• Title/Summary/Keyword: Earth resistivity

Search Result 469, Processing Time 0.031 seconds

Detection of Sea-water Intrusion Caused by Tidal Action Using DC Resistivity Monitoring (전기비저항 모니터링을 이용한 해수침투 파악)

  • Hwang, Hak-Soo;Lee, Sang-Kyu;Ko, Dong-Chan;Kim, Yang-Soo;Park, In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • The 1 $km^2$ area studied is located in Sukchun-ri, Hwasung-koon, the southern part of Kyeonggi-do. Even though this site has been known as a contaminated area caused by seawater intrusions, geophysical and geochemical surveys have never been carried out at the site to determine the extent of the seawater contamination and to investigate whether the seawater intrusion is in progress. The purpose of this study is to determine the extent of seawater contamination and a preferred channel of the seawater intrusion using geophysical methods such as DC resistivity surveys with Schlumberger array and a dipole-dipole array. In order to determine whether the seawater intrusion is in progress in the area, DC resistivity monitoring with Schlumberger array was performed. According to the resistivity map obtained from the inversion of the resistivity data measured with Schlumberger array, the study area is divided into two districts as relatively lowly resistive (less than 30 ohm-m) and highly resistive (more than 30 ohm-m) areas. The distribution of the lowly resistive area is consistent with the distribution of the layer composed of clay minerals, and the resistivity of this layer decreases slowly as approaching to the old seashore. Hydrogeological analysis shows that the clay layer within a distance of about 200 m from the seashore has been already contaminated by sea-water and its electric conductivity is 8 times higher than that of the sand layer covered by the clay layer. According to the results of the 2-dimensional DC resistivity surveys with a dipole-dipole array, there are two preferred channels of the seawater intrusion in the site, and both the channels are in the NW-SE direction from the old seashore. The lowly resistive zone in the southern channel extends to a depth of 80 m. The DC resistivity monitoring with Schlumberger array was carried out along the preferred channel which has the low resistivity Bone (fracture zone) that extended to a depth of 80 m. The time series of apparent resistivity, measured at a distance of 260 m from the old coast line, fluctuates with a period of 12 hours. From these observations, it can be concluded that the seawater intrusion caused by tidal action is still in progress along the fractured zone interpreted by the DC resistivity surveys with a dipole-dipole array.

  • PDF

A Study on the High Frequency Properties of Mn-Zn ferrite with Re2O3(R=Dy, Gd, Ho) Addition (Re2O3(R=Dy, Gd, Ho)첨가에 따른 Mn-Zn ferrite의 고주파 특성에 관한 연구)

  • 최우성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.6
    • /
    • pp.538-548
    • /
    • 2003
  • We studied effects by Re$_2$O$_3$(R=Dy, Gd, Ho) addition on the properties of Mn-Zn ferrite. The doping concentration range from 0.05 wt% to 0.25 wt%. All samples were prepared by standard fabrication of ceramics. With increasing the rare earth oxides, specific density and initial permeability increased on the whole. But, the tendencies such as upper result had the measured value on limitation and characteristics saturated or decreased properties after that. In case of excessive addition of additive beyond some level, initial permeability properties of ferrite have gone down in spite of anomalous grain. With increasing the content of additive, both the real and imaginary component of complex permeability and the magnetic loss (tan$\delta$) increased. Because the increased rate of real component had higher than imaginary component, magnetic loss increased none the less for increasing the real component related with magnetic permeability. But, the magnetic loss of ferrite doped with the rare earth oxides was lower than that of Mn-Zn ferrite at any rate. The small amount of present rare earth oxides in Mn-Zn ferrite composition led to enhancement of resistivity in bulk, and more so in the grain boundary. It was seem to be due to the formation of mutual reaction such as between iron ions and rare earth element ions.

On the Temporal Variability of Geomagnetic Field and Transfer Function at Icheon Observatory (이천관측소에서 측정된 지자기장 및 지자기 전달함수의 시간적 변동성)

  • Lee, Duk-Kee;Kwon, Byung-Doo;Youn, Yong-Hoon;Yang, Jun-Mo
    • Journal of the Korean earth science society
    • /
    • v.25 no.7
    • /
    • pp.604-614
    • /
    • 2004
  • Using three-components geomagnetic data from a permanent geomagnetic observatory in Icheon, we have computed the power spectrum of each geomagnetic component, amplitude, phase and estimation error of transfer function for each day in the 6 months period July 2002${\sim}$December 2002. The temporal variation of power spectrum have random appearances with repeating relative strong and weak magnitude, which is considered as solar activities. However, there is no clear long-term trend. In the case of amplitude, phase and error of transfer function, even though there are some random patterns over the periods of 1000 s and under 100 s, they seem to be comparatively stable without manifest temporal changes. Futhermore, we have estimated electrical field by assuming P$_{1}\;^{0}$ spherical harmonics and then calculated the approximated apparent resistivity for each day. As a result, the variations of resistivity depend on the temporal magnitude of spectral power in horizontal magnetic fields rather than hydrological changes in near surface.

Application of geophysical and geochemical methods to investigation of AMD environment (AMD 환경평가를 위한 지구물리${\cdot}$지구화학탐사의 적용사례)

  • Kim Jisoo;Han Soohyung;Choi Sanghoon;Lee Pyeongkoo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.267-272
    • /
    • 2005
  • Geophysical surveys were performed in three abandoned mines: Jangpoong, Kwangyang, Imchon. The main objectives of the researches include delineating the pathways of leachate from acid mine drainage(AMD), mapping buried rock wastes and tailings, detecting drainage pipes, and investigating the gallery and membrane, if they exist, Geophysical responses were well correlated with the results from water sample data(i.e., pH, EC, heavy metal contents, $SO_4^{-2}$). Main pathways of the leachate were successfully detected in electrical resistivity sections and self-potential(SP) profiles, whereas waste rocks, drainage pipes, and membranes were effectively located by incorporating seismic refraction, electrical resistivity and GPR methods.

  • PDF

Pre-screening technique for MT and GDS data processing based on the spectral power of Electromagnetic field (전자기장의 분광 에너지에 기반한 MT 및 GDS 자료의 전처리 기법 연구)

  • Yang, Jun-Mo;Kwon, Byung-Doo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.253-258
    • /
    • 2006
  • The Korean peninsula has been known to be very difficult to acquire clean MT and GDS data due to its highly industrialization and civilization. In this environment, a pre-screening step selecting data segments with a proper S/N ration is an essential one. This study modified the automatic pre-screening step based on the spectral power of electromagnetic field (RMP) taking account of the situation of the Korean Peninsula. The modified RMP technique was applied to MT data measured at seven sites located in middle part of the peninsula. In the whole sense, the RMP technique considerably improved the connectivity of apparent resistivity and phase curves around the period of 10 sec. In addition, the results processed by the RMP technique showed a very little difference with those derived from manual editing, and the superior performance of it is found especially in the connectivity of apparent resistivity curve.

  • PDF

Estimating the Soil Volume Conversion Factor of Weathered Ground with Consideration of Field Situations

  • Jin, Kyu-Nam;Cho, Gye-Chun;Lee, Jung-Min;Ryu, Hee-Hwan;Park, Sung-Wook
    • Land and Housing Review
    • /
    • v.2 no.2
    • /
    • pp.145-155
    • /
    • 2011
  • It is very important for successful construction to estimate the soil volume conversion factor of domestic weathered ground accurately and reasonably. However, it is very difficult to quantify the weathering degree of weathered ground at the field, so that the soil volume conversion factor used in Korea is often dependent upon the standard of foreign countries. Besides, the soil volume conversion factor of domestic weathered ground has been rarely studied and the use and accuracy of the soil volume conversion factor have been questioned persistingly. This study suggests a simple but robust method for estimating the soil volume conversion factor and measuring the weathering degree reasonably, and attempts to establish the utilization of a soil volume conversion factor measurement system based on experimental and analytical results. We made relationship between electrical resistivity and weathering degree presented from weathering index obtained through laboratory tests using field samples, and an estimation method of in-situ weathering degree for granites and a calculation method of soil volume conversion factor using electrical resistivity. And also, we suggested the photogrametry measurement-equipment system for measuring the volume of cargo box and the application plan of stand equipment and RFID for calculating the earth volume and distinguishing buggies in order to design the measurement system for soil volume conversion factor applicable to the field. Ultimately, the Weathered Earth-work Management Program (WEMP) was developed, so field managers may easily obtain the information about earth volume and soil volume conversion factor at the weathered ground.

Layered-earth Resistivity Inversion of Small-loop Electromagnetic Survey Data using Particle Swarm Optimization (입자 군집 최적화법을 이용한 소형루프 전자탐사 자료의 층서구조 전기비저항 역해석)

  • Jang, Hangilro
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.4
    • /
    • pp.186-194
    • /
    • 2019
  • Deterministic optimization, commonly used to find the geophysical inverse solutions, have its limitation that it cannot find the proper solution since it might converge into the local minimum. One of the solutions to this problem is to use global optimization based on a stochastic approach, among which a large number of particle swarm optimization (PSO) applications have been introduced. In this paper, I developed a geophysical inversion algorithm applying PSO method for the layered-earth resistivity inversion of the small-loop electromagnetic (EM) survey data and carried out numerical inversion experiments on synthetic datasets. From the results, it is confirmed that the PSO inversion algorithm could increase the inversion success rate even when attempting the inversion of small-loop EM survey data from which it might be difficult to find a best solution by applying the Gauss-Newton inversion algorithm.

Analysis of distortion effect of resistivity data due to 3D geometry of fill dam (필댐의 3차원 기하 효과에 따른 전기비저항 왜곡 효과 분석)

  • Oh Seokhoon;Kim Hyoung-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.55-58
    • /
    • 2005
  • Low resistivity zone is observed at the lower part of a CFRD (Concrete Face Rockfill Dam). Generally, CFRD tends not to have any saturated zone within the body, but the result of resistivity survey shows that it is possible for the dam to be saturated under 20m depth with water. The level of reservoir was under 10m from the crest. We suspect that this result may come from the wrong 2D inversion process ignoring the 3D geometry of dams. For the analysis of possibility of distortion by different geometry, we perform the 3D forward modeling for the dam and apply the 2D inversion process. And then we check the point of traditional interpretation of resistivity data. By the analysis, it is found that the result of 2D inversion process of 3D geometry of dams, seems to have deep relation with the reservoir level, and the complex 3D structure hide some internal electrical anomaly of dams from resistivity information.

  • PDF

Monitoring $CO_2$ injection with cross-hole electrical resistivity tomography (시추공간 전기비저항 토모그래피를 이용한 $CO_2$ 주입 모니터링)

  • Christensen, N.B.;Sherlock, D.;Dodds, K.
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.44-49
    • /
    • 2006
  • In this study, the resolution capabilities of electrical resistivity tomography (ERT) in the monitoring of $CO_2$ injection are investigated. The pole-pole and bipole-bipole electrode configuration types are used between two uncased boreholes straddling the $CO_2$ plume. Forward responses for an initial pre-injection model and three models for subsequent stages of $CO_2$ injection are calculated for the two different electrode configuration types, noise is added and the theoretical data are inverted with both L1- and L2-norm optimisation. The results show that $CO_2$ volumes over a certain threshold can be detected with confidence. The L1-norm proved superior to the L2-norm in most instances. Normalisation of the inverted models with the pre-injection inverse model gives good images of the regions of changing resistivity, and an integrated measure of the total change in resistivity proves to be a valid measure of the total injected volume.

Modified Electrical Resistivity Survey for Leakage Detection of a Waterside Concrete Barrage (콘크리트 수변구조물의 누수 탐지를 위한 변형된 전기비저항 탐사 연구)

  • Lee, Bomi;Oh, Seokhoon;Im, Eunsang
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.115-124
    • /
    • 2015
  • A modified electrical resistivity survey has been suggested and applied to a leakage detection problem of concrete barrage. We suggest the modified electrical resistivity methods using electrodes floating on the water and apply line current sources instead of conventional point current sources in order to facilitate simple analysis. In addition, the study introduced the following three variations of modified electrode array: Direct potential array, Parallel potential array and Cross potential array. These arrays were tested and investigated through numerical experiment, physical model experiment and geophysical field exploration in order to verify their applicability to the water leakage detection of a concrete barrage. When water leakage occurred, all kind of array operations demonstrated distinct changes of aspects of potential difference in graphs obtained by not only the numerical and physical model experiments but also geophysical field exploration. Therefore, this modified electrode arrays of electrical resistivity survey, which has been adapted to the concrete barrage, has been found to be a useful method to detect water leakage.