• Title/Summary/Keyword: Earth Resistivity Survey

Search Result 212, Processing Time 0.035 seconds

Dipole-Dipole Resistivity Survey on the Side of Han River near Nanjido Landfill (난지도에 인접한 한강변에서의 쌍극자-쌍극자 전기탐사)

  • Lee, Kiehwa;Kwon, Byung-Doo;Oh, Seok-Hoon;Kim, Cha-Seop
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.335-343
    • /
    • 1996
  • The dipole-dipol electrical resistivity survey was conducted to investigate the probable contamination of the Han river by leachate from the near-by Nanjido Landfill. The survey line of 3 km was set along the unpaved road toward the Han river. For the convenience of the field work, the survey line was divided into four segments. The complete two-dimensional resistivity section was constructed by connecting the inversion result of each segment. Gravity survey was also carried out along the profile parallel to the resistivity line. Near surface resistivity generally appeared to be of very low value in most part of the survey area and the boundary between the alluvium layer and underlying basement rocks is well discriminated on the resistivity section. These results agree well with those of the preceding Schlumberger depth sounding made at adjacent area by Lee and fun (1995). The variation of thickness of the alluvium layer delineated by gravity anomaly profile also correlates well with the result of the resistivity survey on the qualitative basis. The problem of contamination by leachate from the Nanjido Landfill, where various waste materials have been dumped without any proper treatment facilities, has been remains unsolved yet. Therefore, we present the most probable passages of leachate flow based on the survey results and have briefly discussed about measure for contamination control. Considering the thickness of alluvium and the possible existence of fractured zone, the middle point between 1st and 2nd landfill and the midst of 1st landfill are the most hazardous regions to make leachates flow into the Han river. Since large amounts of leachates are observed from the test wells located on the lines extending from the border between the 1st and 2nd landfill and the middle of the lst landfill, contamination protection barriers are strongly recommended near these regions.

  • PDF

A COMPARATIVE ANALYSIS BETWEEN GROUND SUBSIDENCE AT ABANDONED UNDERGROUND COAL MINE AND ELECTRICAL RESISTIVITY SURVEY RESULTS USING GIS

  • Ahn, Seung-Chan;Lee, Sa-Ro;Kim, Ki-Dong
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.728-731
    • /
    • 2006
  • Ground subsidence near abandoned underground coal mines has become a serious social problem in Korea. The purpose of this study is to perform a comparative analysis between the ground subsidence area and the electrical resistivity measured by field survey at Samcheok City. A raster database composed of ground subsidence areas and electrical resistivity data was constructed for GIS. To analyze correlation between the two constructed raster datasets, we used a frequency ratio model. The results show that low and high electrical resistivity anomaly zones coincide with the existing subsidence areas. We infer that the high anomaly zone means saturated and low anomaly zone means vacant. It suggests that electrical resistivity might be a useful factor for analyzing ground subsidence hazard zone.

  • PDF

Electric and Electromagnetic Surveys of the Hongseong Fault Zone (홍성 단층대에서의 전기, 전자 탐사 연구)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Park, Gye-Soon;Oh, Seok-Hoon;Lee, Choon-Ki
    • Journal of the Korean earth science society
    • /
    • v.24 no.4
    • /
    • pp.361-368
    • /
    • 2003
  • We have investigated the electric resistivity structure of the fault zone located in the Hongseong area where a big earthquake with M 5.0 occurred in 1978. Usually, Electric and Electromagnetic methods are broadly operated in the field of engineering works since these methods are effective to understand the distribution of geological weak zones - fault or fracture zones. We have conducted the dipole-dipole array resistivity method and MT(magnetotelluric) method and interpreted the resistivity distribution of the fault zone with the aid of various inversion methods. An MT survey was performed at 18 points along a 2.9 km survey line perpendicular to the fault line and a magnetic dipole source was used to enhance the S/N ratio in the high frequency. A Electric dipole-dipole array resistivity survey with the dipole length of 50 meters was carried out perpendicular to the fault. In view of two survey results, the fault marks the boundary between two opposite resistivity structures, especially the low resistivity zone is exhibited deeply through the prospective fault line. The result that the low resistivity zone is located at the center of the fault zone corresponds with the fact that the fault zone of the Hongseong area is active. We expect these results to provide basic information about the physical properties of fault zones in Korea.

A Study on the Correlation of Resistivity and Rock Quality (전기비저항과 암반등급의 상관관계에 대한 고찰)

  • 권형석;신중호;황세호;백환조;김기석;김종수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.81-88
    • /
    • 2001
  • Electrical resistivity is one of physical property of the earth and measured by electrical resistivity survey, electrical resistivity logging and laboratory test. Recently, electrical resistivity is widely used in determination of rock quality in road and railway tunnel design. To get more reliable rock quality data from electrical resistivity, it needs a lot of test and study on correlation of resistivity and rock quality. Firstly, we did rock property test in laboratory, such as uniaxial compressive strength(UCS), p wave velocity, Young's modulus and electrical resistivity. We correlate each test results and we found out that electrical resistivity has exponentially related to UCS and P wave velocity and linearly related to Young's modulus. And we accomplished electrical resistivity survey in field site and carried out electrical resistivity logging at in-situ area. Also we peformed rock classification, such as RQD, RMR and Q-system and we correlate electrical resistivity to rock classification results. We found out that electrical resistivity logging data are highly correlate to RQD, Q and RMR. Also we found out that electrical resistivity survey data are lower than electrical resistivity logging data when there are faults or fractures. And it cause electrical resistivity survey data to lowly correlate to RQD, Q and RMR.

  • PDF

A Case Study for Rock Mass Classification using Geophysical Exploration (물리탐사에 의한 터널구간의 암반등급 산정)

  • 김기석;권형석;김종훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.06b
    • /
    • pp.119-137
    • /
    • 2003
  • Electrical resistivity is one of physical property of the earth and measured by electrical resistivity survey, electrical resistivity logging and laboratory test. Recently, electrical resistivity Is widely used In determination of rock quality in road and railway tunnel design. To get more reliable rock quality data from electrical resistivity, it needs a lot of test and study on correlation of resistivity and rock quality. Firstly, we did rock property test In laboratory, such as uniaxial compressive strength(UCS), P wave velocity, Young's modulus and electrical resistivity. We correlate each test results and we found out that electrical resistivity has exponentially related to UCS and P wave velocity and linearly related to Young's modulus. And we accomplished electrical resistivity survey in field site and carried out electrical resistivity togging at In-situ area. Also we performed rock classification, such as RQD, RMR and Q-system and we correlate electrical resistivity to rock classification results. We found out that electrical resistivity logging data are highly correlate to RQD, Q and RMR. Also we found out that electrical resistivity survey data are lower than electrical resistivity logging data when there are faults or fractures. And it cause electrical resistivity survey data to lowly correlate to RQD, Q and RMR.

  • PDF

Application of Electrical Resistivity Survey For Contaminant Evaluation at Uncontrolled Landfills

  • Lee Seong-Soon;Yoon Hee-Sung;Lee Kang-Kun;Lee Jin-Young;Kim Chang-Gyun;Yu Young-Chul
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.432-435
    • /
    • 2006
  • To evaluate geology and extent of leachate migration around the landfills, electrical resistivity survey were conducted in area of uncontrolled landfills in Cheonan and Wonju. The Cheonan landfill is located above the paddy fields and the resistivity survey lines were crossed to confirm possible pollution of the paddy fields by leakage of the landfill leachate. In Wonju, the landfill and the downgradient paddy fields are divided by a concrete barrier wall. At the bottom of the landfill, there is a leachate settlement system but has not been in operation. And a total of 4 survey line installed (1 parallel and 3 perpendicular to mean groundwater flow direction). According to the resistivity survey results, the landfill leachate in Cheonan appeared to be restricted only within the interior of the landfill, not to migrate into the subsurface of the paddy fields. These results are well consistent with electrical conductivity values of groundwaters obtained from a periodic analysis of water qualities. In Wonju, however, it was inferred that the leachate emanating from the landfill migrated beneath the abandoned leachate settlement system and it would reach the downgradient paddy field.

  • PDF

A marine deep-towed DC resistivity survey in a methane hydrate area, Japan Sea (동해의 메탄 하이드레이트 매장 지역에서의 해양 심부 견인 전기비저항 탐사)

  • Goto, Tada-Nori;Kasaya, Takafumi;Machiyama, Hideaki;Takagi, Ryo;Matsumoto, Ryo;Okuda, Yoshihisa;Satoh, Mikio;Watanabe, Toshiki;Seama, Nobukazu;Mikada, Hitoshi;Sanada, Yoshinori;Kinoshita, Masataka
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.52-59
    • /
    • 2008
  • We have developed a new deep-towed marine DC resistivity survey system. It was designed to detect the top boundary of the methane hydrate zone, which is not imaged well by seismic reflection surveys. Our system, with a transmitter and a 160-m-long tail with eight source electrodes and a receiver dipole, is towed from a research vessel near the seafloor. Numerical calculations show that our marine DC resistivity survey system can effectively image the top surface of the methane hydrate layer. A survey was carried out off Joetsu, in the Japan Sea, where outcrops of methane hydrate are observed. We successfully obtained DC resistivity data along a profile ${\sim}3.5\;km$ long, and detected relatively high apparent resistivity values. Particularly in areas with methane hydrate exposure, anomalously high apparent resistivity was observed, and we interpret these high apparent resistivities to be due to the methane hydrate zone below the seafloor. Marine DC resistivity surveys will be a new tool to image sub-seafloor structures within methane hydrate zones.

Electrical Resistivity Survey for Evaluation of Grouting Effect in Earth Dam (그라우팅에 의한 댐체의 보강효과 평가를 위한 전기비저항탐사)

  • Im, Eun-Sang;Oh, Seok-Hoon;Kim, Young-Kyung;Oh, Byung-Hyun
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.4
    • /
    • pp.455-462
    • /
    • 2006
  • In this paper, we used the electrical resistivity survey as a simple and reasonable technique to evaluate the effectiveness of grouting. And, a mechanism was also analyzed to understand how the electrical resistivity is affected by the loss of fine material in the core of a dam. From this mechanism, it was confirmed that electrical resistivity value of the damage section may be up or down depending on the survey conditions. This result seems to be contrary to the previous study that electrical resistivity of the damage zone become alway low. To clarify what was investigated, the electrical resistivity before and after grouting was compared and analyzed. As the result, it was concluded that grouting effectiveness was successfully assessed by electrical resistivity survey.

  • PDF

Proposed Survey Steps for Investigation of Land-Creeping Susceptibility Areas: A Focus on Geophysical Mapping of the Yongheung-dong, Pohang, Korea

  • Kim, Jeong-In;Lee, Sun-Joong;Kim, Kwan-Soo;Lee, Jae-Eun;Sa, Jin-Hyun;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.269-281
    • /
    • 2021
  • Land creeping is the imperceptibly slow, steady, downward movement o f slope-forming soil or rock. Because creep-related failures occur frequently on a large scale without notice, they can be hazardous to both property and human life. Korea Forest Service has operated the prevention and response system from land creeping which has been on the rise since 2018. We categorized and proposed three survey steps (e.g., preliminary, regional, detailed) for investigation of creeping susceptibility site with a focus on geophysical mapping of a selected test site, Yongheung-dong, Pohang, Korea. The combination of geophysical (dipole-dipole electrical resistivity tomography and reciprocal seismic refraction technique, well-logging), geotechnical studies (standard penetrating test, laboratory tests), field mapping (tension cracks, uplift, fault), and comprehensive interpretation of their results provided the reliable information of the subsurface structures including the failure surface. To further investigate the subsurface structure including the sliding zone, we performed high-resolution geophysical mapping in addition to the regional survey. High-resolution seismic velocity structures are employed for stability analysis because they provided more simplified layers of weathering rock, soft rock, and hard rock. Curved slip plane of the land creeping is effectively delineated with a shape of downslope sliding and upward pushing at the apex of high resistive bedrock in high-resolution electrical resistivity model with clay-mineral contents taken into account. Proposed survey steps and comprehensive interpretation schemes of the results from geological, geophysical, and geotechnical data should be effective for data sets collected in a similar environment to land-creeping susceptibility area.

An Electrical Resistivity Monitoring in Embankment (제방에서의 전기비저항 모니터링)

  • Ahn, Taegyu;Ko, Chihye;Jeong, Yujeong;Lee, Heuisoon;Song, Sung-Ho;Yong, Hwan-Ho
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.59-67
    • /
    • 2015
  • An electrical resistivity survey is widely conducted for the safety management of embankment. In this study we investigated how a tidal variation affects the interpretation of electrical resistivity monitoring data of the embankment located in west coast. We monitored the variation of electrical resistivity on the coastal embankment where there was a high tidal variation for 3 days in every 3 hours. Electrical resistivity monitoring data showed a variation of resistivity distribution in specific area according to the time, which demonstrated some correlation with a tidal height variation. Therefore, we highly recommend that a tidal effect be considered when electrical resistivity survey is conducted on the embankment where there is a high tidal variation. For further study, we need a long term electrical resistivity monitoring and analyzing on tidal variation.