• 제목/요약/키워드: Earth retaining walls

검색결과 163건 처리시간 0.024초

진동대 실험을 통한 흙막이 벽체의 변위 거동 특성 (Displacements Behavior of Retaining Walls by Shaking Table Test)

  • 윤원섭;윤부열;양철규;박연준
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.409-418
    • /
    • 2018
  • In this study, experiments were carried out after fabricating and installing a physical model considering the size of the prototype. In the model test, the number of struts placed on the wall and the applied acceleration were selected as test variables. Two different types of waves, long-period and short-period, were applied with magnitudes of 0.05g, 0.1g, 0.2g, and 0.3g. Measured are displacements at specified points. As a result of the analysis, displacement exceeding the allowable displacement of the wall occurred at an acceleration greater than 0.05g to 0.1g depending on the seismic waves applied. Therefore guidelines have to be established through further studies for aseismic design of earth retaining walls.

압밀주입에 의한 지반개량 특성고찰 (The Evaluation on Behavior of Segmental Grid Retaining Wall by Model Test)

  • 김상수;배우석;이종규
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.162-171
    • /
    • 2006
  • Segmental Grid Retaining Wall is one of the segmental grid retaining walls using headers and stretchers to establish the framework of the wall In this method, grids formed by the intersection of headers and stretchers are generally filled with the gravel to maintain the weight of the wall Therefore, the construction can be carried out with higher speed and much economically when compared with the concrete retaining wall Furthermore, it has high drain capacity, and environmentally friendly aspects also have been pointed out because the possibility of the planting at the front of the wall However, in the segmental grid retaining wall method, the relative movement between the individual headers and stretchers was generally recognized, and stress redistribution in the gravel filling was also observed when subjected to the external loading and self-weight of filling Therefore, it has been thought that the distribution of the earth pressure in the segmental grid retaining wall system differ from that of the concrete retaining wall In this study, the surcharge tests using the scaled model segmental grid retaining wall was carried out to observe the distribution of the earth pressure in the segmental grid retaining wall The earth pressure was measured in the six specified height of wall, and the distribution of the pressure was analyzed. Furthermore, the earth pressure by computation or by the test using the concrete retaining wall was also considered to make comparison

  • PDF

Experimental evaluation of back-to-back anchored walls by double-plates anchors

  • Amir, Najafizadeh;AmirAli, Zad
    • Geomechanics and Engineering
    • /
    • 제31권6호
    • /
    • pp.599-614
    • /
    • 2022
  • One of the methods of stabilizing retaining walls, embankments, and deep excavations is the implementation of plate anchors (like the Geolock wall anchor systems). Back-to-back Mechanically Stabilized Earth (BBMSE) walls are common stabilized earth structures that can be used for bridge ramps. But so far, the analysis of the interactive behavior of two back-to-back anchored walls (BBAW) by double-plates anchors (constructed closely from each other and subjected to the limited-breadth vertical loading) including interference of their failure and sliding surfaces has not been the subject of comprehensive studies. Indeed, in this compound system, the interaction of sliding wedges of these two back-to-back walls considering the shear failure wedge of the foundation, significantly impresses on the foundation bearing capacity, adjacent walls displacements and deformations, and their stability. In this study, the effect of horizontal distance between two walls (W), breadth of loading plate (B), and position of vertical loading was investigated experimentally. In addition, the comparison of using single and equivalent double-plate anchors was evaluated. The loading plate bearing capacity and displacements, and deformations of BBAW were measured and the results are presented. To evaluate the shape, form, and how the critical failure surfaces of the soil behind the walls and beneath the foundation intersect with one another, the Particle Image Velocimetry (PIV) technique was applied. The experimental tests results showed that in this composite system (two adjacent-loaded BBAW) the effective distance of walls is about W = 2.5*H (H: height of walls) and the foundation effective breadth is about B = H, concerning foundation bearing capacity, walls horizontal displacements and their deformations. For more amounts of W and B, the foundation and walls can be designed and analyzed individually. Besides, in this compound system, the foundation bearing capacity is an exponential function of the System Geometry Variable (SGV) whereas walls displacements are a quadratic function of it. Finally, as an important achievement, doubling the plates of anchors can facilitate using concrete walls, which have limitations in tolerating curvature.

석축구조물 및 배면지반의 안정성 검토사례연구 (A Case Study on the Stability Analysis for Masonry Retaining Walls and Backfill)

  • 천병식;여유현;김경민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권1호
    • /
    • pp.149-160
    • /
    • 2001
  • In this paper, the stability analyses were performed for masonry retaining wallls in Seoul subway System. This masonry retaining wallls were reinforced with earth anchor system for the construction, but it was removed after construction. Therefore, the stability of masonry retaining wallls should be checked after the earth anchors removed. For stability analysis of masonry retaining wallls. FDM analysis(FLAC Ver.3.3) and slope stability analysis (SLOPE/W) were performed applying the test results from laboratory and field tests(Schmidt hammer test, cack examination). As conclusion, the tension force of earth anchors should be kept, therefore, substitutional method was required in order to keep the tension force of earth anchor system.

  • PDF

열차하중 작용 시 연직토류벽에 발생하는 수평응력 고찰 (A study on horizontal stress of retaining walls caused by train loading)

  • 김대상;김형근;김기환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.964-972
    • /
    • 2008
  • In the retaining wall design process, track and train loads are usually considered as uniform surcharge loads and strip loads. In this paper, the lateral(horizontal) earth pressure on retaining structures caused by track and train load are calculated using the Boussinesq solution. And also total horizontal force per unit length and the location of the resultant force were estimated with the changes of loading locations and widths of the loadings. The maximum horizontal earth pressure and the location of it for high-speed train load were 11.83kPa and 1.7m at the loading condition 2m away from retaining walls.

  • PDF

Back-to-Back 보강토옹벽의 옹벽폭비에 따른 최적 보강길이비 산정을 위한 수치해석적 연구 (Numerical Analysis for Optimal Reinforcement Length Ratio According to Width-to-Height Ratio of Back-to-Back MSE)

  • 박춘식;김동광
    • 한국지반공학회논문집
    • /
    • 제36권12호
    • /
    • pp.69-76
    • /
    • 2020
  • Back-to-Back 보강토옹벽은 좁은 구간에 양립하는 옹벽의 형식을 가지기 때문에 벽체간의 이격거리에 따라 보강재가 겹치게 되어 보강재 간의 상호작용에 의한 응력 변화와 일체화된 상태에서 전체가 거동하는 문제 등으로 설계단계에서 신중한 접근이 필요하나 현재 국내에 정형화된 설계기준이나 지침이 전무한 상태이다. 본 연구는 이러한 Back-to-Back 보강토옹벽에 대해 옹벽폭 대 높이비(옹벽폭비, Wb/H)에 따른 최적 보강길이비에 대해 고찰하였다. 옹벽폭비는 FHWA 설계기준의 Case II에 해당하는 1.1H, 1.4H, 1.7H, 2.0H, 높이는 일반적으로 가장 많이 적용되고 있는 3.0m, 5.0m, 7.0m, 10.0m를 대상으로 하였으며, 각 조건에서 수치해석을 통해 FHWA 설계기준의 적정성과 옹벽의 높이 및 옹벽폭비에 따른 최적 보강길이비를 제안하였다.

보강토 옹벽용 지오그리드의 현장 내시공성 및 강도 감소계수 평가에 관한 연구 (A Study on the Evaluation of Field Installation Damage and Strength Reduction Factor of Geogrid for Reinforced Retaining Wall)

  • 박주환;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제13권7호
    • /
    • pp.5-12
    • /
    • 2012
  • 최근 국내에서 기존 RC옹벽보다 시공실적이 증가하고 있는 보강토 옹벽은 보강자재, 시공방법, 전면블럭의 형태에 따라 다양하지만 공법에 대한 안전성이 충분히 검증되지 않아 설계와 시공관리에 어려움이 많으며, 보강토 옹벽에 사용되는 보강재 등은 제조사별로 규격과 형상이 다양하고 영세한 업체에서 제작하였거나 일부 값이 싼 품질이 낮은 제품이 수입되고 있지만 이를 설계에 적용할 수 있는 적절한 기준이 제시되지 못하고 있는 실정이다. 이에 본 연구는 보강토 옹벽의 보강재인 옹벽용 그리드에 대하여 현장 내시공성 시험을 통해 다양한 형태의 옹벽용 그리드의 내시공성 감소계수를 제안하고, 국내외 연구결과 분석과 국내 시판되고 있는 제조사별로 제시한 옹벽용 그리드의 물성치를 조사 분석하였다. 결론적으로, 뒤채움재의 입경과 모난 정도의 차이, 입도 분포에 따라 감소계수에 미치는 영향이 크므로 일정규모 이상의 현장에서는 현장내시공성 시험을 거쳐 뒤채움재 별로 차별화된 감소계수를 적용하고, 보강벽체의 활용성에 따라 연성과 강성그리드를 잘 선정하여 적용함으로서 효과적으로 보강토 옹벽의 안전성을 높일 수 있음을 확인하였다.

블록식 보강토 옹벽에서 개별 블록간 거동특성을 고려한 수치해석적 연구 (Numerical Analytic Study considering the Behavior Characteristics between Individual Blocks in Block-Type Retaining Walls)

  • 황성필;박병석;우용훈;박상기;김우석
    • 지질공학
    • /
    • 제31권4호
    • /
    • pp.579-588
    • /
    • 2021
  • 일반 콘크리트 옹벽에 비해 경관성이 우수한 보강토 옹벽이 최근 많이 사용되고 있다. 다양한 재료와 복잡한 현장여건으로 기존 설계 방식만으로는 안정성 확보가 어려운 경우가 발생되고 있다. 이러한 문제를 해결하기 위해 현장여건에 적합한 안정성 분석 방법에 대한 연구를 진행하였다. 본 연구에서는 기존 수치해석과는 다르게 보강토 블록이 개별거동 가능하도록 적용하였으며, 개별 블록거동에 따른 물성치 및 강도 적용을 위하여 블록간 마찰특성과 블록과 보강재의 연결특성에 관한 실규모 시험을 수행하였다. 수치해석을 통해 현장과 동일한 블록조건의 적용 가능성을 확인하였고, 이를 활용하여 다양한 조합의 블록과 보강재의 안정성 검토 및 설계에 활용 가능 할 것으로 판단된다. 또한 외적안정의 범위를 넓혀 안정성을 더욱 확보할 수 있을 것으로 판단된다.

사질토 지반에서 흙막이벽체-지하공간 연속 굴착에 따른 지반거동에 대한 실험적 연구 (Experimental study on the ground movement due to consecutive construction of retaining wall and underground space in cohesionless soil)

  • 박종덕;유정선;김도엽;이석원
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.267-281
    • /
    • 2015
  • 본 연구에서는 흙막이벽과 같은 수직굴착과 터널과 같은 지하공간의 연속적인 굴착에 따른 지반 거동과 토압 변화를 실험적으로 연구하였다. 굴착 단계별로 벽체 거동, 토압 변화, 그리고 지표 침하의 측정이 가능한 길이 160cm, 높이 120cm의 모형 토조를 제작하였다. 실험은 균일하게 조성된 사질토 지반에서 벽체에 임의의 변위를 가하고, 토압 변화와 지표 침하를 확인하는 방식으로 수행하였다. 모형실험은 흙막이벽과 지하공간의 연속적인 시공을 모사하기 위하여 흙막이벽 굴착을 모사하는 우측벽체 10개 및 지하공간 굴착을 모사하는 하부벽체 5개를 순서대로 거동시켜 모사하였다. 실험 결과, 벽체의 주동변위로 감소된 토압이 주변 벽체로 분담되는 아칭현상이 모든 벽체에서 발생함을 확인하였다. 연속되는 시공을 모사한 실험에서 phase마다 아칭현상을 확인할 수 있으나, 하부1단 벽체의 거동 시, 우측10단 벽체는 다른 경우와 달리 토압이 50%정도만 회복됨을 보였다.