analysis of Energy Saving Rate of Office Buildings According to the Items of an EPI Machine Part  

Lee, Ho Jin (Dept. of Architecture Hanyang Univ.)
Kim, Seo Hoon (Dept. of Architecture Hanyang Univ.)
Jung, Jae Uk (Dept. of Architecture Inha Univ.)
Jang, Cheol Yong (Korea Institute of Energy Research)
Song, Kyoo Dong (Dept. of Architecture Hanyang Univ.)
Publication Information
KIEAE Journal / v.13, no.4, 2013 , pp. 49-54 More about this Journal
Abstract
released by IEA, 2010, indicated that Korea's GDP, of 8 countries surveyed-Korea, Frans, Germany, Italy, Japan, the UK, the USA, and Australia-was the lowest, but the electric consumption per head was third, following America and Australia. Thus, our government has been striving to reduce energy usage and especially to lessen the energy used in buildings, proposing a variety of road maps such as 'building energy efficiency rating' and 'energy saving design standards of buildings'. Accordingly, this study investigated the effect of the items of machine part among EPI items on the energy saving rate. I measured energy usage by ECO2 program, for simulation program, that is used for the building energy efficiency rating. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Therefore, I think that grades assigned to items in energy performance index need to be corrected.
Keywords
Building Energy Efficiency Rating; Energy Performance Index; Building Energy Saving; Machine Part;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Kim Sang A. Evaluation of the Energy Efficiency Rating in small office building according to the Thermal Performance of Building Envelope. Korean journal of Solar Energy Society. 2012.8, 65-70   과학기술학회마을   DOI   ScienceOn
2 Song Ji Yong, A Study of applying VAV and VWV System to reduce Energy Consumption of Office building. Korean journal of Korea Institute of Ecological Architecture And Environment Society. Vol.13,No.1 2013.2   과학기술학회마을   DOI   ScienceOn
3 Lee Ho Jin. A study on the Improvement through Building Energy Efficiency Rating and Correlation Analysis of EPI in Office Buildings. Korean journal of Korea Institute of Ecological Architecture And Environment Society. 2012
4 Lee Ho Jin. A study on the Improvement through Building Energy Efficiency Rating and Correlation Analysis of EPI in Office Buildings. Proceeding Conferenceological Architecture And Environment Society. Vol.13,No.1 2013.2
5 Moon Mi Seon. A Study on Analysis of the Energy Performance Index Scores in the Green Building Certified Office Buildings. Korean journal of Architectural Institute of Korea, 2011;pp.365-372 1229-6163 KCI   과학기술학회마을
6 Provisions for energy efficient equipment dissemination.