• Title/Summary/Keyword: Echocardiography, Doppler

Search Result 89, Processing Time 0.03 seconds

Impact of Hemodialysis on Left Ventricular Performance: A Doppler Echocardiographic Study (혈액투석 유지요법 환자에서 투석 전후의 좌심실 Doppler 심초음파를 이용한 기능지표의 변화)

  • Kang, Dong-Oh;Lee, Du-Ha;Kim, Hyun-Seo;Kim, Hyun-Su;Kim, Sung-Rok;Park, Jong-Seon
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.309-317
    • /
    • 1999
  • Background: Left ventricular diastolic filling is an important determinant for maintenance of cardiac output during hemodialysis. Few investigators have studied the influence of hemodialysis on diastolic function. To evaluate the change of left ventricular systolic and diastolic function. we performed M-mode and Doppler echocardiographic studies before and after hemodialysis. Methods: The study population consisted of 30 patients(15 patients were male, mean age $45{\pm}10$ years) with CRF on maintenance hemodialysis. They have normal left ventricular systolic function(Fractional shortening>30%) and no evidence of valvular heart disease or regional wall motion abnormalities. The ejection fraction (EF) was measured using M-mode echocardiography and Doppler indices such as peak E velocity, peak A velocity, isovolumetric relaxation time(IVRT), deceleration time(DT). and left ventricular ejection time(LVET) obtained from Doppler echocardiography. The index of myocardial performance (IMP) was calculated from each of the Doppler velocity indices. Results: The weight reduction after hemodialysis was $2.1{\pm}1.0kg$(p<0.0001), After hemodialysis, there was some decrease in blood pressure(p<0.05), but no significant change in heart rate, EF and fractional shortening, mean VCF, peak A velocity, and DT. And significant reduction in peak E velocity, E/A ratio(p<0.0001. p<0.001), and significant increase in IVRT and IMP(p<0.05, p<0.0001) were noted. Conclusion: In conclusion, preload reduction is the main mechanism that accounts for changes in Doppler diastolic indices after hemodialysis. And an increased IMP suggests that diastolic function may be aggravated after hemodialysis, and that implies impaired left ventricular filling and disturbed left ventricular compliance.

  • PDF

Determination of Tricuspid Regurgitation Velocity/Pulmonary Artery Flow Velocity Time Integral in Dogs with Pulmonary Hypertension

  • Kim, Seungji;Oh, Dayoung;Lee, Siheon;Hong, Sungkyun;Choi, Mincheol;Yoon, Junghee
    • Journal of Veterinary Clinics
    • /
    • v.37 no.4
    • /
    • pp.185-190
    • /
    • 2020
  • This retrospective, echocardiographic study using 144 dogs with clear systolic tricuspid regurgitation on Doppler echocardiography was performed to determine the diagnostic value of the systolic tricuspid regurgitation velocity/pulmonary artery flow velocity time integral to predict the Doppler estimates of dogs with tricuspid regurgitation pressure gradient compared with other cardiac indices of pulmonary hypertension, and to investigate a cutoff value to select patients with a potentially poor outcome. The systolic tricuspid regurgitation velocity/pulmonary artery flow velocity time integral increased significantly as the severity of pulmonary hypertension increased and had a correlation coefficient that was analogous to those of other conventional cardiac indices. A cutoff value greater 1.65 provided the best-balanced sensitivity (84%) and specificity (80%) in determining patients with a poor prognosis. In conclusion, the systolic tricuspid regurgitation velocity/pulmonary artery flow velocity time integral is readily obtained using routine echocardiography and could provide a non-invasive, novel, and supplementary index for evaluating dogs with pulmonary hypertension as useful prognostic criteria, particularly in those with advanced pulmonary hypertension.

Prevalence of Patent Foramen Ovale and Diagnostic Efficacy of Transcranial Doppler Sonography in Cryptogenic Ischemic Stroke Patients

  • Kim, Dae-Sik;Kim, Byung-Weon;Cho, Sung-Jun
    • Biomedical Science Letters
    • /
    • v.15 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • The prevalence of patent foramen ovale (PFO) in healthy persons was estimated as about $10{\sim}25%$ and was up to 40% in patients with stroke. Transesophageal echocardiography (TEE) was considered to be the most sensitive method to detect PFO and was used as the gold standard. Transcranial doppler sonography (TCD) of the middle cerebral artery (MCA) during a contrast (saline bubble) injection has recently been proposed as an alternative detecting method for PFO. In this study, we would like to know the difference between TCD value and TEE value in subjects with cryptogenic ischemic stroke. We performed TCD and TEE tests to detect PFO on 64 patients (30 women and 34 men, mean age was 59.4 years) with cryptogenic ischemic stroke. PFO prevalence through TCD was 45.3% (29 of 64 patients) and the prevalence through TEE was 34.4% (22 of 64 patients). There was no statistical significance between PFO test and TCD test (P=0.206). But TCD had a sensitivity of 90.9% (20 of 22 patients), specificity of 78.6% (33 of 42 patients), positive predictive value of 69.0% (20 of 29 patients), and negative predictive value of 94.3% (33 of 35 patients). We concluded that TCD was a highly sensitive method for detecting a right-left shunt. Therefore, the non-invasive TCD test is a method more effective than the anti-invasive TEE test in the cost and evaluation of the existence or nonexistence of right to left shunt in addition to the screening method of the cerebrovascular disorder. Considering these points, TCD test could be recommended for patients with cryptogenic ischemic stroke as a useful and convenient method for screening of the existence or nonexistence of a right to left shunt caused by PFO.

  • PDF

Echocardiographic Assessment of Papillary Muscle Size and Function in Normal Beagle Dogs

  • Kim, Mijin;Choi, Sooyoung;Choi, Hojung;Lee, Youngwon;Lee, Kija
    • Journal of Veterinary Clinics
    • /
    • v.36 no.3
    • /
    • pp.155-158
    • /
    • 2019
  • Morphologic changes or functional impairments of the papillary muscle (PM) can influence mitral valve competence. The purpose of this study was to investigate PM size and contractile function using two-dimensional and color tissue Doppler echocardiography in normal dogs. 35 unsedated Beagle dogs without cardiovascular disease were examined. The vertical (VD) and horizontal diameter (HD) of the posterior and anterior PM was measured at end-diastole, and compared with the thickness of the left ventricular posterior wall (LVPWd). Longitudinal systolic movement of the PM was quantified as myocardial velocity and strain using tissue Doppler. The VD, HD, and ratios (VD/LVPWd, HD/LVPWd, VD/HD) were significantly greater in the posterior than anterior PM (P < 0.001). The VD and HD of posterior PM and the HD of anterior PM were significantly correlated with LVPWd (r = 0.47, 0.44, and 0.42, respectively). Body weight was significantly correlated with VD of posterior PM (r = 0.37). The peak systolic tissue velocity of the PM was $4.93{\pm}1.25cm/sec$ and peak strain was $-30.83{\pm}11.92%$. PM size and systolic function can be quantitatively assessed using two-dimensional and tissue Doppler. The establishment of these objective PM measurements may be useful to evaluate morphological and functional abnormalities of the canine PM.

Echocardiographic evaluation of heart failure in dogs with myxomatous mitral valve disease: a retrospective study

  • Han, Donghyun;Lee, Dong-Guk;Jung, Dong-In
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.79-85
    • /
    • 2018
  • Echocardiography is one of the most useful diagnostic techniques for differentiating heart disease as well as mitral valve lesion. Forty client-owned small breed dogs (weight, 2.3-13.2 kg) aged between 8-17 years with myxomatous mitral valve degeneration (MMVD) were included in the present study. The diagnosis of MMVD in dogs was made based on the clinical signs, chest radiography data, and echocardiographic findings. Echocardiographic examinations were conducted in accordance with recommended standards for dogs. M-mode, Doppler, and 2D echocardiography were performed in left and right lateral recumbency. 2D echocardiography was used to measure LA and Ao diameter from 2D short axis at the level of the aortic valve. In the comparison of conventional echocardiography indices in dogs with different stages of heart failure with MMVD, significant differences were observed in E/A ratio (p=0.005), EDV (p<0.001), EDVI (p<0.001), E-peak velocity (p= 0.001), ESV (p=0.028), ESVI (p=0.004), LA (p<0.001), LA/Ao Ratio (p<0.001), LVIDd (p<0.001), LVIDd/Ao Ratio (p<0.001), LVIDs (p=0.036), LVIDs/Ao Ratio (p=0.002), and MR Velocity (p=0.026). In addition, distinct correlations were found in EDV (r=0.712), LA/Ao ration (r=0.830), LVIDd (r=0.724), and LVIDd/Ao ratio (r=0.759). This study found that known conventional echocardiographic indices, including EDV, LA/Ao ratio, LVIDd dimension, and LVIDd/Ao ratio correlated with the severity of MMVD in point of significant differences and distinct correlations.

A case of pulmonic stenosis in a Shihtzu dog

  • Park, Chul;Yoo, Jong-Hyun;Jung, Dong-In;Kim, Ju-Won;Kang, Byeong-Teck;Park, Hee-Myung
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.1
    • /
    • pp.99-102
    • /
    • 2007
  • A 3-year-old, intact female, Shih-tzu dog was presented with a 15-day history of vomiting,depression, and anorexia. On physical examination, systolic ejection murmurs with precordial thril atthe left heart base were detected. A diagnosis of congenital pulmonic stenosis (PS) was made mainlyfrom the thoracic radiography, electrocardiography, and echocardiography. On complete blood counts andconfirmed that main pulmonary artery was tremendously buldged and electrocardiography was suggestiveof severe right ventricular hypertrophy. Echocardiographic findings revealed the pulmonic valve stenosiscontaining valvular dysplasia and poststenotic dilation. On Doppler echocardiography, ejection velocityof the lesion accounted for 3.38 m/sec, meaning mild velocity through the stenotic area. The dog'sproblem and resulted in death. However, there has been no reliable relation between PS and CRF. Primarymalformation of pulmonic valve was confirmed at necropsy after death.

Aortic Root Replacement with Pulmonary Autograft in Patient with Subaortic Abscess and False Aneurysm in Left Ventricular Outflow Tract -Report of A Case- (동맥근 농양 및 좌심실유출호 가성 심실류 환자에서 폐동맥 자가이식편을 이용한 대동맥근부치환술 -1례 치험 보고-)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.28 no.7
    • /
    • pp.704-707
    • /
    • 1995
  • The use of the patient`s pulmonary valve for replacement of the patient`s diseased aortic valve was introduced and developed by Mr. Donald Ross. The long term benefits of having a normal, fully viable, trileaflet semilunar valve in aortic position was demonstrated. A 38 year old male had histories of failures of previously implanted aortic prosthetic valves twice and evidence of progressive heart failure. At operation, aortic root abscess was found; the abscess extension to adjacent structures and partial valve dehiscence had occurred. The patient underwent replacement of the aortic root with autologous pulmonary valve, autologous pericardial patch repair of left ventricuar outflow tract and recontruction of the right ventricular outflow tract and pulmonary artery with prosthetic valved conduit. Postoperatively, the patient recovered well. Postoperative doppler echocardiography demonstrated minimal central regurgitation in new aortic valve. Aortic root replacement with pulmonary autograft in a patient of recurrent aortic root abscess and false aneurysm of left ventricuar outflow tract was experienced and reported with follow up echocardiography.

  • PDF

Modified Tei index in patients with Kawasaki disease by tissue doppler imaging (가와사키병 환아에서 Tissue doppler imaging으로 측정한 modified Tei 지수)

  • Kim, Hee Jung;Cha, Jung Hwa;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1202-1210
    • /
    • 2006
  • Purpose : A quantitative and easily measured Doppler index of combined systolic and diastolic ventricular myocardial performance (Tei index) was recently proposed as a potentially useful predictor of global myocardial performance. However, presence of heart rate fluctuation makes it unreliable. Therefore, the modified Tei index was introduced by using tissue Doppler imaging (TDI) which enables measuring contraction and relaxation velocities from myocardium simultaneously. The purpose of this study was to investigate the effectiveness of the modified Tei index in the evaluation of global cardiac function. Methods : Forty eight patients in the acute phase of Kawasaki disease (KD) were studied. These patients were divided into two groups according to the modified Tei index. TDI and conventional echocardiography were performed. Systolic velocity, systolic displacement, E' velocity, E' displacement, A' velocity and A' displacement were measured at the base, mid-septum and the apex of the interventricular septum. Ejection fraction (EF), Tei index and modified Tei index were estimated. Results : Modified Tei index correlated negatively with systolic displacement, E' displacement and A' displacement at the base. Modified Tei index correlated positively with ESR and CRP. EF and Tei index were normal in KD patients. Conclusion : Modified Tei index is a safe, feasible and sensitive index for evaluating global ventricular functions in spite of normal EF and Tei index in KD.

The Study on the Appropriate Workforce Estimation of Clinical Technologists for Job Creation in the Field of Ultrasonic Inspection

  • Bae, Hyung-Joon;Kim, Dae-Sik;Lee, Og kyoung;Kim, Chul-Seung;Choi, Sun Young;An, Young-Hoi;Kim, Eun-Young;Kang, Kun-Woo;Jang, Jin-Yong
    • Biomedical Science Letters
    • /
    • v.25 no.4
    • /
    • pp.381-389
    • /
    • 2019
  • The physiological function test is the only patient contact area in the field of clinical laboratory. We need to recruit and encourage the experts due to requiring the expertise and long time for examination. However, there is currently no rule for estimating optimal workforce in the field of physiological function tests. The purpose of this study is to establish the basis of the studies for mid- to long-long term job creation in the field of ultrasound by evaluating the number of appropriate tests and appropriate workforce. We calculated the quantitative and qualitative workload for the number of appropriate tests and appropriate workforce using online questionnaire. All statistical analyses were performed using SPSS version 18.0 (SPSS Inc., Chicago, IL, USA). A total of 216 respondents were 48 (22.2%) male and 168 (77.8%) female. A total of 157 laboratories were 62 (39.5%) for echocardiography, 91 (58.0%) for the transcranial Doppler (TCD) and 4 (5.7%) for the carotid ultrasound. The mean number of appropriate tests was 10 ± 2 in the echocardiography, 9 ± 2 in TCD and 11 ± 2 in the carotid ultrasound. In addition, the number of laboratories required to recruit employees for appropriate workforce was 19 in echocardiography, 18 in TCD, and 0 in carotid ultrasound. The number of hospital required to recruit workforce were 7 primary hospitals, 22 secondary hospitals, 7 third hospitals. This study can be used as an important data as the first study at present time when the data on the workforce status and work environment of the ultrasonic laboratories is insufficient. Based on the quantitative and qualitative workloads, the number of appropriate tests and appropriate workforce can support mid- to long-long term job creation in the field of ultrasound.