• Title/Summary/Keyword: Earth fault

Search Result 425, Processing Time 0.03 seconds

Analysis of Subsurface Geological Structures and Geohazard Pertinent to Fault-damage in the Busan Metropolitan City (부산시 도심지의 지하 지질구조와 단층손상과 관련된 지질위험도 분석)

  • Son, Moon;Lee, Son-Kap;Kim, Jong-Sun;Kim, In-Soo;Lee, Kun
    • Economic and Environmental Geology
    • /
    • v.40 no.1 s.182
    • /
    • pp.87-101
    • /
    • 2007
  • A variety of informations obtained from satellite image, digital elevation relief map (DEM), borehole logging, televiewer, geophysical prospecting, etc were synthetically analyzed to investigate subsurface geological and structural characteristics and to evaluate geohazard pertinent to fault-damage in the Busan metropolitan city. It is revealed that the geology is composed of the Cretaceous andesitic$\sim$dacitic volcanics, gabbro, and granitoid and that at least three major faults including the Dongrae fault are developed in the study area. Based on characteristics of topography, fault-fractured zone, and isobath maps of the Quaternary sediments and weathered residuals of the basement, the Dongrae fault is decreased in its width and fracturing intensity of damaged zone from south toward north, and the fault is segmented around the area between the Seomyeon and Yangieong junctions. Meanwhile, we drew a geohazard sectional map using the five major parameters that significantly suggest damage intensity of basement by fault, i.e. distance from fault core, TCR, RQD, uniaxial rock strength, and seismic velocity of S wave. The map is evaluated as a suitable method to express the geological and structural characteristics and fault-damaged intensity of basement in the study area. It is, thus, concluded that the proposed method can contribute to complement and amplify the capability of the present evaluation system of rock mass.

Comparative Numerical Analysis of Elastic Modulus according to Distribution and Content of Breccia in Fault Core (수치해석을 이용한 단층핵 내 각력의 배열 형태 및 함량에 따른 탄성계수의 비교·분석)

  • Yun, Hyun-Seok;Song, Gyu-Jin;Moon, Seong-Woo;Kim, Chang-Yong;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.387-393
    • /
    • 2015
  • Fault breccia, produced by fracturing and comminution of host rock during fault activity, is a common component within fault cores. Fault breccia may display a preferred orientationin accordance with the sense of motion on the fault. Here we use a numerical analysis technique to study the effects of the distribution and content of breccia in fault core on the elastic moduli. The analytical models are grouped into those in which breccias display a preferred orientation within fault core and those in which breccias are randomly oriented. The breccia compositions considered here are granite and shale, and the breccia contents are 10 wt%, 20 wt%, and 30 wt%. Our results show that for all the cases considered, differences in the deformation moduli fall within the range 0.1%~1.1% and differences in the elastic moduli fall within the range 0.02~0.4 MPa. Thus, the distribution and content of fault breccia have almost no effect on the elastic moduli.

A Study on Separation Distance Calculation Model for Limitation of Earth Potential Rise Nearby Tower Footings (송전철탑 부근의 대지전위 억제를 위한 이격거리 산정모델 연구)

  • Choi, Jong-Kee;Cho, Hwan-Gu;Kim, Tai-Young;Lee, Dong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.179-183
    • /
    • 2008
  • In case of a line-to-ground fault at transmission lines, a portion of fault current will flow into the earth through the footings of the faulted tower causing electrical potential rise nearby the faulted tower footings. In this situation, any buried pipelines or structures nearby the faulted tower can be exposed to the electrical stress by earth potential rise. Although many research works has been conducted on this phenomena, there has been no clear answer of the required separation distance between tower footings and neary buried pipeline because of its dependancy on the soil electrical charactersics of the concerned area and the faulted system. In this paper, an analytical formula to calculate the requried sepeartion distance from the faulted tower has been derived.

Characterization of Fault Kinematics based on Paleoseismic Data in the Malbang area in the Central Part of the Ulsan Fault Zone (고지진학적 자료를 이용한 울산단층대 중부 말방지역에서의 단층운동 특성 해석)

  • Park, Kiwoong;Prasanajit, Naik Sambit;Gwon, Ohsang;Shin, Hyeon-Cho;Kim, Young-Seog
    • Journal of the Korean earth science society
    • /
    • v.43 no.1
    • /
    • pp.151-164
    • /
    • 2022
  • According to the records of historical and instrumental earthquakes, the southeastern part of the Korean Peninsula is considered the highest seismic activity area. Owing to recent reports of numerous Quaternary faults along the Yangsan and Ulsan fault zones, paleoseismological studies are being actively conducted in these areas. The study area is located in the central part of the Ulsan fault zone, where the largest number of active faults have been reported. Based on lineament and geomorphic analysis using LiDAR images and aerial photographs, fault-related landforms showing topographic relief were observed and a trench survey was conducted. The trench length 20 m, width 5 m, depth 5 m is located approximately 300 m away to the northeast from the previously reported Malbang fault. From the trench section, we interpreted the geometric and kinematic characteristics of the fault based on the deformed features of the Quaternary sedimentary layers. The attitude of the reverse fault, N26°W/33°NE, is similar to those of the reported faults distributed along the Ulsan fault zone. Although a single apparent displacement of approximately 40 cm has been observed, the true displacement could not be calculated due to the absence of the slickenline on the fault plane. Based on the geochronological results of the cryogenic structure proposed in a previous study, the most recent faulting event has been estimated as being earlier than the late Wurm glaciation. We interpreted the thrust fault system of the study area as an imbrication structure based on the previous studies and the fault geometry obtained in this additional trench. Although several previous investigations including many trench surveys have been conducted, they found limited success in obtaining the information on fault parameters, which could be due to complex characteristics of the reverse fault system. Additional paleoseismic studies will contribute to solving the mentioned problems and the comprehensive fault evolution.

Subsurface Structure of the Yeongdong Basin by Analyzing Aeromagnetic and Gravity Data

  • Kim, Kyung-Jin;Kwon, Byung-Doo
    • Journal of the Korean earth science society
    • /
    • v.23 no.1
    • /
    • pp.87-96
    • /
    • 2002
  • Aeromagnetic and gravity data were analyzed to delineate the subsurface structure of the Yeongdong basin and its related fault movement in the Okcheon fold belt. The aeromagnetic data of the total intensity (KIGAM, 1983) were reduced to the pole and three dimensional inverse modeling, which considers topography of the survey area in the modeling process, were carried out. The apparent susceptibility map obtained by three dimensional magnetic inversion, as well as the observed aeromagnetic anomaly itself, show clearly the gross structural trend of the Yeongdong basin in the direction on between $N30^{\circ}E$ and $N45^{\circ}E$. Gravity survey was carried out along the profile, of which the length is about 18.2 km across the basin. Maximum relative Bouguer anomaly is about 7 mgals. Both forward and inverse modeling were also carried out for gravity analysis. The magnetic and gravity results show that the Yeongdong basin is developed by the force which had created the NE-SW trending the magnetic anomalies. The susceptibility contrast around Yeongdong fault is apparent, and the southeastern boundary of the basin is clearly defined. The basement depth of the basin appears to be about 1.1 km beneath the sea level, and the width of the basin is estimated to be 7 km based on the simultaneous analysis of gravity and magnetic profiles. There exists an unconformity between the sedimentary rocks and the gneiss at the southeastern boundary, which is the Yeongdong fault, and granodiorite is intruded at the northwestern boundary of the basin. Our results of gravity and magnetic data analysis support that the Yeongdong basin is a pull-apart basin formed by the left-stepping sinistral strike-slip fault, which formed the Okcheon fold belt.

Reactivated Timings of the Yangsan Fault in the Yeonghae area based on the Mineralogical Characteristics of Fault Clays (단층암 점토광물 특성에 기초한 영해지역 양산단층의 단층활동연대 결정)

  • Hong, Seongsik;Sim, Ho;Choi, Sung-Ja;Song, Yungoo
    • Economic and Environmental Geology
    • /
    • v.53 no.6
    • /
    • pp.645-654
    • /
    • 2020
  • We present the K-Ar age dating results of <0.1㎛ fraction of the selected fault rocks from the Yangsan fault in the Yeonghae area. Based on the mineralogical characterization, the <0.1㎛ fractions were mostly composed of 1Md illite polytype, or I-S interstratified mineral, which should be formed by fault activation. Therefore, we determined the timings of fault activation events by analyzing K-Ar age-dating for the <0.1㎛ fractions. Accordingly, the activation timings of Yangsan Fault in the Yeonghae area were determined as 45.5±1.1 Ma, 50.9±1.2 Ma, 58.2±1.3 Ma, 60.8±1.4 Ma, 65.3±1.6 Ma, 66.8±1.5 Ma, 67.1±1.5 Ma, and 75.1±1.7 Ma. These results indicate that at least 5-times of major fault events occurred in the Yangsan fault from late Mesozoic to Cenozoic Era. In the outcrop, age dating results tend to be younger age from the location of the oldest sample(75.1±1.7 Ma) toward to the both sides. From the results, it suggests that the fault activation extends from the location of oldest age saple to both sides. This geochronological research of the multiple fault activation ages for the Yangsan Fault will provide crucial information for establishing the tectonic evolution model in the southeastern part of the Korean Peninsula.

Case Study on the Pre-Service Earth Science Teachers' Faults Discrimination on Geological Map using Eye Tracker (시선 추적기를 활용한 지질도에서 예비 지구과학교사들의 단층 판별에 대한 사례 연구)

  • Woong Hyeon Jeon;Duk Ho Chung;Chul Min Lee
    • Journal of the Korean earth science society
    • /
    • v.44 no.3
    • /
    • pp.210-221
    • /
    • 2023
  • The purpose of this study is to evaluate the content knowledge and problem solving process used by pre-service earth science teachers while discriminating faults on geological maps. For this, we collected and evaluated data on fixation duration and gaze plot, while pre-service earth science teachers (N=12) solved the problem on faults interpretation using an eye tracker (Tobii Pro Glass 2 model). The results were as follows. First, most of the pre-service earth science teachers know the concepts of the normal and reverse fault but they do not know the procedural knowledge essential for fault interpretation on geological maps. Second, the pre-service earth science teachers did not draw a geological cross-sectional map to interpret the fault on the geological map and interpreted the fault based on two-dimensional information collected from the geological map rather than three-dimensional information. Therefore, it is essential to improve the teaching and learning environment so that pre-service earth science teachers who will become earth science teachers in the future can learn procedural knowledge essential to comprehend natural phenomena including understanding natural phenomena. The results of this study can substantially help organize a new earth science curriculum or develop materials on teachers' education in the future.

Study on the Distribution of Electromagnetic Force for 154 kV Power Transmission Cable on Dual Underground Lines by Normal and Earth Fault Current (지중 2회선 154 kV 송전케이블의 정상 및 지락고장에 따른 전자기력 분포에 관한 연구)

  • Kim, Hui Min;Kim, So Young;Im, Sang Hyeon;Park, Gwan Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • The goal of this study is the size and distribution of the electromagnetic force generated by the current flowing through the second underground line of 154kV power transmission cables by using electromagnetic finite element analysis. So we interpret how mutually electromagnetic force has an effect on the comparable judgement of Trefoil, Duct and Flat, which shows in a numerical arrangement. 154kV OF 1200SQ Cable 1.281km not only is applicable to modeling for underground transmission cable but also examine the effect of line to line, phase to phase and size and direction of the electromagnetic force preparing for the occurrence of normal state and single-phase earth fault, which are arranged in trefoil, duct and flat formation between sections. As showing how the trajectory, and size distribution of the electromagnetic force translate as the arrangement of the cables when a steady-state current and a fault current flows on the underground cables, I hope that when Underground transmission is designed, this data will be useful information.

Crack Propagation in Earth Embankment Subjected to Fault Movement (단층 운동시 댐 파괴 거동 해석)

  • 손익준
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1988.06c
    • /
    • pp.3-67
    • /
    • 1988
  • Model studies on the response of homgeneous earth embankment dams subjected to strike-slip fault movement have been penomed via centrifuge and finite element analysis. The centrifuge model tests have shown that crack development in earth embankment experiences two major patters: shear failure deep inside the embankment and tension failure near the surface. The shear rupture zone develops from the base level and propagates upward continuously in the transverse direction but allows no open leakage chnnel. The open tensile cracks develop near the surface of the embankment, but they disappear deep in the embankment. The functional relationship has been developed based on the results of the centrifuge model tests incorporating tile variables of amount of fault movement, embankment geometry, and crack propagation extent in earth des. This set of information can be used as a guide line to evaluate a "transient" safety of the duaged embankment subjected to strike-slip fault movement. The finite element analysis has supplemented the additional expluations on crack development behavior identified from the results of the centrifuge model tests. The bounding surface time-independent plasticity soil model was employed in the numerical analysis. Due to the assumption of continuum in the current version of the 3-D FEM code, the prediction of the soil structure response beyond the failure condition was not quantitatively accurate. However, the fundamental mechanism of crack development was qualitatively evaluated based on the stress analysis for the deformed soil elements of the damaged earth embankment. The tensile failure zone is identified when the minor principal stress of the deformed soil elements less than zero. The shear failure zone is identified when the stress state of the deformed soil elements is at the point where the critical state line intersects the bounding surface.g surface.

  • PDF

Reactivated Timings of Inje Fault since the Mesozoic Era (인제단층의 중생대 이 후 재활동 연대)

  • Khulganakhuu, Chuluunbaatar;Song, Yungoo;Chung, Donghoon;Park, Changyun;Choi, Sung-Ja;Kang, Il-Mo;Yi, Keewook
    • Economic and Environmental Geology
    • /
    • v.48 no.1
    • /
    • pp.41-49
    • /
    • 2015
  • Recently developed illite-age-analysis(IAA) approach was applied to determine the fault-reactivated events for the Inje fault that cut through Precambrian biotite granitic gneiss with NNE-SSW trend in the middle of Korean peninsula. Three distinct fault-reactivated events of shallow crustal regime were recognized using the combined approach of optimized illite-polytype quantification and K-Ar age-dating of clay fractions separated from 4 fault clay samples: $87.0{\pm}0.12Ma$, $65.5{\pm}0.05$ and $66.6{\pm}1.38Ma$, $45.6{\pm}0.15Ma$, respectively. As well, $2M_1$ illite ages of 193~196 Ma and $254.3{\pm}6.96Ma$ were discernible, which may be related to the fault-activated time in the relatively deep crust. The study results suggest that the Inje fault would be firstly formed at $254.3^{\circ}$ ${\ae}6.96Ma$ and sporadically reactivated in shallow regime since about 87 Ma. These reactivation events in shallow regime might be due to the Bulguksa orogeny that would be strongly influenced in Korean peninsula at that time.