• 제목/요약/키워드: EVAPORATION

검색결과 3,553건 처리시간 0.027초

액적 표면에서 증발 및 응축을 고려한 곡면 형상 액적 제거장치의 제거 효율에 대한 수치 해석 (Numerical Analysis on Removal Efficiency of Water Droplets in a Curved Vane Mist Eliminator with Consideration of Evaporation and Condensation at Surface of Droplets)

  • 송동근
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.135-143
    • /
    • 2016
  • Removal of water contents in a gas is needed in industrial field of gas processing related on energy production/conversion, and environmental treatment. Inertial separators are economic devices for separating droplets from the gas stream. For accurate understanding of removal process in a curved vane mist eliminator, a numerical model including turbulent dispersion, evaporation and condensation of water vapor at surface of droplets is required. A two-stage curved vane mist eliminator has been modeled, and fluid flow of mixture of air and water vapor and droplet trajectories were solved simultaneously with taking into account two-way coupling. Removal efficiency of droplets with various inlet condition of relative humidities (RH, 40%, 90%, and 100%) were compared. As RH increased, the effect of evaporation decreased and inertial separation efficiencies of droplets obtained increased especially for droplets of diameter below 10 micrometers.

Development of Heat Transfer and Evaporation Correlations for the Turbulent Natural Convection in the Vertical Channel by Using Numerical Analysis

  • Kang, Han-Ok;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.532-541
    • /
    • 1996
  • Theoretical and numerical study on heat transfer and evaporation in the vertical channel has been carried out and basic correlations have been derived for the heat transfer evaluation of PCCS. Analysis program was developed with low-Reynolds-number k-$\varepsilon$ model and surface transfer rates were calculated for the turbulent natural convection in the vertical channel. In relation to dry cooling by buoyancy-driven air, first, the system parameters which govern overall heat transfer rate are determined through the adequate nondimensionalization procedure. After comparison with existing experimental data, numerical results are used to derive heat transfer correlation by sensitivity calculations. In relation to wet cooling by falling water film, numerical analysis are carried out for evaporation process with real film surface conditions and evaporation correlation is derived through analogy concept and correction factors.

  • PDF

고온조건에서 콘크리트 부재의 온도전이 (Beat Transfer Analysis of Concrete Members under High Temperature)

  • 이태규;김혜욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1536-1541
    • /
    • 2009
  • When water inside the concrete member evaporates by high temperature, the evaporation heat which absorbs surrounding temperature occurs. The rate of increment of the internal temperature in concrete is reduced due to the evaporation heat in spite of continuously increasing external temperature. In this paper, the prediction method of internal temperature of high strength concrete members considering the evaporation heat under the high temperature is presented. Finite element method is employed to facilitate thermal analysis for any position of member. And the thermal characteristics models of high strength concrete affected by high temperature are proposed. To demonstrate the validity of this numerical procedure, the prediction by the proposed algorithm is compared with the test results of other researchers. The proposed algorithm shows a good agreement with the experimental results including the phenomenon that temperature is lost by the evaporation heat.

  • PDF

기화식 석유버너의 설계기술 향상 연구 (Study on the Enhancement of Design Technology for the Evaporation Pot Type Kerosene Burner)

  • 심성훈;김석준;길상인;홍용주;윤진한;김인규;김영수
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1998년도 제17회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.47-57
    • /
    • 1998
  • Characteristics of evaporation, flame propagation at moment of ignition and steady state combustion, and flow characteristics of combustible mixture have been investigated by experiments and computational simulation for the evaporation pot type kerosene burner. The results show how to design the evaporation pot in order to minimize the sticking of residual tar, and also indicate that symmetrical flame propagation along the flame ring from the kernel of ignition is achieved by modication of the shape of ignition part. In the case of steady state combustion, the uniform distribustion of flame at each flame hole is accomplished by proper modification of the piping instruments. The improved design of the structure and parts of the kerosene burner make up enhancement of flame stability and considerable reduction of CO and bad smell emission at moment of ignition.

  • PDF

레이저 용접시 분광학적 수법에 의한 증발입자의 거동과 플라즈마 물성의 계측 (Evaporating Particle Behaviors and plasma Parameters by Spectroscopic Method in laser Welding)

  • 김윤해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.514-522
    • /
    • 1999
  • The laser-induced plasma affects greatly on the results of welding process. moreover selective evaporation loss of alloying elements leads to change in chemical composition of weld metal as well as the mechanical properties of welded joint. this study was undertaken to obtain a fundamental knowledge of pulsed laser welding phenomena especially evaporation mechanism of different aluminum alloys. The intensities of molecular spectra of AlO and MgO were different each other depeding on the power density of a laser beam Under the low power density condition the MgO band spectrum was predominant in intensity while the AlO spectra became much stronger with an increase in the power density. These behaviors have been attributed to the difference in evaporation phenomena of Al and Mg metals with different boiling points and latent heats of vaporization. The time-averaged plasma temperature and electron number density were determined by spectroscopic methods and consequently the obtained temperature was $3,280{\pm}150K$ and the electron number density was $1.85{\times}10^{19}\;l/m^3$.

  • PDF

R407C의 온도구배와 과열도가 증발기 성능에 미치는 영향 (Effects of the Temperature Glide and Superheat of R407C on the Performance of Evaporator)

  • 김창덕;전창덕;이진호
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.852-859
    • /
    • 2003
  • R407C is considered as an alternative refrigerant of R22 for air conditioners. An experiment was carried out to investigate the characteristics of the evaporation heat transfer and pressure drop for refrigerant R407C flowing in a fin-and-tube heat exchanger used for commercial air-conditioning unit. The experimental data were useful in analyze the effects of the temperature glide and superheat for R407C. Test were conducted at the conditions of inlet refrigerant evaporation temperature of 7$^{\circ}C$, inlet air relative humidity of 50%, and refrigerant mass fluxes varying from 150 to 250 kg/m$^2$s. Representative results show that the heat exchanger performance for R407C evaporation is significantly affected by the change of the flow pattern from two-phase to super-heated vapor flow.

냉동기 펌프다운 운전성능에 관한 연구 (A Study on Pump Down Operation Performance of Refrigerator)

  • 김철수;정한식;정효민
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.964-970
    • /
    • 2006
  • Vapor compression refrigerators have much critical variables such as the controls of temperature and pressure switches, control durations and operating hours of electronic valves. This study compares and analyzes the data which is obtained from system controlling of the evaporation temperatures which are generally used in automatic pump down operating systems. Through this study, the automatic evaporation control operation system will be more ideal for the system to keep the proper temperature distribution depending on the purpose of evaporation side. The automatic pump down control operation is more appropriate for the system to aim at the effective use of evaporation side without using the temperature difference. And this test will be proved that the changes at the low pressure side didn't have significant impacts on the high pressure side.

화학증착 및 증발-산화법에 의한 알루미나 복합분리막의 제조 및 투과특성 (Preparation and Permeation Characteristics of Alumina Composite Membranes by CVD and Evaporation-Oxidation Process)

  • 안상옥;최두진;현상훈;정형진;유광수
    • 한국세라믹학회지
    • /
    • 제30권8호
    • /
    • pp.678-684
    • /
    • 1993
  • Alumina composite membranes were prepared by chemical vapor deposition and evaporation-oxidation process. For CVD process, deposition was carried out using aluminum-tri-isopropoxide at 35$0^{\circ}C$, 2 torr by heterogeneous reaction, and for evaporation-oxidation process, alumina composite membranes were prepared by evaporation of aluminum and dry oxidation at 80$0^{\circ}C$. As deposition time increases, water flux and N2 gas permeability of the composite membranes prepared by both processes were reduced. Applying gas permeation model, permeability and cracking possibility of top layer were evaluated.

  • PDF

X-선 중심 가광 초신성 잔해 : 성간운 증발과 열전도 모델 (CENTRALLY PEAKED X-RAY SNRS : CLOUD EVAPORATION AND THERMAL CONDUCTION)

  • 최승언;정현철;박병건
    • 천문학논총
    • /
    • 제14권2호
    • /
    • pp.69-78
    • /
    • 1999
  • We present the results of one-dimensional numerical simulations of SNR evolution in the in­homogeneous medium considering the effects of the evaporation of the cloud and the thermal conduction. We have included the effects of changing evaporation rate as a function of cloud size and the ambient temperature so that the clouds could be evaporated completely before they reach the center of the SNR. The heat conduction markedly changes the density distribution in the remnant interior. To explain the observed morphologies of the centrally peaked X-ray SNRs(for example W44), the maximal thermal conduction is required. However, this is unlikely due to the magnetic field and the turbulent motion. The effects of the evaporation of the cloud and the thermal conduction described here may explain the class of remnants observed to have centrally peaked X-ray emmision.

  • PDF

대형 저압 증발식 조수기 개발 (A Development Study on the Evaporation Type Large Fresh Water Generator)

  • 김병덕;송치성;김경근;김종헌;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권4호
    • /
    • pp.1-12
    • /
    • 1994
  • Most merchant ships are supplied with the only essential fresh water from a port for economical cargo transportation and the reduction of a nevigation expense. And the deficient fresh water for a voyage is produced by fresh water generator with the various exhaust energy generated in the engine room on a voyage. At present, an evaporation type fresh water generator are extensively used on ship because the operating cost of it is lower than that of a reverse osmosis pressure type. This study introduce a development results on the large evaporation type fresh water generator enable to be used for large merchant ships. It is accomplished the performance test using the developed large fresh water generator.

  • PDF