• Title/Summary/Keyword: Early loading

Search Result 252, Processing Time 0.029 seconds

A Study on the Leading/Unloading Time Prediction of the Ballast Tank (밸러스트 탱크의 급수/배수 시간 예측에 관한 연구)

  • Kim H. I.;Kim M. U.;Choi D. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.33-36
    • /
    • 2004
  • The ballast tank of a ship is a system that realizes the required shipping condition and controls the draft of a ship. The loading/unloading of the ballast tank is frequently operated during navigation and the accurate prediction of the loading/unloading time is very important. A numerical algorithm that predicts the loading/unloading time of the ballast tank has been developed and applied to the prediction of the loading/unloading time of the ballast tank with various piping systems. This algorithm can be useful in optimizing the ballast tank system in early design stage.

  • PDF

Early loading using tempo denture with solitary attachment system, implant supported overdenture with prefabricated bar attachment system on Mandibular edentulous patient: A case report (하악 완전 무치악 환자에서 solitary attachment를 연결한 임시 보철물로 조기 부하를 가한 후, 조립식 바를 이용한 최종 임플란트 지지 피개의치 제작증례)

  • Park, Do-Hyeon;Lee, So-Hyoun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of the Korean dental association
    • /
    • v.54 no.1
    • /
    • pp.39-48
    • /
    • 2016
  • SFI-bar is prefabricated bar system and can be assembled at chairside without soldering or welding, thus reducing bone loss, costs and time. A 53-year-old male patient, who had severely absorbed mandible, hoped to wear a stable mandiblular denture. Four implants were placed in the extraction site of canine and 1st molar. Early loaded temporary denture with solitary type attachment was delivered 3 weeks after surgery. 3 month later, SFI-bar was connected and adjusted at chairside. Then, implant overdenture using SFI-bar was delivered. This case report showed that a satisfactory clinical result was achieved by 4-implant-supported overdenture using the SFI-Bar system in a mandibular edentulous patient.

  • PDF

A STUDY ON THE EFFECTS OF EARLY LOADING ON THE SURROUNDING BONE TISSUE OF THE DENTAL IMPLANTS (치과임플랜트 매식후 조기기능이 임플랜트 주위골조직에 미치는 영향에 관한 연구)

  • Park, Hui-Un;Yang, Jae-Ho;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.101-127
    • /
    • 1993
  • The purpose of this study was to observe the effects of early loading on the surrounding bone tissue of the implants. 12 ITI HS implants (8 mm) were inserted on the mandible at 3 mongrel dogs. The implants were divided into two groups; the functional group was functioned with crown, and nonfunctional group was functioned without crown. After 3 and 5 months animals were sacrificed and specimens were examined using radiography, light microscopy, scanning electron microscopy. The following results were obtained. 1. On light microscopic and scanning electron microscopic examination, the difference in the amounts of bone attachment between 3 months loaded and unloaded implants were a little. Sometimes more bone attachment were observed in loaded implants. 2. Many osteoids surrounded the fibrous connective tissues indicating of bone remodeling were observed along the outer surface of the implants. 3. On clinical, radiographic, microscopic examination, epithelial downgrowths were not observed and bone attachments to the outer surface of the implants were observed in 3 months loaded and unloaded implants with good oral hygiene. 4. Epithelial downgrowths and crater-like bone resorptions were observed on 5 months loaded and unloaded implants with poor oral hygiene. 5. Many inflammatory cells in the epithelial tissue were packed in the hollow on 5 months loaded implants.

  • PDF

Evaluation of the Osseointegration in Immediatedly Loaded Implants in the Premolar Socket of the Mandible in Beagles (비글견에서 아래턱 작은어금니 Implant의 즉시 부하에 대한 평가)

  • Kim, Dae-Jin;Kim, Jung-Eun;Seong, Yun-Sang;Jang, Hwan-Soo;Kwon, Young-Sam;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.1
    • /
    • pp.55-61
    • /
    • 2010
  • Tooth restoration with implant placement have been interested in modern veterinary dentistry. It is important to reduce the interval between the tooth extraction and the insertion of the implants, to determine the restoration time after implant placement in dogs The aim of the this study was to compare the bone mineral apposition rate of immediately loaded implants with an unloaded control during the early healing state in the artificial extraction mandible. In four Beagles, two premolar sockets (PM2 and PM3) of the both sides of the mandible were installed with a one stage titanium mini-implant with a length of 11 mm and a diameter of 3.37 mm immediately after tooth extraction. Provisional restroration was given to implants, 3 weeks after implant placement in the left side (immediate loading) and 12 weeks in the right side (delayed loading), respectively. Radiographic and histologic examinations were performed. Radiographic evaluation revealed no significant difference between two groups. Bone-implant contact was $47.1{\pm}8.9$ in immediate loading and $50.2{\pm}8.2$ in delayed loading, interthread bone density was $78.7{\pm}10.9$ in immediate loading and $73.1{\pm}15.5$ in delayed loading, and peri-implant bone density was $95.4{\pm}7.1$ in immediate loading and $95.0{\pm}5.2$ in delayed loading, respectively. Three histologic analyses showed no significant difference between delayed and immediate loading. Followed by this study, the immediate loading of implants insterted into fresh extraction sockets after tooth extraction could be considered in veterinary dentistry.

Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading

  • Kim, Seong-Beom;Yun, Pil-Young;Kim, Sang-Yun;Yi, Yang-Jin;Kim, Ji-Yun;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.396-403
    • /
    • 2016
  • PURPOSE. Early loading of implant can be determined by excellent primary stability and characteristic of implant surface. The implant system with recently improved surface can have load application 4-6 weeks after installing in maxilla and mandible. This study evaluated the effect of healing period to the stability of hydrophilic tapered-type implant at maxillary posterior area. MATERIALS AND METHODS. This study included 30 patients treated by hydrophilic tapered-type implants (total 41 implants at maxilla) and classified by two groups depending on healing period. Group 1 (11 patients, 15 implants) was a control group and the healing period was 12 weeks, and Group 2 (19 patients, 26 implants) was test group and the healing period was 6 weeks. Immediately after implant placement, at the first impression taking, implant stability was measured using Osstell Mentor. The patients also took periapical radiographs after restoration delivery, 12 months after restoration and final followup period. The marginal bone loss around the implants was measured using the periapical radiographs. RESULTS. All implants were survived and success rate was 97.56%. The marginal bone loss was less than 1mm after 1 year postoperatively except the one implant. The stabilities of the implants were not correlated with age, healing period until loading, insertion torque (IT), the diameter of fixture and the location of implant. Only the quality of bone in group 2 (6 week) was correlated with the stability of implant. CONCLUSION. Healing period of 6 weeks can make the similar clinical prognosis of implants to that of healing period of 12 weeks if bone quality is carefully considered in case of early loading.

Hydroxyapatite-coated implant: Clinical prognosis assessment via a retrospective follow-up study for the average of 3 years

  • Jung, Jun-Hong;Kim, Sang-Yun;Yi, Yang-Jin;Lee, Bu-Kyu;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.85-92
    • /
    • 2018
  • PURPOSE. This research evaluated clinical outcomes of two types of hydroxyapatite (HA)-coated implants: OT (Osstem TS III-HA, Osstem implant Co., Busan, Korea) and ZM (Zimmer TSV-HA, Zimmer dental, Carlsbad, USA). MATERIALS AND METHODS. The research was conducted on 303 implants (89 of OT, 214 of ZM), which were placed from January 16, 2010 to December 20, 2012. The prognosis was evaluated in terms of success rates, survival rates, annual marginal bone loss, and implant stability quotients (ISQ). The samples were classified into immediate, early, conventional, and delayed groups according to the loading time. RESULTS. Overall, there were no significant differences between OT and ZM in success rates, survival rates, and annual marginal bone loss, except for the result of secondary stability. OT showed $77.83{\pm}8.23ISQ$, which was marginally higher than $76.09{\pm}6.90ISQ$ of ZM (P<.05). In terms of healing periods, only immediate loading showed statistically significant differences (P<.05). Differences between OT and ZM were observed in terms of two indices, the annual marginal bone loss ($0.17{\pm}0.58mm/year$ < $0.45{\pm}0.80mm/year$) and secondary stability ($84.36{\pm}3.80ISQ$ > $82.48{\pm}3.69ISQ$) (P<.05). OT and ZM did not have any statistically significant differences in early, conventional, and delayed loading (P>.05). CONCLUSION. OT (97.75%) and ZM (98.50%) showed relatively good outcomes in terms of survival rates. In general, OT and ZM did not show statistically significant differences in most indices (P>.05), although OT performed marginally better than ZM in the immediate loading and 1-stage surgery (P<.05).

Results of immediate loading for implant restoration in partially edentulous patients: a 6-month preliminary prospective study using SinusQuickTM EB implant system

  • Kim, Jong-Hwa;Kim, Young-Kyun;Yi, Yang-Jin;Yun, Pil-Young;Lee, Hyo-Jung;Kim, Myung-Jin;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.136-139
    • /
    • 2009
  • STATEMENT OF PROBLEM. Many dental clinicians are concerned about immediate loading of inserted implants. However, there have been few clinical studies surveying the success rates of immediate loading, based on Korean implant systems. PURPOSE. The aim of this study was to evaluate the outcome of immediate functional loading of the implant ($SinusQuick^{TM}$EB, Neobiotech Co., Seoul, Korea) in partially edentulous maxilla or mandible. MATERIAL AND METHODS. Total 15 implants were placed. Within 2 weeks after implant insertion, provisional implant-supported fixed partial dentures were delivered to the patients. Quantitatively, marginal bone loss was measured at the time of immediate loading, after 3-months of continued loading and at the last follow-up. The mean follow-up period was 4.8 months. RESULTS. Mean marginal bone loss from implant surgery to early loading, 3-months follow-up and last follow-up was $0.03\pm0.07$ mm, $0.16\pm0.17$ mm and $0.29\pm0.19$ mm. No implant failed up to 6 months after insertion, resulting in a 100% survival rate. CONCLUSION. Immediate loading exhibited high success rate in partial edentulism for up to 6 months. Well-controlled long term clinical studies with large sample size are necessary to confirm this finding.

Recent advances in dental implants

  • Hong, Do Gia Khang;Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.33.1-33.10
    • /
    • 2017
  • Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

The effect of loading time on the stability of mini-implant (교정력 부하시기에 따른 교정용 미니 임플란트의 안정성)

  • Lee, Seung-Yeon;Cha, Jung-Yul;Yoon, Tae-Min;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.149-158
    • /
    • 2008
  • Objective: The purpose of this study was to investigate the stability of mini-implants in relation to loading time. Methods: A total of 48 mini-implants (ORLUS, Ortholution, Korea) were placed into the buccal alveolar bone of the mandible in 8 male beagle dogs. Orthodontic force (200-250gm) was applied immediately for the immediate loading group while force application was delayed for 3 weeks in the delayed loading group. For the subsequent loading periods (3, 6, 12 weeks), BIC (bone implant contact) and BV/TV (bone volume/total volume) and mobility test were carried out. Results: The immediate loading group showed no changes in BIC from 3 to 12 weeks, while the delayed loading group showed a significant increase in BIC between 3 and 12 weeks (p<0.05). The BV/TO of the delayed loading group significantly increased from 6 to 12 weeks of loading (p<0.05), while the BV/TV of the immediate loading group decreased from 3 to 12 weeks of loading. However, there was no significant difference in BV/TV between experimental groups. The mobility of the immediate loading group was not significantly different from that of the delayed loading group after 12 weeks of loading (p<0.05). Conclusions: These results showed that immediate loading does not have a negative effect on the stability of mini-implants compared to the early loading method in both the clinical and histomorphometric point of view.

Retrospective Clinical Study of Immediate or Early Loading of Implants (Original Article 1 - 즉시 혹은 조기하중 임프란트에 관한 후향적 연구)

  • Lee, Seong-Yeon;Kim, Young-Kyun;Yun, Pil-Young;Yi, Yang-Jin;Yeo, In-Sung
    • The Journal of the Korean dental association
    • /
    • v.48 no.2
    • /
    • pp.119-126
    • /
    • 2010
  • Introduction. In this study, we applied the immediate loading to implant using temporary prosthesis, and compared the treatment results by each placement site, amongst pre-loading period. The study was intended to search for occurrence of complications and the amount of marginal bone resorption. Materials and Methods. We retrospectively reviewed the medical records of 99 cases of implants from 29 patients who were treated at Seoul National University Bundang Hospital from September 2003 to September 2008. We grouped all the cases by placement arches and pre-loading periods, and subdivided each group by placement site(anterior/posterior), type of prosthesis(full-mouth cross splinting/Partial multiple splinting, Single). Results. In the cases of anterior maxilla, the average amounts of marginal bone resorption showed $1.71{\pm}0.71mm$ in group 1, and $1.44{\pm}0.69mm$ in group 2, which means they revealed no statistically significant difference between group 1 and group 2(p=0.646). In the cases of posterior maxilla, the average amounts of marginal bone resorption showed $1.25{\pm}0.72mm$ in group 1, and $1.14{\pm}1.15mm$ in group 2, which means they were not statistically significant. In the cases of anterior mandible, there was no cases classified as group 4, but the average amounts of marginal bone resorption in group 3 showed $1.38{\pm}0.79mm$. In the cases of posterior mandible, Group 3 showed $1.39{\pm}0.64mm$, and group 4 showed $1.84{\pm}1.19mm$ as amounts of marginal bone resorption, which means they revealed no statistically significant difference between group 3 and group 4(P=0.210). The survival rate of group1 was 97.14%, 92.1% of group3, and 100% of group 2 and group4. According to each type of prosthesis, each average amount of marginal bone resorption revealed no statistically significant difference in maxi11a(p=0.575) in mandible(p=0.206). Conclusion. It is concluded that the marginal bone resorption and the rate of complications might not be affected by placement sites and pre-loading periods. The marginal bone resorption and the rate of complications might vary as different bone quality of placement site and implant system, diameter, length, etc. It is suggested that the proper placement of immediate loading implants decreases the whole treatment period and any inconvenience occurred to patients.