Browse > Article
http://dx.doi.org/10.12989/sss.2011.8.5.501

Experiment of an ABS-type control strategy for semi-active friction isolation systems  

Lu, Lyan-Ywan (Department of Construction Engineering, National Kaohsiung First University of Science and Technology)
Lin, Ging-Long (Department of Civil Engineering, National Chung Hsing University)
Lin, Chen-Yu (National Center for Research on Earthquake Engineering)
Publication Information
Smart Structures and Systems / v.8, no.5, 2011 , pp. 501-524 More about this Journal
Abstract
Recent studies have discovered that a conventional passive isolation system may suffer from an excessive isolator displacement when subjected to a near-fault earthquake that usually has a long-period velocity pulse waveform. Semi-active isolation using variable friction dampers (VFD), which requires a suitable control law, may provide a solution to this problem. To control the VFD in a semi-active isolation system more efficiently, this paper investigates experimentally the possible use of a control law whose control logic is similar to that of the anti-lock braking systems (ABS) widely used in the automobile industry. This ABS-type controller has the advantages of being simple and easily implemented, because it only requires the measurement of the isolation-layer velocity and does not require system modeling for gain design. Most importantly, it does not interfere with the isolation period, which usually decides the isolation efficiency. In order to verify its feasibility and effectiveness, the ABS-type controller was implemented on a variable-friction isolation system whose slip force is regulated by an embedded piezoelectric actuator, and a seismic simulation test was conducted for this isolation system. The experimental results demonstrate that, as compared to a passive isolation system with various levels of added damping, the semi-active isolation system using the ABS-type controller has the better overall performance when both the far-field and the near-fault earthquakes with different PGA levels are considered.
Keywords
anti-lock braking system; ABS system; shaking table test; seismic isolation; semi-active control; variable friction damper; piezoelectric actuator; near-fault earthquake;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 Agrawal, A.K., Xu, Z. and He, W.L. (2006), "Ground motion pulse-based active control of a linear base-isolated benchmark building", Struct. Cont. Health Monit., 13(2-3), 792-808.   DOI   ScienceOn
2 Baker, J.W. (2007), "Quantitative classification of near-fault ground motions using wavelet analysis", Bull. Seismol. Soc. Am., 97(5), 1486-1501.   DOI   ScienceOn
3 Batterbee, D.C. and Sims, N.D. (2005), "Vibration isolation with smart fluid dampers: a benchmarking study", Smart Struct. Syst., 1(3), 235-256.   DOI
4 Chen, C. and Chen, G. (2004), "Shaking table test of quarter-scale building model with piezoelectric friction dampers", Struct. Cont. Health Monit., 11, 239-257.   DOI   ScienceOn
5 Chen, G. and Lu, L.Y. (2008), "Functionally upgraded passive devices for seismic response reduction", Smart Struct. Syst., 4(6), 741-757.   DOI
6 Derek, N. and Allen, B. (2005), A Practical Approach to Motor Vehicle Engineering and Maintenance, Elsevier Butterworth Heinemann.
7 Douglas J.W. and Schafer T.C. (1971), The Chrysler sure brake: The first production four-wheel anti-skid system, SAE Tech. Paper 710248.
8 Dupont P., Kasturi, P. and Stokes, A. (1997), "Semi-active control of friction dampers", J. Sound Vib., 202(2), 203-218.   DOI   ScienceOn
9 Kori, J.G. and Jangid, R.S. (2008), "Semi-active friction dampers for seismic control of structures", Smart Struct. Syst., 4(4), 493-515.   DOI
10 Laflamme, S., Taylor, D., Maane, M.A. and Connor, J.J. (2011) "Modified friction device for control of large scale systems", Struct. Cont. Health Monit., published online: 15 MAR 2011, DOI: 10.1002/stc.454.
11 Limper, R. (1999), Brake Design and Safety Second Edition Society of Automotive Engineers, Inc, 372-374.
12 Lin, C.C., Lin, G.L. and Wang, J.F. (2010), "Protection of seismic structures using semi-active friction TMD", Earthq. Eng. Struct. D., 39(6), 635-659.
13 Lu, L.Y. (2004), "Semi-active modal control for seismic structures with variable friction dampers", Eng. Struct., 26(4), 437-454.   DOI   ScienceOn
14 Lu, L.Y., Chung, L.L., Wu, L.Y. and Lin, G.L. (2006), "Dynamic analysis of structures with friction devices using discrete-time state-space formulation", Comput. Struct., 84(15-16), 1049-1071.   DOI   ScienceOn
15 Lu, L.Y., Lin, C.C., Lin, G.L. and Lin, C.Y. (2010b), "Experiment and analysis of a fuzzy-controlled piezoelectric seismic isolation system", J. Sound Vib., 329(11), 1992-2014.   DOI   ScienceOn
16 Lu, L.Y. and Lin, G.L. (2008), "Predictive control of smart isolation system for precision equipment subjected to near-fault earthquakes", Eng. Struct., 30(11), 3045-3064.   DOI   ScienceOn
17 Lu, L.Y., Chung, L.L. and Lin, G.L. (2004), "A general method for semi-active feedback control of variable friction dampers", J. Intell. Mater. Sys. Struct., 15(5), 393-412.   DOI   ScienceOn
18 Lu, L.Y., Lin, T.K. and Yeh, S.W. (2010a), "Experiment and analysis of a leverage-type stiffness controllable isolation system for seismic engineering", Earthq. Eng. Struct. D., 39(15), 1711-1736.   DOI   ScienceOn
19 Makris, N. and Chang, S.P. (2000), "Effect of viscous, viscoelastic and friction damping on the response of seismic isolated structures", Earthq. Eng. Struct. D., 29(1), 85-107.   DOI   ScienceOn
20 Naeim, F. and Kelly, J.M. (1999), Design of Seismic Isolated Structures Chapter 4, John Wiley & Sons, Inc., New York.
21 Nagarajaiah, S. and Narasimhan, S. (2006), "Smart base isolated benchmark building Part II: Phase I Sample controllers for linear isolation system", Struct. Cont. Health Monit., 13(2-3), 589-604.   DOI   ScienceOn
22 Narasimhan, S. and Nagarajaiah, S. (2006), "Smart base isolated buildings with variable friction systems: H ${\infty}$ controller and SAIVF device", Earthq. Eng. Struct. D., 35(8), 921-942.   DOI   ScienceOn
23 Ng, C.L. and Xu, Y.L. (2007), "Semi-active control of a building complex with variable friction dampers", Eng. Struct., 29(6), 1209-1225.   DOI   ScienceOn
24 Petti, L., Giannattasio, G., Iuliis, M.D. and Palazzo, B. (2010), "Small scale experimental testing to verify the effectiveness of the base isolation and tuned mass dampers combined control strategy", Smart Struct. Syst., 6(1), 57-72.   DOI
25 Saharabudhe, S. and Nagarajaiah, S. (2005), "Effectiveness of variable stiffness systems in base isolated bridges subjected to near fault earthquakes: Experimental study", J. Intell. Mater. Sys. Struct., 16(9), 743-756.   DOI   ScienceOn
26 Reigles, D.G. and Symans, M.D. (2006), "Supervisory fuzzy control of a base-isolated benchmark building utilizing a neuro-fuzzy model of controllable fluid viscous dampers", Struct. Cont. Health Monit., 13(2-3), 724-747.   DOI   ScienceOn
27 Ruangrassamee, A., Srisamai, W. and Lukkunaprasit, P. (2006), "Response mitigation of the base isolated benchmark building by semi-active control with the viscous-plus-variable-friction damping force algorithm", Struct. Cont. Health Monit., 13(2-3), 809-822.   DOI   ScienceOn
28 Schwaller, A.E. (1999), Motor Automotive Technology Third Edition Delmar Publishers an International, Thomson Publishing Company.
29 Spencer, B.F. and Nagarajaiah, S. (2003), "State of the art of structural control", J. Struct. Eng - ASCE., 129(7), 845-856.   DOI   ScienceOn
30 Wang, Y.P., Liao, W.H. and Lee, C.L. (2001), "A state-space approach for dynamic analysis of sliding structures", Eng. Struct., 23(7), 790-801.   DOI   ScienceOn
31 Xu, Y.L. and Ng, C.L. (2008), "Seismic protection of a building complex using variable friction damper: Experimental investigation", J. Eng. Mech - ASCE., 134(8), 637-649.   DOI   ScienceOn
32 Yang, J.N., Akbarpour, A. and Ghaemmaghami, P. (1987), "New optimal control algorithms for structural control", J. Eng. Mech - ASCE., 113(9), 1369-1387.   DOI   ScienceOn
33 Yang, J.N. and Agrawal, A.K. (2002), "Semi-active hybrid control systems for nonlinear building against nearfault earthquakes", Eng. Struct., 24(3), 271-280.   DOI   ScienceOn
34 Yang, Y.B., Lu, L.Y. and Yau, J.D. (2005), Structure and Equipment Isolation Vibration and Shock Handbook Chapter 22, (Ed. C. W. de Silva), CRC Press, Taylor & Francis Group.
35 Ying, G.X., Ni, Y.Q. and Ko, J.M. (2009), "A semi-active stochastic optimal control strategy for nonlinear structural systems with MR dampers", Smart Struct. Syst., 5(1), 69-79.   DOI