• Title/Summary/Keyword: Earth Housing

Search Result 83, Processing Time 0.024 seconds

A Study on Architectural Features and Current Status of Earth Housing (흙주거의 건축적 특성 및 이용현황 분석)

  • Kim Jeong-Gyu;Jeong Joo-Seong
    • Journal of the Korean housing association
    • /
    • v.17 no.1
    • /
    • pp.97-105
    • /
    • 2006
  • The purposes of this study are to find out the current status and features of earth housing, and to explore users' level of satisfaction and needs of improvement about earth housing. Primary findings are as follows: (1) The area of earth housing is generally 25-34 pyong and the construction cost of earth housing is usually 3,000,000-3,400,000 won per pyong. (2) The age of earth house users is generally forties, fifties, and sixties. And their occupation is usually retiree and farmer. The age of earth based pension users is generally twenties and thirties. (3) The construction method of earth housing is usually earth brick structure reinforced with wood structure and earth brick structure(adobe). (4) The finish of outer wall is generally earth brick laying and earth plaster. And the finish of inner wall is usually wall paper and earth plaster. Roof tile and asphalt shingle is frequently observed as roof finish. (5) Users' satisfaction about earth housing is investigated high level. Especially, the satisfaction degrees about faculty of humidity control, stink elimination, prevention from sick house syndrome, support for psychological stabilization and deep sleep are observed very highly. (6) Reduction of construction cost and prevention of crack is investigated as needs of improvement about earth housing.

A Study on the Residential Character and Consciousness of Housing Environment in Earth Housing (흙주거의 거주특성과 주거환경 의식에 관한 연구)

  • Jeong Joo-Seong;Kim Jeong-Gyu;Oh Yang-Ki
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.47-54
    • /
    • 2006
  • The purpose of this study is to investigate residential characters and consciousness about housing environment concerned with earth housing, and to suggest basic data reflectible on the planning of earth housing. Residential characters and consciousness are investigated with the people lived in forty seven earth housings located in nationwide scale through interviews and questionnaire. As a result, it is shown that a reason of health like sick house syndrome, residential environments such as ventilation and lighting, site environment such as neighbor and greenfield are very influential elements to the consciousness of inhabitants. Meanwhile, approximation of residential area, the connection with public facilities including medical service, educational and commercial conditions, additionally, preparation of disaster and crime prevention in a viewpoint of safety are pointed out as relatively weak ones. It means that earth housing is not systematically fixed as a residential site because it is personally progressed by small number of peoples having different reasons. For the improvement of systematic housing environment, development and proposition of various model are needed on earth housing and its site.

Behavior of Lateral Earth Pressure around the Underpass Constructed by the STS Construction Method

  • Jin, Kyu-Nam;Kim, Hyo-Jin;Sim, Young-Jong
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.271-279
    • /
    • 2016
  • Recently developed trenchless construction methods ensure stability for the ground settlement by inserting steel pipes along the underpass section and integrating steel pipes before ground excavation to form pipe-roof. This study is to confirm the reinforcing effect of pipe-roof by measuring lateral earth pressure acting on the underpass constructed by the STS (Steel Tube Slab) construction method. For this purpose, lateral earth pressure was measured at the left and right side of the pipe-roof after installing earth pressure cells. As a result, lateral earth pressure was measured with considerable reduction because the integrated pipe-roof shared surcharge. Therefore, economic design for the underpass could be expected by sharing design load by pipe-roof. In addition, construction cost was analyzed according to the design-load sharing ratio by pipe-roof. As pipe-roof shares design load by 40%, the total construction cost can decrease by almost 10% in the case of four-lane underpass.

A Study on the Measurement of Energy in a case of the Earth Bermed Housing (복토주택(覆土住宅)의 실례(實例)를 통한 에너지 측정(測定) 연구(硏究))

  • Shon, Jang-Yeul;Lee, Shi-Woong
    • Solar Energy
    • /
    • v.6 no.2
    • /
    • pp.33-42
    • /
    • 1986
  • The purpose of this paper is to research the performance of the energy in a case of the earth bermed House designed to be suitable for Korean situation in comparison with a conventional housing. The result of this study can be summerized as follows; 1) Heating energy of the earth bermed house is saved 40.1% than that of the conventional housing in Korea. 2) The time-lag of the earth bermed house is 57 minutes longer than that of a conventional housing on account of the thermal capacity, so the earth bermed house has much more satisfactory thermostatic mitigation effect rather than the conventional housing.

  • PDF

The Analysis on the Evaluation Items of Korea Green Building Certification Criteria by the Case Studies of Collective Housing (국내 공동주택 부문의 친환경건축 인증 평가 항목 및 사례 분석)

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.93-100
    • /
    • 2013
  • Many countries have made their best to protect the earth from global warming and to find solutions for the reduction of carbon dioxide emittion and energy consumption. Especially, buildings have emitted over 40% of carbon dioxide against whole quantities emitted to the earth. Therefore, the reduction of carbon dioxide emitted from buildings require to save the earth environment. Energy consumption of buildings in Korea has reached 24% of total energy quantities, and energy consumption of collective housing has been continuously increasing. So, Korea government has also executed the Green Building Certification Criteria(GBCC). The GBCC evaluates the 8 types of buildings - collective housing, office, school, etc - to certificate the green building. In this paper, the evaluation items of collective housing in GBCC were reviewed to be used as the reference data for future revisions by the case studies. According to the results of this study, current version of GBCC requires additional revisions about the evaluations of energy consumption monitoring, commissioning and existing building.

A Study on the Indoor Thermal Environment of House Using Earth Brick Wall (황토벽돌벽 주택의 실내온열환경에 관한 연구)

  • 이재윤
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.25-32
    • /
    • 2004
  • The purpose of this study is to understand the indoor thermal environment in the earth brick wall building what is called a ecological Architecture. To investigate thermal performances of the earth brick walls, it measured indoor and outdoor air temperature, relative humidity, globe temperature and PMV in reference house. The result of this study were summarized as the followings; 1) When the outdoor average air temperature was $21.8^{\circ}$, livingroom was $24.9^{\circ}$, kitchen was $25.1^{\circ}$ and 2nd floor room was $25.6^{\circ}$ at 150 cm height from the floor. 2) Although the average outdoor relative humidity was 78%, the livingroom was 67.5%. 3) As the air temperature difference between at the top and bottom was $0.6^{\circ}$ in living room, this value was below 1 % of PPD by ASHRAE Handbook. 4) Predicted Mean Vote(PMV) by ISO-7730 was +0.41.

A Study on Standard and Tendency of Landscape Housing -Focused on the Rural Landscape Authenticated Housing of Chuncheon City, Gangwon Province- (경관주택의 선정기준과 성향에 관한 연구 -강원도 춘천시 농촌경관인증주택을 중심으로-)

  • Sim, Jae-Hack;Yoon, Young-Hwal;Choi, Jang-Soon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.11 no.3
    • /
    • pp.19-28
    • /
    • 2009
  • This research aimed at showing an improvement direction in the future by analyzing the tendency to select a rural landscape housing and the characteristics centering around the data of the landscape-authenticated housing executed in Chuncheon City from 2005 to 2008. For 4 years, 25 houses in all were authenticated by Chuncheon City after being selected as landscape housing. As the result of analyzing the authenticated 25 housing, lots of landscape houses were located in natural green areas, and small-scale houses of $99m^2$ or less in the house size were preferred. The structures introducing the nature-friendly materials such as wood, yellow earth and clay continued to increase in the house structure. And in the selection of the authenticated houses, the landscape architecture and the harmony with the surrounding environment had a big effect on the selection.

  • PDF

Estimating the Soil Volume Conversion Factor of Weathered Ground with Consideration of Field Situations

  • Jin, Kyu-Nam;Cho, Gye-Chun;Lee, Jung-Min;Ryu, Hee-Hwan;Park, Sung-Wook
    • Land and Housing Review
    • /
    • v.2 no.2
    • /
    • pp.145-155
    • /
    • 2011
  • It is very important for successful construction to estimate the soil volume conversion factor of domestic weathered ground accurately and reasonably. However, it is very difficult to quantify the weathering degree of weathered ground at the field, so that the soil volume conversion factor used in Korea is often dependent upon the standard of foreign countries. Besides, the soil volume conversion factor of domestic weathered ground has been rarely studied and the use and accuracy of the soil volume conversion factor have been questioned persistingly. This study suggests a simple but robust method for estimating the soil volume conversion factor and measuring the weathering degree reasonably, and attempts to establish the utilization of a soil volume conversion factor measurement system based on experimental and analytical results. We made relationship between electrical resistivity and weathering degree presented from weathering index obtained through laboratory tests using field samples, and an estimation method of in-situ weathering degree for granites and a calculation method of soil volume conversion factor using electrical resistivity. And also, we suggested the photogrametry measurement-equipment system for measuring the volume of cargo box and the application plan of stand equipment and RFID for calculating the earth volume and distinguishing buggies in order to design the measurement system for soil volume conversion factor applicable to the field. Ultimately, the Weathered Earth-work Management Program (WEMP) was developed, so field managers may easily obtain the information about earth volume and soil volume conversion factor at the weathered ground.

Comparison of earth pressure around pipe-roof between UPRS and front-jacking method (UPRS 공법과 프론트잭킹 공법의 파이프루프 주변 현장토압 계측결과 비교)

  • Sim, Youngjong;Jin, Kyu-Nam;Song, Ki-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.5
    • /
    • pp.513-522
    • /
    • 2015
  • This study is to confirm the effect of pre-installed pipe-roof by measuring earth pressure acting on the underpass. In recently developed trenchless methods pre-inserted steel pipes before ground excavation to form pipe-roof are connected each other with re-bars and filled with mortar. In this study, focusing on the Upgraded Pipe Roof Structure method (UPRS) and Front-Jacking, earth pressure around pipe-roof is measured after insertion of steel pipe to ensure the effect of earth pressure reduction. In case of the UPRS earth pressure is considerably reduced because of the reinforced effect of pipe-roof. In case of the Front-Jacking in which the whole underpass structure is pushed into the ground, earth pressure is not reduced as expected, because the pre-installed pipes are not needed to be reinforced.

A Study on Planning Element of Symbiotic Housing (환경공생주택(環境共生住宅)의 계획요소(計劃要素) 고찰(考察))

  • Kim, Young-Seok;Choi, Ki-Young
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.165-172
    • /
    • 2003
  • Quantitative planning element and qualitative planning instruction which are required for planning and evaluating environment-friendly building are accessed in previous studies. In this study, the concept of symbiotic housing is introduced for upgrading existing planning elements, so as to study the planning elements collectively. This study can be summarized as below: (1) Planning elements for saving energy and using resources effectively are added in order to preserve the earth environment. (2) In order to harmonize with neighboring environment more, sunshine duration of neighboring buildings is considered; streets and village view are harmonized; space in-between is prepared. (3) For healthy and amenity residential environment, following items are added, improved pleasantness of inside and outside space; improved amenity and health of housing; and, co-dwelling with large scope. Besides, the necessity of residents' agreement is proposed to induce residents' participation, which has not been mentioned before.

  • PDF