• Title/Summary/Keyword: Earthquake control system

Search Result 341, Processing Time 0.021 seconds

Structural control of cable-stayed bridges under traveling earthquake wave excitation

  • Raheem, Shehata E Abdel
    • Coupled systems mechanics
    • /
    • v.7 no.3
    • /
    • pp.269-280
    • /
    • 2018
  • Post-earthquake damages investigation in past and recent earthquakes has illustrated that the ground motion spatial variation plays an important role in the structural response of long span bridges. For the structural control of seismic-induced vibrations of cable-stayed bridges, it is extremely important to include the effects of the ground motion spatial variation in the analysis for design of an effective control system. The feasibility and efficiency of different vibration control strategies for the cable-stayed bridge under multiple support excitations have been examined to enhance a structure's ability to withstand earthquake excitations. Comparison of the response due to non-uniform input ground motion with that due to uniform input demonstrates the importance of accounting for spatial variability of excitations. The performance of the optimized designed control systems for uniform input excitations gets worse dramatically over almost all of the evaluation criteria under multiple-support excitations.

Multiple Pounding Tuned Mass Damper (MPTMD) control on benchmark tower subjected to earthquake excitations

  • Lin, Wei;Lin, Yinglu;Song, Gangbing;Li, Jun
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1123-1141
    • /
    • 2016
  • To explore the application of traditional tuned mass dampers (TMDs) to the earthquake induced vibration control problem, a pounding tuned mass damper (PTMD) is proposed by adding a viscoelastic limitation to the traditional TMD. In the proposed PTMD, the vibration energy can be further dissipated through the impact between the attached mass and the viscoelastic layer. More energy dissipation modes can guarantee better control effectiveness under a suite of excitations. To further reduce mass ratio and enhance the implementation of the PTMD control, multiple PTMDs (MPTMD) control is then presented. After the experimental validation of the proposed improved Hertz based pounding model, the basic equations of the MPTMD controlled system are obtained. Numerical simulation is conducted on the benchmark model of the Canton Tower. The control effectiveness of the PTMD and the MPTMD is analyzed and compared under different earthquake inputs. The sensitivity and the optimization of the design parameters are also investigated. It is demonstrated that PTMDs have better control efficiency over the traditional TMDs, especially under more severe excitation. The control performance can be further improved with MPTMD control. The robustness can be enhanced while the attached mass for each PTMD can be greatly reduced. It is also demonstrated through the simulation that a non-uniformly distributed MPTMD has better control performance than the uniformly distributed one. Parameter study is carried out for both the PTMD and the MPTMD systems. Finally, the optimization of the design parameters, including mass ratio, initial gap value, and number of PTMD in the MPTMD system, is performed for control improvement.

Experimental Study on the Active Control of a Three-story Building using $\textrm{H}_2$method ($\textrm{H}_2$제어 기법을 적용한 3층 건물의 능동제어 실험)

  • Joo, Soek-Jun;Min, Kyung-Won;Lee, Sung-Kyung;Kim, Sung-Chon;Hong, Sung-Mok
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.225-232
    • /
    • 1999
  • For the study of the seismic-response control, it is necessary to use an experimental system with an earthquake simulator and control devices employing a hydraulic actuator system. However, such system is too expensive to prepare at the university laboratory. In this research, an economical experimental system is developed which has a small-sized earthquake simulator and an AMD using AC servo motors. An accurate mathematical model of the three-degree-of-freedom tests structure with an AMD is developed from the measurement of the input/output relationships of the structure. This paper demonstrates experimentally the efficacy of the frequency domain optimal control algorithm H$_2$in reducing the response of seismically excited building to verify the performance of the experimental system.

  • PDF

The study of Safety education, safe experience for students to develop research simulreyiteo (안전체험 시뮬레이터 개발에 관한 연구)

  • Kim, Tae-hwan
    • Journal of the Society of Disaster Information
    • /
    • v.6 no.1
    • /
    • pp.46-59
    • /
    • 2010
  • In this study, the safety training of comparative analysis of the realities of Korea's safety training and international experience and practical training for the safety experience of a virtual reality simulator, the development of safe conduct as a controlled motion simulator system, image H / W and the control system works, sound effects H / W and the control system works, 4D special effects (smoke, heat, wind, vibration) and a control system integration, mission control system for the selection and evaluation of the proposal, and safety training on Game S / W of development as we have never experienced an earthquake action plan and evacuate to escape the power of experience and the experience of an earthquake (vibration + video), Also the collapse and a fire escape on the experience of following second disaster, the building collapsed during an escape experience in the field, in case of fire According to the initial fire suppression and fire extinguisher usage experience - experience of smoke and heat to escape in, Moreover, the Daegu subway fire in public places such as subway and evacuated to escape the experience, considering the suggested Simulator.

System Identification of the Three Story Building Structure with a Controller (제어기가 설치된 3층 건물의 시스템 식별)

  • 주석준
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.203-211
    • /
    • 1999
  • Threr are several methods in protecting the building structures from dynamic loads such as an earthquake and a wind. Among them applying a control force to the building structure is one of the methods to decrease the vibration. The most important and difficult problem in the active control is to obtain the mathematical model of the building structure with a controller. the effective active controller can be designed from the exact model of the system In this paper the three story test building with an active mass driver is identified experimentally. the system matrices corresponding to the experimental building are found and verified with the experimentally-obtained transfer functions and responses efficiently.

  • PDF

Performance Evaluation of Multi-Hazard Adaptive Smart Control Technique Based on Connective Control System (연결 제어 시스템 기반의 멀티해저드 적응형 스마트 제어 기술 성능 평가)

  • Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.97-104
    • /
    • 2018
  • A connected control method for the adjacent buildings has been studied to reduce dynamic responses. In these studies, seismic loads were generally used as an excitation. Recently, multi-hazards loads including earthquake and strong wind loads are employed to investigate control performance of various control systems. Accordingly, strong wind load as well as earthquake load was adopted to evaluate control performance of adaptive smart coupling control system against multi-hazard. To this end, an artificial seismic load in the region of strong seismicity and an artificial wind load in the region of strong winds were generated for control performance evaluation of the coupling control system. Artificial seismic and wind excitations were made by SIMQKE and Kaimal spectrum based on ASCE 7-10. As example buildings, two 20-story and 12-story adjacent buildings were used. An MR (magnetorheological) damper was used as an adaptive smart control device to connect adjacent two buildings. In oder to present nonlinear dynamic behavior of MR damper, Bouc-Wen model was employed in this study. After parametric studies on MR damper capacity, optimal command voltages for MR damper on each seismic and wind loads were investigated. Based on numerical analyses, it was shown that the adaptive smart coupling control system proposed in this study can provide very good control performance for Multi-hazards.

Vibration suppression analysis of a long-span cable-stayed bridge based on earthquake-wind-traffic-bridge coupled system

  • Xinfeng Yin;Yong Liu;Wanli Yan;Yang Liu;Zhou Huang
    • Structural Engineering and Mechanics
    • /
    • v.88 no.4
    • /
    • pp.379-387
    • /
    • 2023
  • Wind and earthquake loads may cause strong vibrations in large-span cable-stayed bridges, leading to the inability of the bridge to operate normally. An improved Pounding Tuned Mass Damper (PTMD) system was designed to improve the safety of the large-span cable-stayed bridge. The vibration control effect of the improved PTMD system on the large-span cablestayed bridge under the combined action of earthquake-wind-traffic was studied. Furthermore, the impact of different parameters on the vibration suppression performance of the improved PTMD system was analyzed. The numerical results indicate that the PTMD system is very effective in suppressing the displacements of the bridge caused by both the traffic-wind coupling and traffic-earthquake coupling. Moreover, the number, mass ratio, pounding stiffness, and gap values have a significant influence on the vibration suppression performance of the improved PTMD system. When the number of PTMD is increased from 3 to 9, the vibration reduction ratio of the vertical displacement is increased from 25.39% to 48.05%. As the mass ratio changes from 0.5% to 2%, the vibration reduction ratio increases significantly from 22.23% to 53.30%.

Experiment of an ABS-type control strategy for semi-active friction isolation systems

  • Lu, Lyan-Ywan;Lin, Ging-Long;Lin, Chen-Yu
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.501-524
    • /
    • 2011
  • Recent studies have discovered that a conventional passive isolation system may suffer from an excessive isolator displacement when subjected to a near-fault earthquake that usually has a long-period velocity pulse waveform. Semi-active isolation using variable friction dampers (VFD), which requires a suitable control law, may provide a solution to this problem. To control the VFD in a semi-active isolation system more efficiently, this paper investigates experimentally the possible use of a control law whose control logic is similar to that of the anti-lock braking systems (ABS) widely used in the automobile industry. This ABS-type controller has the advantages of being simple and easily implemented, because it only requires the measurement of the isolation-layer velocity and does not require system modeling for gain design. Most importantly, it does not interfere with the isolation period, which usually decides the isolation efficiency. In order to verify its feasibility and effectiveness, the ABS-type controller was implemented on a variable-friction isolation system whose slip force is regulated by an embedded piezoelectric actuator, and a seismic simulation test was conducted for this isolation system. The experimental results demonstrate that, as compared to a passive isolation system with various levels of added damping, the semi-active isolation system using the ABS-type controller has the better overall performance when both the far-field and the near-fault earthquakes with different PGA levels are considered.

Cyclic testing of innovative two-level control system: Knee brace & vertical link in series in chevron braced steel frames

  • Rousta, Ali Mohammad;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • v.64 no.3
    • /
    • pp.301-310
    • /
    • 2017
  • For further development of passive control systems to dissipate larger seismic energy and prevent the structures from earthquake losses, this paper proposes an innovative two-level control system to improve behavior of chevron braced steel frames. Combining two Knee Braces, KB, and a Vertical Link Beam, VLB, in a chevron braced frame, this system can reliably sustain main shock and aftershocks in steel structures. The performance of this two-level system is examined through a finite element analysis and quasi-static cyclic loading test. The cyclic performances of VLB and KBs alone in chevron braced frames are compared with that of the presented two-level control system. The results show appropriate performance of the proposed system in terms of ductility and energy dissipation in two different excitation levels. The maximum load capacity of the presented system is about 30% and 17% higher than those of the chevron braced frames with KB and VLB alone, respectively. In addition, the maximum energy dissipation of the proposed system is about 78% and 150% higher than those of chevron braced frames with VLB and KB respectively under two separate levels of lateral forces caused by different probable seismic excitations. Finally, high performance under different earthquake levels with competitive cost and quick installation work for the control system can be found as main advantages of the presented system.

Semiactive Neuro-control for Seismically Excited Structure considering Dynamics of MR Damper (자기유변유체감쇠기의 동특성을 고려한 지진하중을 받는 구조물의 반능동 신경망제어)

  • 이헌재;정형조;오주원;이인원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.473-480
    • /
    • 2003
  • A new semiactive control strategy for seismic response reduction using a neuro-controller and a magnetorheological (MR) fluid damper is proposed. The proposed control system adopts a clipped algorithm which induces the MR damper to generate approximately the desired force. The improved neuro-controller, which was developed by employing the training algorithm based on a cost function and the sensitivity evaluation algorithm replacing an emulator neural network, produces the desired active control force, and then by using the clipped algorithm the appropriate command voltage is selected in order to cause the MR damper to generate the desired control force. The simulation results show that the proposed semiactive neuro-control algorithm is quite effective to reduce seismic responses. In addition, the semiactive control system using MR fluid dampers has many attractive features, such as bounded-input, bounded-output stability and small energy requirements. The results of this investigation, therefore, indicate that the proposed semiactive neuro-control strategy using MR fluid dampers could be effective used for control seismically excited structures.

  • PDF