• Title/Summary/Keyword: EVALUATION

Search Result 82,293, Processing Time 0.096 seconds

Evaluating efficiency of Coaxial MLC VMAT plan for spine SBRT (Spine SBRT 치료시 Coaxial MLC VMAT plan의 유용성 평가)

  • Son, Sang Jun;Mun, Jun Ki;Kim, Dae Ho;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.313-320
    • /
    • 2014
  • Purpose : The purpose of the study is to evaluate the efficiency of Coaxial MLC VMAT plan (Using $273^{\circ}$ and $350^{\circ}$ collimator angle) That the leaf motion direction aligned with axis of OAR (Organ at risk, It means spinal cord or cauda equine in this study.) compare to Universal MLC VMAT plan (using $30^{\circ}$ and $330^{\circ}$ collimator angle) for spine SBRT. Materials and Methods : The 10 cases of spine SBRT that treated with VMAT planned by Coaxial MLC and Varian TBX were enrolled. Those cases were planned by Eclipse (Ver. 10.0.42, Varian, USA), PRO3 (Progressive Resolution Optimizer 10.0.28) and AAA (Anisotropic Analytic Algorithm Ver. 10.0.28) with coplanar $360^{\circ}$ arcs and 10MV FFF (Flattening filter free). Each arc has $273^{\circ}$ and $350^{\circ}$ collimator angle, respectively. The Universal MLC VMAT plans are based on existing treatment plans. Those plans have the same parameters of existing treatment plans but collimator angle. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively. The calculation grid is 0.2 cm and all plans were normalized to the target V100%=90%. The indexes of evaluation are V10Gy, D0.03cc, Dmean of OAR (Organ at risk, It means spinal cord or cauda equine in this study.), H.I (Homogeneity index) of the target and total MU. All Coaxial VMAT plans were verified by gamma test with Mapcheck2 (Sun Nuclear Co., USA), Mapphan (Sun Nuclear Co., USA) and SNC patient (Sun Nuclear Co., USA Ver 6.1.2.18513). Results : The difference between the coaxial and the universal VMAT plans are follow. The coaxial VMAT plan is better in the V10Gy of OAR, Up to 4.1%, at least 0.4%, the average difference was 1.9% and In the D0.03cc of OAR, Up to 83.6 cGy, at least 2.2 cGy, the average difference was 33.3 cGy. In Dmean, Up to 34.8 cGy, at least -13.0 cGy, the average difference was 9.6 cGy that say the coaxial VMAT plans are better except few cases. H.I difference Up to 0.04, at least 0.01, the average difference was 0.02 and the difference of average total MU is 74.1 MU. The coaxial MLC VMAT plan is average 74.1 MU lesser then another. All IMRT verification gamma test results for the coaxial MLC VMAT plan passed over 90.0% at 1mm / 2%. Conclusion : Coaxial MLC VMAT treatment plan appeared to be favorable in most cases than the Universal MLC VMAT treatment planning. It is efficient in lowering the dose of the OAR V10Gy especially. As a result, the Coaxial MLC VMAT plan could be better than the Universal MLC VMAT plan in same MU.

Evaluation of Sodium Intake and Relationship between Sodium Intake and the Bone Mineral Density of Female University Students (중부 지역 여대생에서 음식섭취빈도조사지를 이용한 나트륨 섭취량 평가 및 나트륨 섭취와 골밀도와의 관련성 조사)

  • Bae, Yun-Jung;Yeon, Jee-Young
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.5
    • /
    • pp.625-636
    • /
    • 2011
  • The purpose of this study was to evaluate the relationship between bone health and sodium intake in female university students using a dish frequency questionnaire (DFQ 125), anthropometric checkups, food records for 3 days, and ultrasound measurement of calcaneus bone mineral density. Subjects were divided into two groups: normal (n=196) and osteopenia (n=52). There were no significant differences in age or height between the two groups. The average weight, body mass index, and body fat in the normal group were significantly higher than in the osteopenia group. The sodium intake of DFQ was positively correlated with the sodium intake of 3 days of dietary records (p=0.0003). There were no significant differences in the sodium intake between the two groups from DFQ. The dishes were ranked by sodium intake: kimchies were 17.68%, noodles and mandu were 16.36%, stews were 13.69%, main dishes such as meat, egg, and beans were 11.47%, and fish and shellfish were 11.07%. The frequency of eating noodles and mandu (p=0.0116), stews (p=0.0008), kimchies (p=0.0482), fish and shellfish (p=0.0362), vegetables (p=0.0064) and seasoning (p=0.0347) were negatively associated with bone mineral density. Bone health was not significantly different with increasing quartiles of sodium intake. As excessive sodium intakes may indirectly affect bone mineral density, these results suggest that to prevent osteoporosis, university students needed to be more educated about diets containing less sodium through nutrition education programs.

Ecological Characteristic between the Re-introduction Population and the Original Population (Jojong Stream, Sudong Stream) of Zacco koreanus in the Bongseonsa Stream, Korea (봉선사천의 참갈겨니(Zacco koreanus) 재도입 개체군과 원개체군(조종천, 수동천) 간 생태학적 특징)

  • Wang, Ju-Hyoun;Choi, Jun-Kil;Lee, Hyuk-Je;Lee, Hwang-Goo
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.6
    • /
    • pp.537-548
    • /
    • 2017
  • The purpose of this study was to investigate the species composition and the aquatic environment of Jojong Stream and Sudong Stream, which were the original habitats of Zacco koreanus population and restored population re-introduced in Bongseonsa Stream. It also compared and analyzed the states of the growth and reproductive ability of Z. koreanus habiting in each of the three streams. The investigation was conducted in June 2016 which was known as the spawning season of Z. koreanus. The results of the physical aquatic environments showed the slight differences in altitude, width and depth of water among three streams, but the bottom structure was found to be quite different in the composition of the boulder, cobble, and pebble among the streams. The result of the physicochemical aquatic environment analysis showed that there were no significant differences in water temperature, pH, DO, BOD, and EC among the three stream. In the fish fauna investigation, 530 individuals of 11 species of 3 families were collected in Bongseonsa Stream, 293 individuals of 12 species of 4 families were collected in Jojong Stream, and 361 individuals of 11 species of 4 families were collected in Sudong Stream. All three streams were dominated by Z. koreanus and Z. platypus. Six Korean endemic species appeared in each of the three streams, showing the high occurrence rate of indigenous species of 50.0% or more. The aggregation index analysis revealed that the mean dominance index ranged from 0.63 (${\pm}0.05$, BS) to 0.72(${\pm}0.01$, JJ), mean diversity index from 1.55 (${\pm}0.06$, JJ) to 1.78 (${\pm}0.11$, BS), mean evenness index from 0.71 (${\pm}0.03$, JJ) to 0.76 (${\pm}0.02$, BS), and mean richness index from 1.61 (${\pm}0.33$, JJ) to 1.73 (${\pm}0.24$, SD). The result indicated that the observed differences between the stream community indices were statistically nonsignificant. The similarity analysis showed that 75.4% similarity was divided into two groups of A and B and that the fish fauna on each analyzed point was similar. The quantitative habitat evaluation index (QHEI) analysis showed that the average value of QHEI was 151.0 (${\pm}46.0$), which means that it was a suboptimal habitat environment. The result of length-weight analysis of Z. koreanus populations showed that the regression coefficient b of the restoration population and the original habitat population were at 3.0 or higher while the condition factor had a positive slope. Moreover, it was found that the slopes of the regression coefficient b and condition factor of the original habitat population were larger than the restored population. The analysis of the length frequency distribution of the Z. koreanus population revealed that all three streams maintained the stable life cycle although it was found that the growth rate of the original habitat population was faster than the restored population in the one-year-old class. The result of the gonadosomatic index (GSI) analysis showed that the GSI median value of the Z. koreanus population in the restored habitat Bongseonsa Stream was higher than the population in the original habitat Jojong Stream and Sudong Stream for both of males and females.

The Evaluation of Hybrid-Volumetric Modulated Arc Therapy for Lung Cancer Radiation Therapy (폐암 방사선 치료 시 Hybrid-Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: In the Lung, the VMAT rotates continuously and examines radiation. That increases the low doses to normal lung. Due to that, the incidence of radiation pneumonia among radiation side effects may increase. The cause of radiation pneumonia is the lower dose area of the lungs. The H-VMAT was applied to patients who applied to reduce radiation in the lower doses of the lungs. We wanted to assess the usefulness of the H-VMAT by comparing the radiation doses to the low dose areas of the lungs and the normal organs. Materials and Methods: A total of 26 patients who applied for a H-VMAT procedure were applied to the patient. The prescription dose applied to total dose 44 Gy from 22 divisions. For each patient, a plan was implemented with Conventional RT, VMAT and H-VMAT. Conventional RT was carried out in four to five fields each, considering the size, location, shape, and location of the PTV. In the case of a VMAT plan, the two Half ARC, three Half ARC method and the two Full ARC were planned. The H-VMAT was planned by adding two Static fields in the VMAT, taking into account the dose of the lung and the tolerance dose of the organs. Results: In the NSCLC, the lung doses $V_5$ and $V_{10}$ of the lungs except for the treatment plan volume were the lowest with $55.40{\pm}13.39%$ and $32.05{\pm}11.37%$ of H-VMAT. And, in the SCLC, the lung doses of V5 and V10 were the lowest at $64.32{\pm}16.15%$ and $35.50{\pm}9.91%$, respectively. The spinal dose of VMAT in NSCLC was $21.15{\pm}4.02Gy$, which was 7.94 Gy lower than other treatment methods. The lowest spinal dose was delivered at $19.72{\pm}1.82Gy$ for SCLC. The mean dose delivered to the esophagus was also $17.44{\pm}2.04Gy$ and $17.84{\pm}9.20Gy$ in SCLC and NSCLC, respectively. Conclusion: When comparing the value of the surrounding normal organ dose, the VMAT showed that less doses were transmitted from the heart, esophagus and spinal cord than the rest of the treatment plan. However, it was similar to VMAT in normal organs except for the spinal cord. VMAT has increased doses of some normal organs but did not exceed the tolerance dose. It showed a low value in $V_5$, $V_{10}$. When comparing Conventional RT, VMAT, and H-VMAT, If the dose to the heart, esophagus and spinal cord is lower than the tolerance dose, it is thought to reduce the incidence of radiation pneumonia by applying H-VMAT that show the benefits of low doses of the lungs.

  • PDF

A Data-based Sales Forecasting Support System for New Businesses (데이터기반의 신규 사업 매출추정방법 연구: 지능형 사업평가 시스템을 중심으로)

  • Jun, Seung-Pyo;Sung, Tae-Eung;Choi, San
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.1
    • /
    • pp.1-22
    • /
    • 2017
  • Analysis of future business or investment opportunities, such as business feasibility analysis and company or technology valuation, necessitate objective estimation on the relevant market and expected sales. While there are various ways to classify the estimation methods of these new sales or market size, they can be broadly divided into top-down and bottom-up approaches by benchmark references. Both methods, however, require a lot of resources and time. Therefore, we propose a data-based intelligent demand forecasting system to support evaluation of new business. This study focuses on analogical forecasting, one of the traditional quantitative forecasting methods, to develop sales forecasting intelligence systems for new businesses. Instead of simply estimating sales for a few years, we hereby propose a method of estimating the sales of new businesses by using the initial sales and the sales growth rate of similar companies. To demonstrate the appropriateness of this method, it is examined whether the sales performance of recently established companies in the same industry category in Korea can be utilized as a reference variable for the analogical forecasting. In this study, we examined whether the phenomenon of "mean reversion" was observed in the sales of start-up companies in order to identify errors in estimating sales of new businesses based on industry sales growth rate and whether the differences in business environment resulting from the different timing of business launch affects growth rate. We also conducted analyses of variance (ANOVA) and latent growth model (LGM) to identify differences in sales growth rates by industry category. Based on the results, we proposed industry-specific range and linear forecasting models. This study analyzed the sales of only 150,000 start-up companies in Korea in the last 10 years, and identified that the average growth rate of start-ups in Korea is higher than the industry average in the first few years, but it shortly shows the phenomenon of mean-reversion. In addition, although the start-up founding juncture affects the sales growth rate, it is not high significantly and the sales growth rate can be different according to the industry classification. Utilizing both this phenomenon and the performance of start-up companies in relevant industries, we have proposed two models of new business sales based on the sales growth rate. The method proposed in this study makes it possible to objectively and quickly estimate the sales of new business by industry, and it is expected to provide reference information to judge whether sales estimated by other methods (top-down/bottom-up approach) pass the bounds from ordinary cases in relevant industry. In particular, the results of this study can be practically used as useful reference information for business feasibility analysis or technical valuation for entering new business. When using the existing top-down method, it can be used to set the range of market size or market share. As well, when using the bottom-up method, the estimation period may be set in accordance of the mean reverting period information for the growth rate. The two models proposed in this study will enable rapid and objective sales estimation of new businesses, and are expected to improve the efficiency of business feasibility analysis and technology valuation process by developing intelligent information system. In academic perspectives, it is a very important discovery that the phenomenon of 'mean reversion' is found among start-up companies out of general small-and-medium enterprises (SMEs) as well as stable companies such as listed companies. In particular, there exists the significance of this study in that over the large-scale data the mean reverting phenomenon of the start-up firms' sales growth rate is different from that of the listed companies, and that there is a difference in each industry. If a linear model, which is useful for estimating the sales of a specific company, is highly likely to be utilized in practical aspects, it can be explained that the range model, which can be used for the estimation method of the sales of the unspecified firms, is highly likely to be used in political aspects. It implies that when analyzing the business activities and performance of a specific industry group or enterprise group there is political usability in that the range model enables to provide references and compare them by data based start-up sales forecasting system.

A Survey of Korean Consumers' Awareness on Animal Welfare of Laying Hens (산란계 동물복지에 대한 국내 소비자의 인지도 조사)

  • Hong, Eui-Chul;Kang, Hwan-Ku;Park, Ki-Tae;Jeon, Jin-Joo;Kim, Hyun-Soo;Kim, Chan-Ho;Kim, Sang-Ho
    • Korean Journal of Poultry Science
    • /
    • v.45 no.3
    • /
    • pp.219-228
    • /
    • 2018
  • This study was conducted twice to investigate egg purchase behavior and perception on animal welfare of Korean consumers. This study included women, who were the main decision makers and caretakers in the household, and men with one-person household. This survey was conducted with by the Computer Assisted Web Interview and Gang Survey methods. On the key considerations factor, the highest response rate was considered to be 'price', and the response rate of considering 'packing date' increased in the second survey. At a reasonable price based on 10 eggs, the response rate was the highest at 53.8% and 42.9% in both the first and second surveys and the appropriate price averages were 2,482 won and 2,132 won, respectively. The highest rate of purchase of egg consumers from 'Large Mart' followed by 'Medium sized supermarket' and 'Chain supermarket'. As for the awareness about animal welfare, the recognition ratio (73.5%) was higher in the result of the second survey than the first. The cognitive period of animal welfare was 59.0% before the insecticide egg crisis and 41.0% thereafter. Regarding whether or not they have ever seen an animal welfare certification mark and an animal welfare animal farm certification mark, 59.6% of respondents said that they saw it for the first time and 37.6% answered that they knew the animal welfare certification mark. On the animal welfare system, the 'free-range' response rate was the highest at 85.8%. The 'free-range' fit response decreased by 34.2%p, while the 'barn' and 'European type' fit response increased by 13.2%p and 24.1%p, respectively. The number of 'I have never seen' and 'I have ever eaten' responses to the recognition and eating experience of animal welfare certified eggs decreased while the number of those who answered 'Have ever seen' and 'Have eaten' increased. The answer of purchasing animal welfare certified eggs at department stores, organic farming cooperatives, and internet shopping malls was higher than that of buying conventional eggs. Of the total respondents, 92.0% were willing to purchase an animal welfare egg before the price was offered, but after offering the prices of animal welfare eggs, the intention to purchase was 62.7%, which was about 30%p lower than before. The reason for purchasing an animal welfare certified egg was the highest score of 71.0% for 'I think it is likely to be high in food safety', and 38.1% for 'I think the price is high' for lack of intention to purchase. In the sensory evaluation of animal welfare eggs, egg color and skin texture of conventional eggs were significantly higher than those of certified welfare eggs (P<0.05), and boiled eggs showed that egg whites of animal welfare certified eggs were more (P<0.05). As a result, the results of this study will contribute to the activation of the animal welfare certification system for laying hens by providing basic data on consumer awareness to animal welfare certified farmers.

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF

The Relation Between Work-Related Musculoskeletal Symptoms and Rapid Upper Limb Assessment(RULA) among Vehicle Assembly Workers (자동차 조립 작업자들에서 상지 근골격계의 인간공학적 작업평가(Rapid Upper Limb Assessment) 결과와 자각증상과의 연관성)

  • Kim, Jae-Young;Kim, Hae-Joon;Choi, Jae-Wook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.1
    • /
    • pp.48-59
    • /
    • 1999
  • Objectives. This study was conducted to evaluate the association between upper extremity musculoskeletal symptoms and Rapid Upper Limb Assessment(RULA) in vehicle assembly line workers. The goal of this study is to show the feasibility of RULA as a checklist for work related musculoskeletal symptoms (WMSDs) in Korean workers. Methods. The total number of 199 people from the department of assembly and 115 people from the department of Quality Control(QC) in automotive plant were subjects for this cross sectional study. A standard symptom questionnaire survey has been used for the individual characteristics, work history, musculosketal symptoms and non-occupational covariates. The data were obtained by applying one-on-one interview for the all subjects. RULA has been applied for ergonomic work posture analysis and the primary ergonomic risk sure was computed by RULA method. Association between upper extremity musculoskeletal symptoms and RULA were assessed by multiple logistic regression analysis. Results. A total of 314 workers was examined. The prevalence of musculoskeletal symptoms by NIOSH case definition was 62.4%. The distribution of musculoskeletal symptoms by the part of the body turned out to be following; back:41.4%, neck: 32.8%, shoulder: 26.4%, arm: 10.5% and hand:29.3%. The relationship of the individual RULA scores were statistically significant for the prevalence of musculoskeletal symptoms. As the result of the multiple logistic regressioin analysis, grand final score (OR=2.250 95% CI: 1.402-3.612) was associated with musculoskeletal symptoms in any part of the body.; upper arm score(OR=1.786 95% CI: 1.036-3.079) and posture score A(OR=1.634 95% CI: 1.016-2.626) in neck; muscel use score(OR=3.076 95% CI:1.782-5.310) and posture score A(OR=1.798 95% CI: 1.072-3.017) in shoulder; upper arm score(OR=1.715 95% CI: 1.083-2.715) and muscel use score(OR=2.057 95% CI:1.303-3.248) in neck & shoulder; muscle use score(OR=10.662 95% CI: 3.180-35.742) in arm; writst/wist score(OR=2.068 95% CI: 1.130-3.786) and muscle use score(OR=2.215 95% CI: 1.284-3.819) in hand & wrist.; muscle use score of trunk (OR=2.601 95% CI: 1.147-5.901) in back. Conclusions. Musculoskeletal symptoms of the extremities were strongly associated with individual RULA body score. These results show that RULA can be used as a useful assessment tool for the evaluation of musculoskeletal loading which is known to contribute to work-related musculoskeletal disorders. RULA also can be used as a screening tool or incorporated into a wider ergonomic assessment of epidemiological, physical, mental, environmental and organizational factors. As shown in this study, complement of the analysis system for the other risk factors and characterizing between the upper limb and back part will be needed for future work.

  • PDF

Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays (크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가)

  • Park Sang-Jung;Cho Min;Yoon Je-Yong;Jun Yong-Sung;Rim Yeon-Taek;Jin Ing-Nyol;Chung Hyen-Mi
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.534-539
    • /
    • 2006
  • In the ozone disinfection unit process of a piston type batch reactor with continuous ozone analysis using a flow injection analysis (FIA) system, the CT values for 1 log inactivation of Cryptosporidium parvum by viability assays of DAPI/PI and excystation were $1.8{\sim}2.2\;mg/L{\cdot}min$ at $25^{\circ}C$ and $9.1mg/L{\cdot}min$ at $5^{\circ}C$, respectively. At the low temperature, ozone requirement rises $4{\sim}5$ times higher in order to achieve the same level of disinfection at room temperature. In a 40 L scale pilot plant with continuous flow and constant 5 minutes retention time, disinfection effects were evaluated using excystation, DAPI/PI, and cell infection method at the same time. About 0.2 log inactivation of Cryptosporidium by DAPI/PI and excystation assay, and 1.2 log inactivation by cell infectivity assay were estimated, respectively, at the CT value of about $8mg/L{\cdot}min$. The difference between DAPI/PI and excystation assay was not significant in evaluating CT values of Cryptosporidium by ozone in both experiment of the piston and the pilot reactors. However, there was significant difference between viability assay based on the intact cell wall structure and function and infectivity assay based on the developing oocysts to sporozoites and merozoites in the pilot study. The stage of development should be more sensitive to ozone oxidation than cell wall intactness of oocysts. The difference of CT values estimated by viability assay between two studies may partly come from underestimation of the residual ozone concentration due to the manual monitoring in the pilot study, or the difference of the reactor scale (50 mL vs 40 L) and types (batch vs continuous). Adequate If value to disinfect 1 and 2 log scale of Cryptosporidium in UV irradiation process was 25 $mWs/cm^2$ and 50 $mWs/cm^2$, respectively, at $25^{\circ}C$ by DAPI/PI. At $5^{\circ}C$, 40 $mWs/cm^2$ was required for disinfecting 1 log Cryptosporidium, and 80 $mWs/cm^2$ for disinfecting 2 log Cryptosporidium. It was thought that about 60% increase of If value requirement to compensate for the $20^{\circ}C$ decrease in temperature was due to the low voltage low output lamp letting weaker UV rays occur at lower temperatures.