• 제목/요약/키워드: Earthquake intensity

검색결과 303건 처리시간 0.031초

LCC Optimization for Reinforced Concrete Structures under Seismic Hazards

  • Park, Soon-Kyu
    • KCI Concrete Journal
    • /
    • 제13권2호
    • /
    • pp.26-32
    • /
    • 2001
  • A simple expected damage cost model is developed and a systematic approach to evaluate the economic effects of seismic hazards to reinforced concrete structures is presented. An expected damage cost function during a specific lifetime is modeled by a Poisson's process with uniform continuous cash flow assumption. It is possible that the proposed method can decouple the damage cost effect from random earthquake events. Thus, expected damage cost function can be formulated as a combination of three independent terms; a present worth factor of Poisson's process, a damage cost interpolation function and a mean occurrence rate of earthquake intensity. The validity of the proposed method is demonstrated by a comparative study of LCC evaluations with the previous study.

  • PDF

K-function Test for he Spatial Randomness among the Earthquakes in the Korean Peninsula

  • Baek, Jangsung;Bae, Jong-Sung
    • Communications for Statistical Applications and Methods
    • /
    • 제8권2호
    • /
    • pp.499-505
    • /
    • 2001
  • Kim and Baek (2000) tested the spatial randomness for he earthquake occurrence in the Korean Peninsula by using the nearest-neighbor test statistics and empirical distribution functions. The K-function, however, has obvious advantages over the methods used in Kim and Baek (2000), such as it does not depend on the shape of the study region and is an effective summary of spatial dependence over a wide range of scales. We applied the K-function method for testing the randomness to both of the historical and the instrumental seismicity data. It was found that he earthquake occurrences for historical and instrumental seismicity data are not random and clustered rather than scattered.

  • PDF

Influence of near-fault ground motions characteristics on elastic seismic response of asymmetric buildings

  • Tabatabaei, R.;Saffari, H.
    • Structural Engineering and Mechanics
    • /
    • 제40권4호
    • /
    • pp.489-500
    • /
    • 2011
  • The elastic seismic response of plan-asymmetric multi storey steel-frame buildings is investigated under earthquake loading with particular emphasis on forward-rupture directivity and fling records. Three asymmetric building systems are generated with different torsional stiffness and varying static eccentricity. The structural characteristic of these systems are designed according to UBC 97 code and their seismic responses subjected to a set of earthquake records are obtained from the response history analysis (RHA) as well as the linear static analysis (LSA). It is shown that, the elastic torsional response is influenced by the intensity of near-fault ground motions with different energy contents. In the extreme case of very strong earthquakes, the behaviour of torsionally stiff buildings and torsionally flexible buildings may differ substantially due to the fact that the displacement envelope of the deck depends on ground motion characteristics.

The influence of vertical ground motion on the seismic behavior of RC frame with construction joints

  • Yu, Jing;Liu, Xiaojun
    • Earthquakes and Structures
    • /
    • 제11권3호
    • /
    • pp.407-420
    • /
    • 2016
  • The aim of this study is to investigate the effect of vertical ground motion (VGM) on seismic behavior of reinforced concrete (RC) regular frame with construction joints, and determine more proper modeling method for cast-in-situ RC frame. The four-story RC frames in the regions of 7, 8 and 9 earthquake intensity were analyzed with nonlinear dynamic time-history method. Two different methods of ground motion input, horizontal ground motion (HGM) input only, VGM and HGM input simultaneously were performed. Seismic responses in terms of the maximum vertex displacement, the maximum inter-story drift distribution and the plastic hinge distribution were analyzed. The results show that VGM might increase or decrease the horizontal maximum vertex displacement depending on the value of axial load ratio of column. And it will increase the maximum inter-story drift and change its distribution. Finally, proper modeling method is proposed according to the distribution of plastic hinges, which is in well agreement with the actual earthquake damage.

Seismic risk assessment of staggered wall system structures

  • Kim, Jinkoo;Baek, Donggeol
    • Earthquakes and Structures
    • /
    • 제5권5호
    • /
    • pp.607-624
    • /
    • 2013
  • In this study the seismic risk assessments of six- and twelve-story staggered wall system structures with three different structural variations were performed. The performances of staggered wall structures with added columns along the central corridor and the structures with their first story walls replaced by beams and columns were compared with those of the regular staggered wall structures. To this end incremental dynamic analyses were carried out using twenty two pairs of earthquake records to obtain the failure probabilities for various intensity of seismic load. The seismic risk for each damage state was computed based on the fragility analysis results and the probability of occurrence of earthquake ground motions. According to the analysis results, it was observed that the structures with added columns along the central corridor showed lowest probability of failure and seismic risk. The structures with their first story walls replaced by beams and columns showed lowest margin for safety.

중진지역에서의 다경간연속교의 내진설계 방향 (Seismic Design Strategies of Multi-Span Continuous Bridges in Moderate Seismicity Region)

  • 김재관;김익현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.292-299
    • /
    • 2002
  • It has been realized that the design codes and underlying design concept of high seismicity region may not be appropriate to low and moderate seismicity regions. The aim of this paper is to search seismic design strategies that are appropriate to moderate seismicity regions. The characteristics of seismic hazard in moderate seismicity regions are reviewed. The seismic responses of multi-span continuous bridges subjected to the ground shaking of moderate intensity are examined. The present code on seismic design of bridges is briefly reviewed. Based on these observations, design principles and strategies appropriate to the moderate seismicity regions are proposed for the multi-span continuous bridge

  • PDF

기초격리된 구조물에서 자기유동성 유체감쇠기의 면진성능에 관한 연구 (A Study on the Seismic Performance of MR Fluid Dampers in Base-Isolated Structures)

  • 이종세;도학용
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.371-378
    • /
    • 2002
  • The design concepts using vibration reduction techniques, or structural control, have been proposed recently to protect infrastructure against earthquakes. The magnetorheological(MR) fluid damper is one of the most promising new devices for structural vibration reduction because of its mechanical simplicity, high dynamic range, low power requirement, large force capacity and robustness. In this study, the seismic performance of MR devices are compared with that of NZ systems as an attempt to provide some data for improving seismic design techniques applied to structures. For nonlinear time domain analysis of a base isolation system, a six-story building model is considered as a numerical example. The ground acceleration data of El Centre 1940, Mexico City 1985 and Kobe 1995 earthquakes are used as seismic excitations. The results show that MR damper systems for outperform NZ systems in wide-ranging seismic excitations with respect to intensity and period characteristics.

  • PDF

지진가속도 간의 칼라코드 표준화 (Suggestion of standard color code for displaying ground acceleration)

  • 지헌철;전정수;신진수;이희일;박정호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.61-71
    • /
    • 2002
  • Color-code imaging should be one of the best display tools for the quick perception of both damage area and its intensity, In this study we proposed the standard color code corresponding to maximum observed acceleration value. Since the acceleration value changes with frequency contents, we suggested to limit the frequency band less than 10Hz. The background considerations of this limitation, magnitude vs. dominant frequency, natural characteristics of artificial noises and the relationship between velocity and acceleration, were reviewed in detail. The standard of color code was assigned from 0.001%g to 20%g based on the possible earthquakes at Korean peninsula and the color imaging given by RGB value was shown to be very consistent, irrespective of hardware configuration.

  • PDF

고차모드 영향이 반영된 Pushover 해석을 위한 횡하중 분배계수 제안 (Lateral Load Distribution Factor for Modal Pushover Analysis)

  • 김건우;송진규
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.236-243
    • /
    • 2005
  • Nonlinear static analysis is used to quantify the resistance of the structure to lateral deformation and to gauge the mode of deformation and intensity of local demands. A simple method for the nonlinear static analysis of complex building structures subjected to monotonically increasing horizontal loading(pushover analysis) is presented. The method is designed to be a part of new methodologies for the seismic design and evaluation of structures. A variety of existing pushover analysis procedures are currently being consolidated under programs such as ATC 40 and FEMA 273. And various techniques have been recommended, including the use of constant lateral force profiles and the use of adaptive and multimodal approaches. In this paper a modal pushover analysis using design response spectra of UBC 97 is proposed. Proposed method is compared against the method in FEMA 273 and ATC 40, and results of time history analysis.

  • PDF

국내 저층 콘크리트 골조의 초과강도 (Seismic Overstrength of Low-rised RC Frame in Korea)

  • 이영욱
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.28-35
    • /
    • 1998
  • The seismic overstrength factor $\Omega$ is evaluated for 4-story reinforced concrete buildings in Korea(of which seismic intensity is low). The study model is designed according to aseismic guideline research - phase II in Korea. The effect of variation of span length and bay number, dead load is considered, especially including the variation of hardening ration after yielding. And push-over analysis is performed, in which the external and internal frame is connected by rigid-link and the $\Omega$ is calculated using the roof drift ratio at 2%. For Zone I, the mean value of $\Omega$ is ranged form 2.3 to 2.5, For Zone II, from 3.1 to 3.4. For low hardening ratio(3%) after yielding, $\Omega$ has little relations with the number of bay, like as the results of other research. But for 5% hardening ratio, $\Omega$ is increased as the number of bay is increased. Within general gravity-load bound, the variation of D.L. has variation of D. L. has no effect on $\Omega$. And, $\Omega$ is increased as the span length is increased.

  • PDF