Abstract
R407C is considered as an alternative refrigerant of R22 for air conditioners. An experiment was carried out to investigate the characteristics of the evaporation heat transfer and pressure drop for refrigerant R407C flowing in a fin-and-tube heat exchanger used for commercial air-conditioning unit. The experimental data were useful in analyze the effects of the temperature glide and superheat for R407C. Test were conducted at the conditions of inlet refrigerant evaporation temperature of 7$^{\circ}C$, inlet air relative humidity of 50%, and refrigerant mass fluxes varying from 150 to 250 kg/m$^2$s. Representative results show that the heat exchanger performance for R407C evaporation is significantly affected by the change of the flow pattern from two-phase to super-heated vapor flow.
Keywords
R407C; Temperature glide; Superheat; Evaporation; Pressure drop;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Heat transfer prediction of air-to-refrigerant two-phase flow boiling of alternatives to HCFC-22 inside air/refrigerant enhanced surface tubing /
[ Sami,S.M.;Grell,J. ] / Journal of Energy Research   ScienceOn
2 Performance test of a screw compressor type chiller using R407C with shell and tube heat exchangers /
[ Ahn,Y.S.;Lee,D.Y.;Kim,Y.I.;Kim,Y.C.;Nam,I.W. ] / Proceedings of the SAREK
3 Montreal Protocol on Substance that Deplete the Ozone Layer /
[] / Final Act, United Nations Environment Programme
4 Flow boiling heat transfer characteristics of R-407C ternary refrigerant mixtures /
[ Oh,J.T. ] / The Magazine of the SAREK   과학기술학회마을
5 Describing uncertainties in single sample experiments /
[ Kline,S.J.;McClinetock,F.A. ] / Mechanical Engineering
6 An experimental study on the performance of a window system air-conditioner using R407C and R410B /
[ Kim,M.H.;Shin,J.S.;Kim,K.J. ] / Korean Journal of Air-Conditioning and Refrigerating Engineering
7 Horizontal flow boiling of R22 and R407C in a 9.52mm micro-fin tube /
[ Kuo,C.S.;Wang,C.C. ] / Applied inside Thermal Engineering   ScienceOn
8 Flow boiling heat transfer characteristics of pure and mixed refrigerant /
[ Han,J.U.;Kim,S.J.;Jung,D.S.;Kim,Y.I. ] / Proceedings fo the SAREK
9 A study thermal perfomance of air-cooled heat exchangers using alternative refrigerant /
[ Ebisu,T.;Kasai,D.;Torikoshi,K. ] / 33rd National Heat Transfer Symposium of Japan
10 /
[ McLinden,M.O;Klein,S.A;Lemmon,E.W.;Peskin,A.P. ] / Thermodynamic and transport properties of refrigerants and refrigerant mixtures database(REFPROP) (Ver. 6.01)
11 Experimental study on evaporation and condensation heat transfer enhancement for R-407C using herringbone heat transfer tube /
[ Ebisu,T.;Torikoshi,K. ] / ASHRAE Transaction, Symposia
12 /
[ ASHRAE ] / Fundamental Handbook(SI)